Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Pharmacokinet Pharmacodyn ; 48(3): 439-444, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33660229

RESUMO

The quantitative description of individual observations in non-linear mixed effects models over time is complicated when the studied biomarker has a pulsatile release (e.g. insulin, growth hormone, luteinizing hormone). Unfortunately, standard non-linear mixed effects population pharmacodynamic models such as turnover and precursor response models (with or without a cosinor component) are unable to quantify these complex secretion profiles over time. In this study, the statistical power of standard statistical methodology such as 6 post-dose measurements or the area under the curve from 0 to 12 h post-dose on simulated dense concentration-time profiles of growth hormone was compared to a deconvolution-analysis-informed modelling approach in different simulated scenarios. The statistical power of the deconvolution-analysis-informed approach was determined with a Monte-Carlo Mapped Power analysis. Due to the high level of intra- and inter-individual variability in growth hormone concentrations over time, regardless of the simulated effect size, only the deconvolution-analysis informed approach reached a statistical power of more than 80% with a sample size of less than 200 subjects per cohort. Furthermore, the use of this deconvolution-analysis-informed modelling approach improved the description of the observations on an individual level and enabled the quantification of a drug effect to be used for subsequent clinical trial simulations.


Assuntos
Ritmo Circadiano/fisiologia , Modelos Biológicos , Área Sob a Curva , Variação Biológica Individual , Variação Biológica da População/fisiologia , Biomarcadores/metabolismo , Ensaios Clínicos como Assunto , Estudos de Coortes , Voluntários Saudáveis , Hormônio do Crescimento Humano/metabolismo , Humanos , Insulina/metabolismo , Hormônio Luteinizante/metabolismo , Masculino , Método de Monte Carlo
2.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345649

RESUMO

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade Aguda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA