Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Perinatol ; 43(10): 1295-1300, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37582931

RESUMO

OBJECTIVE: To assess the reliability of pulmonary artery (PA) parameters as a prognostic marker in neonates with isolated left-sided congenital diaphragmatic hernia (IL-CDH). STUDY DESIGN: A retrospective cohort study conducted by the Japanese CDH Study Group (JCDHSG). RESULTS: 323 IL-CDH patients registered with the JCDHSG were included. 272 patients survived to 90 days of age. Right PA (RPA) and left PA (LPA) diameters and pulmonary artery index (PAIndex) at birth were significantly larger in survivors. The cutoff values of RPA and LPA diameters and PAIndex for survival up to 90 days were 3.2 mm, 2.8 mm and 83.7, respectively, and logistic regression analysis showed that these were significantly related to survival. Multiple logistic regression analysis showed that both the PA parameters and liver herniation were significantly related to survival. CONCLUSIONS: The three PA parameters at birth can predict clinical outcomes and are considered as independent risk factors of liver herniation.


Assuntos
Hérnias Diafragmáticas Congênitas , Recém-Nascido , Humanos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Artéria Pulmonar , Prognóstico , Peso ao Nascer , Estudos Retrospectivos , Japão/epidemiologia , Reprodutibilidade dos Testes
2.
Pediatr Int ; 64(1): e14856, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34048141

RESUMO

BACKGROUND: Congenital porto-systemic shunt (CPSS) is a rare disease and can cause fatal complications. Accurate angiographic assessment is mandatory for proper treatment. Although technically difficult, we developed assessment techniques and assessed their accuracy. One technique came from evaluating patients with extrahepatic portal vein obstruction (EHPVO). METHODS: We conducted a single center retrospective study to evaluate the efficacy of angiographic diagnostic procedure for the assessment of CPSS and EHPVO, and its impact on patients' subsequent interventions and clinical course. Eight patients with CPSS and two patients with EHPVO who underwent diagnostic angiography were included. Assessment of the intrahepatic portal vein was performed in all patients. The route of the shunt, and portal vein pressure under shunt occlusion, were also evaluated for patients with CPSS. Evaluation was first attempted with a balloon angiographic catheter (standard method). Three additional techniques were performed as needed: (i) direct wedge-catheter injection without balloon inflation, (ii) use of occlusion balloon in two patients, and (iii) hybrid angiography with sheath placement directly into the superior mesenteric vein. RESULTS: The standard method was sufficient in four patients. On the other hand, all three techniques were required in two patients each. One lost contact during follow up, but all other patients underwent optimal intervention. There were no complications related to the angiographic procedure. CONCLUSIONS: Use of direct wedge-catheter injection without balloon inflation, occlusion balloon, and hybrid catheterization improved the diagnostic yield in patients with CPSS or EHPVO.


Assuntos
Hipertensão Portal , Doenças Vasculares , Angiografia , Criança , Humanos , Hipertensão Portal/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA