Resultados 1 - 7 de 7
Filtrar
1.
J Chromatogr A ; 1347: 96-103, 2014 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-24819017

RESUMO

An ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP-MS) method was developed for the redox speciation analysis of iron (Fe) based on in-column complexation of Fe(2+) and Fe(3+) by dipicolinic acid (DPA). The effects of column type, mobile phase composition and molecular ion interference were studied in the method optimization. The carryover of the target species in the IC-ICP-MS method was uniquely and effectively evaluated using isotopically enriched analogues of the analytes ((54)Fe(2+) and (57)Fe(3+)). Standard solutions of the enriched standards were injected into the system following analysis of a sample, and the ratios of the isotopes of iron in the enriched standards were calculated based on the chromatographic peak areas. The concentrations of the analytes carried over from the sample to the enriched standards were determined using the quantitative relationship in isotope dilution mass spectrometry (IDMS). In contrast to the routine way of evaluating carryover effect by injecting a blank solution after sample analysis, the use of isotopically enriched standards identified significant analyte carryover in the present method. Extensive experiments were carried out to systematically identify the source of the carryover and to eliminate the problem; the separation column was found to be the exclusive source. More than 95% of the analyte carryover was eliminated by reducing the length of the column. The detection limit of the IC-ICP-MS method (MDL) for the iron species was 2ngg(-1). The method was used to determine Fe(2+) and Fe(3+) in synthetic aqueous standard solutions and a beverage sample.


Assuntos
Ferro/análise , Cátions , Cromatografia/métodos , Complexos de Coordenação/química , Ferro/química , Isótopos , Limite de Detecção , Espectrometria de Massas/métodos , Oxirredução , Ácidos Picolínicos/química
2.
Phys Chem Chem Phys ; 13(22): 10771-80, 2011 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-21552622

RESUMO

We present high field DEER (double electron-electron resonance) distance measurements using Gd(3+) (S = 7/2) spin labels for probing peptides' conformations in solution. The motivation for using Gd(3+) spin labels as an alternative for the standard nitroxide spin labels is the sensitivity improvement they offer because of their very intense EPR signal at high magnetic fields. Gd(3+) was coordinated by dipicolinic acid derivative (4MMDPA) tags that were covalently attached to two cysteine thiol groups. Cysteines were introduced in positions 15 and 27 of the peptide melittin and then two types of spin labeled melittins were prepared, one labeled with two nitroxide spin labels and the other with two 4MMDPA-Gd(3+) labels. Both types were subjected to W-band (95 GHz, 3.5 T) DEER measurements. For the Gd(3+) labeled peptide we explored the effect of the solution molar ratio of Gd(3+) and the labeled peptide, the temperature, and the maximum dipolar evolution time T on the DEER modulation depth. We found that the optimization of the [Gd(3+)]/[Tag] ratio is crucial because excess Gd(3+) masked the DEER effect and too little Gd(3+) resulted in the formation of Gd(3+)-tag(2) complexes, generating peptide dimers. In addition, we observed that the DEER modulation depth is sensitive to spectral diffusion processes even at Gd(3+) concentrations as low as 0.2 mM and therefore experimental conditions should be chosen to minimize it as it decreases the DEER effect. Finally, the distance between the two Gd(3+) ions, 3.4 nm, was found to be longer by 1.2 nm than the distance between the two nitroxides. The origin and implications of this difference are discussed.


Assuntos
Complexos de Coordenação/química , Gadolínio/química , Peptídeos/química , Ácidos Picolínicos/química , Espectroscopia de Ressonância de Spin Eletrônica , Meliteno/química , Método de Monte Carlo , Marcadores de Spin
3.
J Org Chem ; 75(23): 8112-6, 2010 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-21069988

RESUMO

The F(-), Cl(-), and Br(-) binding selectivity of bis(p-nitroanilide)s of dipicolinic and isophthalic acids was studied by using competitive electrospray mass spectrometry and UV-Visible spectroscopy. Both hosts prefer binding Cl(-) over either F(-) or Br(-). Host deprotonation was observed to some extent in all experiments in which the host was exposed to halide ions. When F(-) was present, host deprotonation was often the major process, whereas little deprotonation was observed by Cl(-) or Br(-), which preferred complexation. A solution of either host changed color when mixed with a F(-), H(2)PO(4)(-), di- or triphenylacetate solution.


Assuntos
Hidrocarbonetos Halogenados/química , Íons/química , Ácidos Ftálicos/química , Ácidos Picolínicos/química , Espectrometria de Massas , Estrutura Molecular , Fenilacetatos/química , Prótons , Espectrofotometria Ultravioleta
4.
Rapid Commun Mass Spectrom ; 23(15): 2264-72, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19551845

RESUMO

Application of matrix-assisted laser-desorption/ionization mass spectrometry (MALDI MS) to analysis and characterization of phosphopeptides in peptide mixtures may have a limitation, because of the lower ionizing efficiency of phosphopeptides than nonphosphorylated peptides in MALDI MS. In this work, a binary matrix that consists of two conventional matrices of 3-hydroxypicolinic acid (3-HPA) and alpha-cyano-4-hydroxycinnamic acid (CCA) was tested for phosphopeptide analysis. 3-HPA and CCA were found to be hot matrices, and 3-HPA not as good as CCA and 2,5-dihydroxybenzoic acid (DHB) for peptide analysis. However, the presence of 3-HPA in the CCA solution with a volume ratio of 1:1 could significantly enhance ion signals for phosphopeptides in both positive-ion and negative-ion detection modes compared with the use of pure CCA or DHB, the most common phosphopeptide matrices. Higher signal intensities of phosphopeptides could be obtained with lower laser power using the binary matrix. Neutral loss of the phosphate group (-80 Da) and phosphoric acid (-98 Da) from the phosphorylated-residue-containing peptide ions with the binary matrix was decreased compared with CCA alone. In addition, since the crystal shape prepared with the binary matrix was more homogeneous than that prepared with DHB, searching for 'sweet' spots can be avoided. The sensitivity to detect singly or doubly phosphorylated peptides in peptide mixtures was higher than that obtained with pure CCA and as good as that obtained using DHB. We also used the binary matrix to detect the in-solution tryptic digest of the crude casein extracted from commercially available low fat milk sample, and found six phosphopeptides to match the digestion products of casein, based on mass-to-charge values and LIFT TOF-TOF spectra.


Assuntos
Caseínas/análise , Ácidos Cumáricos/química , Fosfopeptídeos/análise , Ácidos Picolínicos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Aminoácidos , Animais , Caseínas/isolamento & purificação , Caseínas/metabolismo , Bovinos , Cristalização , Gentisatos/química , Leite/química , Dados de Sequência Molecular , Fosfopeptídeos/isolamento & purificação , Fosfopeptídeos/metabolismo , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/economia , Tripsina/metabolismo
5.
J Chromatogr A ; 1200(2): 114-21, 2008 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-18561939

RESUMO

A highly sensitive quantification method of aldosterone by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) was investigated in a positive mode using recently developed picolinyl derivatization. Aldosterone was smoothly and quantitatively converted to the ethyl ether-picolinyl derivative by treatment with HCl-ethanol followed by the esterification with picolinic acid in the presence of 2-methyl-6-nitrobenzoic anhydride and 4-dimethylaminopyridine. The positive ion-ESI mass spectrum of the ethyl ether-picolinyl derivative was characterized by an appearance of protonated molecule ([M+H](+)) as a base peak. The ethyl ether-picolinyl derivatization gave a successful result in a separation of aldosterone from corticosterone, dehydrocorticosterone and cortexolone, and also provided an approximately 10-fold higher ESI response in the positive-LC-ESI-MS/MS (selected reaction monitoring; SRM) when compared to that of underivatized molecule (negative mode). The limit of quantification of aldosterone by SRM using ethyl ether-picolinyl derivatization (m/z 494-->m/z 448) was 1 pg/0.2 ml serum with accuracy and precision of 92.6% and 5.6%, respectively.


Assuntos
Corticosteroides/química , Aldosterona/química , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Corticosteroides/sangue , Aldosterona/sangue , Etanol/química , Humanos , Ácido Clorídrico/química , Estrutura Molecular , Ácidos Picolínicos/química , Reprodutibilidade dos Testes
6.
J Chromatogr A ; 1173(1-2): 120-8, 2007 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-17964584

RESUMO

Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC-electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [M+H](+) as base peaks. The picolinoyl derivatives provided 5-10 times higher ESI response in the LC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC-ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC-ESI-MS-SRM.


Assuntos
Corticosteroides/análise , Cromatografia Líquida de Alta Pressão/métodos , Ácidos Picolínicos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Corticosteroides/química , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes , Saliva/química
7.
Steroids ; 72(11-12): 819-27, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17716700

RESUMO

A highly sensitive and specific quantification method of estrone and estradiol in human serum was described based upon the use of picolinoyl derivatization and liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) in a positive mode. Estrogens were treated with picolinoyl chloride hydrochloride or picolinic acid and 2-methyl-6-nitrobenzoic anhydride followed by a solid-phase extraction with ODS cartridge. Picolinoyl derivatization proceeded quantitatively even in a microscale, and the picolinoyl esters provided simple positive ESI-mass spectra showing [M+H](+) as base peaks for these estrogens. The picolinoyl derivatives of these estrogens showed 100-fold higher detection response compared to underivatized intact molecules by LC-ESI-MS (selected reaction monitoring). Using this derivatization, estrogens spiked in the charcoal treated human serum samples were analyzed with limit of quantification (LOQ), intra-day accuracy and precision of 1.0pg/ml, 96.0% and 9.9% for estrone, and 0.5pg/ml, 84.4% and 12.8% for estradiol, respectively. Estrone and estradiol added to the crude serum samples were recovered with comparable LOQ and accuracy obtained for the charcoal treated serum samples as well.


Assuntos
Estradiol/sangue , Estrona/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Estradiol/química , Estradiol/isolamento & purificação , Estrona/química , Estrona/isolamento & purificação , Feminino , Humanos , Ácidos Picolínicos/química , Solventes/química