1.
Saf Health Work ; 15(1): 114-117, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38496275

RESUMO

A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire. We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (µm). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.

2.
Front Toxicol ; 4: 892703, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35694683

RESUMO

During the synthesis of engineered nanomaterials (ENMs), various occupational exposures occur, leading to health consequences. To date, there is paucity of studies focused on modeling the deposition of nanoparticles emitted from ENMs synthesis processes. This study aimed to characterise and assess exposure to gold (AuNPs) and silver nanoparticles (AgNPs) during a synthesis process in a research laboratory in South Africa. AuNPs and AgNPs synthesis processes were monitored for an hour in a laboratory using a Scanning Mobility Particle Sizer. The monitoring was conducted at a height of 1.2-1.5 m (m) and 1.5 m away from the hood, assuming a 30 cm (cm) breathing circumference zone. Each synthesis process was monitored thrice to generate reliable point estimates, which were used to assess exposure over 8 hours. A time-weighted average concentration was calculated and compared to the derived 8-h occupational exposure limit (OEL) for AgNPs (0.19 µg/m3) and the proposed provisional nano reference value for AuNPs (20,000 particles/cm3). The Multiple-Path Particle Dosimetry model was used to calculate the deposition and retention of both AuNPs and AgNPs. NPs emitted during the synthesis process were dominant in the nuclei (79% for AuNPs and 54% for AgNPs), followed by the Aitken (12% for AuNPs and 29% for AgNPs), with fewer particles in the accumulation mode (9.2% for AuNPs and 17% for AgNPs). AuNPs and AgNPs generated during the synthesis process were determined at 1617.3 ± 102 cm3 (0.046 µg/m3) and 2,687 cm3 ± 620 (0.077 µg/m3), respectively. For the three exposure scenarios, none exceeded the occupational exposure limit for both AuNPs (provisional) and AgNPs (OEL). Workers in the synthesis laboratory are exposed to a concentration below the recommended occupational exposure limit for silver and the proposed provisional nano reference value for gold. Although, the concentrations to which laboratory workers are exposed to are below safe levels, the assessment of the lung deposition patterns indicate a high particle lung retention which raise concerns about long term safety of workers.

3.
Front Toxicol ; 3: 817454, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35295129

RESUMO

This study monitored particulates, and volatile organic compounds (VOCs) emitted from 3-D printers using acrylonitrile-butadiene-styrene copolymer (ABS) filaments at a workplace to assess exposure before and after introducing exposure mitigation measures. Air samples were collected in the printing room and adjacent corridor, and real-time measurements of ultrafine and fine particle were also conducted. Extensive physicochemical characterizations of 3-D printer emissions were performed, including real-time (size distribution, number concentration) nanoparticle characterization, size-fractionated mass distribution and concentration, as well as chemical composition for metals by ICP-MS and VOCs by GC-FID, real-time VOC monitors, and proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS). Air sampling showed low levels of total suspended particulates (TSP, 9-12.5/m3), minimal levels (1.93-4 ppm) of total volatile organic chemicals (TVOC), and formaldehyde (2.5-21.7 ppb). Various harmful gases, such as formaldehyde, acrolein, acetone, hexane, styrene, toluene, and trimethylamine, were detected at concentrations in the 1-100 ppb by PTR-TOF-MS when air sample was collected into the Tedlar bag from the front of the 3-D printer. Ultrafine particles having an average particle size (30 nm count median diameter and 71 nm mass median diameter) increased during the 3-D printing operation. They decreased to the background level after the 3-D printing operation, while fine particles continually increased after the termination of 3-D printing to the next day morning. The exposure to 3-D printer emissions was greatly reduced after isolating 3-D printers in the enclosed space. Particle number concentration measured by real-time particle counters (DMAS and OPC) were greatly reduced after isolating 3-D printers to the isolated place.

4.
Arch Toxicol ; 94(3): 773-784, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32157349

RESUMO

Recently revised OECD inhalation toxicity testing guidelines require measurements of lung burden immediately after and for periods following exposure for nanomaterials. Lung burden is a function of pulmonary deposition and retention of nanoparticles. Using lung burden studies as per OECD guidelines, it may be possible to assess clearance mechanisms of nanoparticles. In this study, male rats were exposed to silver nanoparticle (AgNP) aerosols (18.1-19.6 nm) generated from a spark generator. Exposure groups consisted of (1) control (fresh air), (2) low (31.2 ± 8.5 µg/m3), (3) moderate (81.8 ± 11.4 µg/m3), and (4) high concentrations (115.6 ± 30.5 µg/m3). Rats were exposed for 6-h/day, 5-days/week for 4 weeks (28-days) based on the revised OECD test guideline 412. Bronchoalveolar lavage (BAL) fluids were collected on post-exposure observation (PEO)-1 and PEO-7 days and analyzed for inflammatory cells and inflammatory biomarkers. The lung burdens of Ag from AgNPs were measured on PEO-1, PEO-7, and PEO-28 days to obtain quantitative mass concentrations per lung. Differential counting of blood cells and inflammatory biomarkers in BAL fluid and histopathological evaluation of lung tissue indicated that exposure to the high concentrations of AgNP aerosol induced inflammation at PEO-1, slowly resolved at PEO-7 and completely resolved at PEO-28 days. Lung burden measurement suggested that Ag from AgNPs was cleared through two different modes; fast and slow clearance. The fast clearance component was concentration-dependent with half-times ranging from two to four days and clearance rates of 0.35-0.17/day-1 from low to high concentrations. The slow clearance had half-times of 100, 57, and 76 days and clearance rates of 0.009, 0.012, and 0.007/day-1 for the high, moderate and low concentration exposure. The exact mechanism of clearance is not known currently. The fast clearance component which was concentration-dependent could be dependent on the dissolution of AgNPs and the slow clearance would be due to slow clearance of the low dissolution AgNPs secondary particles originating from silver ions reacting with biogenic anions. These secondary AgNPs might be cleared by mechanisms other than dissolution such as mucociliary escalation, translocation to the lymphatic system or other organs.


Assuntos
Exposição por Inalação/análise , Nanopartículas Metálicas/análise , Prata/metabolismo , Aerossóis , Animais , Líquido da Lavagem Broncoalveolar , Masculino , Taxa de Depuração Metabólica , Nanopartículas Metálicas/toxicidade , Tamanho da Partícula , Ratos , Prata/toxicidade
5.
Toxicol Mech Methods ; 29(2): 95-109, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30113242

RESUMO

This paper introduces a new standardized testing procedure for nanomaterial environmental toxicity (International Organization for Standardization/Technical Specification (ISO/TS) 20787): 'aquatic toxicity assessment of manufactured nanomaterials in saltwater lakes using Artemia sp. Nauplii' intended to generate more reliable and repeatable aquatic toxicity data testing manufactured nanomaterials, using Artemia sp., to evaluate their possible ecotoxicity in saltwater lake ecosystems. The principles behind testing with Artemia sp. are reviewed and the paper gives an overview of research published between 2009 and 2018 in which manufactured nanomaterials were tested using Artemia sp.


Assuntos
Artemia/efeitos dos fármacos , Monitoramento Ambiental/métodos , Lagos/química , Manufaturas/toxicidade , Nanoestruturas/toxicidade , Testes de Toxicidade/métodos , Poluentes Químicos da Água/toxicidade , Animais , Monitoramento Ambiental/normas , Reprodutibilidade dos Testes , Medição de Risco , Salinidade , Testes de Toxicidade/normas
6.
Environ Toxicol Chem ; 37(12): 2972-2988, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30117187

RESUMO

The experimental determination of bioaccumulation is challenging, and a number of approaches have been developed for its prediction. It is important to assess the applicability of these predictive approaches to nanomaterials (NMs), which have been shown to bioaccumulate. The octanol/water partition coefficient (KOW ) may not be applicable to some NMs that are not found in either the octanol or water phases but rather are found at the interface. Thus the KOW values obtained for certain NMs are shown not to correlate well with the experimentally determined bioaccumulation. Implementation of quantitative structure-activity relationships (QSARs) for NMs is also challenging because the bioaccumulation of NMs depends on nano-specific properties such as shape, size, and surface area. Thus there is a need to develop new QSAR models based on these new nanodescriptors; current efforts appear to focus on digital processing of NM images as well as the conversion of surface chemistry parameters into adsorption indices. Water solubility can be used as a screening tool for the exclusion of NMs with short half-lives. Adaptation of fugacity/aquivalence models, which include physicochemical properties, may give some insights into the bioaccumulation potential of NMs, especially with the addition of a biota component. The use of kinetic models, including physiologically based pharmacokinetic models, appears to be the most suitable approach for predicting bioaccumulation of NMs. Furthermore, because bioaccumulation of NMs depends on a number of biotic and abiotic factors, it is important to take these factors into account when one is modeling bioaccumulation and interpreting bioaccumulation results. Environ Toxicol Chem 2018;37:2972-2988. © 2018 SETAC.


Assuntos
Monitoramento Ambiental , Nanoestruturas/análise , Cinética , Modelos Teóricos , Relação Quantitativa Estrutura-Atividade , Água/química
8.
Nanotoxicology ; 10(7): 945-56, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26982810

RESUMO

With the increased production and widespread commercial use of silver nanoparticles (AgNPs), human and environmental exposures to silver nanoparticles are inevitably increasing. In particular, persons manufacturing and handling silver nanoparticles and silver nanoparticle containing products are at risk of exposure, potentially resulting in health hazards. While silver dusts, consisting of micro-sized particles and soluble compounds have established occupational exposure limits (OELs), silver nanoparticles exhibit different physicochemical properties from bulk materials. Therefore, we assessed silver nanoparticle exposure and related health hazards in order to determine whether an additional OEL may be needed. Dosimetric evaluations in our study identified the liver as the most sensitive target organ following inhalation exposure, and as such serves as the critical target organ for setting an occupational exposure standard for airborne silver nanoparticles. This study proposes an OEL of 0.19 µg/m(3) for silver nanoparticles derived from benchmark concentrations (BMCs) from subchronic rat inhalation toxicity assessments and the human equivalent concentration (HEC) with kinetic considerations and additional uncertainty factors. It is anticipated that this level will protect workers from potential health hazards, including lung, liver, and skin damage.


Assuntos
Exposição por Inalação/análise , Nanopartículas Metálicas/toxicidade , Modelos Teóricos , Exposição Ocupacional/análise , Prata/toxicidade , Aerossóis , Animais , Benchmarking , Poeira/análise , Humanos , Exposição por Inalação/efeitos adversos , Fígado/efeitos dos fármacos , Pulmão/efeitos dos fármacos , Nanopartículas Metálicas/química , Exposição Ocupacional/efeitos adversos , Tamanho da Partícula , Ratos , Prata/química , Pele/efeitos dos fármacos
9.
Nanotoxicology ; 9(6): 802-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25395166

RESUMO

While many in vivo and in vitro toxicology studies of multi-walled carbon nanotubes (MWCNTs) have already indicated that exposure to MWCNTs can potentially induce health effects in humans, the actual health effects of MWCNTs among exposed workers are not yet known. Moreover, the levels of exposure and internal doses of MWCNTs are becoming more and more important for estimating the health effects resulting from exposure to MWCNTs. However, information on biomonitoring and exposure to MWCNTs remains limited. Therefore, the authors conducted a health surveillance study in a workplace that manufactures MWCNTs, including assessment of the personal and area exposure levels to MWCNTs, a walk-through evaluation of the manufacturing process, and collection of blood and exhaled breath condensates (EBCs) from the MWCNT manufacturing and office workers. In addition, a pulmonary function test was also conducted on the MWCNT manufacturing workers (9) and office workers (4). The worker exposure to elemental carbon was found to be 6.2-9.3 µg/m(3) in the personal samplings and 5.5-7.3 µg/m(3) in the area samplings. Notwithstanding, the workers exhibited a normal range of hematology and blood biochemistry values and normal lung function parameters. When analyzing the EBCs, the malondialdehyde (MDA), 4-hydroxy-2-hexenal (4-HHE) and n-hexanal levels in the MWCNT manufacturing workers were significantly higher than those in the office workers. The MDA and n-hexanal levels were also significantly correlated with the blood molybdenum concentration, suggesting MDA, n-hexanal and molybdenum as useful biomarkers of MWCNT exposure.


Assuntos
Indicadores Básicos de Saúde , Exposição por Inalação , Nanotubos de Carbono/toxicidade , Exposição Ocupacional , Saúde Ocupacional , Local de Trabalho/organização & administração , Adulto , Biomarcadores/análise , Feminino , Humanos , Exposição por Inalação/efeitos adversos , Exposição por Inalação/análise , Masculino , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Saúde Ocupacional/normas , Testes de Função Respiratória , Local de Trabalho/normas
10.
Ind Health ; 52(2): 152-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24366536

RESUMO

Nanosilica is one of the most widely used nanomaterials across the world. However, their assessment data on the occupational exposure to nanoparticles is insufficient. The present study performed an exposure monitoring in workplace environments where synthetic powders are prepared using fumed nanosilica. Furthermore, after it was observed during exposure monitoring that nanoparticles were emitted through leakage in a vacuum cleaner (even with a HEPA-filter installed in it), the properties of the leaked nanoparticles were also investigated. Workers were exposed to high-concentration nanosilica emitted into the air while pouring it into a container or transferring the container. The use of a vacuum cleaner with a leak (caused by an inadequate sealing) was found to be the origin of nanosilica dispersion in the indoor air. While the particle size of the nanosilica that emitted into the air (during the handling of nanosilica by a worker) was mostly over 100 nm or several microns (µm) due to the coagulation of particles, the size of nanosilica that leaked out of vacuum cleaner was almost similar to the primary size (mode diameter 11.5 nm). Analysis of area samples resulted in 20% (60% in terms of peak concentration) less than the analysis of the personals sample.


Assuntos
Nanopartículas/efeitos adversos , Exposição Ocupacional/efeitos adversos , Dióxido de Silício/efeitos adversos , Equipamentos e Provisões/efeitos adversos , Humanos , Indústria Manufatureira , Microscopia Eletrônica de Varredura , Nanopartículas/ultraestrutura , Tamanho da Partícula , Medição de Risco , Local de Trabalho
11.
Inhal Toxicol ; 25(8): 426-34, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23808635

RESUMO

Printed electronics uses converging technologies, such as printing, fine mechanics, nanotechnology, electronics and other new technologies. Consequently, printed electronics raises additional health and safety concerns to those experienced in the traditional printing industry. This study investigated two printed electronics workplaces based on a walk-through survey and personal and area sampling. All the printed electronics operations were conducted in a cleanroom. No indication of exposure to excess silver nanoparticles or carbon nanotubes (CNTs) was found. While the organic solvents were lower than current occupational exposure limits, there was a lack of engineering controls, such as local exhaust ventilation, correct enclosure and duct connections. There was also an insufficient quantity of personal protective equipment, and some organic solvents not described in the safety data sheets (SDSs) were detected in the air samples. Plus, the cleaning work, a major emissions operation, was not conducted within a hood, and the cleaning waste was not properly disposed of. Therefore, the present exposure assessment results from two printed electronics workplaces suggest that the printed electronics industry needs to take note of the occupational safety and health risks and hazards already established by the traditional printing industry, along with new risks and hazards originating from converging technologies such as nanotechnology.


Assuntos
Poluentes Ocupacionais do Ar/análise , Eletrônica , Exposição por Inalação/análise , Exposição Ocupacional/análise , Impressão , Monitoramento Ambiental , Humanos , Nanopartículas/análise , Material Particulado/análise , Equipamentos de Proteção , Prata/análise , Solventes/análise , Local de Trabalho
12.
Inhal Toxicol ; 23(4): 226-36, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21456955

RESUMO

With the increased production and widespread use of nanomaterials, human and environmental exposure to nanomaterials is inevitably increasing. Therefore, this study monitored the possible exposure to nanoparticles at workplaces that manufacture nano-TiO(2) and nano-silver. To estimate the potential exposure of workers, personal sampling, area monitoring, and real-time monitoring using a scanning mobility particle sizer (SMPS) and dust monitor were conducted at workplaces where the workers handle nanomaterials. The gravimetric concentrations of TiO(2) ranged from 0.10 to 4.99 mg/m(3), which were lower than the occupational exposure limit 10 mg/m(3) set by the Korean Ministry of Labor or American Conference of Governmental Industrial Hygienists (ACGIH). Meanwhile, the silver metal concentrations ranged from 0.00002 to 0.00118 mg/m(3), which were also lower than the silver dust 0.1 mg/m(3) and silver soluble compound 0.01 mg/m(3) occupational exposure limits set by the ACGIH. The particle number concentrations at the nano-TiO(2) manufacturing workplaces ranged from 11,418 to 45,889 particles/cm(3) with a size range of 15-710.5 nm during the reaction, although the concentration decreased to 14,000 particles/cm(3) when the reaction was stopped. The particle concentrations at the TiO(2) manufacturing workplaces increased during the reactor and vacuum pump operations, and during the collection of the synthesized TiO(2) particles. Similarly, the particle concentrations at the silver nanoparticle manufacturing workplaces increased when the sodium citrates were weighed or reacted with the silver nitrates, and during the cleaning of the workplace. The number of silver nanoparticles in the samples obtained from the workplace manufacturing silver nanoparticles using induced coupled plasma ranged from 57,789 to 2,373,309 particles/cm(3) inside the reactor with an average size of 20-30 nm and 535-25,022 particles/cm(3) with a wide range of particle sizes due to agglomeration or aggregation after the release of nanoparticles into the workplace air. In contrast, the silver nanoparticles manufactured by the wet method ranged from 393 to 3526 particle/cm(3) with an average size of 50 nm. Thus, when taken together, the TiO(2) and silver nanoparticle concentrations were relatively lower than existing occupational exposure limits.


Assuntos
Monitoramento Ambiental/métodos , Nanopartículas Metálicas/análise , Exposição Ocupacional , Prata/análise , Titânio/análise , Poluentes Ocupacionais do Ar , Poeira/análise , Humanos , Exposição por Inalação/normas , Microscopia Eletrônica de Transmissão , Saúde Ocupacional , Tamanho da Partícula
13.
Toxicol Res ; 27(2): 53-60, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24278552

RESUMO

Nanotechnology is now applied to many industries, resulting in wide range of nanomaterial-containing products, such as electronic components, cosmetic, medicines, vehicles, and home appliances. Nanoparticles can be released throughout the life cycle of nanoproducts, including the manufacture, consumer use, and disposal, thereby involving workers, consumers, and the environment in potential exposure. However, there is no current consensus on the best sampling method for characterizing manufactured-nanoparticle exposure. Therefore, this report aims to provide a standard method for assessing nanoparticle exposure, including the identification of nanoparticle emission, the assessment of worker exposure, and the evaluation of exposure mitigation actions in nanomaterial-handling workplaces or research institutes.

14.
Toxicol Res ; 27(3): 137-41, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24278563

RESUMO

This study was conducted to assess the exposure risk through inhalation to baby powder for babies and adults under simulated conditions. Baby powder was applied to a baby doll and the amount of baby powder consumed per application was estimated. The airborne exposure to baby powder during application was then evaluated by sampling the airborne baby powder near the breathing zones of both the baby doll and the person applying the powder (the applicator). The average amount of baby powder consumed was 100 mg/application, and the average exposure concentration of airborne baby powder for the applicator and baby doll was 0.00527 mg/m(3) (range 0.00157~0.01579 mg/m(3)) and 0.02207 mg/m(3) (range 0.00780~ 0.04173 mg/m(3)), respectively. When compared with the Occupational Exposure Limit of 2 mg/m(3) set by the Korean Ministry of Labor and the Threshold Limit Value (TLV) of 2 mg/m(3) set by the ACGIH (American Conference of Governmental Industrial Hygienists), the exposure concentrations were much lower. Next, the exposure to asbestos-containing baby powder was estimated and the exposure risk was assessed based on the lung asbestos contents in normal humans. As a result, the estimated lung asbestos content resulting from exposure to asbestos-containing baby powder was found to be much lower than that of a normal Korean with no asbestos-related occupational history.

15.
Inhal Toxicol ; 22(5): 369-81, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20121582

RESUMO

Seven CNT (carbon nanotube) handling workplaces were investigated for exposure assessment. Personal sampling, area sampling, and real-time monitoring using an SMPS (scanning mobility particle sizer), dust monitor, and aethalometer were performed to characterize the mass exposure, particle size distribution, and particle number exposure. No workplace was found to exceed the current ACGIH (American Conference of Governmental Industrial Hygienists) TLVs (threshold limit values) and OELs (occupational exposure levels) set by the Korean Ministry of Labor for carbon black (3.5 mg/m(3)), PNOS (particles not otherwise specified; 3 mg/m(3)), and asbestos (0.1 fiber/cc). Nanoparticles and fine particles were most frequently released after opening the CVD (chemical vapor deposition) cover, followed by catalyst preparation. Other work processes that prompted nanoparticle release included spraying, CNT preparation, ultrasonic dispersion, wafer heating, and opening the water bath cover. All these operation processes could be effectively controlled with the implementation of exposure mitigation, such as engineering control, except at one workplace where only natural ventilation was used.


Assuntos
Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Nanotubos de Carbono/análise , Exposição Ocupacional/análise , Local de Trabalho , Humanos , Tamanho da Partícula , Testes de Função Respiratória , Níveis Máximos Permitidos
16.
Toxicol Res ; 26(2): 95-100, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24278511

RESUMO

Nanoparticle exposure assessment presents a unique challenge in the field of occupational and environmental health. With the commercialization of nanotechnology, exposure usually starts from the workplace and then spreads to environment and consumer exposure. This report discusses the current trends of nanoparticle exposure assessment, including the definition of nanotechnology relevant terms, essential physicochemical properties for nanomaterial characterization, current international activities related nanomaterial safety, and exposure assessment standard development for nanotechnology. Further this report describes challenges of nanoparticle exposure assessment such as background measurement, metrics of nanoparticle exposure assessment and personal sampling.

17.
J Toxicol Environ Health A ; 72(21-22): 1493-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20077223

RESUMO

Cadmium (Cd) and arsenic (As) are widely distributed in the environment and are known human carcinogens. Several studies reported that chronic exposure to Cd and As produced renal injuries in humans. As one of the mechanisms, oxidative stress was suggested to play a role in the early process of Cd- and/or As-induced tubular damage in the kidney. This study was performed to evaluate the significance of urinary biomarkers, role of oxidative stress, and effect of coexposure to environmental low-level exposure to Cd and/or As in the general population. Urine samples were collected from 290 adults (86 males and 204 females). Urinary concentrations of Cd and As were measured, and kidney biomarkers of toxicity such as beta(2)-microglobulin and N-acetyl-beta-D-glucosaminidase (NAG) activity determined in urine. Urinary malondialdehyde (MDA) and 8-hydroxy-2'-deoxyguanosine (8-OHdG) levels were measured as oxidative stress indices. The mean concentration of Cd was 1.21 microg/L, 0.84 microg/g creatinine, and As was 5.7 microg/L, 3.95 microg/g creatinine in urine. NAG, MDA, and 8-OHdG were positively correlated with both Cd and As in urine. Positive correlations were also observed between NAG and oxidative indices. The effects of coexposure to Cd and As on biomarkers are more pronounced than for exposure to each metal alone. These findings suggest that chronic exposure to low levels of Cd and/or As might produce tubular damage in the kidney through oxidative stress in humans.


Assuntos
Arsênio/toxicidade , Arsênio/urina , Cádmio/urina , Nefropatias/induzido quimicamente , Adulto , Biomarcadores , Feminino , Humanos , Masculino , Estresse Oxidativo/efeitos dos fármacos , Medição de Risco
18.
Environ Int ; 28(1-2): 35-9, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12046952

RESUMO

Recently, a worker with lung carcinoma and a metastatic brain tumor was diagnosed as having a work-related disease. He had been employed in a non-asbestos textile company for 25 years. Consequently, to identify and explore possible causative agents for lung cancer in a non-asbestos textile manufacturing company and establish a causal relationship between exposure and lung cancer, an epidemiological investigative study was conducted and the work processes the worker was engaged in were examined. Air samples were taken from the workplace and during the drilling processes, and a suspected causative material was analyzed. The study revealed that the subject had been employed in the non-asbestos textile manufacturing company for 25 years from 1973 and his responsibilities included repairing spinning machines. In particular, the subject was involved in drilling B-bushings that were used to protect against gear abrasion in the spinning machines. An analysis of the B-bushings using a transmission electron microscope equipped with an energy dispersive X-ray analyzer indicated that they contained crocidolite asbestos fibers. Air samples obtained when drilling the B-bushings clearly indicated that the subject had most likely been exposed to crocidolite fibers when installing the B-bushings in the spinning machines. The frequency and duration of the work suggested that there would be a sufficient degree of exposure to crocidolite fibers to cause lung cancer. Except for smoking and asbestos exposure, no other chemical exposure was suspected for developing lung cancer in the workplace. Smoking appeared to be more of a potentiating risk factor in conjunction with the asbestos exposure. Accordingly, this case may provide significant evidence in identifying the cause of the mesothelioma or lung carcinoma found among workers in non-asbestos textile manufacturing companies elsewhere.


Assuntos
Poluentes Ocupacionais do Ar/efeitos adversos , Asbesto Crocidolita/efeitos adversos , Neoplasias Pulmonares/etiologia , Doenças Profissionais/etiologia , Indústria Têxtil , Neoplasias Encefálicas/secundário , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Indenização aos Trabalhadores , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA