Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-37813596

RESUMO

BACKGROUND AND OBJECTIVES: Optical coherence tomography angiography (OCTA) is a noninvasive high-resolution imaging technique for assessing the retinal vasculature and is increasingly used in various ophthalmologic, neuro-ophthalmologic, and neurologic diseases. To date, there are no validated consensus criteria for quality control (QC) of OCTA. Our study aimed to develop criteria for OCTA quality assessment. METHODS: To establish criteria through (1) extensive literature review on OCTA artifacts and image quality to generate standardized and easy-to-apply OCTA QC criteria, (2) application of OCTA QC criteria to evaluate interrater agreement, (3) identification of reasons for interrater disagreement, revision of OCTA QC criteria, development of OCTA QC scoring guide and training set, and (4) validation of QC criteria in an international, interdisciplinary multicenter study. RESULTS: We identified 7 major aspects that affect OCTA quality: (O) obvious problems, (S) signal strength, (C) centration, (A) algorithm failure, (R) retinal pathology, (M) motion artifacts, and (P) projection artifacts. Seven independent raters applied the OSCAR-MP criteria to a set of 40 OCTA scans from people with MS, Sjogren syndrome, and uveitis and healthy individuals. The interrater kappa was substantial (κ 0.67). Projection artifacts were the main reason for interrater disagreement. Because artifacts can affect only parts of OCTA images, we agreed that prior definition of a specific region of interest (ROI) is crucial for subsequent OCTA quality assessment. To enhance artifact recognition and interrater agreement on reduced image quality, we designed a scoring guide and OCTA training set. Using these educational tools, 23 raters from 14 different centers reached an almost perfect agreement (κ 0.92) for the rejection of poor-quality OCTA images using the OSCAR-MP criteria. DISCUSSION: We propose a 3-step approach for standardized quality control: (1) To define a specific ROI, (2) to assess the occurrence of OCTA artifacts according to the OSCAR-MP criteria, and (3) to evaluate OCTA quality based on the occurrence of different artifacts within the ROI. OSCAR-MP OCTA QC criteria achieved high interrater agreement in an international multicenter study and is a promising QC protocol for application in the context of future clinical trials and studies.


Assuntos
Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Consenso , Angiofluoresceinografia/métodos , Retina/diagnóstico por imagem
2.
Pharmacoeconomics ; 40(3): 323-339, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921350

RESUMO

BACKGROUND: Patients with highly active relapsing-remitting multiple sclerosis inadequately responding to first-line therapies (interferon-based therapies, glatiramer acetate, dimethyl fumarate, and teriflunomide, known collectively as "BRACETD") often switch to natalizumab or fingolimod. OBJECTIVE: The aim was to estimate the comparative effectiveness of switching to natalizumab or fingolimod or within BRACETD using real-world data and to evaluate the cost-effectiveness of switching to natalizumab versus fingolimod using a United Kingdom (UK) third-party payer perspective. METHODS: Real-world data were obtained from MSBase for patients relapsing on BRACETD in the year before switching to natalizumab or fingolimod or within BRACETD. Three-way-multinomial-propensity-score-matched cohorts were identified, and comparisons between treatment groups were conducted for annualised relapse rate (ARR) and 6-month-confirmed disability worsening (CDW6M) and improvement (CDI6M). Results were applied in a cost-effectiveness model over a lifetime horizon using a published Markov structure with health states based on the Expanded Disability Status Scale. Other model parameters were obtained from the UK MS Survey 2015, published literature, and publicly available UK sources. RESULTS: The MSBase analysis found a significant reduction in ARR (rate ratio [RR] = 0.64; 95% confidence interval [CI] 0.57-0.72; p < 0.001) and an increase in CDI6M (hazard ratio [HR] = 1.67; 95% CI 1.30-2.15; p < 0.001) for switching to natalizumab compared with BRACETD. For switching to fingolimod, the reduction in ARR (RR = 0.91; 95% CI 0.81-1.03; p = 0.133) and increase in CDI6M (HR = 1.30; 95% CI 0.99-1.72; p = 0.058) compared with BRACETD were not significant. Switching to natalizumab was associated with a significant reduction in ARR (RR = 0.70; 95% CI 0.62-0.79; p < 0.001) and an increase in CDI6M (HR = 1.28; 95% CI 1.01-1.62; p = 0.040) compared to switching to fingolimod. No evidence of difference in CDW6M was found between treatment groups. Natalizumab dominated (higher quality-adjusted life-years [QALYs] and lower costs) fingolimod in the base-case cost-effectiveness analysis (0.453 higher QALYs and £20,843 lower costs per patient). Results were consistent across sensitivity analyses. CONCLUSIONS: This novel real-world analysis suggests a clinical benefit for therapy escalation to natalizumab versus fingolimod based on comparative effectiveness results, translating to higher QALYs and lower costs for UK patients inadequately responding to BRACETD.


Assuntos
Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Análise Custo-Benefício , Cloridrato de Fingolimode/uso terapêutico , Humanos , Imunossupressores , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Natalizumab/uso terapêutico
3.
Brain Sci ; 11(9)2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34573267

RESUMO

There is increasing interest in the development and deployment of digital solutions to improve patient care and facilitate monitoring in medical practice, e.g., by remote observation of disease symptoms in the patients' home environment. Digital health solutions today range from non-regulated wellness applications and research-grade exploratory instruments to regulated software as a medical device (SaMD). This paper discusses the considerations and complexities in developing innovative, effective, and validated SaMD for multiple sclerosis (MS). The development of SaMD requires a formalised approach (design control), inclusive of technical verification and analytical validation to ensure reliability. SaMD must be clinically evaluated, characterised for benefit and risk, and must conform to regulatory requirements associated with device classification. Cybersecurity and data privacy are also critical. Careful consideration of patient and provider needs throughout the design and testing process help developers overcome challenges of adoption in medical practice. Here, we explore the development pathway for SaMD in MS, leveraging experiences from the development of Floodlight™ MS, a continually evolving bundled solution of SaMD for remote functional assessment of MS. The development process will be charted while reflecting on common challenges in the digital space, with a view to providing insights for future developers.

4.
Clin Neurophysiol ; 126(8): 1617-23, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25481337

RESUMO

OBJECTIVE: To evaluate multifocal visual evoked potentials (mfVEP) changes in optic neuritis (ON) and fellow eyes during first year after the attack. METHODS: Eighty-seven patients and twenty-five controls were examined. Patients were classified as multiple sclerosis (MS) group, high risk (HR) or low risk (LR) groups for conversion to MS. mfVEP recordings and retinal nerve fiber layer (RNFL) thickness were analyzed. RESULTS: Recovery of amplitude and shortening of latency was fastest within the first 3months. The largest amplitude reduction and longest latency delay of the ON eye were recorded in the MS group. This was accompanied by deterioration of both parameters in fellow eyes (p<0.03). mfVEP remained stable in fellow eyes of the LR group. Inter-eye asymmetry showed similar amount of amplitude reduction and latency delay in all three groups. RNFL thickness strongly correlated with mfVEP amplitude as early as 3 months after ON (R(2)=0.6, p=0.001). CONCLUSION: mfVEP amplitude is an early predictor of post-ON axonal loss. The apparent more severe involvement of ON eyes in the MS subgroup may be due to subclinical inflammation along the visual pathway. SIGNIFICANCE: Severity of amplitude reduction and latency delay after episode of ON is not MS-related. Retro-chiasmal demyelination is a possible factor contributing to amplitude and latency differences between MS and non-MS patients.


Assuntos
Potenciais Evocados Visuais/fisiologia , Neurite Óptica/diagnóstico , Vias Visuais/fisiopatologia , Percepção Visual/fisiologia , Adulto , Axônios/fisiologia , Doenças Desmielinizantes/fisiopatologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurite Óptica/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA