Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 895
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Folia Med (Plovdiv) ; 66(1): 73-79, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38426468

RESUMO

INTRODUCTION: Schönlein-Henoch disease is a small vessel vasculitis resulting from IgA-mediated inflammation. It is the most common acute systemic vasculitis in childhood, mainly affecting the skin, gastrointestinal tract, joints, and kidneys. Although the prognosis of Schönlein-Henoch is generally good, gastrointestinal tract involvement is a potential complication, presenting as massive gastrointestinal bleeding, bowel infarction, perforation, as well as intussusception and peritonitis.


Assuntos
Vasculite por IgA , Humanos , Vasculite por IgA/complicações , Vasculite por IgA/diagnóstico , Pele , Rim , Abdome
2.
Br J Surg ; 111(3)2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38525931

RESUMO

OBJECTIVE: This study investigated if hybrid oesophagectomy with minimally invasive gastric mobilization and thoracotomy enabled faster recovery than open surgery. METHODS: In eight UK centres, this pragmatic RCT recruited patients for oesophagectomy to treat localized cancer. Participants were randomly allocated to hybrid or open surgery, stratified by centre and receipt of neoadjuvant treatment. Large dressings aimed to mask patients to their allocation for six days post-surgery. The authors present the intention-to-treat analysis of outcome measures from the first 3 months post-randomization, including the primary outcome, the patient-reported physical function scale of the EORTC QLQ-C30, and cost-effectiveness. Current Controlled Trials registration: ISRCTN 59036820 (feasibility study), 10386621 (definitive study). FINDINGS: There was no evidence of a difference between hybrid (n = 267) and open (n = 266) surgery in average physical function over 3 months post-randomization: difference in means 2.1, 95% c.i. -2.0 to 6.2, P = 0.3. Complication rates were similar; for example, 88 (34%) participants in the open and 82 (32%) participants in the hybrid surgery groups experienced a pulmonary infection within 30 days. There was no evidence that hybrid surgery was more cost-effective than open surgery at 3 months. CONCLUSIONS: Patient-reported physical function in the 3 months post-randomization provided no evidence of a difference in recovery time between hybrid and open surgery, or a difference in cost-effectiveness. Both approaches to surgery were completed safely, with a similar risk of key complications, suggesting that surgeons who have a preference for one of the two approaches need not change their practice.


Assuntos
Neoplasias Esofágicas , Humanos , Abdome/cirurgia , Análise Custo-Benefício , Neoplasias Esofágicas/cirurgia , Laparoscopia , Toracotomia
3.
Med Eng Phys ; 124: 104093, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38418023

RESUMO

This study aimed to verify the reliability and validity of abdominal expansion and respiratory function measurements. Forty healthy adult males underwent lung capacity, effort lung capacity, respiratory muscle strength, cough strength, diaphragm ultrasound, and abdominal expansion measurements. Abdominal expansion was measured using a device developed to accurately evaluate abdominal movements and calculate maximum abdominal expansion on the ventral side (AE-max: the difference between maximal abdominal contraction at the same time as maximal-effort expiration and maximal abdominal expansion at the same time as maximal-effort inspiration). Intra- and inter-rater reliabilities of the AE-max measurements were examined, the paired t-test was used for assessing the ratios of the expansion and contraction displacement components in AE-max, and regression analysis was used to obtain equations for predicting maximum inspiratory pressure (MIP) based on AE-max. Both intra- and inter-rater reliabilities were high. Criterion-related validity showed that AE-max was associated with all respiratory function parameters, especially MIP, and a high percentage of expansion displacement. Regression analysis showed that AE-max was significantly associated with MIP. Based on its association with MIP, the large proportion of expansion displacement in AE-max, and the results of the multiple regression analysis, we conclude that AE-max is a helpful measure for estimating MIP.


Assuntos
Diafragma , Respiração , Masculino , Humanos , Reprodutibilidade dos Testes , Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Abdome , Músculos Respiratórios/fisiologia
4.
Sci Rep ; 14(1): 4190, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378769

RESUMO

We investigated the effectiveness of simulation-based education in Focused Assessment with Sonography for Trauma (FAST) to increase the number of Emergency Medical Technicians (EMTs) capable of performing ultrasound examinations in vehicles under the guidance of a physician. Twenty-eight paramedics watched a 14-min video on the features of the ultrasound system, its use, and the scanning method for each part of the body. Each participant performed four FAST examinations using a portable ultrasound device, and the task performance was rated using the Task Specific Checklist (TSC) and Global Rating Scale (GRS). The time required for visualizing each examination site and each FAST was assessed. The mean time required for the first and fourth FAST was 144.6 ± 52.4 s and 90.5 ± 31.0 s, respectively. The time required for each test significantly decreased with repeated testing (p < 0.001). The time to complete FAST was significantly shortened for the pericardial cavity (33.4 ± 23.1/15.3 ± 10.6 s, p < 0.01), right thoracic cavity (25.2 ± 11.8/12.1 ± 8.3 s, p < 0.01), Morrison fossa (19.1 ± 10.8/10.8 ± 6.3 s, p < 0.05), and left thoracic cavity (19.0 ± 8.3/15.6 ± 8.3 s, p < 0.05). TSC and GRS scores were elevated, and all EMTs could obtain valid images. The combination of a brief video lecture and hands-on training significantly reduced the time required for FAST performance. Moreover, repeated practice enabled the EMTs to efficiently obtain accurate and clinically useful images.


Assuntos
Auxiliares de Emergência , Avaliação Sonográfica Focada no Trauma , Humanos , Paramédico , Ultrassonografia , Abdome , Competência Clínica
5.
Eur J Surg Oncol ; 50(2): 107931, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38181533

RESUMO

BACKGROUND: Hyperthermic intraperitoneal chemotherapy (HIPEC) associated with CC0 excision is performed using either an open (OPEN_HIPEC) or closed abdominal technique (CLOSED_HIPEC). However, little data is available on the costs of this treatment, as there is no code for HIPEC in the French Classification of Medical Acts. Oncological outcomes and the mean cost of hospitalization were compared. METHODS: Between 2017 and 2021, 144 patients with peritoneal carcinomatosis (all etiologies) were included (OPEN_HIPEC, n = 70; CLOSED_HIPEC, n = 74) in this retrospective two-center study. Morbi-mortality, overall survival (OS), recurrence-free-survival (RFS) and mean cost of hospitalization were compared. RESULTS: The median OS and RFS were 71.3 months [63-71.5] and 26.8 months [20-35.3] respectively, and were similar for both techniques; and after stratification by histology. Multivariate analysis adjusted on PCI score of OS identified mitomycin as a protective factor (HR = 0.31 [0.10-0.90], p = 0.032) and ASA score>2 (HR = 2.32 [1.32- 4.06], p = 0.003) and number of resection (HR = 1.21 [1.06-1.39], p = 0.006) as a risk factors of RFS. Complication rates at day 30 were similar between OPEN and CLOSED_HIPEC, 31 (44.3 %) vs 42 (56.8 %); p = 0.135. OPEN_HIPEC had more severe complications (11 (35.5 %) vs 6 (14.3 %); p = 0.034). The mean cost of hospitalization was estimated as €15,627 for OPEN_HIPEC and €14,211 for CLOSED_HIPEC for a mean length-of-stay of 12.7 and 16.7 days respectively. The mean amount received by the hospital per hospitalization was estimated at €16,399 and €15,536 respectively. CONCLUSIONS: OS and RFS were similar for open and closed HIPEC. Severe complications at day 30 were more frequent in OPEN_HIPEC group. The amount received by hospital for both HIPEC techniques is sufficient.


Assuntos
Hipertermia Induzida , Intervenção Coronária Percutânea , Humanos , Quimioterapia Intraperitoneal Hipertérmica , Terapia Combinada , Estudos Retrospectivos , Hipertermia Induzida/métodos , Abdome , Hospitalização , Procedimentos Cirúrgicos de Citorredução/métodos , Taxa de Sobrevida , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
6.
Phys Med ; 117: 103195, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38048731

RESUMO

PURPOSE: To develop a machine learning-based methodology for patient-specific radiation dosimetry in thoracic and abdomen CT. METHODS: Three hundred and thirty-one thoracoabdominal radiotherapy-planning CT examinations with the respective organ/patient contours were collected retrospectively for the development and validation of segmentation 3D-UNets. Moreover, 97 diagnostic thoracic and 89 diagnostic abdomen CT examinations were collected retrospectively. For each of the diagnostic CT examinations, personalized MC dosimetry was performed. The data derived from MC simulations along with the respective CT data were used for the training and validation of a dose prediction deep neural network (DNN). An algorithm was developed to utilize the trained models and perform patient-specific organ dose estimates for thoracic and abdomen CT examinations. The doses estimated with the DNN were compared with the respective doses derived from MC simulations. A paired t-test was conducted between the DNN and MC results. Furthermore, the time efficiency of the proposed methodology was assessed. RESULTS: The mean percentage differences (range) between DNN and MC dose estimates for the lungs, liver, spleen, stomach, and kidneys were 7.2 % (0.2-24.1 %), 5.5 % (0.4-23.0 %), 7.9 % (0.6-22.3 %), 6.9 % (0.0-23.0 %) and 6.7 % (0.3-22.6 %) respectively. The differences between DNN and MC dose estimates were not significant (p-value = 0.12). Moreover, the mean processing time of the proposed workflow was 99 % lower than the respective time needed for MC-based dosimetry. CONCLUSIONS: The proposed methodology can be used for rapid and accurate patient-specific dosimetry in chest and abdomen CT.


Assuntos
Radiometria , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Aprendizado de Máquina , Doses de Radiação , Abdome/diagnóstico por imagem
7.
Abdom Radiol (NY) ; 49(3): 942-957, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38102443

RESUMO

PURPOSE: To explore the feasibility of a 5G-based telerobotic ultrasound (US) system for providing qualified abdominal US services on a rural island. METHODS: This prospective study involved two medical centers (the tele-radiologist site's hospital and the patient site's hospital) separated by 72 km. Patients underwent 5G-based telerobotic US by tele-radiologists and conventional US by on-site radiologists from September 2020 to March 2021. The clinical feasibility and diagnostic performance of the 5G-based telerobotic abdominal US examination were assessed based on safety, duration, image quality, diagnostic findings, and questionnaires. RESULTS: A total of 401 patients (217 women and 184 men; mean age, 54.96 ± 15.43 years) were enrolled. A total of 90.1% of patients indicated no discomfort with the telerobotic US examination. For the examination duration, telerobotic US took longer than conventional US (12.54 ± 3.20 min vs. 7.23 ± 2.10 min, p = 0.001). For image quality scores, the results of the two methods were similar (4.54 ± 0.63 vs. 4.57 ± 0.61, p = 0.112). No significant differences were found between the two methods in measurements for the aorta, portal vein, gallbladder, kidney (longitudinal diameter), prostate, and uterus; however, telerobotic US underestimated the transverse diameter of the kidney (p < 0.05). A total of 504 positive results, including 31 different diseases, were detected. Among them, 455 cases were identified by the two methods; 17 cases were identified by telerobotic US only; and 32 cases were identified by conventional US only. There was good consistency in the diagnosis of 29 types of disease between the two methods (κ = 0.773-1.000). Furthermore, more than 90% of patients accepted the telerobotic US examination and agreed to pay additional fees in future. CONCLUSION: The 5G-based telerobotic US system can expand access to abdominal US services for patients in rural areas, thereby reducing health care disparities.


Assuntos
Robótica , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Robótica/métodos , Ultrassonografia , Abdome/diagnóstico por imagem , Rim
8.
Artigo em Inglês | MEDLINE | ID: mdl-38082821

RESUMO

Estimating skeletal muscle (SM) and adipose tissues is an invaluable prognostic indicator in cancer treatment, major surgeries, and general health screening. Body composition is usually measured with abdominal computed tomography (CT) scans acquired in clinical settings. The whole-body SM volume is correlated with the estimated SM based on the measurement of a single two-dimensional vertebral slice. It is necessary to label a CT image at the pixel level to estimate SM, known as semantic segmentation. In this work, we trained a segmentation model using the labeled abdominal CT slices and the additional unlabeled slices. In particular, we trained two identical segmentation networks with differently initialized weights. Network Consistency Learning (NCL) allowed learning from unlabeled images by forcing the predictions from both networks to be the same. We segmented abdominal CT images from a newly created in-house dataset. The proposed approach gained 10% better performance in terms of Dice similarity score (DSC) than that obtained by a standard supervised network demonstrating the effectiveness of NCL in exploiting unlabeled images.Clinical relevance- An efficient and cost-effective method is proposed for assessing body composition from limited labeled and abundant unlabeled CT images to facilitate fast diagnosis, prognosis, and interventions.


Assuntos
Abdome , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Composição Corporal , Tecido Adiposo , Músculo Esquelético
9.
Sensors (Basel) ; 23(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38139620

RESUMO

(1) Background: Technically, a simple, inexpensive, and non-invasive method of ascertaining volume changes in thoracic and abdominal cavities are required to expedite the development and validation of pulmonary mechanics models. Clinically, this measure enables the real-time monitoring of muscular recruitment patterns and breathing effort. Thus, it has the potential, for example, to help differentiate between respiratory disease and dysfunctional breathing, which otherwise can present with similar symptoms such as breath rate. Current automatic methods of measuring chest expansion are invasive, intrusive, and/or difficult to conduct in conjunction with pulmonary function testing (spontaneous breathing pressure and flow measurements). (2) Methods: A tape measure and rotary encoder band system developed by the authors was used to directly measure changes in thoracic and abdominal circumferences without the calibration required for analogous strain-gauge-based or image processing solutions. (3) Results: Using scaling factors from the literature allowed for the conversion of thoracic and abdominal motion to lung volume, combining motion measurements correlated to flow-based measured tidal volume (normalised by subject weight) with R2 = 0.79 in data from 29 healthy adult subjects during panting, normal, and deep breathing at 0 cmH2O (ZEEP), 4 cmH2O, and 8 cmH2O PEEP (positive end-expiratory pressure). However, the correlation for individual subjects is substantially higher, indicating size and other physiological differences should be accounted for in scaling. The pattern of abdominal and chest expansion was captured, allowing for the analysis of muscular recruitment patterns over different breathing modes and the differentiation of active and passive modes. (4) Conclusions: The method and measuring device(s) enable the validation of patient-specific lung mechanics models and accurately elucidate diaphragmatic-driven volume changes due to intercostal/chest-wall muscular recruitment and elastic recoil.


Assuntos
Mecânica Respiratória , Parede Torácica , Adulto , Humanos , Mecânica Respiratória/fisiologia , Diafragma/fisiologia , Pulmão/fisiologia , Abdome
10.
Rev Col Bras Cir ; 50: e20233512, 2023.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37971114

RESUMO

BACKGROUND: training in critical surgical situations is crucial for a safe outcome. The use of simulators is well established, although many are quite expensive, requiring the search for financially viable solutions for training centers. METHODS: we built a low-cost simulator for intra-abdominal bleeding with inexpensive materials, such as a manikin chest, latex tubes, silicone rubber, and waterproof fabric, seeking to mimic the abdominal viscera and vessels and their anatomical correlations. An IV infusion set allowed simulated blood to flow under pressure, and the blood flowed freely during simulation. After obtaining a functional model, we selected general surgeons to validate the simulator and its use in teaching surgery. We used the content validity index (CVI), with a cutoff of 0.9. RESULTS: the cost of building the prototype was US$71,00 in 2021, accounting for the purchase of the various necessary materials. Twelve raters participated in the validation tests. The results obtained from the feedback survey showed a good evaluation of all items, especially the recognition of the injured vessel, access to the vascular injury, hemostasis by manual compression, and hemostatic suturing. CONCLUSION: the proposed simulator obtained good results in scenarios of intra-abdominal bleeding from large vessels, as well as for hemostasis by manual compression and suturing. It proved to be a useful tool for training in critical intra- abdominal bleeding situations, while maintaining a low cost of building.


Assuntos
Hemostáticos , Cirurgiões , Humanos , Simulação por Computador , Abdome , Competência Clínica
11.
Radiol Imaging Cancer ; 5(6): e230036, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37999629

RESUMO

Purpose To evaluate the feasibility of liver MR fingerprinting (MRF) for quantitative characterization and diagnosis of focal liver lesions. Materials and Methods This single-site, prospective study included 89 participants (mean age, 62 years ± 15 [SD]; 45 women, 44 men) with various focal liver lesions who underwent MRI between October 2021 and August 2022. The participants underwent routine clinical MRI, non-contrast-enhanced liver MRF, and reference quantitative MRI with a 1.5-T MRI scanner. The bias and repeatability of the MRF measurements were assessed using linear regression, Bland-Altman plots, and coefficients of variation. The diagnostic capability of MRF-derived T1, T2, T2*, proton density fat fraction (PDFF), and a combination of these metrics to distinguish benign from malignant lesions was analyzed according to the area under the receiver operating characteristic curve (AUC). Results Liver MRF measurements showed moderate to high agreement with reference measurements (intraclass correlation = 0.94, 0.77, 0.45, and 0.61 for T1, T2, T2*, and PDFF, respectively), with underestimation of T2 values (mean bias in lesion = -0.5%, -29%, 5.8%, and -8.2% for T1, T2, T2*, and PDFF, respectively). The median coefficients of variation for repeatability of T1, T2, and T2* values were 2.5% (IQR, 3.6%), 3.1% (IQR, 5.6%), and 6.6% (IQR, 13.9%), respectively. After considering multicollinearity, a combination of MRF measurements showed a high diagnostic performance in differentiating benign from malignant lesions (AUC = 0.92 [95% CI: 0.86, 0.98]). Conclusion Liver MRF enabled the quantitative characterization of various focal liver lesions in a single breath-hold acquisition. Keywords: MR Imaging, Abdomen/GI, Liver, Imaging Sequences, Technical Aspects, Tissue Characterization, Technology Assessment, Diagnosis, Liver Lesions, MR Fingerprinting, Quantitative Characterization Supplemental material is available for this article. © RSNA, 2023.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Abdome , Prótons , Neoplasias Hepáticas/diagnóstico por imagem
13.
Med Image Anal ; 90: 102986, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37820418

RESUMO

Renal tubular structures, such as ureters, arteries and veins, are very important for building a complete digital 3D anatomical model of a patient. However, they can be challenging to segment from ceCT images due to their elongated shape, diameter variation and intra- and inter-patient contrast heterogeneity. This task is even more difficult in pediatric and pathological subjects, due to high inter-subject anatomical variations, potential presence of tumors, small volume of these structures compared to the surrounding, and small available labeled datasets. Given the limited literature on methods dedicated to children, and in order to find inspirational approaches, a complete assessment of state-of-the-art methods for the segmentation of renal tubular structures on ceCT images on adults is presented. Then, these methods are tested and compared on a private pediatric and pathological dataset of 79 abdominal-visceral ceCT images with arteriovenous phase acquisitions. To the best of our knowledge, both assessment and comparison in this specific case are novel. Eventually, we also propose a new loss function which leverages for the first time the use of vesselness functions on the predicted segmentation. We show that the combination of this loss function with state-of-the-art methods improves the topological coherence of the segmented tubular structures.2.


Assuntos
Abdome , Neoplasias Renais , Humanos , Criança , Neoplasias Renais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador
15.
Radiol Phys Technol ; 16(4): 506-515, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37648948

RESUMO

We propose a novel method for calculating the effective dose that closely reflects the individual attenuation, utilizing two conversion coefficients. A total of 180 adult patients who underwent abdomen-pelvis computed tomography were categorized into six groups based on sex and body type. The effective dose was calculated by multiplying the dose-length product with the effective dose conversion coefficient and the size-specific dose estimate conversion factor. The effective dose calculated using a simulation-based dose calculator (WAZA-ARI) was employed as the reference value. The following values, obtained through both methods, were compared within each category: distribution of the effective dose, median effective dose, and relative difference in median effective dose across additional body mass index (BMI) categories. For male patients, no significant disparity was observed in the median effective doses calculated using the two methods. The relative differences in median effective doses across additional BMI categories ranged from - 5 to 6%. Conversely, among female patients, the median effective dose calculated using our method slightly undercut that calculated using WAZA-ARI, with relative differences ranging from - 16 to - 9%. Additionally, relative differences in median effective dose across additional BMI categories ranged from - 18 to - 7%. The median effective dose differed slightly depending on the calculation method because of the different reference phantoms applied in dose calculations. Our proposed method is sensitive to individual size and helps compute a size-specific effective dose.


Assuntos
Abdome , Tomografia Computadorizada por Raios X , Adulto , Humanos , Masculino , Feminino , Doses de Radiação , Abdome/diagnóstico por imagem , Simulação por Computador , Tomografia Computadorizada por Raios X/métodos , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Método de Monte Carlo
16.
Traffic Inj Prev ; 24(sup1): S16-S22, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37267003

RESUMO

OBJECTIVE: The objective of this study was the quantitative evaluation and comparison of the responses of the Hybrid III 5th percentile female (HIII-05F) and the 5th percentile female Test Device for Human Occupant Restraint (THOR-05F) anthropomorphic test devices (ATDs) subjected to abdominal loading conditions. METHOD: The HIII-05F and THOR-05F were subjected to 3 different abdominal loading conditions: fixed-back belt pull (low compression), fixed-back belt pull (high compression), and free-back rigid bar impact at 6 m/s. The stroke of the impact was controlled to represent injurious and noninjurious loading conditions as observed in the experiments with postmortem human subjects (PMHS). Quantitative comparisons were made between the ATD abdominal force and compression responses and biofidelity corridors obtained from matched-pair PMHS tests under identical loading conditions, using the most recent version of the NHTSA Biofidelity Ranking System (BRS). RESULTS: The overall THOR-05F BRS scores across all tests (BRS score = 1.84) indicated good biofidelity. For the belt loading test conditions, the average BRS scores for both THOR-05F (BRS scores = 1.45 and 1.34) and HIII-05F (BRS scores = 1.42 and 1.01) showed good biofidelity. For the rigid bar loading condition, the THOR-05F (BRS score = 2.74) showed better biofidelity compared to HIII-05F (BRS score = 10.63), with the HIII-05F exhibiting poor performance in this condition. The average pressures recorded by the abdomen pressure twin sensors (APTS) in the current study ranged from 45 to 130 kPa, increasing proportionally with higher stroke and loading rate. CONCLUSIONS: Overall, the THOR-05F BRS scores were better than the HIII-05F BRS scores, which suggests improved biofidelity of the THOR-05F abdomen. The abdominal insert in the HIII-05F did not provide enough room for compression, leading to higher stiffness and occupant motion as observed in the rigid bar tests. Because of practical challenges in measuring abdomen deflection in a soft ATD abdomen component, use of APTS in THOR-05F provides the ability to measure the restraint loading to the abdomen and assess the risk of abdominal injury. With good BRS scores observed in this study for THOR-05F, pressure and other measurements included in the THOR-05F may be used to develop abdominal injury risk functions in the future.


Assuntos
Traumatismos Abdominais , Acidentes de Trânsito , Humanos , Feminino , Cadáver , Abdome/fisiologia , Restrição Física , Fenômenos Biomecânicos , Manequins
18.
Eur Rev Med Pharmacol Sci ; 27(8): 3344-3350, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37140284

RESUMO

OBJECTIVE: The caudate lobe differs from the rest of the liver. This study was planned to evaluate the caudate lobe's morphology, morphometry, and vascular structures using computed tomography (CT). PATIENTS AND METHODS: Three hundred eighty-eight cases were evaluated retrospectively in terms of caudate lobe morphology, morphometry, and vascular anatomy from patients undergoing contrast-enhanced abdominal CT for any reason between September 2018 and December 2019. After the application of exclusion criteria, 196 patients were eventually included in the study. RESULTS: One hundred seventeen (59.7%) of the 196 patients were men. The patients' mean age was 57.88 years (ranging from 18 to 82). Morphologically, the caudate lobe was classified as rectangular, piriform, or irregular-shaped, with 117 cases being evaluated as piriform (59.7%), 51 as irregular-shaped (26%), and 28 as rectangular (14.3%). The caudate process was visible in most cases (92.9%). No papillary process was observed in the great majority of patients (87.2%). CONCLUSIONS: Caudate lobe evaluation criteria can be obtained using CT in vivo based on morphological and morphometric values for the caudate lobes yielded by cadaver studies.


Assuntos
Neoplasias Hepáticas , Fígado , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/irrigação sanguínea , Tomografia Computadorizada por Raios X , Abdome
19.
J Gastrointest Surg ; 27(7): 1473-1485, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37081221

RESUMO

OBJECTIVES: To perform a systematic review on the use of magnetic resonance imaging (MRI) of the abdomen to evaluate clinically suspected appendicitis in the general adult population. We examined the diagnostic accuracy, the reported trends of MRI use, and the factors that affect the utility of MRI abdomen, including study duration and cost-benefits. METHODS: We conducted a systematic literature search on PubMed, MEDLINE, Embase, Web of Science, and Cochrane Library databases. We enrolled primary studies investigating the use of MRI in diagnosing appendicitis in the general adult population, excluding studies that predominantly reported on populations not representative of typical adult appendicitis presentations, such as those focusing on paediatric or pregnant populations. RESULTS: Twenty-seven eligible primary studies and 6 secondary studies were included, totaling 2,044 patients from eight countries. The sensitivity and specificity of MRI for diagnosing appendicitis were 96% (95% CI: 93-97%) and 93% (95% CI: 80-98%), respectively. MRI can identify complicated appendicitis and accurately propose alternative diagnoses. The duration of MRI protocols in each primary study ranged between 2.26 and 30 minutes, and only one study used intravenous contrast agents in addition to the non-contrast sequences. Decision analysis suggests significant benefits for replacing computed tomography (CT) with MRI and a potential for cost reduction. Reported trends in MRI usage showed minimal utilisation in diagnostic settings even when MRI was available. CONCLUSIONS: MRI accurately diagnoses appendicitis in the general adult population and improves the identification of complicated appendicitis or alternative diagnoses compared to other modalities using a single, rapid investigation.


Assuntos
Apendicite , Feminino , Gravidez , Humanos , Adulto , Criança , Apendicite/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Sensibilidade e Especificidade , Abdome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA