Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Acta Biomater ; 180: 372-382, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38614415

RESUMO

Catheter-induced thrombosis is a major contributor to infectious and mechanical complications of biomaterials that lead to device failure. Herein, a dualfunction submicron textured nitric oxide (NO)-releasing catheter was developed. The hemocompatibility and antithrombotic activity of vascular catheters were evaluated in both 20 h in vitro blood loop and 7 d in vivo rabbit model. Surface characterization assessments via atomic force microscopy show the durability of the submicron pattern after incorporation of NO donor S-nitroso-N-acetylpenicillamine (SNAP). The SNAP-doped catheters exhibited prolonged and controlled NO release mimicking the levels released by endothelium. Fabricated catheters showed cytocompatibility when evaluated against BJ human fibroblast cell lines. After 20h in vitro evaluation of catheters in a blood loop, textured-NO catheters exhibited a 13-times reduction in surface thrombus formation compared to the control catheters, which had 83% of the total area covered by clots. After the 7 d in vivo rabbit model, analysis on the catheter surface was examined via scanning electron microscopy, where significant reduction of platelet adhesion, fibrin mesh, and thrombi can be observed on the NO-releasing textured surfaces. Moreover, compared to relative controls, a 63% reduction in the degree of thrombus formation within the jugular vein was observed. Decreased levels of fibrotic tissue decomposition on the jugular vein and reduced platelet adhesion and thrombus formation on the texture of the NO-releasing catheter surface are indications of mitigated foreign body response. This study demonstrated a biocompatible and robust dual-functioning textured NO PU catheter in limiting fouling-induced complications for longer-term blood-contacting device applications. STATEMENT OF SIGNIFICANCE: Catheter-induced thrombosis is a major contributor to infectious and mechanical complications of biomaterials that lead to device failure. This study demonstrated a robust, biocompatible, dual-functioning textured nitric oxide (NO) polyurethane catheter in limiting fouling-induced complications for longer-term blood-contacting device applications. The fabricated catheters exhibited prolonged and controlled NO release that mimics endothelium levels. After the 7 d in vivo model, a significant reduction in platelet adhesion, fibrin mesh, and thrombi was observed on the NO-releasing textured catheters, along with decreased levels of fibrotic tissue decomposition on the jugular vein. Results illustrate that NO-textured catheter surface mitigates foreign body response.


Assuntos
Catéteres , Óxido Nítrico , S-Nitroso-N-Acetilpenicilamina , Animais , Coelhos , Óxido Nítrico/metabolismo , Humanos , S-Nitroso-N-Acetilpenicilamina/farmacologia , S-Nitroso-N-Acetilpenicilamina/química , Trombose/patologia , Teste de Materiais , Linhagem Celular , Adesividade Plaquetária/efeitos dos fármacos , Modelos Animais de Doenças
2.
ACS Appl Mater Interfaces ; 16(7): 8474-8483, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38330222

RESUMO

Bacterial intracellular nucleotide second messenger signaling is involved in biofilm formation and regulates biofilm development. Interference with the bacterial nucleotide second messenger signaling provides a novel approach to control biofilm formation and limit microbial infection in medical devices. In this study, we tethered small-molecule derivatives of 4-arylazo-3,5-diamino-1H-pyrazole on polyurethane biomaterial surfaces and measured the biofilm resistance and initial biocompatibility of modified biomaterials in in vitro and in vivo settings. Results showed that small-molecule-modified surfaces significantly reduced the Staphylococcal epidermidis biofilm formation compared to unmodified surfaces and decreased the nucleotide levels of c-di-AMP in biofilm cells, suggesting that the tethered small molecules interfere with intracellular nucleotide signaling and inhibit biofilm formation. The hemocompatibility assay showed that the modified polyurethane films did not induce platelet activation or red blood cell hemolysis but significantly reduced plasma coagulation and platelet adhesion. The cytocompatibility assay with fibroblast cells showed that small-molecule-modified surfaces were noncytotoxic and cells appeared to be proliferating and growing on modified surfaces. In a 7-day subcutaneous infection rat model, the polymer samples were implanted in Wistar rats and inoculated with bacteria or PBS. Results show that modified polyurethane significantly reduced bacteria by ∼2.5 log units over unmodified films, and the modified polymers did not lead to additional irritation/toxicity to the animal tissues. Taken together, the results demonstrated that small molecules tethered on polymer surfaces remain active, and the modified polymers are biocompatible and resistant to microbial infection in vitro and in vivo.


Assuntos
Infecções Bacterianas , Materiais Biocompatíveis , Ratos , Animais , Materiais Biocompatíveis/farmacologia , Aderência Bacteriana , Poliuretanos/farmacologia , Ratos Wistar , Biofilmes , Infecções Bacterianas/microbiologia , Polímeros , Bactérias , Nucleotídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA