Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Curr Med Imaging ; 2024 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-38874026

RESUMO

PURPOSE: To explore the potential of diffusion kurtosis imaging (DKI) for assessing the degree of liver injury in a paracetamol-induced rat model and to simultaneously investigate the effect of intravenous gadoxetate on DKI parameters. METHODS: Paracetamol was used to induce hepatoxicity in 39 rats. The rats were pathologically classified into 3 groups: normal (n=11), mild necrosis (n=18), and moderate necrosis (n=10). DKI was performed before and, 15 min, 25 min, and 45 min after gadoxetate administration. Repeated-measures ANOVA with Tukey's multiple comparison test was used to investigate the effect of gadoxetate on mean diffusivity (MD) and mean diffusion kurtosis (MK) and to assess the differences in MD and MK among the three groups. A receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic accuracy of the MD values when discriminating between the necrotic groups. RESULTS: Gadoxetate had no significant effect on either the MD or the MK, and the effect size was small. The MD in the moderate necrosis group was significantly lower than that in the other two groups (F = 13.502, p < 0.001; η2 = 0.428 [95% CI: 0.082-0.637]), while the MK did not significantly differ among the three groups (F = 2.702, p = 0.081; η2 = 0.131 [95% CI: 0.001-0.4003]). The AUCs of MD for discriminating the moderate necrosis or normal group from the other groups were 0.921 (95% CI: 0.832-1.000) and 0.831 (95% CI: 0.701-0.961), respectively. CONCLUSION: It would be better to measure the MD and MK before gadoxetate injection. MD showed potential for assessing the degree of liver necrosis in a paracetamol-induced liver injury rat model.

2.
Quant Imaging Med Surg ; 14(5): 3717-3730, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38720853

RESUMO

Background: Accurate preoperative diagnosis of endometrial cancer (EC) with deep myometrial invasion (DMI) is critical to deciding whether to perform lymphadenectomy. However, the presence of adenomyosis makes distinguishing DMI from superficial myometrial invasion (SMI) on magnetic resonance imaging (MRI) challenging. We aimed to evaluate the accuracy of multiparametric MRI (mpMRI) in diagnosing DMI in EC coexisting with adenomyosis (EC-A) compared with EC without coexisting adenomyosis and to evaluate the effect of different adenomyosis subtypes on myometrial invasion (MI) depth in EC. Methods: Patients with histologically confirmed International Federation of Gynecology and Obstetrics (FIGO) stage I EC who underwent preoperative MRI were consecutively included in this 2-center retrospective study. Institution 1 was searched from January 2017 to November 2022 and institution 2 was searched from June 2017 to March 2021. Patients were divided into 2 groups: group A, patients with EC-A; group B, EC patients without coexisting adenomyosis, matched 1:2 according to age ±5 years and tumor grade. A senior radiologist assessed the MRI adenomyosis classification in group A. Then, 2 radiologists (R1/R2) independently interpreted T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), T1-weighted contrast-enhanced (T1CE), and a combination of all images (mpMRI) respectively, and then assessed MI depth. Accuracy, sensitivity, specificity, and the areas under the receiver operating curve (AUC) were calculated. The chi-square test was used to compare the accuracy of diagnosing DMI. Interobserver agreement was evaluated using the Kappa test. Results: A total of 70 cases in group A and 140 cases in group B were included. The accuracy, sensitivity, and specificity of consensus were 94.3% [95% confidence interval (CI): 88.9-99.7%] vs. 92.1% (95% CI: 87.7-96.6%), 60.0% (95% CI: 17-92.7%) vs. 86.7% (95% CI: 68.4-95.6%), and 96.9% (95% CI: 88.4-95.5%) vs. 93.6% (95% CI: 86.8-97.2%) (group A vs. group B, respectively). There was no significant difference in the diagnostic accuracy of DMI on each sequence between the groups (Reviewer 1/Reviewer 2): PT2WI=0.14/0.17, PDWI=0.50/0.33, PT1CE=0.90/0.18, PmpMRI=0.50/0.37. The AUC for T2WI, DWI, T1CE, and mpMRI (Reviewer 1/Reviewer 2), respectively, were 0.54 (95% CI: 0.42-0.66)/0.78 (95% CI: 0.67-0.87), 0.63 (95% CI: 0.50-0.74)/0.77 (95% CI: 0.65-0.86), 0.69 (95% CI: 0.57-0.80)/0.79 (95% CI: 0.68-0.88), and 0.91 (95% CI: 0.82-0.97)/0.89 (95% CI: 0.79-0.95) (group A) and 0.83 (95% CI: 0.76-0.89)/0.85 (95% CI: 0.78-0.90), 0.83 (95% CI: 0.76-0.89)/0.86 (95% CI: 0.79-0.91), 0.88 (95% CI: 0.82-0.93)/0.86 (95% CI: 0.80-0.92), and 0.91 (95% CI: 0.85-0.95)/0.87 (95% CI: 0.80-0.92) (group B). Interobserver agreement was highest with mpMRI [κ=0.387/0.695 (case/control)]. The consensus results of MRI categorization of adenomyosis revealed no significant difference in the accuracy of diagnosing DMI by adenomyosis subtype (Pspatial relationship>0.99, Paffected area=0.52, Paffected pattern=0.58, Paffected size>0.99). Conclusions: The presence of adenomyosis or adenomyosis subtype had no significant effect on the interpretation of the depth of MI. T1CE can increase the contrast between adenomyosis and cancer foci; therefore, the information provided by T1CE should be valued.

3.
Sci Rep ; 14(1): 7022, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528042

RESUMO

In the evolving landscape of smart libraries, this research pioneers an IoT-based low-cost architecture utilizing Software-Defined Networking (SDN). The increasing demand for more efficient and economical solutions in library management, particularly in the realm of RFID-based processes such as authentication, property circulation, and book loans, underscores the significance of this study. Leveraging the collaborative potential of IoT and SDN technologies, our proposed system introduces a fresh perspective to tackle these challenges and advance intelligent library management. In response to the evolving landscape of smart libraries, our research presents an Internet of Things (IoT)-based low-cost architecture utilizing SDN. The exploration of this architectural paradigm arises from a recognized gap in the existing literature, pointing towards the necessity for more efficient and cost-effective solutions in managing library processes. Our proposed algorithm integrates IoT and SDN technologies to intelligently oversee various library activities, specifically targeting RFID-based processes such as authentication, property circulation management, and book loan management. The system's architecture, encompasses components like the data center, SDN controllers, RFID tags, tag readers, and other network sensors. By leveraging the synergy between RFID and SDN, our innovative approach reduces the need for constant operator supervision in libraries. The scalability and software-oriented nature of the architecture cater to extensive library environments. Our study includes a two-phase investigation, combining practical implementation in a small-scale library with a simulation environment using MATLAB 2021. This research not only fills a crucial gap in current knowledge but also lays the foundation for future advancements in the integration of IoT and SDN technologies for intelligent library management.

4.
Abdom Radiol (NY) ; 49(5): 1411-1418, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38461432

RESUMO

PURPOSE: Partial correlation analysis was performed to account for the interference of steatosis changes and inflammatory factors, to determine the true correlation between fibrosis and IVIM parameters (Dfast, Dslow, and F), and to evaluate the diagnostic efficacy of IVIM for liver fibrosis. METHODS: A total of 106 patients with metabolic dysfunction-associated steatotic liver disease (MASLD) examined by IVIM from November 2016 to November 2023 at our hospital were retrospectively included. Preliminary analysis of each IVIM parameter and correlations with pathological findings were performed using Spearman correlation analysis, and partial correlation analysis was used to exclude the interference of other pathological factors, thus yielding the true correlations between IVIM parameters (Dfast, Dslow, and F) and pathology. The diagnostic efficacy of IVIM parameters for diagnosing MASLD was assessed via receiver operating characteristic (ROC) curve analysis. RESULTS: Spearman correlation analysis of all the IVIM parameters revealed correlations with steatosis, lobular inflammation, and ballooning. Partial correlation analysis indicated that Dfast was correlated with the pathological fibrosis stage (r = - 0.593, P < 0.001), Dslow was correlated with the pathological steatosis score (r = - 0.313, P < 0.05), and F was correlated with the pathological fibrosis stage and steatosis score (r = - 0.456 and 0.255, P < 0.001 and P < 0.05). In the diagnosis of hepatic fibrosis, significant hepatic fibrosis, advanced liver fibrosis and cirrhosis, Dfast achieved areas under the ROC curve of 0.763, 0.801, 0.853, and 0.897, respectively. The threshold values for diagnosing different fibrosis stages using Dfast (10-3 mm2/s) were 57.613, 54.587, 52.714, and 51.978, respectively. CONCLUSION: According to our partial correlation analysis, there was a moderate correlation between Dfast and F according to fibrosis stage, and Dfast was not influenced by inflammation or steatosis when diagnosing fibrosis in MASLD patients. A relatively close Dfast threshold is insufficient for accurately and noninvasively assessing various stages of MASLD fibrosis. In clinical practice, this approach can be considered an alternative method for the preliminary assessment of fibrosis in MASLD patients.


Assuntos
Cirrose Hepática , Humanos , Feminino , Masculino , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Adulto , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Fígado/patologia
5.
Abdom Radiol (NY) ; 49(3): 942-957, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38102443

RESUMO

PURPOSE: To explore the feasibility of a 5G-based telerobotic ultrasound (US) system for providing qualified abdominal US services on a rural island. METHODS: This prospective study involved two medical centers (the tele-radiologist site's hospital and the patient site's hospital) separated by 72 km. Patients underwent 5G-based telerobotic US by tele-radiologists and conventional US by on-site radiologists from September 2020 to March 2021. The clinical feasibility and diagnostic performance of the 5G-based telerobotic abdominal US examination were assessed based on safety, duration, image quality, diagnostic findings, and questionnaires. RESULTS: A total of 401 patients (217 women and 184 men; mean age, 54.96 ± 15.43 years) were enrolled. A total of 90.1% of patients indicated no discomfort with the telerobotic US examination. For the examination duration, telerobotic US took longer than conventional US (12.54 ± 3.20 min vs. 7.23 ± 2.10 min, p = 0.001). For image quality scores, the results of the two methods were similar (4.54 ± 0.63 vs. 4.57 ± 0.61, p = 0.112). No significant differences were found between the two methods in measurements for the aorta, portal vein, gallbladder, kidney (longitudinal diameter), prostate, and uterus; however, telerobotic US underestimated the transverse diameter of the kidney (p < 0.05). A total of 504 positive results, including 31 different diseases, were detected. Among them, 455 cases were identified by the two methods; 17 cases were identified by telerobotic US only; and 32 cases were identified by conventional US only. There was good consistency in the diagnosis of 29 types of disease between the two methods (κ = 0.773-1.000). Furthermore, more than 90% of patients accepted the telerobotic US examination and agreed to pay additional fees in future. CONCLUSION: The 5G-based telerobotic US system can expand access to abdominal US services for patients in rural areas, thereby reducing health care disparities.


Assuntos
Robótica , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Robótica/métodos , Ultrassonografia , Abdome/diagnóstico por imagem , Rim
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA