J Magn Reson Imaging ; 48(1): 160-168, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29219218

RESUMO

BACKGROUND: Rotator cuff tendons (RCTs) are challenging to image due to the "magic angle effect" and their short T2 . PURPOSE: To assess the degree of magic angle sensitivity of human RCTs and to utilize a 3D ultrashort echo time Cones sequence with magnetization transfer preparation (UTE-Cones-MT) and two-pool quantitative MT modeling with histological correlation. We hypothesized that MT parameters would be less sensitive to the magic angle compared with conventional T2 measurements. STUDY TYPE: Prospective imaging pathologic correlation. SPECIMEN: Twenty cadaveric rotator cuff tendons were imaged at five sample orientations ranging from 0-90° relative to the B0 field. FIELD STRENGTH/SEQUENCE: 3T/3D UTE-Cones-MT and Carr-Purcell-Meiboom-Gill (CPMG). ASSESSMENT: Two-pool quantitative MT modeling parameters and T2 values were calculated in regions of interest drawn by a medical physicist. Histopathological analysis was performed and mild and severe tendinopathy groups were assigned by a histopathologist and histotechnician. STATISTICAL TESTS: Coefficients of variations (CVs) were calculated for measures between the different orientations and group means were compared for each measure. RESULTS: CVs of T2 and macromolecular fractions between orientations were 26.14 ± 16.82% and 6.18 ± 2.77% (mean ± SD), respectively. T2 measurements at 0°, 27°, 70°, and 90° showed significant differences between the two histological groups (P = 0.004, 0.008, 0.003, and 0.015, respectively), but not at 55° (P = 0.611). Mean T2 value ranges between orientations for the mild and severe tendinopathy groups were 15.27-30.32 msec and 20.81-35.85 msec, respectively, showing overlap despite statistically significant differences (P = 0.003). Macromolecular fractions at all angles showed significant differences between the two groups (P < 0.0001). Mean fraction ranges between orientations for the mild and severe tendinopathy groups were 14.32-17.17% and 10.00-13.75% respectively (P < 0.0001) with no overlap. DATA CONCLUSION: Compared with T2 , macromolecular fraction obtained with the 3D UTE-Cones-MT technique is resistant to the magic angle effect and is more sensitive to RCT degeneration. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017.


Assuntos
Imageamento Tridimensional/métodos , Manguito Rotador/diagnóstico por imagem , Tendinopatia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Magnetismo , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Tendões/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA