Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Rheumatology (Oxford) ; 61(12): 4863-4874, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35293988

RESUMO

OBJECTIVES: To investigate the reliability of the OMERACT US Task Force definition of US enthesitis in SpA. METHODS: In this web exercise, based on the evaluation of 101 images and 39 clips of the main entheses of the lower limbs, the elementary components included in the OMERACT definition of US enthesitis in SpA (hypoechoic areas, entheseal thickening, power Doppler signal at the enthesis, enthesophytes/calcifications, bone erosions) were assessed by 47 rheumatologists from 37 rheumatology centres in 15 countries. Inter- and intra-observer reliability of the US components of enthesitis was calculated using Light's kappa, Cohen's kappa, Prevalence And Bias Adjusted Kappa (PABAK) and their 95% CIs. RESULTS: Bone erosions and power Doppler signal at the enthesis showed the highest overall inter-reliability [Light's kappa: 0.77 (0.76-0.78), 0.72 (0.71-0.73), respectively; PABAK: 0.86 (0.86-0.87), 0.73 (0.73-0.74), respectively], followed by enthesophytes/calcifications [Light's kappa: 0.65 (0.64-0.65), PABAK: 0.67 (0.67-0.68)]. This was moderate for entheseal thickening [Light's kappa: 0.41 (0.41-0.42), PABAK: 0.41 (0.40-0.42)], and fair for hypoechoic areas [Light's kappa: 0.37 (0.36-0.38); PABAK: 0.37 (0.37-0.38)]. A similar trend was observed in the intra-reliability exercise, although this was characterized by an overall higher degree of reliability for all US elementary components compared with the inter-observer evaluation. CONCLUSIONS: The results of this multicentre, international, web-based study show a good reliability of the OMERACT US definition of bone erosions, power Doppler signal at the enthesis and enthesophytes/calcifications. The low reliability of entheseal thickening and hypoechoic areas raises questions about the opportunity to revise the definition of these two major components for the US diagnosis of enthesitis.


Assuntos
Entesopatia , Humanos , Reprodutibilidade dos Testes , Entesopatia/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler/métodos , Internet
2.
Front Med (Lausanne) ; 9: 1090468, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36733934

RESUMO

Objectives: To investigate the inter/intra-reliability of ultrasound (US) muscle echogenicity in patients with rheumatic diseases. Methods: Forty-two rheumatologists and 2 radiologists from 13 countries were asked to assess US muscle echogenicity of quadriceps muscle in 80 static images and 20 clips from 64 patients with different rheumatic diseases and 8 healthy subjects. Two visual scales were evaluated, a visual semi-quantitative scale (0-3) and a continuous quantitative measurement ("VAS echogenicity," 0-100). The same assessment was repeated to calculate intra-observer reliability. US muscle echogenicity was also calculated by an independent research assistant using a software for the analysis of scientific images (ImageJ). Inter and intra reliabilities were assessed by means of prevalence-adjusted bias-adjusted Kappa (PABAK), intraclass correlation coefficient (ICC) and correlations through Kendall's Tau and Pearson's Rho coefficients. Results: The semi-quantitative scale showed a moderate inter-reliability [PABAK = 0.58 (0.57-0.59)] and a substantial intra-reliability [PABAK = 0.71 (0.68-0.73)]. The lowest inter and intra-reliability results were obtained for the intermediate grades (i.e., grade 1 and 2) of the semi-quantitative scale. "VAS echogenicity" showed a high reliability both in the inter-observer [ICC = 0.80 (0.75-0.85)] and intra-observer [ICC = 0.88 (0.88-0.89)] evaluations. A substantial association was found between the participants assessment of the semi-quantitative scale and "VAS echogenicity" [ICC = 0.52 (0.50-0.54)]. The correlation between these two visual scales and ImageJ analysis was high (tau = 0.76 and rho = 0.89, respectively). Conclusion: The results of this large, multicenter study highlighted the overall good inter and intra-reliability of the US assessment of muscle echogenicity in patients with different rheumatic diseases.

3.
Ann Rheum Dis ; 78(7): 967-973, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31036626

RESUMO

OBJECTIVE: To develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren's syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips. METHODS: Twenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren's syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1-5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions. RESULTS: Consensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen's kappa 0.81) and inter-reader reliability was good (Light's kappa 0.66). CONCLUSION: New definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.


Assuntos
Interpretação de Imagem Assistida por Computador/normas , Glândulas Salivares/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Ultrassonografia/normas , Consenso , Técnica Delphi , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
4.
Reumatol Clin ; 12(6): 319-322, 2016.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-26831256

RESUMO

OBJECTIVE: to compare the short-term efficacy and safety of rituximab (RTX) therapy versus anti-TNF in rheumatoid arthritis (RA) patients after discontinuation of a first anti-TNF agent. METHODS: prospective observational multicenter study in the clinical practice setting, involving patients with severe RA refractory to a first anti-TNF agent, who received either RTX or a second anti-TNF (2TNF), comparing the efficacy endpoints, EULAR response (Good/Moderate) and safety at 6 months. RESULTS: 103 patients enrolled, 82 completed 6-month follow-up, 73.7% women. Baseline data for RTX and 2TNF groups, respectively: TJC, 8.6 and 6.6; SJC, 8.8 and 7.5; DAS28 score, 5.45 (±1.28) and 5.18 (±1.21) (p=0.048), ESR, 41 and 38.7mmHg; and HAQ, 1.2 and 1.0. Improvement was observed in all parameters, with no significant differences (except for a more marked reduction in ESR with RTX). There were no serious adverse events. CONCLUSIONS: RTX use as second-line therapy after anti-TNF failure led to improvements in the efficacy and functional variables at 6 months, with no serious adverse events. These results were comparable to those observed in patients who used a second anti-TNF agent in the same clinical scenario.


Assuntos
Adalimumab/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Etanercepte/uso terapêutico , Infliximab/uso terapêutico , Rituximab/uso terapêutico , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
5.
J Rheumatol ; 40(3): 253-60, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23322469

RESUMO

OBJECTIVE: To assess the responsiveness and repeatability of volumetric power Doppler ultrasound (PDUS) evaluation of synovitis and bone erosions in rheumatoid arthritis (RA). METHODS: Twenty-three patients with RA (19 women, mean age 52.7 ± 12.6 yrs, mean disease duration 10.1 ± 8.6 yrs) were prospectively enrolled. All patients were beginning therapy with rituximab because of disease activity despite therapy with synthetic disease-modifying antirheumatic drugs and tumor necrosis factor-blocking agents. Patients underwent clinical, laboratory, and volumetric PDUS examination at baseline, 6 months, and 12 months. Ten centers participated in the study. Four centers recruited the patients and performed the volumetric acquisitions of PDUS images, while the remaining 6 centers assessed the PDUS volumes, blinded to the identity of patients and date of the visits. The most symptomatic hand and foot were scored for B-mode synovitis, synovial PD signal, and bone erosions. The repeatability of the volumetric PDUS assessment was investigated. RESULTS: An overall improvement in clinical and PDUS measurements was found at the followup assessments. The mean indexes for synovial PD signal and bone erosions and the number of sites with abnormalities decreased significantly throughout the followup (p < 0.05). The intraacquisition, intrareader reliability was excellent for all PDUS measurements (intraclass correlation coefficients > 0.9). CONCLUSION: The results of our pilot study suggest that volumetric PDUS can be responsive and repeatable in multicenter cohort studies of RA. This technique may minimize assessment biases and reduce acquisition variability in open-label and observational studies.


Assuntos
Anticorpos Monoclonais Murinos/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/diagnóstico por imagem , Articulações/diagnóstico por imagem , Sinovite/diagnóstico por imagem , Adulto , Artrite Reumatoide/tratamento farmacológico , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Rituximab , Índice de Gravidade de Doença , Sinovite/tratamento farmacológico , Resultado do Tratamento , Ultrassonografia
6.
Arthritis Rheum ; 59(4): 515-22, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18383408

RESUMO

OBJECTIVE: To investigate the validity, reproducibility, and responsiveness of a simplified power Doppler ultrasound (PDUS) assessment of joint inflammation compared with a comprehensive 44-joint PDUS assessment in patients with rheumatoid arthritis (RA) who started therapy with a biologic agent. METHODS: A total of 160 patients with active RA who started a biologic agent were prospectively recruited in 18 Spanish centers. The patients underwent clinical and laboratory assessment and blinded PDUS examination at baseline and 6 months. A PDUS examination of 128 synovial sites in 44 joints was performed. US synovitis and PD signal were semiquantitatively graded from 1 to 3 in all synovial sites. US count and index for synovitis and PD signal were obtained. PDUS intraobserver and interobserver reliability were evaluated. A process of data reduction based on the frequency of involvement of synovial sites by both synovitis and PD signal was conducted. Construct and discriminant validity of a simplified PDUS assessment was investigated. RESULTS: A PDUS simplified assessment including 24 synovial sites from 12 joints detected 100% of patients with synovitis and 91% of patients with PD signal. There was a highly significant correlation between the 44-joint count and index for synovitis and PD signal and the 12-joint count and index for synovitis and PD signal at baseline and 6 months (r = 0.84-0.90, P < 0.0005). The smallest detectable difference was lower than the mean change in simplified PDUS variables. CONCLUSION: A 12-joint PDUS assessment of RA joint inflammation may be a valid, feasible method for multicenter monitoring of therapeutic response to biologic agents.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA