Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Radiol ; 94(1125): 20210475, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34289324

RESUMO

OBJECTIVES: To determine biopsy device failures, causative factors, complications and sample quality of the 16G end-cut Biopince™ and side-notch Bard™ needles. METHODS: All ultrasound-guided non-targeted liver biopsies between 01/01/2016 and 31/12/2018 were included. Operator, device, number of failures, complications and repeat biopsies were recorded. Histopathology samples were reviewed for all cases of needle failure and a group with no failures, and graded "yes/no" for the presence of steatosis, inflammation and fibrosis. The pathology slides from these cases were reviewed to assess biopsy sample quality (length and portal tract number). The failure and no-failure groups were compared in terms of device type/histology, and sample quality was compared between the needle types. RESULTS: 1004 patients were included. 93.8% (n = 942) required one needle pass to obtain a sample and 6.2% (n = 62) required >1 pass due to needle failure. Total of 76 needle failures, more with end-cut than side-notch needles (8.7% vs 2.9%) (p < 0.001). No needle failures resulted in complication. The presence of liver fibrosis was associated with fewer needle failures (p = 0.036). The major complication rate was 0.4% (4/1044). A biopsy with >10 portal tracts was obtained in 90.2% of specimens > 20 mm long, compared with 66% of 16-20 mm biopsies and 21% of <16 mm biopsies. The target of >10 portal tracts was achieved in 10/26 (38.5%) of side-notch biopsies and 64/90 (71.1%) of end-cut biopsies (p = 0.004). CONCLUSION: Ultrasound-guided liver biopsy is safe and sample quality is consistently good when a core >20 mm long is obtained. The end-cut biopsy device generated reliably good quality biopsy samples; however, the needle failure rate was significantly higher than the side-cut needle. ADVANCES IN KNOWLEDGE: Ultrasound-guided liver biopsy specimen quality is consistently good when a core >20 mm long is obtained which can be achieved with a single pass using the 16G BiopinceTM end-cut needle, although the needle failure rate is significantly higher than the 16G Max-Core™ Bard™ side-notch needle.


Assuntos
Falha de Equipamento/estatística & dados numéricos , Fígado/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
2.
BMJ Open ; 7(10): e016631, 2017 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-29061610

RESUMO

OBJECTIVE: To map out the current provision of interventional oncology (IO) services in the UK. DESIGN: Cross-sectional multicentre study. SETTING: All National Health Service (NHS) trusts in England and Scottish, Welsh and Northern Ireland health boards. PARTICIPANTS: Interventional radiology (IR) departments in all NHS trusts/health boards in the UK. RESULTS: A total of 179 NHS trusts/health boards were contacted. We received a 100% response rate. Only 19 (11%) institutions had an IO lead. 144 trusts (80%) provided IO services or had a formal pathway of referral in place for patients to a recipient trust. 21 trusts (12%) had plans to provide an IO service or formal referral pathway in the next 12 months only. 14 trusts (8%) did not have a pathway of referral and no plans to implement one. 70 trusts (39%) offered supportive and disease-modifying procedures. One trust had a formal referral pathway for supportive procedures. 73 trusts (41%) provided only supportive procedures (diagnostic or therapeutic). Of these, 43 (59%) had a referral pathway for disease-modifying IO procedures, either from a regional cancer network or through IR networks and 30 trusts (41%) did not have a referral pathway for disease-modifying procedures. CONCLUSION: The provision of IO services in the UK is promising; however, collaborative networks are necessary to ensure disease-modifying IO procedures are made accessible to all patients and to facilitate larger registry data for research with commissioning of new services.


Assuntos
Serviços de Saúde/normas , Oncologia/estatística & dados numéricos , Radiologia Intervencionista/estatística & dados numéricos , Medicina Estatal/estatística & dados numéricos , Estudos Transversais , Humanos , Neoplasias/diagnóstico , Neoplasias/terapia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA