Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38396467

RESUMO

OBJECTIVES: The purpose of this study was to investigate the imaging characteristics of medication-related osteonecrosis of the jaw (MRONJ) using [18F]fluoride positron emission tomography/computed tomography (PET/CT) and [18F]fluorodeoxyglucose (FDG) PET/magnetic resonance imaging (MRI) for preoperative assessment and to correlate them with microarchitectural and histomorphometric data with respect to clinical findings. METHODS: Twelve patients (five female; mean age 75 ± 7.6 yr) with symptomatic MRONJ underwent both scans on the same day, and imaging findings were used to plan surgical interventions for seven patients. Bone tracer uptake was classified as high, medium, or low, and surgical samples were evaluated using Micro-CT and histomorphometric analysis. RESULTS: CT showed medullary sclerosis in all patients, and MRI revealed gadolinium enhancement in four patients. PET imaging revealed remarkably elevated [18F]fluoride uptake and moderately increased [18F]FDG uptake in MRONJ compared to healthy jawbones, with both differences being statistically significant. [18F]fluoride uptake was associated with necrosis, bacteria, and inflammatory tissue. Micro-CT data did not show significant differences, but histomorphometric analysis revealed higher osteocyte and lacunae densities in the high [18F]fluoride uptake group, and more necrotic bone in the medium [18F]fluoride uptake group. Bacteria were observed in all areas. CONCLUSIONS: In summary, [18F]fluoride PET accurately identified MRONJ extent, revealing functional changes in jawbone remodeling not visible on CT. [18F]FDG PET showed differences in bone and soft tissue, though less pronounced. This method aids in evaluating disease activity and guiding treatment planning, requiring further research for optimal surgical approaches based on tracer uptake.

2.
EJNMMI Phys ; 9(1): 87, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36513949

RESUMO

AIM: Recently, total-body PET/CT systems with an extended axial field-of-view (aFOV) became commercially available which allow acquiring physiologic information of multiple organs simultaneously. However, the nominal aFOV may clinically not be used effectively due to the inherently reduced sensitivity at the distal ends of the aFOV. The aim of this study was to assess the extent of the useful aFOV of the Biograph Vision Quadra PET/CT system. METHODS: A NEMA image quality (IQ) phantom mimicking a standard [18F]FDG examination was used. Image contrast and noise were assessed across the 106 cm aFOV of the Biograph Vision Quadra PET/CT system (Siemens Healthineers). Phantom acquisitions were performed at different axial positions. PET data were rebinned to simulate different acquisition times for a standard injected activity and reconstructed using different filter settings to evaluate the noise and images along the axial direction. RESULTS: Image noise and contrast were stable within the central 80 cm of the aFOV. Outside this central area, image contrast variability as well as image noise increased. This degradation of IQ was in particular evident for short acquisition times of less than 30 s. At 10 min acquisition time and in the absence of post-reconstruction filtering, the useful aFOV was 100 cm. For a 2 min acquisition time, a useful aFOV with image noise below 15% was only achievable using Gaussian filtering with axial extents of between 83 and 103 cm when going from 2 to 6 mm full-width-half-maximum, respectively. CONCLUSION: Image noise increases substantially towards the ends of the aFOV. However, good IQ in compliance with generally accepted benchmarks is achievable for an aFOV of > 90 cm. When accepting higher image noise or using dedicated protocol settings such as stronger filtering a useful aFOV of around 1 m can be achieved for a 2 min acquisition time.

3.
J Clin Med ; 11(14)2022 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-35887762

RESUMO

To investigate imaging features of osteomyelitis of the jaw (OMJ) using [18F]fluoride positron emission tomography (PET) and [18F]fluorodeoxyglucose (FDG)-PET compared with computed tomography (CT) and magnetic resonance imaging (MRI) to assess extent and disease activity. Six female patients (55.3 ± 10.0 years) were enrolled for assessment of symptomatic OMJ. 4/6 patients underwent [18F]FDG-PET/MRI and [18F]fluoride-PET/CT, one patient MRI and [18F]fluoride-PET/CT and another patient only [18F]FDG-PET/MRI. Image analysis was performed by two radiologists, an oral and maxillofacial surgeon, and a nuclear medicine specialist. The extent of affected jawbone was analyzed both qualitatively and quantitatively, including the PET tracer uptake, CT-Hounsfield-Units (HU) and MRI parameters in affected and healthy jawbone. All patients had trabecular sclerosis in the affected jawbone compared to healthy jawbone (560 ± 328 HU vs. 282 ± 211 HU; p > 0.05), while 3/6 patients had cortical erosions. Bone marrow edema and gadolinium enhancement were documented in 5/6 patients. In affected jawbone, [18F]fluoride-uptake was increased in all patients compared to healthy jawbone (SUVmean 15.4 ± 4.2 vs. 2.1 ± 0.6; p < 0.05), and [18F]FDG-uptake was moderately higher (SUVmean 1.9 ± 0.7 vs. 0.7 ± 0.2; p > 0.05). The extent of regions with increased metabolic activity was less than the extent of morphologic changes in all patients. Information on jawbone metabolism and inflammation is different from morphologic changes and therefore has the potential to provide a more accurate and objective assessment of the extent and activity of OMJ.

4.
Diagnostics (Basel) ; 11(8)2021 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-34441395

RESUMO

We report the case of a 6-year-old patient with suspected recurrence of a plunging ranula in clinical and ultrasonographic examination. Surgical resection of the left submandibular and sublingual glands had already been performed. Since persistent glandular tissue could not be excluded with certainty via MRI, we expanded diagnostics by performing a PET/MRI using a head and neck imaging protocol and the radiotracer 18F-PSMA-1007, which is physiologically expressed by salivary gland tissue. The 18F-PSMA-PET/MRI provided evidence of a cystically transformed, diminishing seroma in the left retro-/submandibular region. No 18F-PSMA expressing glandular tissue could be detected in the area of resection, excluding a relapse of a plunging ranula. As a consequence, we opted for a conservative treatment without further surgical intervention. We conclude that a simultaneous 18F-PSMA-PET/MRI is a comprehensive imaging modality, which can help to rule out persistent salivary tissue and recurring plunging ranula. It is a useful tool to facilitate the decision making of surgical interventions.

5.
J Nucl Med ; 60(10): 1359-1365, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30850491

RESUMO

Biochemical recurrence (BCR) after prostate cancer surgery is common, even after additional salvage radiotherapy. BCR might be explained by target miss. Improved diagnostic accuracy provided by PET could potentially circumvent this therapeutic gap. Therefore, we evaluated consecutive 68Ga-prostate-specific membrane antigen (PSMA) PET/CT, 11C-choline PET/CT, and standard CT imaging in the same patient with regard to TNM-stage migration and accordingly adapted curative radiotherapy options including ablative treatment of oligometastases (n ≤ 5). The cost efficacy of PET- versus CT-based treatment was also calculated. Methods: The prospective register database (064/2013BO1) was retrospectively searched for patients fulfilling the following 3 inclusion criteria: BCR after radical prostatectomy (pT2-pT4 pN0-pN1 cM0, postoperative radiotherapy allowed); 11C-choline PET/CT, 68Ga-PSMA PET/CT, and diagnostic CT performed within 24 h; and available clinical data. Ten treatment routines were defined according to current practice. Furthermore, intention-to-treat and treatment-related costs depending on the shift of TNM stage after imaging were analyzed. Eighty-three patients were eligible (median prostate-specific antigen level, 1.9 ng/mL). Results: Both PET examinations led to concordant results in 72% of patients, whereas the concordance of TNM staging between 68Ga-PSMA PET and diagnostic CT was only 36%. Incorrect staging would lead to "wrong" treatment and therefore to additional costs. A 68Ga-PSMA PET study would be cost-effective if additional costs do not exceed €3,844 ($4,312) (vs. CT). The number needed to image was 2 (for CT) and 4 (for 11C-choline PET) to avoid 1 incorrect treatment. In addition, 68Ga-PSMA PET staging enabled new curative options in half the patients with previous radiotherapy who otherwise receive palliative androgen deprivation therapy. Conclusion:68Ga-PSMA PET/CT is cost-effective in all patients with regard to avoidance of incorrect treatment. It enabled new curative options for patients with previous radiotherapy who are usually treated palliatively. Therefore, 68Ga-PSMA PET/CT staging should become standard for BCR after surgery with or without radiotherapy.


Assuntos
Colina/análogos & derivados , Glicoproteínas de Membrana/farmacologia , Compostos Organometálicos/farmacologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Colina/farmacologia , Análise Custo-Benefício , Bases de Dados Factuais , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Satisfação do Paciente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/economia , Período Pós-Operatório , Prostatectomia , Neoplasias da Próstata/economia , Neoplasias da Próstata/cirurgia , Radioterapia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
6.
Neuro Oncol ; 21(Suppl 1): i44-i61, 2019 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-30649491

RESUMO

The archetypal imaging characteristics of meningiomas are among the most stereotypic of all central nervous system (CNS) tumors. In the era of plain film and ventriculography, imaging was only performed if a mass was suspected, and their results were more suggestive than definitive. Following more than a century of technological development, we can now rely on imaging to non-invasively diagnose meningioma with great confidence and precisely delineate the locations of these tumors relative to their surrounding structures to inform treatment planning. Asymptomatic meningiomas may be identified and their growth monitored over time; moreover, imaging routinely serves as an essential tool to survey tumor burden at various stages during the course of treatment, thereby providing guidance on their effectiveness or the need for further intervention. Modern radiological techniques are expanding the power of imaging from tumor detection and monitoring to include extraction of biologic information from advanced analysis of radiological parameters. These contemporary approaches have led to promising attempts to predict tumor grade and, in turn, contribute prognostic data. In this supplement article, we review important current and future aspects of imaging in the diagnosis and management of meningioma, including conventional and advanced imaging techniques using CT, MRI, and nuclear medicine.


Assuntos
Neoplasias Meníngeas/diagnóstico , Meningioma/diagnóstico , Imagem Multimodal/métodos , Neuroimagem/métodos , Humanos , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/diagnóstico por imagem
7.
Bioengineering (Basel) ; 5(3)2018 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-30060546

RESUMO

Metastasized castration-resistant prostate cancer (mCRPC), is the most advanced form of prostate neoplasia, where massive spread to the skeletal tissue is frequent. Patients with this condition are benefiting from an increasing number of treatment options. However, assessing tumor response in patients with multiple localizations might be challenging. For this reason, many computational approaches have been developed in the last decades to quantify the skeletal tumor burden and treatment response. In this review, we analyzed the progressive development and diffusion of such approaches. A computerized literature search of the PubMed/Medline was conducted, including articles between January 2008 and March 2018. The search was expanded by manually reviewing the reference list of the chosen articles. Thirty-five studies were identified. The number of eligible studies greatly increased over time. Studies could be categorized in the following categories: automated analysis of 2D scans, SUV-based thresholding, hybrid CT- and SUV-based thresholding, and MRI-based thresholding. All methods are discussed in detail. Automated analysis of bone tumor burden in mCRPC is a growing field of research; when choosing the appropriate method of analysis, it is important to consider the possible advantages as well as the limitations thoroughly.

8.
Radiother Oncol ; 128(3): 485-491, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29747873

RESUMO

BACKGROUND AND PURPOSE: Functional PET/MRI has great potential to improve radiotherapy planning (RTP). However, data integration requires imaging with radiotherapy-specific patient positioning. Here, we investigated the feasibility and image quality of radiotherapy-customized PET/MRI in head-and-neck cancer (HNC) patients using a dedicated hardware setup. MATERIAL AND METHODS: Ten HNC patients were examined with simultaneous PET/MRI before treatment, with radiotherapy and diagnostic scan setup, respectively. We tested feasibility of radiotherapy-specific patient positioning and compared the image quality between both setups by pairwise image analysis of 18F-FDG-PET, T1/T2-weighted and diffusion-weighted MRI. For image quality assessment, similarity measures including average symmetric surface distance (ASSD) of PET and MR-based tumor contours, MR signal-to-noise ratio (SNR) and mean apparent diffusion coefficient (ADC) value were used. RESULTS: PET/MRI in radiotherapy position was feasible - all patients were successfully examined. ASSD (median/range) of PET and MR contours was 0.6 (0.4-1.2) and 0.9 (0.5-1.3) mm, respectively. For T2-weighted MRI, a reduced SNR of -26.2% (-39.0--11.7) was observed with radiotherapy setup. No significant difference in mean ADC was found. CONCLUSIONS: Simultaneous PET/MRI in HNC patients using radiotherapy positioning aids is clinically feasible. Though SNR was reduced, the image quality obtained with a radiotherapy setup meets RTP requirements and the data can thus be used for personalized RTP.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Posicionamento do Paciente , Estudos Prospectivos
9.
Neuro Oncol ; 18(9): 1199-208, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27106405

RESUMO

This guideline provides recommendations for the use of PET imaging in gliomas. The review examines established clinical benefit in glioma patients of PET using glucose ((18)F-FDG) and amino acid tracers ((11)C-MET, (18)F-FET, and (18)F-FDOPA). An increasing number of studies have been published on PET imaging in the setting of diagnosis, biopsy, and resection as well radiotherapy planning, treatment monitoring, and response assessment. Recommendations are based on evidence generated from studies which validated PET findings by histology or clinical course. This guideline emphasizes the clinical value of PET imaging with superiority of amino acid PET over glucose PET and provides a framework for the use of PET to assist in the management of patients with gliomas.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imagem Molecular/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Animais , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/terapia , Glioma/metabolismo , Glioma/terapia , Humanos
10.
Ann Nucl Med ; 28(2): 103-11, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24254430

RESUMO

OBJECTIVE: Dopamine transporter imaging with SPECT is a valuable tool for both clinical routine and research studies. Semi-quantitative analysis plays a key role in interpreting the scans, but is dependent on numerous factors, rotational radius being one of them. This study systematically evaluates the potential influence of radius of rotation on apparent tracer binding and describes methods for correction. METHODS: Monte Carlo simulation scans of a digital brain phantom with various disease states and various radii of rotation ranging from 13 to 30 cm were analyzed using 4 different methods of semi-quantification. Different volumes of interest as well as a method with partial volume correction were applied. RESULTS: For conventional 3D semi-quantification methods the decrease of measured striatal binding per cm additional radius rotation lied in the range between 2.5 and 3.1 %, whereas effects were negligible when applying recovery-corrected quantification. Effects were independent of disease state. CONCLUSION: Partial volume effects with increasing radius of rotation can lead to considerable decrease of measured binding ratios, particularly when applying dopamine transporter imaging in a research setting. Standardization of acquisition radius can avoid the effect; correction seems feasible, but the correction factors depend on the quantification approach applied.


Assuntos
Encéfalo/diagnóstico por imagem , Simulação por Computador , Método de Monte Carlo , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Encéfalo/metabolismo , Encefalopatias/diagnóstico por imagem , Encefalopatias/metabolismo , Núcleo Caudado/diagnóstico por imagem , Núcleo Caudado/metabolismo , Corpo Estriado/diagnóstico por imagem , Corpo Estriado/metabolismo , Progressão da Doença , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Humanos , Modelos Neurológicos , Imagens de Fantasmas , Putamen/diagnóstico por imagem , Putamen/metabolismo , Rotação , Fatores de Tempo
11.
J Vestib Res ; 24(5-6): 403-13, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25564083

RESUMO

BACKGROUND: Absence of peripheral vestibular input in bilateral vestibular failure (BVF) has been suggested to induce plastic reorganization in various brain regions. Among several neurotransmitters, dopamine is known to play a key role in cortico-striatal-sensorimotor processing. However, the role of dopamine in vestibular plasticity is scantly documented. OBJECTIVE: Assessment of D 2/3 formula-receptors in patients with BVF. METHODS: D 2/3 formula-receptor-PET using [18F]fallypride and MRI examinations were performed in 12 BVF-patients and 13 healthy controls. RESULTS: BVF-patients showed reduced D 2/3 formula-receptor availability (approximately 40%) in the temporo-parieto-occipital cortex bilaterally, including the multisensory vestibular cortex and visual motion-sensitive areas (MT/MST), as well as in the striatum and the right thalamus. Longer illness duration was associated with bilaterally lower D 2/3 formula-receptor availability in the middle/superior temporal gyrus (GTm/s). D 2/3 formula-receptor availability in the right GTm/s and bilateral insula decreased with severity of symptoms. BVF-patients with oscillopsia showed reduced D 2/3 formula-receptor availability in the right MT/MST and midbrain tectum. CONCLUSIONS: Reduced D 2/3 formula-receptor availability in multisensory vestibular cortical network areas and basal ganglia may indicate a receptor down-regulation due to the lack of peripheral vestibular input. The more pronounced decline in D 2/3 formula-receptor availability in the multisensory vestibular cortex in patients with prolonged illness suggests the occurrence of progressive changes in dopamine transmission.


Assuntos
Encéfalo/metabolismo , Receptores de Dopamina D2/metabolismo , Receptores de Dopamina D3/metabolismo , Doenças Vestibulares/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzamidas/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Mapeamento Encefálico , Feminino , Radioisótopos de Flúor/metabolismo , Humanos , Imageamento por Ressonância Magnética , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Cintilografia , Doenças Vestibulares/diagnóstico por imagem , Doenças Vestibulares/patologia
12.
Nucl Med Commun ; 34(10): 971-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23884235

RESUMO

OBJECTIVES: Dopamine transporter imaging with single-photon emission computed tomography (SPECT) is a valuable tool for both clinical routine and research studies. Recently, it was found that the image quality could be improved by introduction of the three-dimensional ordered subset expectation maximization (3D-OSEM) reconstruction algorithm, which provides resolution recovery. The aim of this study was to systematically evaluate the potential benefits of 3D-OSEM in comparison with 2D-OSEM under critical imaging conditions, for example, scans with a high radius of rotation. MATERIALS AND METHODS: Monte Carlo simulation scans of a digital brain phantom with various disease states and different radii of rotation ranging from 13 to 30 cm were reconstructed with both 2D-OSEM and 3D-OSEM algorithms. Specific striatal binding and putamen-to-caudate ratios were determined and compared with true values in the phantom. RESULTS: The percentage recovery of true striatal binding was similar between both reconstruction algorithms at the minimum rotational radius; however, at the maximum rotational radius, it decreased from 53 to 43% for 3D-OSEM and from 52 to 26% for 2D-OSEM. 3D-OSEM matched the true putamen-to-caudate ratios more closely than did 2D-OSEM in scans with high SPECT rotation radii. CONCLUSION: 3D-OSEM offers a promising image quality gain. It outperforms 2D-OSEM, particularly in studies with limited resolutions (such as scans acquired with a high radius of rotation) but does not improve the accuracy of the putamen-to-caudate ratios. Whether the benefits of better recovery in studies with higher radii of rotation could potentially increase the diagnostic power of dopamine transporter SPECT in patients with borderline striatal radiotracer binding, however, needs to be further examined.


Assuntos
Imageamento Tridimensional/métodos , Rotação , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tropanos , Humanos , Método de Monte Carlo , Doença de Parkinson/diagnóstico por imagem
13.
Eur J Echocardiogr ; 9(4): 494-500, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17923438

RESUMO

AIM: To evaluate the additional benefit of visual and quantitative perfusion measurements compared with conventional real-time myocardial contrast echocardiography (MCE) in the detection of CAV. METHODS AND RESULTS: Thirty patients (26 males, age 58 +/- 9.6 years) underwent dobutamine stress echocardiography (DSE) and myocardial perfusion imaging (MPI) as well as coronary angiography (CA) with intravascular ultrasound (IVUS). Ultrasound images were analysed off-line, evaluating (1) wall motion and thickening at high mechanical index ('conventional evaluation'), (2) the MCE loops stored during continuous infusion of contrast agent with regard to visual changes (stress vs. rest, 'visual grading'), and (3) the replenishment curves of the contrast agent at low mechanical index after bubble destruction ('quantitative grading'). CA/IVUS plus MPI showed ischaemia in seven and myocardial scars in nine patients. Sensitivity, specificity, NPV, PPV and accuracy for the detection of ischaemia representing functionally relevant CAV were, respectively, 0.71, 0.83, 0.90, 0.55 and 0.80 for the conventional evaluation alone, 0.71, 0.91, 0.91, 0.71 and 0.87 for additional visual grading and 0.86, 0.91, 0.95, 0.75 and 0.90 for additional quantitative grading. CONCLUSION: Real-time MCE including visual and quantitative analysis is feasible for screening patients after HTX and is highly accurate in the diagnosis of haemodynamically relevant CAV.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia , Transplante de Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Transplante Homólogo , Idoso , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA