Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Physiol Meas ; 41(10): 10TR01, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-32947271

RESUMO

Coronavirus disease (COVID-19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is rapidly spreading across the globe. The clinical spectrum of SARS-CoV-2 pneumonia requires early detection and monitoring, within a clinical environment for critical cases and remotely for mild cases, with a large spectrum of symptoms. The fear of contamination in clinical environments has led to a dramatic reduction in on-site referrals for routine care. There has also been a perceived need to continuously monitor non-severe COVID-19 patients, either from their quarantine site at home, or dedicated quarantine locations (e.g. hotels). In particular, facilitating contact tracing with proximity and location tracing apps was adopted in many countries very rapidly. Thus, the pandemic has driven incentives to innovate and enhance or create new routes for providing healthcare services at distance. In particular, this has created a dramatic impetus to find innovative ways to remotely and effectively monitor patient health status. In this paper, we present a review of remote health monitoring initiatives taken in 20 states during the time of the pandemic. We emphasize in the discussion particular aspects that are common ground for the reviewed states, in particular the future impact of the pandemic on remote health monitoring and consideration on data privacy.


Assuntos
Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/fisiopatologia , Monitorização Fisiológica/métodos , Pneumonia Viral/diagnóstico , Pneumonia Viral/fisiopatologia , Telemedicina/métodos , COVID-19 , Infecções por Coronavirus/epidemiologia , Humanos , Pandemias , Pneumonia Viral/epidemiologia
2.
Shock ; 52(2): 174-182, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30113390

RESUMO

PURPOSE: Camera-based photoplethysmography (cbPPG) remotely detects the volume pulse of cardiac ejection in the peripheral circulation. The cbPPG signal is sourced from the cutaneous microcirculation, yields a 2-dimensional intensity map, and is therefore an interesting monitoring technique. In this study, we investigated whether cbPPG is in general sufficiently sensitive to discern hemodynamic conditions. METHODS: cbPPG recordings of 70 patients recovering from cardiac surgery were analyzed. Photoplethysmograms were processed offline and the optical pulse power (OPP) of cardiac ejection was calculated. Hemodynamic data, image intensity, and patient movements were recorded synchronously. The effects of hemodynamic parameters and measurement conditions on the patient's individual OPP variability and their actual OPP values were calculated in mixed-effects regression models. RESULTS: Mean arterial pressure (MAP), pulse pressure (PP), heart rate (HR), and central venous pressure (CVP) significantly explained the individual OPP variability. PP had the highest explanatory power (19.9%). Averaged OPP significantly increased with PP and MAP (P < 0.001, respectively) and decreased with higher HR (P = 0.024). CVP had a 2-directional, nonsignificant effect on averaged OPP. Image intensity and patient movements did significantly affect OPP. After adjustment for hemodynamic covariables and measurement conditions, the effect of PP and HR remained unchanged, whereas that of MAP vanished. CONCLUSION: cbPPG is sensitive to hemodynamic parameters in critical care patients. It is a potential application for monitoring the peripheral circulation. Its value in a clinical setting has to be determined.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Fotopletismografia/métodos , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea/fisiologia , Pressão Venosa Central/fisiologia , Cuidados Críticos , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Humanos , Microcirculação/fisiologia , Pessoa de Meia-Idade , Análise de Regressão
3.
Biomed Tech (Berl) ; 63(5): 617-634, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-29897880

RESUMO

Over the last few years, the contactless acquisition of cardiovascular parameters using cameras has gained immense attention. The technique provides an optical means to acquire cardiovascular information in a very convenient way. This review provides an overview on the technique's background and current realizations. Besides giving detailed information on the most widespread application of the technique, namely the contactless acquisition of heart rate, we outline further concepts and we critically discuss the current state.


Assuntos
Diagnóstico por Imagem/métodos , Frequência Cardíaca/fisiologia , Fotopletismografia/instrumentação , Humanos , Fotopletismografia/métodos
4.
IEEE Trans Biomed Eng ; 64(12): 2793-2802, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28362581

RESUMO

OBJECTIVE: The noninvasive fetal ECG (NI-FECG) from abdominal recordings offers novel prospects for prenatal monitoring. However, NI-FECG signals are corrupted by various nonstationary noise sources, making the processing of abdominal recordings a challenging task. In this paper, we present an online approach that dynamically assess the quality of NI-FECG to improve fetal heart rate (FHR) estimation. METHODS: Using a naive Bayes classifier, state-of-the-art and novel signal quality indices (SQIs), and an existing adaptive Kalman filter, FHR estimation was improved. For the purpose of training and validating the proposed methods, a large annotated private clinical dataset was used. RESULTS: The suggested classification scheme demonstrated an accuracy of Krippendorff's alpha in determining the overall quality of NI-FECG signals. The proposed Kalman filter outperformed alternative methods for FHR estimation achieving accuracy. CONCLUSION: The proposed algorithm was able to reliably reflect changes of signal quality and can be used in improving FHR estimation. SIGNIFICANCE: NI-ECG signal quality estimation and multichannel information fusion are largely unexplored topics. Based on previous works, multichannel FHR estimation is a field that could strongly benefit from such methods. The developed SQI algorithms as well as resulting classifier were made available under a GNU GPL open-source license and contributed to the FECGSYN toolbox.


Assuntos
Eletrocardiografia/métodos , Monitorização Fetal/métodos , Feto/fisiologia , Processamento de Sinais Assistido por Computador , Algoritmos , Feminino , Frequência Cardíaca , Humanos , Gravidez
5.
J Biomed Opt ; 22(3): 35002, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28257535

RESUMO

Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.


Assuntos
Determinação da Frequência Cardíaca/métodos , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Algoritmos , Determinação da Frequência Cardíaca/normas , Humanos , Análise de Componente Principal , Razão Sinal-Ruído , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA