Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 651
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 21(11): 2103-2109, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38823667

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation carries the risk of silent cerebral event (SCE) and silent cerebral lesion (SCL). Although "silent," these may have long-term clinical implications and are challenging to study as postprocedural magnetic resonance imaging (MRI) is not standard of care. OBJECTIVE: The neurological assessment subgroup (NAS) of ADVENT compared cerebral effects of pulsed field ablation (PFA) with standard-of-care thermal ablation. METHODS: The NAS included consecutive randomized PFA and thermal ablation patients who received postprocedural brain MRI 12-48 hours after ablation. Patients with apparent SCE or SCL findings underwent a modified Rankin scale assessment. MRI images were subsequently reviewed by a blinded brain imaging core laboratory. RESULTS: In total, 77 patients with paroxysmal AF were enrolled at 6 centers; 71 had analyzable scans (34 PFA; 37 thermal ablation). Through individual center review, 6 PFA and 4 thermal scans were identified as SCE/SCL positive, of which 3 PFA and 0 thermal SCE/SCL findings were confirmed by a blinded core laboratory. MRI findings revealed 1 patient with 2- to 4-mm SCEs, 1 patient with a 3-mm SCE, and 1 patient with 2 SCLs (5.5 mm and 11 mm). All modified Rankin scale and National Institutes of Health Stroke Scale scores were 0 before discharge and at 90-day follow-up. There were only 2 neurological safety events (1 transient ischemic attack [PFA] and 1 stroke [thermal ablation]) in the ADVENT study, neither of which was part of the NAS. CONCLUSION: The ADVENT trial provides the first prospective, randomized data on the cerebral impact of PFA and thermal ablation of AF. Incidence of SCE/SCL after ablation in the NAS was low.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Idoso , Resultado do Tratamento , Seguimentos , Estudos Prospectivos
2.
J Cardiovasc Electrophysiol ; 35(8): 1570-1578, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38837730

RESUMO

BACKGROUND: Same day discharge (SDD) following atrial fibrillation (AF) ablation procedure has emerged as routine practice, and primarily driven by operator discretion. However, the impacts of SDD on clinical outcomes, healthcare system costs, and patient reported outcomes (PROs) have not been systematically studied. METHODS: We retrospectively analyzed patients undergoing routine AF ablation procedures with SDD versus overnight observation (NSDD). After propensity adjustment we compared postprocedure adverse events (AEs), healthcare system costs, and changes in PROs. RESULTS: We identified 310 cases, with 159 undergoing SDD and 151 staying at least one midnight in the hospital (NSDD). Compared with NSDD, SDD patients were similar age (mean 64 vs. 66, p = 0.3), sex (26% female vs. 27%, p = 0.8), and with lower mean CHADS2-VA2Sc scores (2.0 vs. 2.7; p < 0.011). The primary outcome of AEs was noninferior in SDD versus NSDD patients (odds ratio 0.45, 95% confidence interval 0.21-0.99; noninferiority margin of 10%). There were also no differences in overall cost to the healthcare system between SDD and NSDD (p = 0.11). PROs numerically favored SDD (p = NS for all scores). CONCLUSIONS: Physician selection for SDD appears at least as safe as NSDD with respect to clinical outcomes and SDD is not significantly less costly to the health system. There is a trend towards more favorable, general PROs among SDD patients. Routine SDD should be strongly considered for patients undergoing routine AF ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Alta do Paciente , Medidas de Resultados Relatados pelo Paciente , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/economia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Ablação por Cateter/economia , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Alta do Paciente/economia , Custos Hospitalares , Fatores de Risco , Análise Custo-Benefício , Tempo de Internação/economia , Procedimentos Cirúrgicos Ambulatórios/economia , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos
3.
JTCVS Tech ; 25: 81-93, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899102

RESUMO

Objectives: To assess feasibility, safety, and early efficacy of robotic-enhanced epicardial ablation (RE-EA) as first stage of a hybrid approach to patients with persistent (PsAF) and long-standing atrial fibrillation (LSAF). Methods: Single-center, retrospective analysis of patients with documented PsAF and LSAF who underwent RE-EA followed by catheter-guided endocardial ablation. Postoperatively, patients were monitored for major adverse events and underwent rhythm follow-up at 3 and 12 months. Results: Between January 2021 and June 2023, we performed RE-EA in 64 patients (73.5% male, CHA2DS2-VASc 2.7 ± 1.6, BMI 34.1 ± 6.3 kg/m2). Mean AF preoperative duration and left atrial volume index were, respectively, 85 months and 47.5 mL/m2. Through the robotic approach, the intended lesion set was completed in all patients without cardiopulmonary bypass support, conversion to thoracotomy/sternotomy, blood transfusions, or perioperative mortality. The average LOS was 1.7 days, with only 1 patient requiring intensive care unit admission and >65% of patients discharged within 24 hours. At follow-up, 2 (3.1%) patients experienced new left pleural effusion or hemidiaphragm paralysis requiring treatment. There were no readmissions related to AF, stroke, thromboembolic events, or deaths. The mean interval between the epicardial and endocardial stages of the procedure was 5.9 months. Rhythm follow-up showed AF resolution in 73.4% and 71.9% of patients at 3 and 12 months, respectively. Conclusions: RE-EA is a feasible and safe, first-stage approach for the treatment of patients with PsAF and LSAF. It improves exposure of the intended targets, favors short hospital stay, and facilitates return to activity with satisfactory AF treatment in the short term.

4.
J Med Econ ; 27(1): 826-835, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38889094

RESUMO

BACKGROUND AND AIMS: Cardiac ablation is a well-established method for treating atrial fibrillation (AF). Pulsed field ablation (PFA) is a non-thermal therapeutic alternative to radiofrequency ablation (RFA) and cryoballoon ablation (CRYO). PFA uses high-voltage electric pulses to target cells. The present analysis aims to quantify the costs, outcomes, and resources associated with these three ablation strategies for paroxysmal AF. METHODS: Real-world clinical data were prospectively collected during index hospitalization by three European medical centers (Belgium, Germany, the Netherlands) specialized in cardiac ablation. These data included procedure times (pre-procedural, skin-to-skin and post-procedural), resource use, and staff burden. Data regarding complications associated with each of the three treatment options and redo procedures were extracted from the literature. Costs were collected from hospital economic formularies and published cost databases. A cost-consequence model from the hospital perspective was built to estimate the impact of the three treatment options in terms of effectiveness and costs. RESULTS: Across the three centers, N = 91 patients were included over a period of 12 months. A significant difference was seen in pre-procedural time (mean ± SD, PFA: 13.6 ± 3.7 min, CRYO: 18.8 ± 6.6 min, RFA: 20.4 ± 6.4 min; p < .001). Procedural time (skin-to-skin) was also different across alternatives (PFA: 50.9 ± 22.4 min, CRYO: 74.5 ± 24.5 min, RFA: 140.2 ± 82.4 min; p < .0001). The model reported an overall cost of €216,535 per 100 patients treated with PFA, €301,510 per 100 patients treated with CRYO and €346,594 per 100 patients treated with RFA. Overall, the cumulative savings associated with PFA (excluding kit costs) were €850 and €1,301 per patient compared to CRYO and RFA, respectively. CONCLUSION: PFA demonstrated shorter procedure time compared to CRYO and RFA. Model estimates indicate that these time savings result in cost savings for hospitals and reduce outlay on redo procedures. Clinical practice in individual hospitals varies and may impact the ability to transfer the results of this analysis to other settings.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Análise Custo-Benefício , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/economia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/economia , Ablação por Cateter/métodos , Idoso , Duração da Cirurgia , Estudos Prospectivos , Europa (Continente) , Criocirurgia/economia , Criocirurgia/métodos , Complicações Pós-Operatórias/economia , Recursos em Saúde/estatística & dados numéricos , Recursos em Saúde/economia
5.
Heart Rhythm ; 21(9): 1562-1569, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38763376

RESUMO

BACKGROUND: Long-term clinical outcomes of catheter ablation (CA) compared to thoracoscopic surgical ablation (SA) to treat patients with long-standing persistent atrial fibrillation (LSPAF) are not known. OBJECTIVE: The purpose of this study was to compare the long-term (36-month) clinical efficacy, quality of life, and cost-effectiveness of SA and CA in LSPAF. METHODS: Participants were followed up for 3 years using implantable loop recorders and questionnaires to assess the change in quality of life. Intention-to-treat analyses were used to report the findings. RESULTS: Of the 115 patients with LSPAF treated, 104 (90.4%) completed 36-month follow-up [CA: n = 57 (95%); SA: n = 47 (85%)]. After a single procedure without antiarrhythmic drugs, 7 patients (12%) in the CA arm and 5 (11%) in the SA arm [hazard ratio 1.22; 95% confidence interval (CI) 0.81-1.83; P = .41] were free from atrial fibrillation/tachycardia (AF/AT) ≥30 seconds at 36 months. Thirty-three patients (58%) in the CA arm and 26 (55%) in the SA arm (hazard ratio 1.04; 95% CI 0.57-1.88; P = .91) had their AF/AT burden reduced by ≥75%. The overall impact on health-related quality of life was similar, with mean quality-adjusted life year estimates of 2.45 (95% CI 2.31-2.59) for CA and 2.32 (95% CI 2.13-2.52) for SA. Estimated costs were higher for SA (mean £24,682; 95% CI £21,746-£27,618) than for CA (mean £18,002; 95% CI £15,422-£20,581). CONCLUSION: In symptomatic LSPAF, CA and SA were equally effective at achieving arrhythmia outcomes (freedom from AF/AT ≥30 seconds and ≥75% burden reduction) after a single procedure without antiarrhythmic drugs. However, SA is significantly more costly than CA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Análise Custo-Benefício , Qualidade de Vida , Toracoscopia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/economia , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Toracoscopia/métodos , Toracoscopia/economia , Seguimentos , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia Ambulatorial/economia , Idoso , Fatores de Tempo
6.
Heart Rhythm ; 21(9): 1537-1544, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-38763378

RESUMO

BACKGROUND: With the exponential growth of catheter ablation for atrial fibrillation (AF), there is increasing interest in associated health care costs. Pulsed field ablation (PFA) using a single-shot pentaspline multielectrode catheter has been shown to be safe and effective for AF ablation, but its cost efficiency compared to conventional thermal ablation modalities (cryoballoon [CB] or radiofrequency [RF]) has not been evaluated. OBJECTIVE: The purpose of this study was to compare cost, efficiency, effectiveness, and safety between PFA, CB, and RF for AF ablation. METHODS: We studied 707 consecutive patients (PFA: 208 [46.0%]; CB: 325 [29.4%]; RF: 174 [24.6%]) undergoing first-time AF ablation. Individual procedural costs were calculated, including equipment, laboratory use, and hospital stay, and compared between ablation modalities, as were effectiveness and safety. RESULTS: Skin-to-skin times and catheter laboratory times were significantly shorter with PFA (68 and 102 minutes, respectively) than with CB (91 and 122 minutes) and RF (89 and 123 minutes) (P < .001). General anesthesia use differed across modalities (PFA 100%; CB 10.2%; RF 61.5%) (P < .001). Major complications occurred in 1% of cases, with no significant differences between modalities. Shorter procedural times resulted in lower staffing and laboratory costs with PFA, but these savings were offset by substantially higher equipment costs, resulting in higher overall median costs with PFA (£10,010) than with CB (£8106) and RF (£8949) (P < .001). CONCLUSION: In this contemporary real-world study of the 3 major AF ablation modalities used concurrently, PFA had shorter skin-to-skin and catheter laboratory times than did CB and RF, with similarly low rates of complications. However, PFA procedures were considerably more expensive, largely because of higher equipment cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Fibrilação Atrial/economia , Humanos , Masculino , Feminino , Ablação por Cateter/métodos , Ablação por Cateter/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Análise Custo-Benefício , Estudos Retrospectivos , Idoso , Criocirurgia/métodos , Criocirurgia/economia , Seguimentos
7.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38818846

RESUMO

AIMS: We aimed to assess the acute and midterm efficacy of premature ventricular contraction (PVC) ablation guided by multielectrode and point-by-point (PbP) mapping. METHODS AND RESULTS: This is a retrospective, international multicentre study of consecutive patients referred for PVC ablation in 10 hospital centres from January 2017 to December 2021. Based on the mapping approach, two cohorts were identified: the 'Multipolar group', where a dedicated high-density mapping catheter was employed, and the 'PbP group', where mapping was performed with the ablation catheter. Procedural endpoints, safety, and acute (procedural) and midterm efficacies were assessed. Of the 698 patients included in this study, 592 received activation mapping [46% males, median age of 55 (41-65) years]-248 patients in the Multipolar group and 344 patients in the PbP group. A higher number of activation points [432 (217-843) vs. 95 (42-185), P < 0.001], reduced mapping time (40 ± 38 vs. 61 ± 50 min, P < 0.001), and shorter procedure time (124 ± 60 vs. 143 ± 63 min, P < 0.001) were reported in the Multipolar group. Both groups had high acute success rates (84.7% with Multipolar mapping vs. 81.3% with PbP mapping, P = 0.63), as well as midterm efficacy (83.4% vs. 77.4%, P = 0.08), with no significant differences in the risk of adverse events (6.0% vs. 3.5%, P = 0.24). However, for left-sided PVC ablation specifically, there was a higher midterm efficacy in the Multipolar group (80.7% vs. 69.5%, P = 0.04), with multipolar mapping being an independent predictor of success [adjusted OR = 2.231 (95% CI, 1.476-5.108), P = 0.02]. CONCLUSION: The acute and midterm efficacies of PVC ablation are high with both multipolar and PbP mapping, although the former allows for quicker procedures and may potentially improve the outcomes of left-sided PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/diagnóstico , Masculino , Pessoa de Meia-Idade , Feminino , Ablação por Cateter/métodos , Estudos Retrospectivos , Idoso , Adulto , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas
8.
Lasers Med Sci ; 39(1): 121, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722564

RESUMO

To develop and validate a 3D simulation model to calculate laser ablation (LA) zone size and estimate the volume of treated tissue for thyroid applications, a model was developed, taking into account dynamic optical and thermal properties of tissue change. For validation, ten Yorkshire swines were equally divided into two cohorts and underwent thyroid LA at 3 W/1,400 J and 3 W/1,800 J respectively with a 1064-nm multi-source laser (Echolaser X4 with Orblaze™ technology; ElEn SpA, Calenzano, Italy). The dataset was analyzed employing key statistical measures such as mean and standard deviation (SD). Model simulation data were compared with animal gross histology. Experimental data for longitudinal length, width (transverse length), ablation volume and sphericity were 11.0 mm, 10.0 mm, 0.6 mL and 0.91, respectively at 1,400 J and 14.6 mm, 12.4 mm, 1.12 mL and 0.83, respectively at 1,800 J. Gross histology data showed excellent reproducibility of the ablation zone among same laser settings; for both 1,400 J and 1,800 J, the SD of the in vivo parameters was ≤ 0.7 mm, except for width at 1,800 J, for which the SD was 1.1 mm. Simulated data for longitudinal length, width, ablation volume and sphericity were 11.6 mm, 10.0 mm, 0.62 mL and 0.88, respectively at 1,400 J and 14.2 mm, 12.0 mm, 1.06 mL and 0.84, respectively at 1,800 J. Experimental data for ablation volume, sphericity coefficient, and longitudinal and transverse lengths of thermal damaged area showed good agreement with the simulation data. Simulation datasets were successfully incorporated into proprietary planning software (Echolaser Smart Interface, Elesta SpA, Calenzano, Italy) to provide guidance for LA of papillary thyroid microcarcinomas. Our mathematical model showed good predictability of coagulative necrosis when compared with data from in vivo animal experiments.


Assuntos
Terapia a Laser , Glândula Tireoide , Animais , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Glândula Tireoide/cirurgia , Glândula Tireoide/patologia , Suínos , Simulação por Computador , Modelos Teóricos , Reprodutibilidade dos Testes
9.
Circ Arrhythm Electrophysiol ; 17(7): e012854, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38758741

RESUMO

BACKGROUND: Unlike conventional microsecond pulsed electrical fields that primarily target the cell membranes, nanosecond pulses are thought to primarily electroporate intracellular organelles. We conducted a comprehensive preclinical assessment of catheter-based endocardial nanosecond pulsed field ablation in swine. METHODS: A novel endocardial nanosecond pulsed field ablation system was evaluated in a total of 25 swine. Using either a low-dose (5-second duration) or high-dose (15-second duration) strategy, thoracic veins and discrete atrial and ventricular sites were ablated. Predetermined survival periods were <1 (n=1), ≈2 (n=7), ≈7 (n=6), 14 (n=2), or ≈28 (n=9) days, and venous isolation was assessed before euthanasia. Safety assessments included evaluation of esophageal effects, phrenic nerve function, and changes in venous caliber. All tissues were subject to careful gross pathological and histopathologic examination. RESULTS: All (100%) veins (13 low-dose, 34 high-dose) were acutely isolated, and all reassessed veins (6 low-dose, 15 high-dose) were durably isolated. All examined vein lesions (10 low-dose, 22 high-dose) were transmural. Vein diameters (n=15) were not significantly changed. Of the animals assessed for phrenic palsy (n=9), 3 (33%) demonstrated only transient palsy. There were no differences between dosing strategies. Thirteen mitral isthmus lesions were analyzed, and all 13 (100%) were transmural (depth, 6.4±0.4 mm). Ventricular lesions were 14.7±4.5 mm wide and 7.1±1.3 mm deep, with high-dose lesions deeper than low-dose (7.9±1.2 versus 6.2±0.8 mm; P=0.007). The esophagus revealed nontransmural adventitial surface lesions in 5 of 5 (100%) animals euthanized early (2 days) post-ablation. In the 10 animals euthanized later (14-28 days), all animals demonstrated significant esophageal healing-8 with complete resolution, and 2 with only trace fibrosis. CONCLUSIONS: A novel, endocardial nanosecond pulsed field ablation system provides acute and durable venous isolation and linear lesions. Transient phrenic injury and nontransmural esophageal lesions can occur with worst-case assessments suggesting limits to pulsed field ablation tissue selectivity and the need for dedicated assessments during clinical studies.


Assuntos
Estudos de Viabilidade , Nervo Frênico , Animais , Suínos , Fatores de Tempo , Miocárdio/patologia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Veias/fisiopatologia , Modelos Animais , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/patologia , Esôfago , Átrios do Coração/fisiopatologia , Átrios do Coração/patologia
10.
J Clin Med ; 13(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38792377

RESUMO

Background: Atrial fibrillation (AF) is the most common cardiac arrhythmia, and its prevalence is expected to increase further due to the aging population, increasing prevalence of risk factors, improving detection methods, and broadening of catheter ablation indications. Along with limited healthcare resources and bed availability, these reasons led to the development of a same-day discharge (SDD) protocol. The aim of this study was to evaluate the health and economic impact of a routine adoption of same-day discharge after cryoballoon AF ablation. Methods: Consecutive patients with symptomatic and drug-refractory AF scheduled for first-time AF ablation were screened, and if deemed suitable, the SDD protocol was proposed and, if accepted, enrolled in the protocol. Results: A total of 324 patients were screened, and 118 were considered eligible for the SDD pathway. Fifty-two patients accepted the SDD pathway and were included in this study. The analysis showed that the variation in resource consumption associated with cryoablation in SDD is equal to EUR 739.85/patient. The analysis showed that the main cost driver for ordinary hospitalization was represented by the hospital stay, which was calculated to be 36% of the total cost. In total, there was a cost reduction of EUR 38.472 thanks to optimized AF patient management from the standard recovery setting to SDD. Conclusions: SDD after cryoballoon ablation of AF is feasible in selected patients with a standardized protocol.

11.
Radiologie (Heidelb) ; 64(6): 503-514, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38780657

RESUMO

The aim of this article is to provide an overview on the most frequently applied image-guided, percutaneous, local ablative techniques for treatment of primary and secondary liver tumors. The technical procedures of microwave ablation (MWA) and radiofrequency ablation (RFA) are presented. The pre-interventional diagnostics, indications and feasibility are also discussed, taking the current national guidelines into consideration. Finally, treatment outcomes and recommendations on post-interventional imaging following local tumor ablation are presented.


Assuntos
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos , Técnicas de Ablação/métodos , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento
12.
Heart Rhythm ; 21(11): 2187-2194, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38734228

RESUMO

BACKGROUND: Epicardial ablation complications are more frequent in patients with preexisting pericardial adhesions. As opposed to the dry puncture technique, the coronary vein exit and carbon dioxide (CO2) insufflation (EpiCO2) technique allows diagnosing pericardial adhesions before subxiphoid puncture. OBJECTIVE: This study aimed to evaluate the efficacy of the EpiCO2 technique in diagnosing pericardial adhesions prior to subxiphoid puncture. METHODS: Following coronary vein exit, contrast was injected in the pericardial space, and adhesions classified using our novel Brighton Adhesion Classification (BAC) into BAC-0 (no adhesions), BAC-1 (dispersed adhesions), and BAC-2 (dense adhesions extending to the entire assessed area). CO2 insufflation allowed subclassification of BAC-1 adhesions into BAC-1a (not preventing epicardial access or restricting catheter movement) and BAC-1b (either preventing epicardial access or significantly limiting catheter movement). RESULTS: Intentional coronary vein exit (right atrial appendage exit in 1 case) was achieved in all 235 consecutive epicardial ablation procedures undertaken at our center. A diagnosis of BAC-0 was made in 219 cases (93.2%), BAC-1a in 9 cases (3.8%), BAC-1b in 2 cases (0.9%), and BAC-2 in 5 cases (2.1%). This led to not attempting subxiphoid puncture in 6 cases (2.6%) and abandoning epicardial mapping because of limited catheter movement in 1 case (0.4%). Access-related complications occurred in 7 cases (3%) only in the BAC-0 group. CONCLUSION: The EpiCO2 technique allows assessment of the presence of pericardial adhesions prior to attempting subxiphoid puncture for epicardial access, which may lead to a reduction in the procedural complications within this subset of patients.


Assuntos
Ablação por Cateter , Pericárdio , Humanos , Aderências Teciduais , Pericárdio/diagnóstico por imagem , Feminino , Masculino , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Insuflação/métodos , Insuflação/efeitos adversos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Dióxido de Carbono , Idoso , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Estudos Retrospectivos
13.
J Cardiovasc Electrophysiol ; 35(8): 1561-1569, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38818534

RESUMO

INTRODUCTION: Esophageal safety following radiofrequency (RF) left atrial (LA) linear ablation has not been established. To determine the esophageal safety profile of LA linear RF lesions, we performed systematic esophagogastroduodenoscopy in all patients with intraesophageal temperature rise (ITR) ≥ 38.5°C. METHODS AND RESULTS: Between December 2021 and July 2023, a total of 200 consecutive patients with atrial tachyarrhythmia (ATA) underwent linear ablation with posterior dome (roof or floor) or posterior mitral isthmus line transection. Patients with ITR ≥ 38.5°C were scheduled for esophageal endoscopy ~3 weeks after ablation. Patient and ATA characteristics, procedural parameters, endoscopy findings and ablation lesion data were collected and analyzed. One hundred thirty-three out of 200 (67%) patients showed ITR ≥ 38.5°C during LA linear ablation. ITR (with maximal temperature of 45.7°C) was more frequently observed during floor line ablation (82% of cases). ITR was less observed during roof line ablation (34%) and posterior mitral isthmus ablation (4%). Endoscopy, performed in 115 patients after 24 ± 10 days, showed esophageal ulceration in four patients (two patients Kansas City classification [KCC] 2a and two patients KCC 2b). No patient showed esophageal perforation or fistula. CONCLUSION: Temperature rise during LA linear ablation is frequent and ulceration risk exists, particularly when floor line is performed. Safety measures are needed to avoid potential severe complications like esophageal perforation and fistula.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Úlcera , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Úlcera/diagnóstico por imagem , Úlcera/etiologia , Úlcera/diagnóstico , Resultado do Tratamento , Idoso , Medição de Risco , Fatores de Risco , Ablação por Cateter/efeitos adversos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Doenças do Esôfago/etiologia , Doenças do Esôfago/diagnóstico , Fatores de Tempo , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Endoscopia do Sistema Digestório/efeitos adversos , Estudos Retrospectivos , Esôfago/lesões
15.
Am J Otolaryngol ; 45(4): 104361, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38729015

RESUMO

OBJECTIVES: This study aims to analyze utilization and reimbursement trends in lingual and hyoid surgery for obstructive sleep apnea (OSA). METHODS: Annual retrospective data on lingual and hyoid OSA surgeries was obtained from the 2000-2021 Medicare Part B National Summary Datafiles. Current Procedural Terminology (CPT) codes utilized included 21,685 (hyoid myotomy and suspension [HMS]), 41,512 (tongue base suspension [TBS]), 41,530 (radiofrequency ablation of the tongue [RFT]) and 42,870 (lingual tonsillectomy [LT]). RESULTS: The number of lingual and hyoid OSA surgeries rose 2777 % from 121 in 2000 to 3481 in 2015, before falling 82.9 % to 594 in 2021. Accordingly, Medicare payments rose 17,899 % from an inflation-adjusted $46,958 in 2000 to $8.45 million in 2015, before falling drastically to $341,011 in 2021. As the number of HMSs (2000: 91; 2015: 84; 2021: 165), TBS (2009: 48; 2015: 31; 2021: 16), and LTs (2000: 121; 2015: 261; 2021: 234) only experienced modest changes in utilization, this change was largely driven by RFT (2009: 340; 2015: 3105; 2021: 179). Average Medicare payments for RFT rose from $1110 in 2009 to $2994 in 2015, before falling drastically to $737 in 2021. CONCLUSION: Lingual and hyoid surgery for OSA has overall fallen in utilization among the Medicare population from 2000 to 2021. However, there was a brief spike in usage, peaking in 2015, driven by the adoption (and then quick dismissal) of RFT. The rise and fall in RFT use coincide with the rise and fall in reimbursement.


Assuntos
Osso Hioide , Apneia Obstrutiva do Sono , Língua , Apneia Obstrutiva do Sono/cirurgia , Apneia Obstrutiva do Sono/economia , Humanos , Estados Unidos , Estudos Retrospectivos , Osso Hioide/cirurgia , Língua/cirurgia , Medicare/economia , Reembolso de Seguro de Saúde/tendências , Reembolso de Seguro de Saúde/economia
16.
Artigo em Inglês | MEDLINE | ID: mdl-38775921

RESUMO

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

17.
Circ J ; 88(7): 1068-1077, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38811199

RESUMO

BACKGROUND: It has not been fully elucidated which patients with persistent atrial fibrillation (PerAF) should undergo substrate ablation plus pulmonary vein isolation (PVI). This study aimed to identify PerAF patients who required substrate ablation using intraprocedural assessment of the baseline rhythm and the origin of atrial fibrillation (AF) triggers. METHODS AND RESULTS: This was a post hoc subanalysis using extended data of the EARNEST-PVI trial, a prospective multicenter randomized trial comparing PVI-alone and PVI-plus (i.e., PVI with added catheter ablation) arms. We divided 492 patients into 4 groups according to baseline rhythm and the location of AF triggers before PVI: Group A (n=22), sinus rhythm with pulmonary vein (PV)-specific AF triggers (defined as reproducible AF initiation from PVs only); Group B (n=211), AF with PV-specific AF triggers; Group C (n=94), sinus rhythm with no PV-specific AF trigger; Group D (n=165), AF with no PV-specific AF trigger. Among the 4 groups, only in Group D (AF at baseline and no PV-specific AF triggers) was arrhythmia-free survival significantly lower in the PVI-alone than PVI-plus arm (P=0.032; hazard ratio 1.68; 95% confidence interval 1.04-2.70). CONCLUSIONS: Patients with sinus rhythm or PV-specific AF triggers did not receive any benefit from substrate ablation, whereas patients with AF and no PV-specific AF trigger benefited from substrate ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Estudos Prospectivos , Seleção de Pacientes , Resultado do Tratamento , Recidiva , Frequência Cardíaca
18.
Heart Lung ; 67: 46-52, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38657400

RESUMO

BACKGROUND: Improving quality of life is vital for patients with atrial fibrillation (AF) after radiofrequency ablation. Quality of life can be affected not only by personal mastery but also by health promoting behavior as previously studied. However, it remains unclear whether health promoting behavior mediates the relationship between personal mastery and quality of life. OBJECTIVES: To explore whether health promoting behavior mediates the relationship between personal mastery and quality of life in patients with AF after radiofrequency ablation. METHODS: A cross-sectional design and convenience sampling were conducted at a tertiary hospital in China. Self-reported questionnaires were used to assess personal mastery, health promoting behavior and quality of life. SPSS and AMOS software were used for statistical analysis. RESULTS: A total of 202 patients with AF after radiofrequency ablation were enrolled (mean age 58.28 ± 12.70 years). The scores for personal mastery and quality of life were 22.52 ± 2.53 points and 62.58 ± 8.59 points, respectively, indicating a limited level. The health promoting behavior exhibited a moderate level, with scores averaging 103.82 ± 8.47 points. There was a positive correlation between the three variables (all P < 0.05). Health promoting behavior played a partial mediating role in the relationship between personal mastery and quality of life in patients with AF after radiofrequency ablation, accounting for 44.79 % of the total effect. CONCLUSIONS: In order to improve quality of life and prognosis, it is necessary to consider enhancing personal mastery and increasing patient compliance with health promoting behavior, which are important ways to improve their quality of life.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Qualidade de Vida , Humanos , Fibrilação Atrial/psicologia , Fibrilação Atrial/cirurgia , Qualidade de Vida/psicologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Ablação por Cateter/métodos , Ablação por Cateter/psicologia , Inquéritos e Questionários , China/epidemiologia , Comportamentos Relacionados com a Saúde , Ablação por Radiofrequência/métodos , Ablação por Radiofrequência/psicologia , Idoso , Promoção da Saúde/métodos , Autorrelato
19.
J Cardiovasc Dev Dis ; 11(4)2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38667728

RESUMO

Purpose: Atrioesophageal fistula is one of the most feared complications of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF) as it is associated with high mortality. Determining the esophagus location during RFCA might reduce the risk of esophageal injury. The present study aims to evaluate the feasibility of using intracardiac echocardiography integrated into a 3-dimensional electroanatomical mapping system (ICE/3D EAM) for the assessment of esophageal position and shifts in response to ablation. Methods: We prospectively enrolled 20 patients that underwent RFCA of AF under conscious analgosedation. The virtual anatomy of the left atrium, the pulmonary vein (PV) ostia, and the esophagus was created with ICE/3D EAM. The esophageal positions were obtained at the beginning of the procedure and then after left and right PV isolation (PVI). Esophageal shifts were measured offline after the procedure using the tools available in the 3D EAM system. Results: Most esophagi moved away from the ablated PV ostia. After the left PVI, the median of the shifts was 2.8 mm (IQR 1.0-6.3). In 25% of patients, the esophagus shifted by >5.0 mm (max. 13.4 mm). After right PVI, the median of shifts was 2.0 mm (IQR 0.7-4.9). In 10% of patients, the esophageal shift was >5.0 mm (max. 7.8 mm). Conclusions: ICE/3D EAM enables the intraprocedural visualization of baseline esophageal position and its shifts after PVI. The shifts are variable, but they tend to be small and directed away from the ablation site. Repeated intraprocedural visualization of the esophagus may be needed to reduce the risk of esophageal injury.

20.
J Interv Card Electrophysiol ; 67(7): 1563-1570, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38632135

RESUMO

BACKGROUND: Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS: Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS: The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION: CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Meios de Contraste , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Feminino , Masculino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Pessoa de Meia-Idade , Criocirurgia/métodos , Resultado do Tratamento , Estudos Prospectivos , Idoso , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA