Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Water Sci Technol ; 79(2): 334-341, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30865604

RESUMO

China has achieved significant progress on wastewater treatment and aquatic environmental protection. However, leakage (in- and exfiltration) of sewer systems is still an issue. By using the statistical data of water and wastewater in 2016 in China, and the person loads (PLs) of water and wastewater in Singapore, the leakage fractions of hydraulic flow, organic carbon (COD), nitrogen (N) and phosphorus (P) mass loading, and in-sewer COD biological removal in the sewer systems of China (except Hong Kong, Macau and Taiwan), Shanghai, Guangzhou and Beijing were reported for the first time. The fractions of hydraulic flow infiltration (13%, Shanghai and Guangzhou) and exfiltration (39%, China) were calculated. Except Beijing, whose sewer networks are under appropriate management with small leakage fractions, the exfiltration fractions of COD (including in-sewer biological COD removal) ranged from 41% (Shanghai) to 66% (China) and averaged 55%; N ranged from 18% (Shanghai) to 48% (China) and averaged 33%; and P ranged from 23% (Shanghai and Guangzhou) to 44% (China) and averaged 30%. The exfiltrated sewage, COD, N and P not only wastes resources, but also contaminates the aquatic environment (especially groundwater) and contributes to 'black and odorous water bodies'. In- and exfiltration in the sewer network leads to low influent COD concentration, C/N ratio and high inorganic solids and inert particulate COD concentrations of many municipal wastewater treatment plants (WWTPs) causing high cost for nutrient removal, poor resource recovery, additional reactor/settler volume requirement and other operational problems. Therefore, tackling sewer leakage is of primary importance to today's environment in China. Recommendations for the inspection of sewer systems and the rehabilitation of damaged sewers as well as the development of design and operation guidelines of municipal WWTPs tailored to the specific local sewage characteristics and other conditions are proposed.


Assuntos
Esgotos , Eliminação de Resíduos Líquidos/métodos , Poluição Química da Água/estatística & dados numéricos , China , Drenagem Sanitária , Odorantes , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/estatística & dados numéricos , Águas Residuárias/análise , Águas Residuárias/química , Poluição Química da Água/análise , Poluição Química da Água/economia
2.
Water Res ; 47(1): 43-8, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23121895

RESUMO

Application of fine-mesh sieves (<0.35 mm) as pretreatment for municipal biological wastewater treatment gives an opportunity to recover resources and increase sustainability of wastewater treatment processes. Sieves are traditionally used for single stage mechanical treatment (typical mesh of 0.35 mm) or in combination with an MBR (typical mesh >0.7 mm). When sieves with a mesh of 0.35 mm are used on raw sewage we observed that cellulose fibres mainly originating from toilet paper are removed efficiently from the influent with a high recovery and purity. The application of sieves as pretreatment for conventional activated sludge processes has been evaluated based on pilot plant research at three WWTPs in the Netherlands. With sieving applied to the dry weather flow only the overall energy usage of the WWTP including sludge treatment can be decreased by at least 40% with a payback time of 7 years.


Assuntos
Celulose , Conservação de Recursos Energéticos , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/instrumentação , Purificação da Água/métodos
3.
Water Sci Technol ; 65(3): 410-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22258669

RESUMO

Development, population growth and climate change have pressurized water stress in the world. Being an urbanized coastal city, Hong Kong has adopted a dual water supply system since the 1950s for seawater toilet flushing for 80% of its 7 million inhabitants. Despite its success in saving 750,000 m(3)/day of freshwater, the saline sewage (consisting of about 20-30% of seawater) appears to have sacrificed the urban water cycle in terms of wastewater reuse and recycling. Can seawater toilet flushing be applied without affecting the urban water cycle with respect to sustainable water resource management? To address this issue, we examined the entire urban water cycle and developed an innovative water resource management system by integrating freshwater, seawater and reclaimed grey water into a sustainable, low-freshwater demand, low-energy consumption, and low-cost triple water supply (TWS) system. The applicability of this novel system has been demonstrated at the Hong Kong International Airport which reduced 52% of its freshwater demand.


Assuntos
Aeroportos , Água Doce/química , Reciclagem , Água do Mar/química , Eliminação de Resíduos Líquidos/métodos , Meio Ambiente , Hong Kong , Reciclagem/economia , Reciclagem/métodos , Banheiros
4.
Water Res ; 45(13): 4008-18, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21632087

RESUMO

In groundwater treatment for drinking water production, the causes of nitrification problems and the effectiveness of process optimization in rapid sand filters are often not clear. To assess both issues, the performance of a full-scale groundwater filter with nitrification problems and another filter with complete nitrification and pretreatment by subsurface aeration was monitored over nine months. Quantitative real-time polymerase chain reaction (qPCR) targeting the amoA gene of bacteria and archaea and activity measurements of ammonia oxidation were used to regularly evaluate water and filter sand samples. Results demonstrated that subsurface aeration stimulated the growth of ammonia-oxidizing prokaryotes (AOP) in the aquifer. Cell balances, using qPCR counts of AOP for each filter, showed that the inoculated AOP numbers from the aquifer were marginal compared with AOP numbers detected in the filter. Excessive washout of AOP was not observed and did not cause the nitrification problems. Ammonia-oxidizing archaea grew in both filters, but only in low numbers compared to bacteria. The cell-specific nitrification rate in the sand and backwash water samples was high for the subsurface aerated filter, but systematically much lower for the filter with nitrification problems. From this, we conclude that incomplete nitrification was caused by nutrient limitation.


Assuntos
Archaea/metabolismo , Reação em Cadeia da Polimerase/métodos , Purificação da Água/métodos , Abastecimento de Água , Proteínas Arqueais/genética , Bactérias/metabolismo , Proteínas de Bactérias/genética
5.
Water Sci Technol ; 61(7): 1715-22, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20371929

RESUMO

The Olburgen sewage treatment plant has been upgraded to improve the effluent quality by implementing a separate and dedicated treatment for industrial (potato) wastewater and reject water. The separate industrial treatment has been realized within a beneficial public-private partnership. The separate treatment of the concentrated flows of industrial wastewater and sludge treatment effluent proved to be more cost-efficient and area and energy efficient than a combined traditional treatment process. The industrial wastewater was first treated in a UASB reactor for biogas production. The UASB reactor effluent was combined with the reject water and treated in a struvite reactor (Phospaq process) followed by a one stage granular sludge nitritation/anammox process. For the first time both reactors where demonstrated on full scale and have been operated stable over a period of 3 years. The recovered struvite has been tested as a suitable substitute for commercial fertilizers. Prolonged exposure of granular anammox biomass to nitrite levels up to 30 mg/l did not result in inhibition of the anammox bacteria in this reactor configuration. The chosen option required a 17 times smaller reactorvolume (20,000 m(3) less volume) and saves electric power by approximately 1.5 GWh per year.


Assuntos
Arquitetura de Instituições de Saúde , Resíduos Industriais , Engenharia Sanitária/economia , Engenharia Sanitária/métodos , Esgotos/química , Eliminação de Resíduos Líquidos/instrumentação , Conservação dos Recursos Naturais , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Água/química , Purificação da Água/métodos
6.
Water Sci Technol ; 56(9): 117-25, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18025739

RESUMO

The combined SHARON-Anammox process is a promising technique for nitrogen removal from wastewater streams with high ammonium concentrations. It is typically applied to sludge digestion reject water, in order to relieve the activated sludge tanks, to which this stream is typically recycled. This contribution assesses the impact of the applied control strategy in the SHARON-reactor, both on the effluent quality of the subsequent Anammox reactor as well as on the plant-wide level by means of an operating cost index. Moreover, it is investigated to which extent the usefulness of a certain control strategy depends on the reactor design (volume). A simulation study is carried out using the plant-wide Benchmark Simulation Model no. 2 (BSM2), extended with the SHARON and Anammox processes. The results reveal a discrepancy between optimizing the reject water treatment performance and minimizing plant-wide operating costs.


Assuntos
Reatores Biológicos , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Anaerobiose , Modelos Teóricos , Esgotos/análise , Eliminação de Resíduos Líquidos/instrumentação , Purificação da Água/economia , Purificação da Água/instrumentação , Purificação da Água/métodos
7.
Water Sci Technol ; 54(8): 93-100, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17163017

RESUMO

In wastewater treatment plants (WWTPs) equipped with sludge digestion and dewatering systems, the reject water originating from these facilities contributes significantly to the nitrogen load of the activated sludge tanks, to which it is typically recycled. In this paper, the impact of reject water streams on the performance of a WWTP is assessed in a simulation study, using the Benchmark Simulation Model no. 2 (BSM2), that includes the processes describing sludge treatment and in this way allows for plant-wide evaluation. Comparison of performance of a WWTP without reject water with a WWTP where reject water is recycled to the primary clarifier, i.e. the BSM2 plant, shows that the ammonium load of the influent to the primary clarifier is 28% higher in the case of reject water recycling. This results in violation of the effluent total nitrogen limit. In order to relieve the main wastewater treatment plant, reject water treatment with a combined SHARON-Anammox process seems a promising option. The simulation results indicate that significant improvements of the effluent quality of the main wastewater treatment plant can be realized. An economic evaluation of the different scenarios is performed using an Operating Cost Index (OCI).


Assuntos
Esgotos , Eliminação de Resíduos Líquidos/instrumentação , Purificação da Água/instrumentação , Algoritmos , Redução de Custos , Modelos Teóricos , Nitrogênio/metabolismo , Compostos de Amônio Quaternário/metabolismo , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Purificação da Água/economia , Purificação da Água/métodos
8.
Water Sci Technol ; 53(4-5): 45-54, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16722054

RESUMO

The combined SHARON-Anammox process for treating wastewater streams with high ammonia load is the focus of this paper. In particular, partial nitritation in the SHARON reactor should be performed to such an extent that a nitrite:ammonium ratio is generated which is optimal for full conversion in an Anammox process. In the simulation studies performed in this contribution, the nitrite:ammonium ratio produced in a SHARON process with fixed volume, as well as its effect on the subsequent Anammox process, is examined for realistic influent conditions and considering both direct and indirect pH effects on the SHARON process. Several possible operating modes for the SHARON reactor, differing in control strategies for O2, pH and the produced nitrite:ammonium ratio and based on regulating the air flow rate and/or acid/base addition, are systematically evaluated. The results are quantified through an operating cost index. Best results are obtained by means of cascade feedback control of the SHARON effluent nitrite:ammonium ratio through setting an O2 set-point that is tracked by adjusting the air flow rate, combined with single loop pH control through acid/base addition.


Assuntos
Reatores Biológicos , Nitritos/análise , Oxigênio/análise , Compostos de Amônio Quaternário/análise , Eliminação de Resíduos Líquidos/métodos , Movimentos do Ar , Bactérias/metabolismo , Custos e Análise de Custo , Concentração de Íons de Hidrogênio , Nitritos/metabolismo , Sistemas On-Line , Compostos de Amônio Quaternário/metabolismo , Eliminação de Resíduos Líquidos/economia
9.
Water Sci Technol ; 53(3): 227-35, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16605036

RESUMO

An integrated anaerobic-aerobic treatment system of sulphate-laden wastewater was proposed here to achieve low sludge production, low energy consumption and effective sulphide control. Before integrating the whole system, the feasibility of autotrophic denitrification utilising dissolved sulphide produced during anaerobic treatment of sulphate rich wastewater was studied here. An upflow anaerobic sludge blanket reactor was operated to treat sulphate-rich synthetic wastewater (TOC=100 mg/L and sulphate=500 mg/L) and its effluent with dissolved sulphide and external nitrate solution were fed into an anoxic biofilter. The anaerobic reactor was able to remove 77-85% of TOC at HRT of 3 h and produce 70-90 mg S/L sulphide in dissolved form for the subsequent denitrification. The performance of anoxic reactor was stable, and the anoxic reactor could remove 30 mg N/L nitrate at HRT of 2 h through autotrophic denitrification. Furthermore, sulphur balance for the anoxic filter showed that more than 90% of the removed sulphide was actually oxidised into sulphate, thereby there was no accumulation of sulphur particles in the filter bed. The net sludge productions were approximately 0.15 to 0.18 g VSS/g COD in the anaerobic reactor and 0.22 to 0.31 g VSS/g NO3- -N in the anoxic reactor. The findings in this study will be helpful in developing the integrated treatment system to achieve low-cost excess sludge minimisation.


Assuntos
Nitrogênio/metabolismo , Esgotos/química , Sulfatos/análise , Sulfatos/metabolismo , Eliminação de Resíduos Líquidos/economia , Eliminação de Resíduos Líquidos/métodos , Filtração , Hong Kong , Nitratos/química , Oxirredução , Oxigênio/química , Solubilidade
10.
Water Sci Technol ; 52(4): 107-15, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16235752

RESUMO

The combined SHARON-Anammox process for treating wastewater streams with high ammonia concentration is discussed. Partial nitritation in the SHARON reactor should be performed to such an extent that an Anammox-optimal nitrite:ammonium ratio is generated. The SHARON process is typically applied to sludge digestion rejection water in order to relieve the ammonium load recycled to the main plant. A simulation study for realistic influent conditions on a SHARON reactor with a fixed volume and operated with constant air flow rate reveals that the actual nitrite:ammonium ratio might deviate significantly from the ideal ratio and might endanger operation of the subsequent Anammox reactor. It is further examined how the nitrite:ammonium ratio might be optimized. A cascade pH control strategy and a cascade O2 control strategy are tested. Simulation results are presented and the performance of the different strategies is assessed and quantified in an economic way by means of an operating cost index. Best results are obtained by means of cascade feedback control of the SHARON effluent nitrite:ammonium ratio through setting an O2-set-point that is tracked by adjusting the air flow rate.


Assuntos
Reatores Biológicos/economia , Purificação da Água/economia , Biomassa , Redução de Custos , Concentração de Íons de Hidrogênio , Nitritos/metabolismo , Oxigênio/metabolismo , Compostos de Amônio Quaternário/metabolismo
11.
Water Sci Technol ; 49(11-12): 177-85, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15303739

RESUMO

The mathematical modeling of spatial biofilm formation that provides the capability to predict biofilm structure from first principles has been in development for the past six years. However, a direct and quantitative link between model predictions and the experimentally observed structure formation still remains to be established. This work assesses the capability of a state-of-the-art technique for three-dimensional (3D) modeling of biofilm structure, individual based modeling (IbM), to quantitatively describe the early development of a multispecies denitrifying biofilm. Model evaluation was carried out by comparison of predicted structure with that observed from two experimental datasets using confocal laser scanning microscopy (CLSM) monitoring of biofilm development in laboratory flowcells. Experimental conditions provided biofilm growth without substrate limitation, which was confirmed from substrate profiles computed by the model. 3D structures were compared quantitatively using a set of morphological parameters including the biovolume, filled-space profiles, substratum coverage, average thickness and normalized roughness. In spite of the different morphologies detectable in the two independent short-term experiments analyzed here, the model was capable of accurate fitting data from both experiments. Prediction of structure formation was precise, as expressed by the set of morphology parameters used.


Assuntos
Bactérias/crescimento & desenvolvimento , Biofilmes/crescimento & desenvolvimento , Imageamento Tridimensional , Modelos Teóricos , Biomassa , Previsões , Microscopia Confocal , Eliminação de Resíduos Líquidos
12.
Water Sci Technol ; 49(11-12): 1-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15303716

RESUMO

Laboratory experiments have shown that it is possible to cultivate aerobic granular sludge in sequencing batch reactors. In order to direct future research needs and the critical points for successful implementation at large scale, a full detailed design of a potential application was made. The design was based on the laboratory results, and two variants of a full-scale sewage treatment plant based on Granular sludge Sequencing Batch Reactors (GSBRs) were evaluated. As a reference a conventional treatment plant based on activated sludge technology was designed for the same case. Based on total annual costs both GSBR variants proved to be more attractive than the reference alternative (7-17% lower costs). From a sensitivity analysis it appeared that the GSBR technology was less sensitive to the land price and more sensitive to a rain weather flow (RWF). This means that the GSBR technology becomes more attractive at lower permissible RWF/DWF ratios and higher land prices. The footprint of the GSBR variants was only 25% compared to the reference. However, the GSBR with primary treatment only cannot meet the present effluent standards for municipal wastewater in The Netherlands, mainly because of a too high suspended solids concentration in the effluent. A growing number of sewage treatment plants in the Netherlands are going to be faced with more stringent effluent standards. In general, activated sludge plants will have to be extended with a post treatment step (e.g. sand filtration) or be transformed into Membrane Bioreactors. In this case a GSBR variant with primary treatment as well as post treatment can be an attractive alternative.


Assuntos
Reatores Biológicos , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos , Bactérias Aeróbias , Custos e Análise de Custo , Países Baixos , Tamanho da Partícula , Eliminação de Resíduos Líquidos/economia , Poluentes da Água/isolamento & purificação
13.
Water Sci Technol ; 46(1-2): 313-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12216642

RESUMO

Electron acceptor utilisation potential of filtered primary sludge under anoxic conditions was experimentally investigated. Major kinetic and stoichiometric parameters were assessed by means of model evaluation of nitrate profile obtained in batch reactors. ASM1, modified for endogenous decay, and ASM3 were used for model simulation. Both models provided consistent interpretation of experimental data. ASM1 yielded mu(H) and Y(HD) values of 6.1 d(-1) and 0.64 g cell COD(g COD)(-1) respectively for heterotrophic anoxic growth. The corresponding storage mechanism associated with ASM3 could be characterised by a k(STO) of 13 g COD (g COD d)(-1) and a Y(STO) of 0.78 g COD(g COD)(-1). The high k(STO) value suggests re-evaluation of the concept of readily biodegradable substrate as defined in ASM3 and tested in the study.


Assuntos
Reatores Biológicos , Modelos Teóricos , Nitratos/metabolismo , Esgotos/química , Biodegradação Ambiental , Oxigênio , Esgotos/microbiologia , Eliminação de Resíduos Líquidos
14.
Water Sci Technol ; 46(1-2): 345-52, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12216648

RESUMO

A new procedure has been defined for the respirometric assessment of bacterial storage yield as defined in the Activated Sludge Model No.3. The procedure was used to determine the storage yield, Y(STO), associated with acetate, glucose and domestic sewage, together with mixtures of acetate/glucose and acetate/domestic sewage at different initial F/M ratios. Y(STO) was calculated as 0.78 gCOD(gCOD)(-1) for acetate, 0.87 gCOD(gCOD)(-1) for glucose and 0.96 gCOD(gCOD)(-1) for domestic sewage. The Y(STO) of substrate mixtures was found to reflect the characteristics of the dominant fraction in the mixture.


Assuntos
Acetatos/metabolismo , Glucose/metabolismo , Esgotos/microbiologia , Reatores Biológicos , Oxigênio/metabolismo , Eliminação de Resíduos Líquidos
15.
Water Res ; 36(3): 702-12, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11831218

RESUMO

Aerobic granular sludge was cultivated in an intensely mixed sequencing batch airlift reactor (SBAR). A COD loading of 2.5 kg Acetate-COD/(m3 d) was applied. Granules developed in the reactor within one week after inoculation with suspended activated sludge from a conventional wastewater treatment plant. Selection of the dense granules from the biomass mixture occurs because of the differences in settling velocities between granules (fast settling biomass), and filaments and flocs (slow settling biomass). At 'steady state' the granules had an average diameter of 2.5 mm, a biomass density of 60g VSS/I of granules, and a settling rate of > 10 m/h. The biomass consisted of both heterotrophic and nitrifying bacteria. The reactor was operated over a long period during which the granular sludge proved to remain stable. The performance of the intermittently fed SBAR was compared to that of the continuously fed biofilm airlift suspension reactor (BASR). The most importance difference was that the density of the granules in the SBAR was much higher than the density of the biofilms in the BASR. It is discussed that this could be due to the fact that the SBAR is intermittently fed, while the BASR is continuously fed.


Assuntos
Bactérias Aeróbias/fisiologia , Biomassa , Eliminação de Resíduos Líquidos/métodos , Movimentos do Ar , Biofilmes , Reatores Biológicos , Tamanho da Partícula , Dinâmica Populacional , Esgotos , Movimentos da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA