Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Quant Imaging Med Surg ; 13(12): 7893-7909, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106304

RESUMO

Background: Knee tissues such as tendon, ligament and meniscus have short T2* relaxation times and tend to show little to no signal in conventional magnetic resonance acquisitions. An ultrashort echo time (UTE) technique offers a unique tool to probe fast-decaying signals in these tissues. Clinically relevant factors should be evaluated to quantify the sensitivity needed to distinguish diseased from control tissues. Therefore, the objectives of this study were to (I) quantify the repeatability of UTE-T2* relaxation time values, and (II) evaluate the effects of fat suppression and (III) knee positioning on UTE-T2* relaxation time quantification. Methods: A dual-echo, three-dimensional center-out radially sampling UTE and conventional gradient echo sequences were utilized to image gadolinium phantoms, one ex-vivo specimen, and five in-vivo subjects on a clinical 3T scanner. Scan-rescan images from the phantom and in-vivo experiments were used to evaluate the repeatability of T2* relaxation time values. Fat suppressed and non-suppressed images were acquired for phantoms and the ex-vivo specimen to evaluate the effect of fat suppression on T2* relaxation time quantifications. The effect of knee positioning was evaluated by imaging in-vivo subjects in extended and flexed positions within the knee coil and comparing T2* relaxation times quantified from tissues in each position. Results: Phantom and in-vivo measurements demonstrated repeatable T2* mapping, where the percent difference between T2* relaxation time quantified from scan-rescan images was less than 8% for the phantom and knee tissues. The coefficient of variation across fat suppressed and non-suppressed images was less than 5% for the phantoms and ex-vivo knee tissues, showing that fat suppression had a minimal effect on T2* relaxation time quantification. Knee position introduced variability to T2* quantification of the anterior cruciate ligament, posterior cruciate ligament, and patellar tendon, with percent differences exceeding 20%, but the meniscus showed a percent difference less than 10%. Conclusions: The 3D radial UTE sequence presented in this study could potentially be used to detect clinically relevant changes in mean T2* relaxation time, however, reproducibility of these values is impacted by knee position consistency between scans.

2.
PeerJ Comput Sci ; 9: e1479, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37547412

RESUMO

Building upon the foundational principles of the grid search algorithm and Monte Carlo numerical simulation, this article introduces an innovative epidemic monitoring and prevention plan. The plan offers the capability to accurately identify the sources of infectious diseases and predict the final scale and duration of the epidemic. The proposed plan is implemented in schools and society, utilizing computer simulation analysis. Through this analysis, the plan enables precise localization of infection sources for various demographic groups, with an error rate of less than 3%. Additionally, the plan allows for the estimation of the epidemic cycle duration, which typically spans around 14 days. Notably, higher population density enhances fault tolerance and prediction accuracy, resulting in smaller errors and more reliable simulation outcomes. Overall, this study provides highly valuable theoretical guidance for effective epidemic prevention and control efforts.

3.
J Neurointerv Surg ; 13(2): 130-135, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32457224

RESUMO

BACKGROUND: CT perfusion (CTP) infarct and penumbra estimations determine the eligibility of patients with acute ischemic stroke (AIS) for endovascular intervention. This study aimed to determine volumetric and spatial agreement of predicted RAPID, Vitrea, and Sphere CTP infarct with follow-up fluid attenuation inversion recovery (FLAIR) MRI infarct. METHODS: 108 consecutive patients with AIS and large vessel occlusion were included in the study between April 2019 and January 2020 . Patients were divided into two groups: endovascular intervention (n=58) and conservative treatment (n=50). Intervention patients were treated with mechanical thrombectomy and achieved successful reperfusion (Thrombolysis in Cerebral Infarction 2b/2 c/3) while patients in the conservative treatment group did not receive mechanical thrombectomy or intravenous thrombolysis. Intervention and conservative treatment patients were included to assess infarct and penumbra estimations, respectively. It was assumed that in all patients treated conservatively, penumbra converted to infarct. CTP infarct and penumbra volumes were segmented from RAPID, Vitrea, and Sphere to assess volumetric and spatial agreement with follow-up FLAIR MRI. RESULTS: Mean infarct differences (95% CIs) between each CTP software and FLAIR MRI for each cohort were: intervention cohort: RAPID=9.0±7.7 mL, Sphere=-0.2±8.7 mL, Vitrea=-7.9±8.9 mL; conservative treatment cohort: RAPID=-31.9±21.6 mL, Sphere=-26.8±17.4 mL, Vitrea=-15.3±13.7 mL. Overlap and Dice coefficients for predicted infarct were (overlap, Dice): intervention cohort: RAPID=(0.57, 0.44), Sphere=(0.68, 0.60), Vitrea=(0.70, 0.60); conservative treatment cohort: RAPID=(0.71, 0.56), Sphere=(0.73, 0.60), Vitrea=(0.72, 0.64). CONCLUSIONS: Sphere proved the most accurate in patients who had intervention infarct assessment as Vitrea and RAPID overestimated and underestimated infarct, respectively. Vitrea proved the most accurate in penumbra assessment for patients treated conservatively although all software overestimated penumbra.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , AVC Isquêmico/diagnóstico por imagem , Imagem de Perfusão/normas , Software/normas , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/terapia , Infarto Cerebral/terapia , Estudos de Coortes , Feminino , Seguimentos , Humanos , AVC Isquêmico/terapia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Reperfusão , Tomografia Computadorizada por Raios X/métodos
5.
Huan Jing Ke Xue ; 33(3): 771-6, 2012 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-22624367

RESUMO

In the light of the problem that stress vulnerability assessment in groundwater pollution risk assessment is lack of an effective quantitative system, a new system was proposed based on representative contaminants and corresponding emission quantities through the analysis of groundwater pollution sources. And quantitative method of the representative contaminants in this system was established by analyzing the three properties of representative contaminants and determining the research emphasis using analytic hierarchy process. The method had been applied to the assessment of Beijing groundwater pollution risk. The results demonstrated that the representative contaminants hazards greatly depended on different research emphasizes. There were also differences between the sequence of three representative contaminants hazards and their corresponding properties. It suggested that subjective tendency of the research emphasis had a decisive impact on calculation results. In addition, by the means of sequence to normalize the three properties and to unify the quantified properties results would zoom in or out of the relative properties characteristic of different representative contaminants.


Assuntos
Monitoramento Ambiental , Água Subterrânea/análise , Poluentes Químicos da Água/análise , China , Medição de Risco
6.
Neuroimage ; 60(4): 2107-17, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22487547

RESUMO

Despite the essential role of the brain energy generated from ATP hydrolysis in supporting cortical neuronal activity and brain function, it is challenging to noninvasively image and directly quantify the energy expenditure in the human brain. In this study, we applied an advanced in vivo(31)P MRS imaging approach to obtain regional cerebral metabolic rates of high-energy phosphate reactions catalyzed by ATPase (CMR(ATPase)) and creatine kinase (CMR(CK)), and to determine CMR(ATPase) and CMR(CK) in pure gray mater (GM) and white mater (WM), respectively. It was found that both ATPase and CK rates are three times higher in GM than WM; and CMR(CK) is seven times higher than CMR(ATPase) in GM and WM. Among the total brain ATP consumption in the human cortical GM and WM, 77% of them are used by GM in which approximately 96% is by neurons. A single cortical neuron utilizes approximately 4.7 billion ATPs per second in a resting human brain. This study demonstrates the unique utility of in vivo(31)P MRS imaging modality for direct imaging of brain energy generated from ATP hydrolysis, and provides new insights into the human brain energetics and its role in supporting neuronal activity and brain function.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Metabolismo Energético/fisiologia , Adulto , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA