Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int J Surg ; 28 Suppl 1: S109-13, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26718611

RESUMO

INTRODUCTION: Obesity is a strong independent risk factor of gastroesophageal reflux disease (GERD) symptoms and hiatal hernia development. Pure restrictive bariatric surgery should not be indicated in case of hiatal hernia and GERD. However it is unclear what is the real incidence of disruption of esophagogastric junction (EGJ) in patients candidate to bariatric surgery. Actually, high resolution manometry (HRM) can provide accurate information about EGJ morphology. Aim of this study was to describe the EGJ morphology determined by HRM in obese patients candidate to bariatric surgery and to verify if different EGJ morphologies are associated to GERD-related symptoms presence. METHODS: All patients underwent a standardized questionnaire for symptom presence and severity, upper endoscopy, high resolution manometry (HRM). EGJ was classified as: Type I, no separation between the lower esophageal sphincter (LES) and crural diaphragm (CD); Type II, minimal separation (>1 and < 2 cm); Type III, >2 cm separation. RESULTS: One hundred thirty-eight obese (BMI>35) subjects were studied. Ninety-eight obese patients referred at least one GERD-related symptom, whereas 40 subjects were symptom-free. According to HRM features, EGJ Type I morphology was documented in 51 (36.9%) patients, Type II in 48 (34.8%) and Type III in 39 (28.3%). EGJ Type III subjects were more frequently associated to Symptoms than EGJ Type I (38/39, 97.4%, vs. 21/59, 41.1% p < 0.001). CONCLUSIONS: Obese subjects candidate to bariatric surgery have a high risk of disruption of EGJ morphology. In particular, obese patients with hiatal hernia often refer pre-operative presence of GERD symptoms. Testing obese patients with HRM before undergoing bariatric surgery, especially for restrictive procedures, can be useful for assessing presence of hiatal hernia.


Assuntos
Junção Esofagogástrica/patologia , Refluxo Gastroesofágico/diagnóstico , Hérnia Hiatal/diagnóstico , Manometria/métodos , Obesidade/complicações , Obesidade/patologia , Adulto , Cirurgia Bariátrica , Junção Esofagogástrica/fisiopatologia , Feminino , Refluxo Gastroesofágico/etiologia , Hérnia Hiatal/etiologia , Humanos , Masculino , Obesidade/cirurgia , Estudos Prospectivos , Fatores de Risco , Inquéritos e Questionários
2.
J Gastrointest Surg ; 12(9): 1491-6, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18612705

RESUMO

INTRODUCTION: Selecting gastroesophageal reflux disease (GERD) patients for surgery on the basis of standard 24-h pH monitoring may be challenging, particularly if this investigation does not correlate with clinical symptoms. Combined multichannel intraluminal impedance pH monitoring (MII-pH) is able to physically detect each episode of intraesophageal bolus movements, enabling identification of either acid or non-acid reflux episodes and thus establish the association of the reflux with symptoms. MATERIALS AND METHODS: We prospectively assessed and reviewed data from 314 consecutive patients who underwent MII-pH for GERD not responsive or not compliant to proton pump inhibitor therapy. One hundred fifty-three patients with a minimum follow-up of 1 year constituted the study population. Clinical outcomes and satisfaction rate were collected in all patients who underwent laparoscopic Nissen-Rossetti fundoplication. Outcomes were reported for patients with normal and ineffective peristalsis and for patients with positive pH monitoring, negative pH monitoring and positive total number of reflux episodes at MII, and negative pH monitoring and normal number of reflux episodes at MII and a positive symptom index correlation with MII. RESULTS: The overall patient satisfaction rate was 98.3%. No differences were recorded in the clinical outcomes of the patients with preoperative normal and ineffective peristalsis. No differences in patients' satisfaction and clinical postoperative DeMeester symptom scoring system were noted between the groups as determined by MII-pH. CONCLUSION: MII-pH provides useful information for objective selection of patients to antireflux surgery. Nissen fundoplication provides excellent outcomes in patients with positive and negative pH and positive MII monitoring or Symptom Index association. More extensive studies are needed to definitively standardize the useful MII-pH parameters to select the patient to antireflux surgery.


Assuntos
Fundoplicatura/métodos , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/cirurgia , Laparoscopia/métodos , Seleção de Pacientes , Adulto , Análise de Variância , Impedância Elétrica , Monitoramento do pH Esofágico , Feminino , Seguimentos , Fundoplicatura/efeitos adversos , Determinação da Acidez Gástrica , Humanos , Laparoscopia/efeitos adversos , Masculino , Manometria , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Probabilidade , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA