Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.093
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 13(13): e035171, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38904248

RESUMO

BACKGROUND: Cervical arterial tortuosity is associated with adverse outcomes in Loeys-Dietz syndrome and other heritable aortopathies. METHODS AND RESULTS: A method to assess tortuosity based on curvature of the vessel centerline in 3-dimensional space was developed. We measured cervical carotid tortuosity in 65 patients with Loeys-Dietz syndrome from baseline computed tomography angiogram/magnetic resonance angiogram and all serial images during follow-up. Relations between baseline carotid tortuosity, age, aortic root diameter, and its change over time were compared. Patients with unoperated aortic roots were assessed for clinical end point (type A aortic dissection or aortic root surgery during 4 years of follow-up). Logistic regression was performed to assess the likelihood of clinical end point according to baseline carotid tortuosity. Total absolute curvature at baseline was 11.13±5.76 and was relatively unchanged at 8 to 10 years (fold change: 0.026±0.298, P=1.00), whereas tortuosity index at baseline was 0.262±0.131, with greater variability at 8 to 10 years (fold change: 0.302±0.656, P=0.818). Baseline total absolute curvature correlated with aortic root diameter (r=0.456, P=0.004) and was independently associated with aortic events during the 4-year follow-up (adjusted odds ratio [OR], 2.64 [95% CI, 1.02-6.85]). Baseline tortuosity index correlated with age (r=0.532, P<0.001) and was not associated with events (adjusted OR, 1.88 [95% CI, 0.79-4.51]). Finally, baseline total absolute curvature had good discrimination of 4-year outcomes (area under the curve=0.724, P=0.014), which may be prognostic or predictive. CONCLUSIONS: Here we introduce cervical carotid tortuosity as a promising quantitative biomarker with validated, standardized characteristics. Specifically, we recommend the adoption of a curvature-based measure, total absolute curvature, for early detection or monitoring of disease progression in Loeys-Dietz syndrome.


Assuntos
Artérias Carótidas , Angiografia por Tomografia Computadorizada , Síndrome de Loeys-Dietz , Angiografia por Ressonância Magnética , Humanos , Feminino , Masculino , Medição de Risco , Adulto , Síndrome de Loeys-Dietz/genética , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/diagnóstico por imagem , Pessoa de Meia-Idade , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Fatores de Risco , Adulto Jovem , Valor Preditivo dos Testes , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/diagnóstico , Imageamento Tridimensional , Reprodutibilidade dos Testes , Dermatopatias Genéticas/genética , Dermatopatias Genéticas/diagnóstico por imagem , Dermatopatias Genéticas/diagnóstico
2.
Acta Neurochir (Wien) ; 166(1): 203, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38713241

RESUMO

PURPOSE: Stroke, the second leading cause of death globally, often involves ischemia in the vertebrobasilar territory. This condition is underexplored, despite significant morbidity and mortality risks. The purpose of this study is to present a case of occipital artery to V3 segment vertebral artery bypass, emphasizing the role of quantitative magnetic resonance angiography (qMRA) in assessing flow and guiding surgical intervention. METHODS: A 66-year-old man with bilateral vertebral artery occlusion presented acute symptoms. qMRA was employed to evaluate flow dynamics and determine the feasibility of a flow augmentation bypass surgery. The occipital artery to left vertebral artery bypass (OA-to-VA) was performed, utilizing an inverted hockey-stick incision and an antegrade inside-out technique. The patency of the bypass was confirmed using both Doppler probe and Indocyanine green. RESULTS: Postoperative assessments, including computed tomography angiography (CTA) and qMRA, demonstrated the patency of the bypass with improved flow in the basilar artery and left vertebral artery. The patient's condition remained stable postoperatively, with residual peripheral palsy of the left facial nerve. CONCLUSION: In conclusion, the presented case illustrates the efficacy of the OA-to-VA bypass in addressing symptomatic bilateral vertebral artery occlusion. The study underscores the pivotal role of qMRA in pre- and postoperative assessments, providing noninvasive flow quantification for diagnostic considerations and long-term follow-up in patients with vertebrobasilar insufficiency.


Assuntos
Revascularização Cerebral , Angiografia por Ressonância Magnética , Artéria Vertebral , Insuficiência Vertebrobasilar , Humanos , Masculino , Idoso , Insuficiência Vertebrobasilar/cirurgia , Insuficiência Vertebrobasilar/diagnóstico por imagem , Artéria Vertebral/cirurgia , Artéria Vertebral/diagnóstico por imagem , Revascularização Cerebral/métodos , Angiografia por Ressonância Magnética/métodos , Resultado do Tratamento
3.
Radiography (Lond) ; 30(4): 1116-1124, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38797044

RESUMO

INTRODUCTION: Information on tissue perfusion in the foot is important when treating patients with chronic limb-threatening ischemia. This study aims to test the reliability of different magnetic resonance sequences when measuring perfusion in the foot. METHODS: Sixteen healthy volunteers had their right foot scanned in a test/retest study with six different magnetic resonance sequences (BOLD, multi-echo gradient echo (mGRE), 2D and 3D pCASL, PASL FAIR, and DWI with intravoxel incoherent motion (IVIM) with quantitative measurements of perfusion. For five sequences, cuff-induced ischemia followed by a hyperactive response was measured. Images of the feet were segmented into angiosomes and perfusion data were extracted from the five angiosomes. RESULTS: BOLD, PASL FAIR, mGRE, and DWI with IVIM had low mean differences between the first and second scans, while the results of 2D and 3D pCASL had the highest differences. Based on a paired t-test, BOLD, and FAIR were able to distinguish between perfusion and no perfusion in all angiosomes with p-values below 0.01. This was not the case with 2D and 3D pCASL with p-values above 0.05 in all angiosomes. The mGRE could not distinguish between perfusion and no perfusion in the lateral side of the foot. CONCLUSION: BOLD, mGRE, pASL FAIR, and DWI with IVIM seem to give more robust results compared to 2D and 3D pCASL. Further studies on patients with peripheral artery disease should explore if the sequences can have clinical relevance when assessing tissue ischemia and results of revascularization. IMPLICATIONS FOR PRACTICE: This study provides knowledge that could be used to improve the diagnosis of patient with chronic limb-threatening ischemia to explore tissue perfusion.


Assuntos
, Doença Arterial Periférica , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Pé/irrigação sanguínea , Pé/diagnóstico por imagem , Masculino , Feminino , Adulto , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Voluntários Saudáveis , Isquemia/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos
4.
Comput Biol Med ; 172: 108207, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38489986

RESUMO

Artificial Intelligence (AI) techniques are increasingly used in computer-aided diagnostic tools in medicine. These techniques can also help to identify Hypertension (HTN) in its early stage, as it is a global health issue. Automated HTN detection uses socio-demographic, clinical data, and physiological signals. Additionally, signs of secondary HTN can also be identified using various imaging modalities. This systematic review examines related work on automated HTN detection. We identify datasets, techniques, and classifiers used to develop AI models from clinical data, physiological signals, and fused data (a combination of both). Image-based models for assessing secondary HTN are also reviewed. The majority of the studies have primarily utilized single-modality approaches, such as biological signals (e.g., electrocardiography, photoplethysmography), and medical imaging (e.g., magnetic resonance angiography, ultrasound). Surprisingly, only a small portion of the studies (22 out of 122) utilized a multi-modal fusion approach combining data from different sources. Even fewer investigated integrating clinical data, physiological signals, and medical imaging to understand the intricate relationships between these factors. Future research directions are discussed that could build better healthcare systems for early HTN detection through more integrated modeling of multi-modal data sources.


Assuntos
Hipertensão , Medicina , Humanos , Inteligência Artificial , Eletrocardiografia , Hipertensão/diagnóstico por imagem , Angiografia por Ressonância Magnética
5.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38440807

RESUMO

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Assuntos
Artérias Cerebrais , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Humanos , Feminino , Masculino , Adulto , Idoso , Reprodutibilidade dos Testes , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiologia , Fluxo Pulsátil/fisiologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto Jovem , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
7.
J Vasc Res ; 61(3): 122-128, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38547846

RESUMO

INTRODUCTION: We aimed to compare conventional vessel wall MR imaging techniques and quantitative susceptibility mapping (QSM) to determine the optimal sequence for detecting carotid artery calcification. METHODS: Twenty-two patients who underwent carotid vessel wall MR imaging and neck CT were enrolled. Four slices of 6-mm sections from the bilateral internal carotid bifurcation were subdivided into 4 segments according to clock position (0-3, 3-6, 6-9, and 9-12) and assessed for calcification. Two blinded radiologists independently reviewed a total of 704 segments and scored the likelihood of calcification using a 5-point scale on spin-echo imaging, FLASH, and QSM. The observer performance for detecting calcification was evaluated by a multireader, multiple-case receiver operating characteristic study. Weighted κ statistics were calculated to assess interobserver agreement. RESULTS: QSM had a mean area under the receiver operating characteristic curve of 0.85, which was significantly higher than that of any other sequence (p < 0.01) and showed substantial interreader agreement (κ = 0.68). A segment with a score of 3-5 was defined as positive, and a segment with a score of 1-2 was defined as negative; the sensitivity and specificity of QSM were 0.75 and 0.87, respectively. CONCLUSION: QSM was the most reliable MR sequence for the detection of plaque calcification.


Assuntos
Doenças das Artérias Carótidas , Variações Dependentes do Observador , Placa Aterosclerótica , Valor Preditivo dos Testes , Calcificação Vascular , Humanos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/patologia , Reprodutibilidade dos Testes , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/patologia , Imageamento por Ressonância Magnética
8.
PLoS One ; 19(2): e0297314, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38330070

RESUMO

Cardiac MRI is a crucial tool for assessing congenital heart disease (CHD). However, its application remains challenging in young children when performed at 3T. The aim of this retrospective single center study was to compare a non-contrast free-breathing 2D CINE T1-weighted TFE-sequence with compressed sensing (FB 2D CINE CS T1-TFE) with 3D imaging for diagnostic accuracy of CHD, image quality, and vessel diameter measurements in sedated young children. FB 2D CINE CS T1-TFE was compared with a 3D non-contrast whole-heart sequence (3D WH) and 3D contrast-enhanced MR angiography (3D CE-MRA) at 3T in 37 CHD patients (20♂, 1.5±1.4 years). Two radiologists independently assessed image quality, type of CHD, and diagnostic confidence. Diameters and measures of contrast and sharpness of the aorta and pulmonary vessels were determined. A non-parametric multi-factorial approach was used to estimate diagnostic accuracy for the diagnosis of CHD. Linear mixed models were calculated to compare contrast and vessel sharpness. Krippendorff's alpha was determined to quantify vessel diameter agreement. FB 2D CINE CS T1-TFE was rated superior regarding image quality, diagnostic confidence, and diagnostic sensitivity for both intra- and extracardiac pathologies compared to 3D WH and 3D CE-MRA (all p<0.05). FB 2D CINE CS T1-TFE showed superior contrast and vessel sharpness (p<0.001) resulting in the highest proportion of measurable vessels (740/740; 100%), compared to 3D WH (530/620; 85.5%) and 3D CE-MRA (540/560; 96.4%). Regarding vessel diameter measurements, FB 2D CINE CS T1-TFE revealed the closest inter-reader agreement (Krippendorff's alpha: 0.94-0.96; 3D WH: 0.78-0.94; 3D CE-MRA: 0.76-0.93). FB 2D CINE CS T1-TFE demonstrates robustness at 3T and delivers high-quality diagnostic results to assess CHD in sedated young children. Its ability to function without contrast injection and respiratory compensation enhances ease of use and could encourage widespread adoption in clinical practice.


Assuntos
Meios de Contraste , Cardiopatias Congênitas , Criança , Humanos , Pré-Escolar , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
9.
Clin Imaging ; 107: 110088, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38277858

RESUMO

PURPOSE: To evaluate relative and absolute utilization trends and practice patterns in the United States for MRA and CTA. METHODS: Using Medicare Part B physician payment databases (2013-2020), MRA and CTA interpreting physicians and exams were identified using the unique MRA and CTA Healthcare Common Procedure Coding System codes. The number of exams, physicians, demographics, use of contrast, and payments were summarized annually and analyzed to evaluate trends before and during the first year of the COVID-19 pandemic. RESULTS: From 2013 to 2019, the annual number of MRA exams performed decreased by 17.9 %, while the number of CTA exams increased by 90.3 %. The number of physicians interpreting MRA decreased in both hospital (-17.2 %) and outpatient (-7.5 %) environments. The number of physicians interpreting CTA increased in both hospital (+29.4 %) and outpatient (+54.3 %) environments. During the first year of the COVID-19 pandemic, MRA utilization decreased across all imaging environments by 25.0 % whereas CTA only decreased by 5.5 %. Intracranial MRA studies were most often performed without contrast, while contrast use for neck MRA was performed at similar rates as non-contrast exams. CONCLUSION: The overall utilization of MRA and the number of interpreting physicians are decreasing. On the other hand, CTA use and its number of interpreting physicians are increasing. During the first year of the COVID-19 pandemic, use of both MRA and CTA decreased, but the utilization of MRA decreased at five times the rate of CTA.


Assuntos
COVID-19 , Medicare Part B , Idoso , Humanos , Estados Unidos/epidemiologia , Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética/métodos , Pandemias , Espectroscopia de Ressonância Magnética , COVID-19/epidemiologia
11.
AJNR Am J Neuroradiol ; 45(2): 155-162, 2024 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-38238091

RESUMO

BACKGROUND AND PURPOSE: Collateral circulation plays an important role in steno-occlusive internal carotid artery disease (ICAD) to reduce the risk of stroke. We aimed to investigate the utility of planning-free random vessel-encoded arterial spin-labeling (rVE-ASL) in assessing collateral flows in patients with ICAD. MATERIALS AND METHODS: Forty patients with ICAD were prospectively recruited. The presence and extent of collateral flow were assessed and compared between rVE-ASL and DSA by using Contingency (C) and Cramer V (V) coefficients. The differences in flow territory alterations stratified by stenosis ratio and symptoms, respectively, were compared between symptomatic (n = 19) and asymptomatic (n = 21) patients by using the Fisher exact test. RESULTS: Good agreement was observed between rVE-ASL and DSA in assessing collateral flow (C = 0.762, V = 0.833, both P < .001). Patients with ICA stenosis of ≥90% were more likely to have flow alterations (P < .001). Symptomatic patients showed a higher prevalence of flow alterations in the territory of the MCA on the same side of ICAD (63.2%), compared with asymptomatic patients (23.8%, P = .012), while the flow alterations in the territory of anterior cerebral artery did not differ (P = .442). The collateral flow to MCA territory was developed primarily from the contralateral internal carotid artery (70.6%) and vertebrobasilar artery to a lesser extent (47.1%). CONCLUSIONS: rVE-ASL provides comparable information with DSA on the assessment of collateral flow. The flow alterations in the MCA territory may be attributed to symptomatic ICAD.


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Humanos , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Marcadores de Spin , Angiografia Digital , Artéria Carótida Interna/diagnóstico por imagem , Circulação Colateral , Circulação Cerebrovascular , Angiografia por Ressonância Magnética
12.
Acad Radiol ; 31(6): 2405-2411, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38142177

RESUMO

RATIONALE AND OBJECTIVES: Early diagnosis of transplant renal artery stenosis (TRAS) is crucial for salvaging kidney function and improving patient prognosis. The purpose of this study was to evaluate image quality of non-contrast-enhanced MR angiography (NCE-MRA) and the value of NCE-MRA in evaluating TRAS compared to DSA. MATERIALS AND METHODS: In 60 patients with TRAS confirmed by DSA, the degree of TRAS was assessed using balanced triggered angiography non-contrast-enhanced (B-TRANCE) MR angiography and was compared to that of DSA. Image quality for NCE-MRA was assessed independently by two radiologists. The Wilcoxon signed-rank test was used to compare NCE-MRA with DSA in assessing TRAS degree. Specificity, sensitivity, accuracy, positive-predictive value (PPV), and negative-predictive value (NPV) of NCE-MRA for the detection of marked (≥50%) TRAS were calculated. RESULTS: The image quality of NCE-MRA based on the B-TRANCE technology of transplanted renal arteries was sufficient (excellent in 81.67%, good in 8.33%, moderate in 6.67%, and non-diagnostic in 3.33%) and had a high inter-observer reproducibility (Kappa=0.836). DSA helped identify severe, moderate, and mild stenosis in 6, 32, and 22 arteries, respectively. No significant difference in the extent of TRAS between NCE-MRA and DSA were observed (P = 0.317). The specificity, sensitivity, accuracy, PPV, and NPV of NCE-MRA in detecting marked (≥50%) TRAS were 90.91%, 100%, 96.55%, 94.74%, and 100%, respectively. CONCLUSION: NCE-MRA based on B-TRANCE technology has shown promising consistency with DSA in evaluating TRAS and yielding high sensitivity, specificity, and accuracy in assessing the severity of TRAS.


Assuntos
Angiografia Digital , Transplante de Rim , Angiografia por Ressonância Magnética , Obstrução da Artéria Renal , Sensibilidade e Especificidade , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Masculino , Feminino , Angiografia Digital/métodos , Pessoa de Meia-Idade , Adulto , Reprodutibilidade dos Testes , Idoso , Meios de Contraste
14.
Clin Neuroradiol ; 33(4): 1115-1122, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37401949

RESUMO

PURPOSE: The 3D time-of-flight (TOF) magnetic resonance angiography (MRA) at 3T shows high sensitivity for intracranial aneurysms but is inferior to three-dimensional digital subtraction angiography (3D-DSA) regarding aneurysm characteristics. We applied an ultra-high-resolution (UHR) TOF-MRA using compressed sensing reconstruction to investigate the diagnostic performance in preinterventional evaluation of intracranial aneurysms compared to conventional TOF-MRA and 3D-DSA. METHODS: In this study 17 patients with unruptured intracranial aneurysms were included. Aneurysm dimensions, configuration, image quality and sizing of endovascular devices were compared between conventional TOF-MRA at 3T and UHR-TOF with 3D-DSA as gold standard. Quantitatively, contrast-to-noise ratios (CNR) were compared between TOF-MRAs. RESULTS: On 3D-DSA, 25 aneurysms in 17 patients were detected. On conventional TOF, 23 aneurysms were detected (sensitivity: 92.6%). On UHR-TOF, 25 aneurysms were detected (sensitivity: 100%). Image quality was not significantly different between TOF and UHR-TOF (p = 0.17). Aneurysm dimension measurements were significantly different between conventional TOF (3.89 mm) and 3D-DSA (4.2 mm, p = 0.08) but not between UHR-TOF (4.12 mm) and 3D-DSA (p = 0.19). Irregularities and small vessels at the aneurysm neck were more frequently correctly depicted on UHR-TOF compared to conventional TOF. Comparison of the planned framing coil diameter and flow-diverter (FD) diameter revealed neither a statistically significant difference between TOF and 3D-DSA (coil p = 0.19, FD p = 0.45) nor between UHR-TOF and 3D-DSA (coil: p = 0.53, FD 0.33). The CNR was significantly higher in conventional TOF (p = 0.009). CONCLUSION: In this pilot study, ultra-high-resolution TOF-MRA visualized all aneurysms and accurately depicted aneurysm irregularities and vessels at the base of the aneurysm comparably to DSA, outperforming conventional TOF. UHR-TOF with compressed sensing reconstruction seems to represent a non-invasive alternative to pre-interventional DSA for intracranial aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/patologia , Seguimentos , Projetos Piloto , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/métodos , Sensibilidade e Especificidade
16.
Neurosurgery ; 92(6): 1243-1248, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36744923

RESUMO

BACKGROUND: Digital subtraction angiography (DSA) assesses revascularization in pediatric moyamoya patients after surgery, but MRI and angiography (MRI/A) may provide comparable data. OBJECTIVE: To evaluate DSA and MRI/A with respect to clinical utility in postoperative follow-up, complication profile, and relative cost at 1 year. METHODS: All pediatric moyamoya patients who received bilateral indirect revascularization between 2011 and 2020 were retrospectively reviewed at 1 institution. Patients who underwent MRI/A-only, DSA-only, or both after 1 year were compared. RESULTS: Eighty-two patients were included. At 1 year, patients who underwent either MRI/A (n = 29) or DSA (n = 40) had no significant differences in detection rate of new at-risk hypovascular territories (6.9% vs 2.5%, P = .568) or need for subsequent revascularization beyond the mean 40 ± 24-month follow-up period (3.4% vs 5.0%, P > .9). Among patients who underwent both MRI/A and DSA (n = 13), both studies identified the same at-risk territories. No patients experienced MRI/A-related complications, compared with 3 minor DSA-related complications. The use of MRI/A yielded a 6.5-fold reduction in cost per study vs DSA at 1 year. CONCLUSION: Using DSA to follow moyamoya patients after indirect revascularization is generally safe but associated with a low rate of minor complications and a 6.5-fold greater financial cost relative to MRI/A. These data support changing practice to eliminate the use of DSA when following routine bilateral moyamoya cases in the absence of clinical symptoms or specific concerns. Using MRI/A as the primary postoperative follow-up modality in this select population provides noninferior care and greater patient access, while reducing cost and potentially decreasing risk.


Assuntos
Revascularização Cerebral , Doença de Moyamoya , Humanos , Criança , Seguimentos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/cirurgia , Angiografia Digital/métodos , Revascularização Cerebral/métodos , Complicações Pós-Operatórias
17.
Artigo em Inglês, Russo | MEDLINE | ID: mdl-36763549

RESUMO

Subarachnoid hemorrhages due to rupture of cerebral aneurysms have a high risk of disability and mortality. Screening of the population to detect aneurysms in patients with risk factors is currently not carried out in Russia. However, the detection of clinically silent aneurysms and their subsequent prophylactic surgical treatment are justified, according to numerous studies. BACKGROUND: Demonstrate the clinical and economic feasibility of screening the population (including first-line relatives) for cerebral aneurysms using an economic and mathematical model of the RF virtual population. MATERIAL AND METHODS: Mathematical modeling was carried out using an algorithm that implements a discrete Markov chain. The virtual population consisted of 145 million people (the population of the Russian Federation). Magnetic resonance angiography 3DTOF was chosen as a screening method. Virtual patients underwent preventive surgical treatment in case of detection of aneurysm during screening. The number of aneurysms in the population, the number of aneurysmal subarachnoid hemorrhage (aSAH), the cost and outcomes of treatment, and the risk of disability were calculated. RESULTS: In the case of screening and preventive surgical treatment of aneurysms, there is a decrease in the number of aSAH by 14.3% (37.5% in first-line relatives (RPLR), which affects the reduction in mortality due to aSAH by 14.4% (24.1% in The total number of disabled people is reduced by 1.5% (5.1% for the RPHR). A shift in the structure of disability towards greater labor and social adaptation of patients was noted. An economic analysis for the entire population showed that screening saves 7.7 billion annually rubles, including in the population consisting of RPLR - 4.9 billion rubles. CONCLUSION: The created mathematical model of the virtual population demonstrated that screening and prophylactic treatment of cerebral aneurysms makes it possible to reduce the number of aSAH and associated mortality among the entire population and in the RPLR group. The number of individuals with severe disabilities is decreasing. Thus, population screening for the detection of cerebral aneurysms may be clinically effective and cost-effective in the general population, especially in RPCR.


Assuntos
Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/cirurgia , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/epidemiologia , Hemorragia Subaracnóidea/cirurgia , Angiografia por Ressonância Magnética/efeitos adversos , Fatores de Risco , Federação Russa
19.
J Magn Reson Imaging ; 58(4): 1110-1122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36757267

RESUMO

BACKGROUND: Bright-blood lumen and black-blood vessel wall imaging are required for the comprehensive assessment of aortic disease. These images are usually acquired separately, resulting in long examinations and potential misregistration between images. PURPOSE: To characterize the performance of an accelerated and respiratory motion-compensated three-dimensional (3D) cardiac MRI technique for simultaneous contrast-free aortic lumen and vessel wall imaging with an interleaved T2 and inversion recovery prepared sequence (iT2Prep-BOOST). STUDY TYPE: Prospective. POPULATION: A total of 30 consecutive patients with aortopathy referred for a clinically indicated cardiac MRI examination (9 females, mean age ± standard deviation: 32 ± 12 years). FIELD STRENGTH/SEQUENCE: 1.5-T; bright-blood MR angiography (diaphragmatic navigator-gated T2-prepared 3D balanced steady-state free precession [bSSFP], T2Prep-bSSFP), breath-held black-blood two-dimensional (2D) half acquisition single-shot turbo spin echo (HASTE), and 3D bSSFP iT2Prep-BOOST. ASSESSMENT: iT2Prep-BOOST bright-blood images were compared to T2prep-bSSFP images in terms of aortic vessel dimensions, lumen-to-myocardium contrast ratio (CR), and image quality (diagnostic confidence, vessel sharpness and presence of artifacts, assessed by three cardiologists on a 4-point scale, 1: nondiagnostic to 4: excellent). The iT2Prep-BOOST black-blood images were compared to 2D HASTE images for quantification of wall thickness. A visual comparison between computed tomography (CT) and iT2Prep-BOOST was performed in a patient with chronic aortic dissection. STATISTICAL TESTS: Paired t-tests, Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), Bland-Altman analysis. A P value < 0.05 was considered statistically significant. RESULTS: Bright-blood iT2Prep-BOOST resulted in significantly improved image quality (mean ± standard deviation 3.8 ± 0.5 vs. 3.3 ± 0.8) and CR (2.9 ± 0.8 vs. 1.8 ± 0.5) compared with T2Prep-bSSFP, with a shorter scan time (7.8 ± 1.7 minutes vs. 12.9 ± 3.4 minutes) while providing a complementary 3D black-blood image. Aortic lumen diameter and vessel wall thickness measurements in bright-blood and black-blood images were in good agreement with T2Prep-bSSFP and HASTE images (<0.02 cm and <0.005 cm bias, respectively) and good intrareader (ICC > 0.96) and interreader (ICC > 0.94) agreement was observed for all measurements. DATA CONCLUSION: iT2Prep-BOOST might enable time-efficient simultaneous bright- and black-blood aortic imaging, with improved image quality compared to T2Prep-bSSFP and HASTE imaging, and comparable measurements for aortic wall and lumen dimensions. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.


Assuntos
Doenças da Aorta , Angiografia por Ressonância Magnética , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Doenças da Aorta/diagnóstico por imagem , Miocárdio , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes
20.
Int J Cardiol ; 376: 147-153, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36791965

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging allows to combine pulmonary perfusion measurements and pulmonary venous angiography during a single-session examination with both imaging modules representing the basis for accurate diagnosis and therapeutic stratification of pulmonary vein (PV) stenosis. The present study investigated the clinical utility of dynamic pulmonary perfusion imaging integrated into a comprehensive CMR protocol for the evaluation of patients with suspected PV stenosis. METHODS: 162 patients with clinically suspected PV stenosis after catheter ablation of atrial fibrillation underwent a combined single-session CMR examination (cardiac cine imaging, dynamic pulmonary perfusion, and three-dimensional PV angiography). CMR angiography was used for visual grading of PV stenoses; dynamic pulmonary perfusion imaging was evaluated per lung lobe visually and quantitatively. RESULTS: All PV stenosis ≥90% showed a visible perfusion deficit of the corresponding lung lobe (60/60, 100%) while all PVs with luminal narrowing <50% exhibited normal pulmonary perfusion (680/680, 100%). However, every third 70-89% stenosis showed a normal pulmonary perfusion (10/31, 32%) while every fourth 50-69% PV stenosis was associated with hypoperfusion of the corresponding lung lobe (9/39, 23%). For quantitative pulmonary perfusion measurements, ROC analysis demonstrated high discriminatory power regarding PV stenosis detection with the highest AUC values for time-to-peak enhancement (cut-off value, 8.5 s). CONCLUSIONS: The combination of CMR angiography and CMR pulmonary perfusion allowed for assessment of the anatomical degree of PV stenosis and its hemodynamic impact on the pulmonary parenchymal level. Thus, the proposed comprehensive CMR protocol provided an efficient diagnostic work-up of patients with suspected PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Constrição Patológica , Veias Pulmonares/cirurgia , Angiografia por Ressonância Magnética/métodos , Pulmão , Perfusão , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA