Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Microsc Microanal ; 30(1): 118-132, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38156737

RESUMO

Automated quantification of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) using whole slide imaging (WSI) is expected to eliminate subjectivity in visual assessment. However, the color intensity in WSI varies depending on the staining process and scanner device. Such variations affect the image analysis results. This paper presents methods to diminish the influence of color variation produced in the staining process using a calibrator slide consisting of peptide-coated microbeads. The calibrator slide is stained along with tissue sample slides, and the 3,3'-diaminobenzidine (DAB) color intensities of the microbeads are used for calibrating the color variation of the sample slides. An off-the-shelf image analysis tool is employed for the automated assessment, in which cells are classified by the thresholds for the membrane staining. We have adopted two methods for calibrating the color variation based on the DAB color intensities obtained from the calibrator slide: (1) thresholds for classifying the DAB membranous intensity are adjusted, and (2) the color intensity of WSI is corrected. In the experiment, the calibrator slides and tissue of breast cancer slides were stained together on different days and used to test our protocol. With the proposed protocol, the discordance in the HER2 evaluation was reduced to one slide out of 120 slides.


Assuntos
Neoplasias da Mama , Corantes , Humanos , Feminino , Imuno-Histoquímica , Calibragem , Processamento de Imagem Assistida por Computador/métodos
2.
Appl Microsc ; 53(1): 8, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37704877

RESUMO

In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) - one of the standard biomarkers for breast cancer- visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist's assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.

3.
Mod Pathol ; 33(12): 2449-2457, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32616872

RESUMO

In the modern era, detailed pathologic characteristics of a thyroid tumor are crucial to achieve accurate diagnosis and guide treatment. The presence of capsular invasion (CI) is diagnostic for carcinoma, whereas vascular invasion (VI) and nodal metastasis (NM) are included in risk stratification. However, the very definition of CI and VI is surrounded by controversies and an accurate assessment of NM is lacking. Whole Block Imaging (WBI) by microCT is a new imaging modality to create 3D reconstruction of whole tissue block with microscopic level resolution without the need for tissue sectioning. In this study, we aimed to define CI, VI, and NM volume using WBI by microCT. Twenty-eight paraffin blocks (PBs) from 26 thyroid tumors were scanned. Ten PBs contained CI, whereas 7 had VI. 3D microCT images were compared with whole slide images (WSI) of corresponding H&E slides. In 2 cases with VI and/or CI, WSI of serial H&E slides were obtained and underwent 3D-reconstruction to be compared with the WBI. Satellite tumor nodules beyond tumor capsule were shown to be CI by demonstrating the point of penetration using microCT and 3D reconstruction. Additional foci of CI were detected using microCT. VI was seen using microCT. Fibrin associated with tumor thrombus was not always present on serially sectioned H&E slides. WBI by microCT scanner was able to assess the volume of NM. In conclusion, WBI is able to detect CI, VI, and assess the volume of NM in thyroid carcinoma without tissue sectioning. It is the ultimate method for the complete sampling of the tumor capsule. It has the potential to increase the detection rate of CI, better define criteria for CI and VI, and provide an accurate assessment of the volume of nodal disease. This technology may impact the future practice of surgical pathology.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Carcinoma/diagnóstico por imagem , Imageamento Tridimensional , Linfonodos/diagnóstico por imagem , Inclusão em Parafina , Interpretação de Imagem Radiográfica Assistida por Computador , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Microtomografia por Raio-X , Vasos Sanguíneos/patologia , Carcinoma/secundário , Humanos , Linfonodos/patologia , Metástase Linfática , Invasividade Neoplásica , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Neoplasias da Glândula Tireoide/patologia
4.
Arch Pathol Lab Med ; 143(12): 1545-1555, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31173528

RESUMO

CONTEXT.­: Digital pathology (DP) implementations vary in scale, based on aims of intended operation. Few laboratories have completed a full-scale DP implementation, which may be due to high overhead costs that disrupt the traditional pathology workflow. Neither standardized criteria nor benchmark data have yet been published showing practical return on investment after implementing a DP platform. OBJECTIVE.­: To provide benchmark data and practical metrics to support operational efficiency and cost savings in a large academic center. DESIGN.­: Metrics reviewed include archived pathology asset retrieval; ancillary test request for recurrent/metastatic disease; cost analysis and turnaround time (TAT); and DP experience survey. RESULTS.­: Glass slide requests from the department slide archive and an off-site surgery center showed a 93% and 97% decrease, respectively. Ancillary immunohistochemical orders, compared in 2014 (52%)-before whole slide images (WSIs) were available in the laboratory information system-and 2017 (21%) showed $114 000/y in anticipated savings. Comprehensive comparative cost analysis showed a 5-year $1.3 million savings. Surgical resection cases with prior WSIs showed a 1-day decrease in TAT. A DP experience survey showed 80% of respondents agreed WSIs improved their clinical sign-out experience. CONCLUSIONS.­: Implementing a DP operation showed a noteworthy increase in efficiency and operational utility. Digital pathology deployments and operations may be gauged by the following metrics: number of glass slide requests as WSIs become available, decrease in confirmatory testing for patients with metastatic/recurrent disease, long-term decrease in off-site pathology asset costs, and faster TAT. Other departments may use our benchmark data and metrics to enhance patient care and demonstrate return on investment to justify adoption of DP.


Assuntos
Diagnóstico por Imagem/economia , Diagnóstico por Imagem/métodos , Patologia Clínica/economia , Patologia Clínica/métodos , Eficiência , Humanos , Fluxo de Trabalho
5.
Anal Cell Pathol (Amst) ; 35(4): 251-65, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22425661

RESUMO

INTRODUCTION: The advent of digital slides offers new opportunities within the practice of pathology such as the use of image analysis techniques to facilitate computer aided diagnosis (CAD) solutions. Use of CAD holds promise to enable new levels of decision support and allow for additional layers of quality assurance and consistency in rendered diagnoses. However, the development and testing of prostate cancer CAD solutions requires a ground truth map of the cancer to enable the generation of receiver operator characteristic (ROC) curves. This requires a pathologist to annotate, or paint, each of the malignant glands in prostate cancer with an image editor software - a time consuming and exhaustive process. Recently, two CAD algorithms have been described: probabilistic pairwise Markov models (PPMM) and spatially-invariant vector quantization (SIVQ). Briefly, SIVQ operates as a highly sensitive and specific pattern matching algorithm, making it optimal for the identification of any epithelial morphology, whereas PPMM operates as a highly sensitive detector of malignant perturbations in glandular lumenal architecture. METHODS: By recapitulating algorithmically how a pathologist reviews prostate tissue sections, we created an algorithmic cascade of PPMM and SIVQ algorithms as previously described by Doyle el al. [1] where PPMM identifies the glands with abnormal lumenal architecture, and this area is then screened by SIVQ to identify the epithelium. RESULTS: The performance of this algorithm cascade was assessed qualitatively (with the use of heatmaps) and quantitatively (with the use of ROC curves) and demonstrates greater performance in the identification of malignant prostatic epithelium. CONCLUSION: This ability to semi-autonomously paint nearly all the malignant epithelium of prostate cancer has immediate applications to future prostate cancer CAD development as a validated ground truth generator. In addition, such an approach has potential applications as a pre-screening/quality assurance tool.


Assuntos
Adenocarcinoma/diagnóstico , Algoritmos , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Diagnóstico por Computador/métodos , Humanos , Masculino , Cadeias de Markov , Modelos Estatísticos , Reconhecimento Automatizado de Padrão/métodos , Curva ROC
6.
J Med Syst ; 26(4): 277-83, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12118811

RESUMO

Internet Protocol (IP) based networks are increasingly being used as alternatives to the traditional circuit-switched networks for carrying voice traffic. IP telephony is taking a firm hold in the world telecommunication market for a wide range of applications including telemedicine. The merits of IP telephony for telemedicine lie in cost-savings and new applications and functionalities it may render. In this paper, we try to discuss and analyze the implications of IP telephony on the evolution and deployment of telemedicine and e-health.


Assuntos
Redes de Comunicação de Computadores/tendências , Internet/tendências , Consulta Remota/tendências , Telecomunicações/tendências , Redes de Comunicação de Computadores/instrumentação , Humanos , Internet/instrumentação , Japão , Relações Médico-Paciente , Consulta Remota/economia , Consulta Remota/instrumentação , Telecomunicações/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA