Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
ESC Heart Fail ; 11(3): 1802-1807, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38351672

RESUMO

AIMS: Achieving optimized guideline-directed medical therapy (GDMT) is recommended prior to transcatheter mitral valve edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). We aimed to propose and validate an easy-to-use score for assessing the quality of GDMT in patients with heart failure with reduced ejection fraction (HFrEF) undergoing M-TEER. METHODS AND RESULTS: Among the 1641 EuroSMR patients enrolled in the EuroSMR Registry who underwent M-TEER, a total of 1072 patients [median age 74, interquartile range (IQR) 67-79 years, 29% female] had complete data on GDMT and a left ventricular ejection fraction ≤ 40% and were included in the current study. We proposed a GDMT score that considers the dosage levels of three medication classes (angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors, beta-blockers, and mineralocorticoid receptor antagonists), with a maximum score of 12 points indicating optimal GDMT. The primary outcome was all-cause mortality. The median GDMT score was 4 points (IQR 3-6). All three domains of the scoring system were associated with all-cause mortality (P < 0.05 for all). The overall GDMT score was associated with all-cause mortality (hazard ratio 0.90, 95% confidence interval 0.86-0.95 for each 1-point increase in the GDMT score). This association remained significant after adjusting for renal function and co-morbidities. CONCLUSIONS: This study demonstrates the utility of a simple GDMT scoring system for assessing the adequacy of GDMT in HFrEF patients with relevant SMR undergoing M-TEER. The GDMT score has potential applications in guiding the design of future clinical trials and aiding clinical decision-making processes.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Volume Sistólico , Humanos , Feminino , Masculino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Volume Sistólico/fisiologia , Valva Mitral/cirurgia , Sistema de Registros , Cateterismo Cardíaco/métodos , Função Ventricular Esquerda/fisiologia , Seguimentos , Guias de Prática Clínica como Assunto , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
2.
Eur J Heart Fail ; 26(1): 18-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38131233

RESUMO

Right-sided heart failure and tricuspid regurgitation are common and strongly associated with poor quality of life and an increased risk of heart failure hospitalizations and death. While medical therapy for right-sided heart failure is limited, treatment options for tricuspid regurgitation include surgery and, based on recent developments, several transcatheter interventions. However, the patients who might benefit from tricuspid valve interventions are yet unknown, as is the ideal time for these treatments given the paucity of clinical evidence. In this context, it is crucial to elucidate aetiology and pathophysiological mechanisms leading to right-sided heart failure and tricuspid regurgitation in order to recognize when tricuspid regurgitation is a mere bystander and when it can cause or contribute to heart failure progression. Notably, early identification of right heart failure and tricuspid regurgitation may be crucial and optimal management requires knowledge about the different mechanisms and causes, clinical course and presentation, as well as possible treatment options. The aim of this clinical consensus statement is to summarize current knowledge about epidemiology, pathophysiology and treatment of tricuspid regurgitation in right-sided heart failure providing practical suggestions for patient identification and management.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Qualidade de Vida , Valva Tricúspide/cirurgia , Resultado do Tratamento
3.
Int J Cardiol ; 136(1): 64-71, 2009 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-18657334

RESUMO

BACKGROUND: Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter. METHODS: We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from systolic LVOT areas. These results were compared to area values obtained by M-mode LVOT-diameters (area=pi(*)(d/2)(2)). In addition, the calculated aortic valve orifices were compared to invasive measurements or direct planimetry in the transthoracic or transesophageal examination. RESULTS: Two independent observers found a reduction in LVOT area during systole (p<0.001). Often a more ellipsoid-like shaped LVOT resulted at end-systole which was shown by a reduction (p<0.001) of the LVOT longitudinal to oblique axis ratio. 3D-TTE determination of aortic valve orifice areas (mean difference: -0.04+/-0.09 cm(2)) showed a lesser deviation from the invasively or planimetrically measured areas than conventionally calculated LVOT areas (mean difference: -0.1+/-0.1 cm(2)) using the continuity equation (p<0.001). CONCLUSIONS: The tested transthoracic 3D-echocardiography technique offers non-invasive measurement of the LVOT and aortic valve area based on the continuity equation during systole and thus improves accuracy and, additionally, agreement of aortic valvular area determination with invasive and direct measurements.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/normas , Ecocardiografia/normas , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
4.
Echocardiography ; 22(1): 15-23, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15660682

RESUMO

AIM: To demonstrate the feasibility of transthoracic three-dimensional real-time echocardiography (3D-TTE) supplemental to routine assessments of the tricuspid valve and to analyze interrater agreement. METHODS: Twenty healthy subjects and 74 patients with right ventricular failure were examined with conventional 2D and additionally 3D-TTE (SONOS 7500, Philips, Netherlands). The 3D exams were performed and recorded by one of two raters. The recordings were evaluated offline and independently by both raters for visualization of morphological and functional features of the tricuspid valve according to a subjective 3-point scale. Statistical analyses were performed for interrater agreement and for comparison of imaging quality between the two study groups. In addition, we present an illustrative case report. RESULTS: Visualization of the spatial relationship between the tricuspid valve and vicinal structures, of the commissures, the orifice, and entirety of valve depiction were better in the ventricular failure group as compared to the control group. Annular dimensions were equally assessable in both groups, leaflet thickness and mobility were not significantly different. Interrater agreement on assessability was slight for leaflet thickness, fair for leaflet mobility and orifice area, and good for the remaining features. The 3D-TTE exam including offline evaluation took 6.5 minutes on average and maximally 14 minutes. CONCLUSION: 3D-TTE of the tricuspid valve can be performed in addition to routine 2D echocardiography within a reasonable time and with high assessability of important features in patients with right ventricular failure. Interrater agreement was fair to good overall. Thus, its feasibility may encourage prospective studies on its potential for more detailed noninvasive diagnosis and preoperative planning.


Assuntos
Ecocardiografia Tridimensional/métodos , Valva Tricúspide/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Variações Dependentes do Observador , Fatores de Tempo , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA