Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Res Pract Thromb Haemost ; 8(2): 102372, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38590365

RESUMO

Background: Ultrasound is increasingly used for musculoskeletal assessment in hemophilia care. Objectives: To evaluate the impact of point-of-care ultrasound added to clinical assessment for diagnosis and treatment of acute musculoskeletal episodes in a heterogeneous cohort of children and adults with hemophilia and von Willebrand disease (VWD). Methods: This prospective cross-sectional study consecutively included children and adults with hemophilia or VWD who visited the outpatient clinic with acute musculoskeletal complaints between March 2020 and May 2023. For all episodes, initial diagnosis and treatment determined by clinical assessment were recorded on a case report form. Subsequently, a physiotherapist (M.A.T. and J.B.) with knowledge of the clinical diagnosis performed point-of-care ultrasound. After ultrasound, updated diagnosis and treatment were recorded. Diagnosis and treatment before and after ultrasound were compared, and proportions of change with 95% CIs were determined. Results: We evaluated 77 episodes in 67 patients (median age, 24 years; IQR, 13-42 years). Before ultrasound, 37 joint bleeds, 13 muscle bleeds, and 27 other diagnoses were diagnosed. After ultrasound, 33 joint bleeds, 11 muscle bleeds, and 33 other diagnoses were confirmed. The diagnosis changed in 28 of 77 episodes (36%; 95% CI, 26%-48%). Nine joint bleeds and 2 muscle bleeds were missed by clinical assessment. Ultrasound findings changed treatment strategy in 30 of 77 episodes (39%; 95% CI, 28%-51%). Conclusion: Ultrasound in addition to clinical assessment of acute musculoskeletal complaints in people with hemophilia and VWD has an impact on diagnosis (36%) and treatment (39%), which supports the use of ultrasound in acute musculoskeletal complaints in hemophilia and VWD.

2.
Skeletal Radiol ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512365

RESUMO

OBJECTIVE: T2-relaxometry could differentiate between physiological and haemorrhagic joint effusion (≥ 5% blood) in vitro. Are quantitative T2-relaxation time measurements of synovial fluid feasible and reproducible in vivo in clinically bleed-free joints of men with haemophilia? MATERIALS AND METHODS: In this cross-sectional study, we measured T2-relaxation times of synovial fluid in clinically bleed-free ankles, knees or elbows of men with severe haemophilia A using a T2-mapping sequence (duration ≤ 7 min) at 3 Tesla MRI. Manual and circular regions of interest (ROI) were drawn in the synovial fluid of each joint by two independent observers to measure T2-relaxation times. Measurement feasibility was expressed as the success rate of the measurements by both observers. The interobserver and intraobserver reproducibility of the measurements were evaluated by the intraclass correlation coefficient of absolute agreement (ICC) and the limits of agreement (LoA) from Bland Altman analysis. RESULTS: We evaluated 39 clinically bleed-free joints (11 ankles, 12 knees, 16 elbows) of 39 men (median age, 24 years; range 17-33) with severe haemophilia A. The success rate of the T2-measurements was ≥ 90%. Interobserver reliability was good to excellent (manual ROI: ICC = 0.92, 95% CI 0.76-0.97; circular ROI: ICC = 0.82, 95% CI 0.66-0.91) and interobserver agreement was adequate (manual ROI: LoA = 71 ms; circular ROI: LoA = 146 ms). Intraobserver reliability was good to excellent (manual ROI: ICC = 0.78, 95% CI - 0.06-0.94; circular RO: ICC = 0.99, 95% CI 0.98-0.99) and intraobserver agreement was good (manual ROI: LoA = 63 ms; circular ROI: LoA = 41 ms). CONCLUSION: T2-relaxometry of synovial fluid in haemophilia patients is feasible with good interobserver and intraobserver reproducibility.

3.
Eur Heart J Open ; 3(1): oead001, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36751560

RESUMO

Aims: Coarctation of the aorta (CoA) is characterized by a central arteriopathy resulting in increased arterial stiffness. The condition is associated with an increased risk of stroke. We aimed to assess the aortic and cerebral haemodynamics and the presence of vascular brain injury in patients with previous surgical CoA repair. Methods and results: Twenty-seven patients with CoA (median age 22 years, range 12-72) and 25 age- and sex-matched controls (median age 24 years, range 12-64) underwent 3 T (heart, aorta, and brain) and 7 T (brain) magnetic resonance imaging scans. Haemodynamic parameters were measured using two-dimensional phase-contrast images of the ascending and descending aorta, internal carotid artery (ICA), basilar artery (BA), middle cerebral artery (MCA), and perforating arteries. Vascular brain injury was assessed by rating white matter hyperintensities, cortical microinfarcts, lacunes, and microbleeds. Pulse wave velocities in the aortic arch and descending aorta were increased and ascending aortic distensibility was decreased in patients with CoA vs. controls. Patients with CoA showed a higher mean flow velocity in the right ICA, left ICA, and BA and a reduced distensibility in the right ICA, BA, and left MCA. Haemodynamic parameters in the perforating arteries, total cerebral blood flow, intracranial volumes, and vascular brain injury were similar between the groups. Conclusion: Patients with CoA show an increased flow velocity and reduced distensibility in the aorta and proximal cerebral arteries, which suggests the presence of a generalized arteriopathy that extends into the cerebral arterial tree. No substantial vascular brain injury was observed in this relatively young CoA population, although the study was inadequately powered regarding this endpoint.

4.
Eur J Radiol ; 142: 109879, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34343845

RESUMO

BACKGROUND: Skeletal muscle mass (SMM) determined on computed tomography (CT) is emerging as a novel imaging biomarker. Cross-sectional area (CSA) of SMM at the level of the third lumbar vertebra (L3) on abdominal imaging is considered the clinical reference standard for measuring SMM. In certain patient groups, such as those with oncological or non-oncological lung disease like COVID-19, a chest CT may be available while an abdominal CT is not. The purpose of this study was to investigate whether determining SMM on a chest CT is a feasible alternative to abdominal CT. RESEARCH QUESTION: What is the correlation between SMM measurements at the level of L3 and the level of the fourth thoracic vertebra (Th4)? STUDY DESIGN AND METHODS: In this study we retrospectively analyzed abdominal and thoracic series of whole-body CT-scans of trauma patients (N = 47) and head and neck cancer patients (N = 194). All abdominal muscles were delineated on a single axial slice at the level of L3. The erector spinae, levator scapulae, rhomboideus minor and major and pectoralis minor and major muscles were delineated on a single axial slice at the level of Th4. CSA of the muscles at Th4 and the L3 level were compared using linear regression, and a multivariate linear regression model was established. RESULTS: Muscle CSA at level Th4 strongly correlates with L3 muscle CSA (r = 0.791, p < 0.05). A multivariate model incorporating the patient characteristics arm positioning, age, sex, and weight achieved a stronger correlation (r = 0.856, p < 0.05). INTERPRETATION: Skeletal muscle CSA measured at the level of Th4 is a feasible alternative to measurements at L3. This allows diagnosing low SMM using clinically available thoracic CT-scans. SMM measurements at the level of Th4 may become a prognostic or triage tool when faced with mechanical ventilator shortage.


Assuntos
COVID-19 , Sarcopenia , Estudos de Viabilidade , Humanos , Músculo Esquelético , Músculos Paraespinais/diagnóstico por imagem , Estudos Retrospectivos , SARS-CoV-2 , Vértebras Torácicas/diagnóstico por imagem
5.
Eur J Radiol ; 112: 200-206, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777211

RESUMO

Interstitial lung disease (ILD) is highly prevalent in collagen vascular diseases and reduction of ILD is an important therapeutic target. To that end, reliable quantification of pulmonary disease severity is of great significance. This study systematically reviewed the literature on automated computed tomography (CT) quantification methods for assessing ILD in collagen vascular diseases. PRISMA-DTA guidelines for systematic reviews were used and 19 original research articles up to January 2018 were included based on a MEDLINE/Pubmed and Embase search. Quantitative CT methods were categorized as histogram assessment (12 studies) or pattern/texture recognition (7 studies). R2 for correlation with visual ILD scoring ranged from 0.143 (p < 0.01) to 0.687 (p < 0.0001), for FVC from 0.048 (p < 0.0001) to 0.504 (p < 0.0001) and for DLCO from 0.015 (p = 0.61) to 0.449 (p < 0.0001). Automated CT methods are independent of reader's expertise and are a promising tool in the quantification of ILD in collagen vascular disease patients.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Vasculares/diagnóstico por imagem , Doenças do Colágeno/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
6.
Eur Radiol ; 28(1): 143-150, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28695359

RESUMO

OBJECTIVE: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). METHODS: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. RESULTS: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. CONCLUSIONS: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)-60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. KEY POINTS: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40-60% reduced dose.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sistema Urinário/diagnóstico por imagem
7.
J Cardiovasc Comput Tomogr ; 10(3): 242-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26857421

RESUMO

BACKGROUND: Stroke after cardiac surgery is a severe complication with a persistently high incidence of 1.4 - 9.7%. Postoperative strokes are mainly embolic and can be provoked by manipulation and clamping of the aorta during cardiac surgery, resulting in the mobilization of atherothrombotic material and calcifications from the aortic wall. Computed tomography (CT) can offer preoperative visualization of aortic calcifications with low radiation exposure. We hypothesize that preoperative knowledge regarding the location and extent of aortic calcifications can be used to optimize surgical strategy and decrease postoperative stroke rate. METHODS/DESIGN: The CRICKET study (ultra low-dose chest CT with iterative reconstructions as an alternative to conventional chest x-ray prior to heart surgery) is a prospective multicenter randomized clinical trial to evaluate whether non-contrast chest CT before cardiac surgery can decrease postoperative stroke rate by optimizing surgical strategy. Patients scheduled to undergo cardiac surgery aged 18 years and older are eligible for inclusion. Exclusion criteria are pregnancy, a chest/cardiac CT in the past three months, emergency surgery, concomitant or prior participation in a study with ionizing radiation and unwillingness to be informed about incidental findings. Subjects (n = 1.724) are randomized between routine care, including a chest x-ray, or routine care with an additional low dose chest CT. The primary objective is to investigate whether the postoperative in-hospital stroke rate is reduced in the CT arm compared to the routine care arm of the randomized trial. The secondary outcome measures are altered surgical approach based on CT findings and cost-effectiveness.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Procedimentos Cirúrgicos Cardíacos , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Cuidados Pré-Operatórios/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Calcificação Vascular/diagnóstico por imagem , Doenças da Aorta/complicações , Doenças da Aorta/economia , Aortografia/efeitos adversos , Aortografia/economia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/economia , Protocolos Clínicos , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/economia , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Tomografia Computadorizada Multidetectores/efeitos adversos , Tomografia Computadorizada Multidetectores/economia , Países Baixos , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/economia , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/economia , Projetos de Pesquisa , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Calcificação Vascular/complicações , Calcificação Vascular/economia
8.
J Comput Assist Tomogr ; 38(2): 185-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625611

RESUMO

OBJECTIVE: The objective of this study was to evaluate coronary image quality, stenosis grade, and diagnostic confidence in patients undergoing electrocardiogram-gated thoracoabdominal multidetector computed tomographic angiography (CTA) for aortic evaluation. METHODS: Seventy-five consecutive patients underwent retrospectively electrocardiogram-gated thoracoabdominal CTA reconstructed at each 12.5% of the R wave to R wave (R-R) interval. Two observers in consensus scored the coronary arteries per segment (15-segment American Heart Association model) for image quality, stenosis grade, and stenosis-assessment confidence. RESULTS: Nondiagnostic image quality prohibited coronary evaluation in 14 patients. In the remaining patients, 2% of segments was scored absent, 24% was scored nondiagnostic, 12% was scored diagnostically limited, and 61% was scored at least acceptable. Acceptable or higher image quality was seen in 82% of the proximal and middle segments. Significant stenosis (>50%) was seen in 57% of the patients. Stenosis-severity scoring confidence was moderate to high in 79% of 673 assessable segments. CONCLUSIONS: Electrocardiogram-gated thoracoabdominal CTA allows concomitant assessment of the proximal and middle coronary arteries and may serve as a combined tool for aortic-disease workup. Aortic CTA showed significant coronary artery stenosis in 57% of the patients evaluated for aortic pathology.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
9.
Int J Cardiovasc Imaging ; 30(1): 155-63, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24046026

RESUMO

To compare coronary plaque size and composition as well as degree of coronary artery stenosis on coronary Computed Tomography angiography (CCTA) using three levels of iterative reconstruction (IR) with standard filtered back projection (FBP). In 63 consecutive patients with a clinical indication for CCTA 55 coronary plaques were analysed. Raw data were reconstructed using standard FBP and levels 2, 4 and 6 of a commercially available IR algorithm (iDose(4)). CT attenuation and noise were measured in the aorta and two coronary arteries. Both signal-to-noise-ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The amount of lipid, fibrous and calcified plaque components and mean cross-sectional luminal area were analysed using dedicated software. Image noise was reduced by 41.6% (p < 0.0001) and SNR and CNR in the aorta were improved by 73.4% (p < 0.0001) and 72.9% (p < 0.0001) at IR level 6, respectively. IR improved objective image quality measures more in the aorta than in the coronary arteries. Furthermore, IR had no significant effect on measurements of plaque volume and cross-sectional luminal area. The application of IR significantly improves objective image quality, and does not alter quantitative analysis of coronary plaque volume, composition and luminal area.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Placa Aterosclerótica , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Algoritmos , Doença da Artéria Coronariana/metabolismo , Estenose Coronária/metabolismo , Vasos Coronários/química , Feminino , Fibrose , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Razão Sinal-Ruído , Calcificação Vascular/diagnóstico por imagem
10.
Ned Tijdschr Geneeskd ; 157(46): A7019, 2013.
Artigo em Holandês | MEDLINE | ID: mdl-24220184

RESUMO

Screening for lung cancer with computed tomography (CT) appears to be highly effective. A large randomized trial in the United States reported a 7% reduction in all-cause mortality in patients screened by CT in comparison with those screened by chest radiography. The problem of dealing with the large number of pulmonary nodules and false positive test results could be solved by a protocol from the Dutch-Belgian lung cancer screening trial which proposes a strategy based on nodule volume and volumetry. Additional findings related to chronic obstructive pulmonary disease and cardiovascular disease are common in lung cancer screening and may provide an opportunity to increase screening benefits at minimal cost in the future. As CT is superior to radiography in lung cancer detection, CT seems the preferred imaging modality for case finding. As more trial results have to be awaited and cost-effectiveness and optimal screening strategy remain uncertain, CT lung cancer screening is not yet ready for implementation.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Análise Custo-Benefício , Detecção Precoce de Câncer , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/mortalidade , Radiografia Torácica , Tomografia Computadorizada por Raios X/economia , Estados Unidos
11.
PLoS One ; 8(8): e71204, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23940719

RESUMO

OBJECTIVES: To evaluate the reliability of semiquantitative Vertebral Fracture Assessment (VFA) on chest Computed Tomography (CT). METHODS: Four observers performed VFA twice upon sagittal reconstructions of 50 routine clinical chest CTs. Intra- and interobserver agreement (absolute agreement or 95% Limits of Agreement) and reliability (Cohen's kappa or intraclass correlation coefficient(ICC)) were calculated for the visual VFA measures (fracture present, worst fracture grade, cumulative fracture grade on patient level) and for percentage height loss of each fractured vertebra compared to the adjacent vertebrae. RESULTS: Observers classified 24-38% patients as having at least one vertebral fracture, giving rise to kappa's of 0.73-0.84 (intraobserver) and 0.56-0.81 (interobserver). For worst fracture grade we found good intraobserver (76-88%) and interobserver (74-88%) agreement, and excellent reliability with square-weighted kappa's of 0.84-0.90 (intraobserver) and 0.84-0.94 (interobserver). For cumulative fracture grade the 95% Limits of Agreement were maximally ±1,99 (intraobserver) and ±2,69 (interobserver) and the reliability (ICC) varied from 0.84-0.94 (intraobserver) and 0.74-0.94 (interobserver). For percentage height-loss on a vertebral level the 95% Limits of Agreement were maximally ±11,75% (intraobserver) and ±12,53% (interobserver). The ICC was 0.59-0.90 (intraobserver) and 0.53-0-82 (interobserver). Further investigation is needed to evaluate the prognostic value of this approach. CONCLUSION: In conclusion, these results demonstrate acceptable reproducibility of VFA on CT.


Assuntos
Radiografia Torácica , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia Torácica/estatística & dados numéricos , Reprodutibilidade dos Testes , Fraturas da Coluna Vertebral/epidemiologia , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos
13.
Eur Radiol ; 22(10): 2103-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22618522

RESUMO

OBJECTIVES: To determine the influence of iterative reconstruction (IR) on quantitative computed tomography (CT) measurements of emphysema, air trapping, and airway wall and lumen dimensions, compared to filtered back-projection (FBP). METHODS: Inspiratory and expiratory chest CTs of 75 patients (37 male, 38 female; mean age 64.0 ± 5.7 years) were reconstructed using FBP and IR. CT emphysema, CT air trapping and airway dimensions of a segmental bronchus were quantified using several commonly used quantification methods. The two algorithms were compared using the concordance correlation coefficient (p (c)) and Wilcoxon signed rank test. RESULTS: Only the E/I-ratio(MLD) as a measure of CT air trapping and airway dimensions showed no significant differences between the algorithms, whereas all CT emphysema and the other CT air trapping measures were significantly different at IR when compared to FBP (P < 0.001). CONCLUSION: The evaluated IR algorithm significantly influences quantitative CT measures in the assessment of emphysema and air trapping. However, the E/I-ratio(MLD) as a measure of CT air trapping, as well as the airway measurements, is unaffected by this reconstruction method. Quantitative CT of the lungs should be performed with careful attention to the CT protocol, especially when iterative reconstruction is introduced. KEY POINTS : • New techniques in CT allow numerous quantitative measurements of lung function. • Iterative reconstruction influences quantitative CT measurements of emphysema and air trapping. • Expiratory-to-inspiratory ratio of mean lung density and airway measurements are unaffected by iterative reconstruction. • Quantitative lung-CT should be performed with careful attention to the CT protocol.


Assuntos
Processamento de Imagem Assistida por Computador , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Chest ; 138(2): 371-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20299624

RESUMO

BACKGROUND: The prevalence and severity of structural lung disease in children with common variable immunodeficiency (CVID) disorders is not well known, and a dedicated CT scanning protocol and CT scan scoring system have not been described in this category. METHODS: This was a cohort study of 54 children (34 CVID, 20 CVID-like disorder) in a stable condition who underwent volumetric inspiratory and end-expiratory CT scans. Scans were scored for airway abnormalities, interstitial and parenchymal lung disease, and lymphadenopathy using a newly developed CT scan scoring system. Scores were normalized to a 0% to 100% scale. Observer agreement was assessed using an intraclass correlation coefficient (Ri). Prevalence and severity of CT scan abnormalities were calculated. RESULTS: Structural lung disease was common (85%-93%), but usually mild as reflected in the relatively low scores (bronchiectasis score 2.8% +/- 6.4%). Moderate-to-severe bronchiectasis was found in three (5%) patients. Expiratory air trapping was the most common finding, found in 71% to 80%, but often in a mild form; application of a cut off level of > 10% reduced its prevalence to 33% to 38%. In 9% to 15% of all patients, air trapping was the only abnormality. Multiple lung nodules were seen in 24% to 25% and could disappear after corticosteroid treatment. Observer agreement was moderate (Ri 0.6-0.79) to good (Ri > 0.8) for all items and the composite scores, except airway wall thickening. CONCLUSION: In children with CVID disorders, mild structural lung disease is common. Expiratory CT scans show the most frequent abnormality, air trapping. The occurrence of (silent) lung disease progression and the clinical impact of CT scans require further investigations.


Assuntos
Imunodeficiência de Variável Comum/complicações , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Criança , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pneumopatias/complicações , Pneumopatias/epidemiologia , Masculino
15.
Radiology ; 231(2): 434-9, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15064392

RESUMO

PURPOSE: To retrospectively compare thin-section computed tomographic (CT) scores obtained with five scoring systems for assessment of pulmonary disease in children with cystic fibrosis and to determine additional value of bronchial and arterial dimension measurements. MATERIALS AND METHODS: Scores obtained with five thin-section CT scoring systems were compared. A score of 0 indicated the absence of abnormalities; a higher score meant that more structural abnormalities were seen. Three observers assigned scores and then reassigned scores after intervals varying from 1-2 weeks to 1-2 months at review of thin-section CT scans obtained in 25 children with cystic fibrosis. Interobserver and intraobserver reliability was calculated with intraclass correlation coefficients. Quantitative measurements of bronchial and arterial dimensions were obtained. Thin-section CT scores were correlated (Spearman correlation) with bronchial and arterial dimensions and with results of pulmonary function tests (PFTs), such as forced expiratory volume in 1 second (FEV(1)). RESULTS: Scores with all five scoring systems were reproducible, with intraclass correlation coefficients of 0.74 and higher (P <.05), and showed significant correlations with FEV(1) (R = -0.73 to -0.69, P <.01). Ratio of bronchial diameter to accompanying pulmonary arterial diameter was correlated with thin-section CT scores but not with FEV(1). Ratio of bronchial wall thickness to accompanying pulmonary arterial diameter was not correlated with thin-section CT scores or PFT results. CONCLUSION: Thin-section CT scores were reproducible and were correlated with PFT results. Measurements of bronchial dimensions were not significantly related to scores or PFT results.


Assuntos
Brônquios/patologia , Fibrose Cística/complicações , Pneumopatias/diagnóstico por imagem , Pneumopatias/etiologia , Artéria Pulmonar/patologia , Tomografia Computadorizada por Raios X , Adolescente , Broncografia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA