1.
Int J Radiat Oncol Biol Phys ; 108(4): 1055-1062, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-32629078

RESUMO

PURPOSE: In a randomized focal dose escalation radiation therapy trial for prostate cancer (FLAME), up to 95 Gy was prescribed to the tumor in the dose-escalated arm, with 77 Gy to the entire prostate in both arms. As dose constraints to organs at risk had priority over dose escalation and suboptimal planning could occur, we investigated how well the dose to the tumor was boosted. We developed an anatomy-based prediction model to identify plans with suboptimal tumor dose and performed replanning to validate our model. METHODS AND MATERIALS: We derived dose-volume parameters from planned dose distributions of 539 FLAME trial patients in 4 institutions and compared them between both arms. In the dose-escalated arm, we determined overlap volume histograms and derived features representing patient anatomy. We predicted tumor D98% with a linear regression on anatomic features and performed replanning on 21 plans. RESULTS: In the dose-escalated arm, the median tumor D50% and D98% were 93.0 and 84.7 Gy, and 99% of the tumors had a dose escalation greater than 82.4 Gy (107% of 77 Gy). In both arms organs at risk constraints were met. Five out of 73 anatomic features were found to be predictive for tumor D98%. Median predicted tumor D98% was 4.4 Gy higher than planned D98%. Upon replanning, median tumor D98% increased by 3.0 Gy. A strong correlation between predicted increase in D98% and realized increase upon replanning was found (ρ = 0.86). CONCLUSIONS: Focal dose escalation in prostate cancer was feasible with a dose escalation to 99% of the tumors. Replanning resulted in an increased tumor dose that correlated well with the prediction model. The model was able to identify tumors on which a higher boost dose could be planned. The model has potential as a quality assessment tool in focal dose escalated treatment plans.


Assuntos
Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Intervalo Livre de Doença , Estudos de Viabilidade , Humanos , Bases de Conhecimento , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Modelos Teóricos , Recidiva Local de Neoplasia/sangue , Recidiva Local de Neoplasia/mortalidade , Órgãos em Risco/diagnóstico por imagem , Próstata , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/mortalidade , Neoplasias da Próstata/patologia , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reto , Reprodutibilidade dos Testes , Glândulas Seminais , Tomografia Computadorizada por Raios X , Carga Tumoral/efeitos da radiação
2.
Acta Oncol ; 59(8): 926-932, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32436450

RESUMO

Background and purpose: In this study we developed a workflow for fully-automated generation of deliverable IMRT plans for a 1.5 T MR-Linac (MRL) based on contoured CT scans, and we evaluated automated MRL planning for rectal cancer.Methods: The Monte Carlo dose calculation engine used in the clinical MRL TPS (Monaco, Elekta AB, Stockholm, Sweden), suited for high accuracy dose calculations in a 1.5 T magnetic field, was coupled to our in-house developed Erasmus-iCycle optimizer. Clinically deliverable plans for 23 rectal cancer patients were automatically generated in a two-step process, i.e., multi-criterial fluence map optimization with Erasmus-iCycle followed by a conversion into a deliverable IMRT plan in the clinical TPS. Automatically generated plans (AUTOplans) were compared to plans that were manually generated with the clinical TPS (MANplans).Results: With AUTOplanning large reductions in planning time and workload were obtained; 4-6 h mainly hands-on planning for MANplans vs ∼1 h of mainly computer computation time for AUTOplans. For equal target coverage, the bladder and bowel bag Dmean was reduced in the AUTOplans by 1.3 Gy (6.9%) on average with a maximum reduction of 4.5 Gy (23.8%). Dosimetric measurements at the MRL demonstrated clinically acceptable delivery accuracy for the AUTOplans.Conclusions: A system for fully automated multi-criterial planning for a 1.5 T MR-Linac was developed and tested for rectal cancer patients. Automated planning resulted in major reductions in planning workload and time, while plan quality improved. Negative impact of the high magnetic field on the dose distributions could be avoided.


Assuntos
Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Retais/radioterapia , Fluxo de Trabalho , Humanos , Campos Magnéticos , Método de Monte Carlo , Radiometria , Dosagem Radioterapêutica , Neoplasias Retais/diagnóstico por imagem , Tomografia Computadorizada por Raios X