Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Singapore Med J ; 62(4): 199-203, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32179923

RESUMO

INTRODUCTION: Pulmonary arterial hypertension (PAH) is associated with high medical and pharmaceutical costs. Phosphodiesterase type 5 (PDE5) inhibitors have been found to be beneficial but costly. They are not subsidised in Singapore except via the Medication Assistance Fund (MAF) Plus scheme. In this study, we described the help-seeking behaviour of patients and funding strategies for Singaporean patients on PDE5 inhibitors in our registry. METHODS: We consecutively recruited all patients with PAH who presented to our pulmonary hypertension specialty centre between 1 January 2003 and 29 December 2016. Singaporean patients on PDE5 inhibitors were included. Data recorded and analysed for this study included baseline demographics, whether the patients received MAF Plus funding, percentage of funding, and any additional source of subsidies. RESULTS: 114 (77.0%) of 148 patients in the registry were Singapore citizens on PDE5 inhibitors. 75 (65.8%) of these 114 patients had been seen by a medical social worker, of whom 16 were on MAF Plus funding. 14 of the remaining 59 patients were subsidised by MediFund, whereas the remainder were self-paying. 30 (26.3%) patients in total were on some form of subsidy, and 28 (24.6%) patients were on combination therapy. Of this group, nine were receiving MAF Plus subsidies. CONCLUSION: Fewer than expected patients were found to be receiving drug subsidies for PAH. This was partly due to insufficient referrals and lack of requests for financial assistance. Patients on combination therapy had greater financial challenges. This study should spur us on to study funding gaps further and address them.


Assuntos
Comportamento de Busca de Ajuda , Hipertensão Arterial Pulmonar , Nucleotídeo Cíclico Fosfodiesterase do Tipo 5 , Humanos , Inibidores da Fosfodiesterase 5/economia , Inibidores da Fosfodiesterase 5/uso terapêutico , Hipertensão Arterial Pulmonar/tratamento farmacológico , Doenças Raras
2.
Ann Acad Med Singap ; 49(7): 423-433, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33000105

RESUMO

INTRODUCTION: Singapore has the world's second most efficient healthcare system while costing less than 5% GDP. It remains unclear whether transcatheter aortic valve implantation (TAVI) is cost-effective for treating intermediate-low risk severe aortic stenosis (AS) patients in a highly efficient healthcare system. MATERIALS AND METHODS: A two-phase economic model combining decision tree and Markov model was developed to assess the costs, effectiveness, and the incremental cost-effectiveness ratio (ICER) of transfemoral (TF) TAVI versus surgical aortic valve replacement (SAVR) in intermediate-low risk patients over an 8-year time horizon. Mortality and complications rates were based on PARTNER 2 trial cohort A and Singapore life table. Costs were mainly retrieved from Singapore National University Health System database. Health utility data were obtained from Singapore population based on the EuroQol-5D (EQ-5D). A variety of sensitivity analyses were conducted. RESULTS: In base case scenario, the incremental effectiveness of TF-TAVI versus SAVR was 0.19 QALYs. The ICER of TF-TAVI was S$33,833/QALY. When time horizon was reduced to 5 years, the ICER was S$60,825/QALY; when event rates from the propensity analysis was used, the ICER was S$21,732/QALY and S$44,598/QALY over 8-year and 5-year time horizons, respectively. At a willingness to pay threshold of S$73,167/QALY, TF-TAVI had a 98.19% probability of being cost-effective after 100,000 simulations. The model was the most sensitive to the costs of TF-TAVI procedure. CONCLUSION: TF-TAVI is a highly cost-effective option compared to SAVR for intermediate-low risk severe AS patients from a Singapore healthcare system perspective. Increased procedure experience, reduction in device cost, and technology advance may have further increased the cost-effectiveness of TF-TAVI per scenario analysis.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Análise Custo-Benefício , Humanos , Fatores de Risco , Singapura/epidemiologia , Resultado do Tratamento
3.
Pharmacoepidemiol Drug Saf ; 27(1): 87-94, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29108136

RESUMO

PURPOSE: The Singapore regulatory agency for health products (Health Sciences Authority), in performing active surveillance of medicines and their potential harms, is open to new methods to achieve this goal. Laboratory tests are a potential source of data for this purpose. We have examined the performance of the Comparison on Extreme Laboratory Tests (CERT) algorithm, developed by Ajou University, Korea, as a potential tool for adverse drug reaction detection based on the electronic medical records of the Singapore health care system. METHODS: We implemented the original CERT algorithm, comparing extreme laboratory results pre- and post-drug exposure, and 5 variations thereof using 4.5 years of National University Hospital (NUH) electronic medical record data (31 869 588 laboratory tests, 6 699 591 drug dispensings from 272 328 hospitalizations). We investigated 6 drugs from the original CERT paper and an additional 47 drugs. We benchmarked results against a reference standard that we created from UpToDate 2015. RESULTS: The original CERT algorithm applied to all 53 drugs and 44 laboratory abnormalities yielded a positive predictive value (PPV) and sensitivity of 50.3% and 54.1%, respectively. By raising the minimum number of cases for each drug-laboratory abnormality pair from 2 to 400, the PPV and sensitivity increased to 53.9% and 67.2%, respectively. This post hoc variation, named CERT400, performed particularly well for drug-induced hepatic and renal toxicities. DISCUSSION: We have demonstrated that the CERT algorithm can be applied across national boundaries. One modification (CERT400) was able to identify adverse drug reaction signals from laboratory data with reasonable PPV and sensitivity, which indicates potential utility as a supplementary pharmacovigilance tool.


Assuntos
Sistemas de Notificação de Reações Adversas a Medicamentos/organização & administração , Algoritmos , Atenção à Saúde/organização & administração , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Farmacovigilância , Sistemas de Notificação de Reações Adversas a Medicamentos/estatística & dados numéricos , Benchmarking/normas , Bases de Dados Factuais/estatística & dados numéricos , Atenção à Saúde/estatística & dados numéricos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/prevenção & controle , Registros Eletrônicos de Saúde/estatística & dados numéricos , Implementação de Plano de Saúde , Hospitais Universitários/organização & administração , Hospitais Universitários/estatística & dados numéricos , Humanos , Padrões de Referência , Singapura/epidemiologia
4.
Circ Cardiovasc Imaging ; 10(3)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28251911

RESUMO

BACKGROUND: This large multicenter, international bicuspid aortic valve (BAV) registry aimed to define the sex differences in prevalence, valve morphology, dysfunction (aortic stenosis/regurgitation), aortopathy, and complications (endocarditis and aortic dissection). METHODS AND RESULTS: Demographic, clinical, and echocardiographic data at first presentation of 1992 patients with BAV (71.5% men) were retrospectively analyzed. BAV morphology and valve function were assessed; aortopathy configuration was defined as isolated dilatation of the sinus of Valsalva or sinotubular junction, isolated dilatation of the ascending aorta distal to the sinotubular junction, or diffuse dilatation of the aortic root and ascending aorta. New cases of endocarditis and aortic dissection were recorded. There were no significant sex differences regarding BAV morphology and frequency of normal valve function. When presenting with moderate/severe aortic valve dysfunction, men had more frequent aortic regurgitation than women (33.8% versus 22.2%, P<0.001), whereas women were more likely to have aortic stenosis (34.5% versus 44.1%, P<0.001). Men had more frequently isolated dilatation of the sinus of Valsalva or sinotubular junction (14.2% versus 6.7%, P<0.001) and diffuse dilatation of the aortic root and ascending aorta (16.2% versus 7.3%, P<0.001) than women. Endocarditis (4.5% versus 2.5%, P=0.037) and aortic dissections (0.5% versus 0%, P<0.001) occurred more frequently in men. CONCLUSIONS: Although there is a male predominance among patients with BAV, men with BAV had more frequently moderate/severe aortic regurgitation at first presentation compared with women, whereas women presented more often with moderate/severe aortic stenosis compared with men. Furthermore, men had more frequent aortopathy than women.


Assuntos
Aneurisma Aórtico/epidemiologia , Dissecção Aórtica/epidemiologia , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Valva Aórtica/anormalidades , Endocardite/epidemiologia , Disparidades nos Níveis de Saúde , Doenças das Valvas Cardíacas/epidemiologia , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Austrália/epidemiologia , Doença da Válvula Aórtica Bicúspide , Canadá/epidemiologia , Ecocardiografia , Endocardite/diagnóstico por imagem , Endocardite/fisiopatologia , Europa (Continente)/epidemiologia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo , Prevalência , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA