Med Phys ; 51(5): 3619-3634, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38517359

RESUMO

BACKGROUND: This study addresses the technical gap between clinical radiation therapy (RT) and preclinical small-animal RT, hindering the comprehensive validation of innovative clinical RT approaches in small-animal models of cancer and the translation of preclinical RT studies into clinical practices. PURPOSE: The main aim was to explore the feasibility of biologically guided RT implemented within a small-animal radiation therapy (SART) platform, with integrated quad-modal on-board positron emission tomography (PET), single-photon emission computed tomography, photon-counting spectral CT, and cone-beam CT (CBCT) imaging, in a Monte Carlo model as a proof-of-concept. METHODS: We developed a SART workflow employing quad-modal imaging guidance, integrating multimodal image-guided RT and emission-guided RT (EGRT). The EGRT algorithm was outlined using positron signals from a PET radiotracer, enabling near real-time adjustments to radiation treatment beams for precise targeting in the presence of a 2-mm setup error. Molecular image-guided RT, incorporating a dose escalation/de-escalation scheme, was demonstrated using a simulated phantom with a dose painting plan. The plan involved delivering a low dose to the CBCT-delineated planning target volume (PTV) and a high dose boosted to the highly active biological target volume (hBTV) identified by the 18F-PET image. Additionally, the Bayesian eigentissue decomposition method illustrated the quantitative decomposition of radiotherapy-related parameters, specifically iodine uptake fraction and virtual noncontrast (VNC) electron density, using a simulated phantom with Kidney1 and Liver2 inserts mixed with an iodine contrast agent at electron fractions of 0.01-0.02. RESULTS: EGRT simulations generated over 4,000 beamlet responses in dose slice deliveries and illustrated superior dose coverage and distribution with significantly lower doses delivered to normal tissues, even with a 2-mm setup error introduced, demonstrating the robustness of the novel EGRT scheme compared to conventional image-guided RT. In the dose-painting plan, doubling the dose to the hBTV while maintaining a low dose for the PTV resulted in an organ-at-risk (OAR) dose comparable to the low-dose treatment for the PTV alone. Furthermore, the decomposition of radiotherapy-related parameters in Kidney1 and Liver2 inserts, including iodine uptake fractions and VNC electron densities, exhibited average relative errors of less than 1.0% and 2.5%, respectively. CONCLUSIONS: The results demonstrated the successful implementation of biologically guided RT within the proposed quad-model image-guided SART platform, with potential applications in preclinical RT and adaptive RT studies.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Método de Monte Carlo , Radioterapia Guiada por Imagem , Radioterapia Guiada por Imagem/métodos , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Imagem Multimodal , Imagens de Fantasmas
2.
Med Phys ; 51(4): 2941-2954, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38421665

RESUMO

BACKGROUND: In spite of the tremendous potential of game-changing biological image- and/or biologically guided radiation therapy (RT) and adaptive radiation therapy for cancer treatment, existing limited strategies for integrating molecular imaging and/or biological information with RT have impeded the translation of preclinical research findings to clinical applications. Additionally, there is an urgent need for a highly integrated small-animal radiation therapy (SART) platform that can seamlessly combine therapeutic and diagnostic capabilities to comprehensively enhance RT for cancer treatment. PURPOSE: We investigated a highly integrated quad-modal on-board imaging configuration combining positron emission tomography (PET), single-photon emission computed tomography (SPECT), photon-counting spectral CT, and cone-beam computed tomography (CBCT) in a SART platform using a Monte Carlo model as a proof-of-concept. METHODS: The quad-modal on-board imaging configuration of the SART platform was designed and evaluated by using the GATE Monte Carlo code. A partial-ring on-board PET imaging subsystem, utilizing advanced semiconductor thallium bromide detector technology, was designed to achieve high sensitivity and spatial resolution. On-board SPECT, photon-counting spectral-CT, and CBCT imaging were performed using a single cadmium zinc telluride flat detector panel. The absolute peak sensitivity and scatter fraction of the PET subsystem were estimated by using simulated phantoms described in the NEMA NU-4 standard. The spatial resolution of the PET image of the platform was evaluated by imaging a simulated micro-Derenzo hot-rod phantom. To evaluate the quantitative imaging capability of the system's spectral CT, the Bayesian eigentissue decomposition (ETD) method was utilized to quantitatively decompose the virtual noncontrast (VNC) electron densities and iodine contrast agent fractions in the Kidney1 inserts mixed with the iodine contrast agent within the simulated phantoms. The performance of the proposed quad-model imaging in the platform was validated by imaging a simulated phantom with multiple imaging probes, including an iodine contrast agent and radioisotopes of 18F and 99mTc. RESULTS: The PET subsystem demonstrated an absolute peak sensitivity of 18.5% at the scanner center, with an energy window of 175-560 KeV, and a scatter fraction of only 3.5% for the mouse phantom, with a default energy window of 480-540 KeV. The spatial resolution of PET on-board imaging exceeded 1.2 mm. All imaging probes were identified clearly within the phantom. The PET and SPECT images agreed well with the actual spatial distributions of the tracers within the phantom. Average relative errors on electron density and iodine contrast agent fraction in the Kidney1 inserts were less than 3%. High-quality PET images, SPECT images, spectral-CT images (including iodine contrast agent fraction images and VNC electron density images), and CBCT images of the simulated phantom demonstrated the comprehensive multimodal imaging capability of the system. CONCLUSIONS: The results demonstrated the feasibility of the proposed quad-modal imaging configuration in a SART platform. The design incorporates anatomical, molecular, and functional information about tumors, thereby facilitating successful translation of preclinical studies into clinical practices.


Assuntos
Iodo , Tomografia Computadorizada de Feixe Cônico Espiral , Camundongos , Animais , Meios de Contraste , Teorema de Bayes , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagens de Fantasmas , Método de Monte Carlo