Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Materials (Basel) ; 13(24)2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33322289

RESUMO

X-ray computed tomography is one of the most promising measurement techniques for the dimensional evaluation of industrial components. However, the inherent complexity of this technology also involves important challenges. One of them is to develop surface determination algorithms capable of providing measurement results with better accuracy in any situation-for example, for single and multi-material parts, inner and outer geometries, with and without image artefacts, etc.-and reducing user influence. The surface determination is particularly complex in the case of multi-material parts, especially when they are separated by small air gaps. In previous works, two gradient-based algorithms were presented, that showed less measurement variability throughout the whole part, and reduced the computational cost and operator influence compared to threshold-based algorithms. This work focuses on the evaluation of the performance of these algorithms when used in a scenario so complex that parts of it are made of one or more materials (metal-metal and polymer-metal) with gaps inside. For this purpose, a set of multi-material reference standards is used. The presented gradient-based algorithms show measurement errors comparable to commercial threshold-based algorithms, but with the capability of obtaining accurate measurements in smaller gaps, apart from reducing the user influence on the measurement process.

2.
PLoS One ; 12(1): e0170263, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28107468

RESUMO

More than 60.000 hip arthroplasty are performed every year in Italy. Although Ultra-High-Molecular-Weight-Polyethylene remains the most used material as acetabular cup, wear of this material induces over time in vivo a foreign-body response and consequently osteolysis, pain, and the need of implant revision. Furthermore, oxidative wear of the polyethylene provoke several and severe failures. To solve these problems, highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years. In in vitro experiments, various efforts have been made to compare the wear behavior of standard PE and vitamin-E infused liners. In this study we compared the in vitro wear behavior of two different configurations of cross-linked polyethylene (with and without the add of Vitamin E) vs. the standard polyethylene acetabular cups. The aim of the present study was to validate a micro X-ray computed tomography technique to assess the wear of different commercially available, polyethylene's acetabular cups after wear simulation; in particular, the gravimetric method was used to provide reference wear values. The agreement between the two methods is documented in this paper.


Assuntos
Reagentes de Ligações Cruzadas/química , Articulação do Quadril/diagnóstico por imagem , Polietileno/química , Polietilenos/química , Microtomografia por Raio-X/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA