Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Health Res Policy Syst ; 21(1): 114, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37915056

RESUMO

BACKGROUND: Guideline adaptation is an emerging field to provide more appropriate recommendations for local clinical practice quality and to promote global health equity. However, its utilization status, adaptation procedures, and related materials remain to be studied. METHODS: This study developed a quality improvement protocol for a study as the Development, Evaluation, and impLemenTation for guideline Adaptation (DELTA) study. Current adapted clinical practice guidelines (CPGs) will be systematically searched. Their characteristics, utilization status, and adaptation procedures will be extracted, compared, and analyzed. Whether these adapted CPGs rigorously followed the instruments and steps of adaptation frameworks will also be appraised. In addition, the advantages and limitations of current adaptation methods and their suitable application situations will be analyzed. In addition, future perspectives as DELTA series and DELTA system, aiming for comprehensively evaluating current needs for guideline adaptation and developing a unified framework and related materials were proposed to improve the acceptability, applicability, and implementation of guideline adaptation in clinical practice. The DELTA series are divided into four phases: phase I in analyzing status, characteristics, and procedures and completeness of adapted CPGs; phase II in analyzing differences, heterogeneity, and implementation between adapted and original CPGs; and phase III in collecting, analyzing, and comparing all available adaptation materials. With these research bases, an international working group will be established in phase IV and will develop unified guideline adaptation materials after Delphi consensus, including adaptation frameworks, appraisal tools and checklists, registries, and databases. DISCUSSION: Guideline adaptation has been advanced as an efficient way to guide local clinical practice. However, it still faces several major challenges. The proposed DELTA study, series, and system will further contribute to this emerging topic. TRIAL REGISTRATION:  This study has been registered by the PROSPERO international database. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=400170 .


Assuntos
Saúde Global , Melhoria de Qualidade , Humanos , Lista de Checagem , Consenso , Bases de Dados Factuais , Guias como Assunto
3.
EBioMedicine ; 96: 104794, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37696216

RESUMO

BACKGROUND: Pre-procedural computed tomography (CT) imaging assessment of the aortic valvular complex (AVC) is essential for the success of transcatheter aortic valve replacement (TAVR). However, pre-TAVR assessment is a time-intensive process, and the visual assessment of anatomical structures at the AVC shows interobserver variability. This study aimed to develop and validate a deep learning-based algorithm for pre-TAVR CT assessment and anatomical risk factor detection. METHODS: This retrospective, multicentre study used AVC CT scans to develop a deep learning-based, fully automated algorithm, which was then internally and externally validated. After loading CT scans into the algorithm, it automatically assessed the essential anatomical structure data required for TAVR planning. CT scans of 1252 TAVR candidates continuously enrolled from Fuwai Hospital were used to establish training and internal validation datasets, while CT scans of 100 patients with aortic valve disease across 19 Chinese hospitals served as an external validation dataset. The validation focused on segmentation performance, localisation and measurement accuracy of key anatomical structures, detection ability of specific anatomical risk factors, and improvement in assessment efficiency. FINDINGS: Relative to senior observers, our algorithm achieved significant consistent performance with remarkable accuracy, efficiency and ease in segmentation, localisation, and the assessment of the aortic annulus perimeter-derived diameter, and other basic planes, coronary ostia height, calcification volume, and aortic angle. The intraclass correlation coefficient values for the algorithm in the internal and external validation datasets were up to 0.998 (95% confidence interval 0.998-0.998), respectively. Furthermore, the algorithm demonstrated high alignment in detecting specific anatomical risk factors, with accuracy, sensitivity, and specificity up to 0.989 (95% CI 0.973-0.996), 0.979 (95% CI 0.936-0.995), 0.986 (95% CI 0.945-0.998), respectively. INTERPRETATION: Our algorithm efficiently performs pre-TAVR assessments by using AVC CT imaging with accuracy comparable to senior observers, potentially improving TAVR planning in clinical practice. FUNDING: National Key R&D Program of China (2020YFC2008100), CAMS Innovation Fund for Medical Sciences (2022-I2M-C&T-B-044).


Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Resultado do Tratamento
4.
J Hazard Mater ; 459: 132314, 2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37595473

RESUMO

Constructed wetlands (CWs) were responsible for the in-depth purification of wastewater, providing an ideal environment for the transport, acquisition, and dissemination of antibiotic resistance genes (ARGs). A better understanding of influencing factors and risks of ARGs in CWs was deemed indispensable. In this research, the abundance of ARGs and mobile genetic elements (MGEs) was determined to be higher in summer and spring, ranging from 53.7 to 8.51 × 106 and 30.9-6.02 × 106 copies/mL, respectively. Seasonal variation significantly influenced the abundance of ARGs and MGEs, as well as the co-occurrence patterns among ARGs, MGEs and bacteria. However, the environmental gradients, from the influent (CW01) to the effluent (CW10), did not impose significant effects on the abundance of ARGs and MGEs. Furthermore, the ratios of pathogenic bacteria to ARG hosts and ARG risks index decreased by 50.4% and 88.54% along with the environmental gradients, indicating that CWs could act as barriers to the transfer of ARGs. Partial least squares-path modeling (PLSPM) revealed that temperature was the main driving factor of ARGs, followed by MGEs, stable and differential bacteria. This finding effectively and innovatively explored the driving indicators for the variations and risks of ARGs caused by spatial-temporal variations, providing new insights into the evaluation and control of ARGs in CWs.


Assuntos
Antibacterianos , Áreas Alagadas , Medição de Risco , Antibacterianos/farmacologia , Resistência Microbiana a Medicamentos/genética , Estações do Ano
5.
J Nucl Med ; 53(11): 1786-93, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22997277

RESUMO

UNLABELLED: The dedicated murine PET (MuPET) scanner is a high-resolution, high-sensitivity, and low-cost preclinical PET camera designed and manufactured at our laboratory. In this article, we report its performance according to the NU 4-2008 standards of the National Electrical Manufacturers Association (NEMA). We also report the results of additional phantom and mouse studies. METHODS: The MuPET scanner, which is integrated with a CT camera, is based on the photomultiplier-quadrant-sharing concept and comprises 180 blocks of 13 × 13 lutetium yttrium oxyorthosilicate crystals (1.24 × 1.4 × 9.5 mm(3)) and 210 low-cost 19-mm photomultipliers. The camera has 78 detector rings, with an 11.6-cm axial field of view and a ring diameter of 16.6 cm. We measured the energy resolution, scatter fraction, sensitivity, spatial resolution, and counting rate performance of the scanner. In addition, we scanned the NEMA image-quality phantom, Micro Deluxe and Ultra-Micro Hot Spot phantoms, and 2 healthy mice. RESULTS: The system average energy resolution was 14% at 511 keV. The average spatial resolution at the center of the field of view was about 1.2 mm, improving to 0.8 mm and remaining below 1.2 mm in the central 6-cm field of view when a resolution-recovery method was used. The absolute sensitivity of the camera was 6.38% for an energy window of 350-650 keV and a coincidence timing window of 3.4 ns. The system scatter fraction was 11.9% for the NEMA mouselike phantom and 28% for the ratlike phantom. The maximum noise-equivalent counting rate was 1,100 at 57 MBq for the mouselike phantom and 352 kcps at 65 MBq for the ratlike phantom. The 1-mm fillable rod was clearly observable using the NEMA image-quality phantom. The images of the Ultra-Micro Hot Spot phantom also showed the 1-mm hot rods. In the mouse studies, both the left and right ventricle walls were clearly observable, as were the Harderian glands. CONCLUSION: The MuPET camera has excellent resolution, sensitivity, counting rate, and imaging performance. The data show it is a powerful scanner for preclinical animal study and pharmaceutical development.


Assuntos
Engenharia/métodos , Imagem Multimodal/economia , Imagem Multimodal/instrumentação , Tomografia por Emissão de Pósitrons , Sociedades , Tomografia Computadorizada por Raios X , Animais , Camundongos , Imagem Multimodal/normas , Imagens de Fantasmas , Espalhamento de Radiação , Sociedades/normas , Fatores de Tempo
6.
IEEE Trans Nucl Sci ; 57(1): 104-110, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20485539

RESUMO

A lower-cost high-sensitivity high-resolution positron emission mammography (PEM) camera is developed. It consists of two detector modules with the planar detector bank of 20 × 12 cm(2). Each bank has 60 low-cost PMT-Quadrant-Sharing (PQS) LYSO blocks arranged in a 10 × 6 array with two types of geometries. One is the symmetric 19.36 × 19.36 mm(2) block made of 1.5 × 1.5 × 10 mm(3) crystals in a 12 × 12 array. The other is the 19.36 × 26.05 mm(2) asymmetric block made of 1.5 × 1.9 × 10 mm(3) crystals in 12 × 13 array. One row (10) of the elongated blocks are used along one side of the bank to reclaim the half empty PMT photocathode in the regular PQS design to reduce the dead area at the edge of the module. The bank has a high overall crystal packing fraction of 88%, which results in a very high sensitivity. Mechanical design and electronics have been developed for low-cost, compactness, and stability purposes. Each module has four Anger-HYPER decoding electronics that can handle a count-rate of 3 Mcps for single events. A simple two-module coincidence board with a hardware delay window for random coincidences has been developed with an adjustable window of 6 to 15 ns. Some of the performance parameters have been studied by preliminary tests and Monte Carlo simulations, including the crystal decoding map and the 17% energy resolution of the detectors, the point source sensitivity of 11.5% with 50 mm bank-to-bank distance, the 1.2 mm-spatial resolutions, 42 kcps peak Noise Equivalent Count Rate at 7.0-mCi total activity in human body, and the resolution phantom images. Those results show that the design goal of building a lower-cost, high-sensitivity, high-resolution PEM detector is achieved.

7.
IEEE Trans Nucl Sci ; 56(5): 2614-2620, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20559457

RESUMO

We developed a detailed Monte Carlo simulation method to study the time resolution of detectors for time-of-flight positron emission tomography (TOF PET). The process of gamma ray interaction in detectors, scintillation light emission and transport inside the detectors, the photoelectron generation and anode signal generation in the photomultiplier tube (PMT), and the electronics process of discriminator are simulated. We tested this simulation method using published experimental data, and found that it can generate reliable results. Using this method, we simulated the time resolution for a 13 × 13 detector block of 4 × 4 × 20 mm(3) lutetium orthosilicate (LSO) crystals coupled to four 2-inch PMTs using PMT-quadrant-sharing (PQS) technology. We analyzed the effects of several factors, including the number of photoelectrons, light transport, transit time spread (TTS), and the depth of interaction (DOI). The simulation results indicated that system time resolution of 360 ps should be possible with currently available fast PMTs. This simulation method can also be used to simulate the time resolution of other detector design method.

8.
IEEE Trans Nucl Sci ; 56(5): 2621-2627, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20485510

RESUMO

In photomultiplier-quadrant-sharing (PQS) geometry for positron emission tomography applications, each PMT is shared by four blocks and each detector block is optically coupled to four round PMTs. Although this design reduces the cost of high-resolution PET systems, when the camera consists of detector panels that are made up of square blocks, half of the PMT's sensitive window remains unused at the detector panel edge. Our goal was to develop a LYSO detector panel which minimizes the unused portion of the PMTs for a low-cost, high-resolution, and high-sensitivity positron emission mammography (PEM) camera. We modified the PQS design by using elongated blocks at panel edges and square blocks in the inner area. For elongated blocks, symmetric and asymmetrical reflector patterns were developed and PQS and PMT-half-sharing (PHS) arrangements were implemented in order to obtain a suitable decoding. The packing fraction was 96.3% for asymmetric block and 95.5% for symmetric block. Both of the blocks have excellent decoding capability with all crystals clearly identified, 156 for asymmetric and 144 for symmetric and peak-to-valley ratio of 3.0 and 2.3 respectively. The average energy resolution was 14.2% for the asymmetric block and 13.1% for the symmetric block. Using a modified PQS geometry and asymmetric block design, we reduced the unused PMT region at detector panel edges, thereby increased the field-of-view and the overall detection sensitivity and minimized the undetected breast region near the chest wall. This detector design and using regular round PMT allowed building a lower-cost, high-resolution and high-sensitivity PEM camera.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA