Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 671
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 13(13): e035171, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38904248

RESUMO

BACKGROUND: Cervical arterial tortuosity is associated with adverse outcomes in Loeys-Dietz syndrome and other heritable aortopathies. METHODS AND RESULTS: A method to assess tortuosity based on curvature of the vessel centerline in 3-dimensional space was developed. We measured cervical carotid tortuosity in 65 patients with Loeys-Dietz syndrome from baseline computed tomography angiogram/magnetic resonance angiogram and all serial images during follow-up. Relations between baseline carotid tortuosity, age, aortic root diameter, and its change over time were compared. Patients with unoperated aortic roots were assessed for clinical end point (type A aortic dissection or aortic root surgery during 4 years of follow-up). Logistic regression was performed to assess the likelihood of clinical end point according to baseline carotid tortuosity. Total absolute curvature at baseline was 11.13±5.76 and was relatively unchanged at 8 to 10 years (fold change: 0.026±0.298, P=1.00), whereas tortuosity index at baseline was 0.262±0.131, with greater variability at 8 to 10 years (fold change: 0.302±0.656, P=0.818). Baseline total absolute curvature correlated with aortic root diameter (r=0.456, P=0.004) and was independently associated with aortic events during the 4-year follow-up (adjusted odds ratio [OR], 2.64 [95% CI, 1.02-6.85]). Baseline tortuosity index correlated with age (r=0.532, P<0.001) and was not associated with events (adjusted OR, 1.88 [95% CI, 0.79-4.51]). Finally, baseline total absolute curvature had good discrimination of 4-year outcomes (area under the curve=0.724, P=0.014), which may be prognostic or predictive. CONCLUSIONS: Here we introduce cervical carotid tortuosity as a promising quantitative biomarker with validated, standardized characteristics. Specifically, we recommend the adoption of a curvature-based measure, total absolute curvature, for early detection or monitoring of disease progression in Loeys-Dietz syndrome.


Assuntos
Artérias Carótidas , Angiografia por Tomografia Computadorizada , Síndrome de Loeys-Dietz , Angiografia por Ressonância Magnética , Humanos , Feminino , Masculino , Medição de Risco , Adulto , Síndrome de Loeys-Dietz/genética , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/diagnóstico por imagem , Pessoa de Meia-Idade , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Fatores de Risco , Adulto Jovem , Valor Preditivo dos Testes , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/diagnóstico , Imageamento Tridimensional , Reprodutibilidade dos Testes , Dermatopatias Genéticas/genética , Dermatopatias Genéticas/diagnóstico por imagem , Dermatopatias Genéticas/diagnóstico
2.
Turk Kardiyol Dern Ars ; 52(4): 284-289, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38829638

RESUMO

Coronary computed tomography angiography (CCTA) and CT-derived fractional flow reserve (FFRCT) provide high diagnostic accuracy for coronary artery disease (CAD), consistent with invasive coronary angiography (ICA), the gold standard diagnostic technique. The presence of calcified components, however, complicates the interpretation of coronary stenosis severity. We present a case where there was a discrepant assessment of coronary stenosis severity between CCTA/FFRCT (indicating significant obstructive CAD) and ICA (showing no apparent obstructive CAD). CCTA/FFRCT revealed that the stenotic lesion, located in the middle segment of the left circumflex artery, was surrounded by plaque components. The proximal and distal portions of the stenotic lesion consisted of 80.9% luminal volume, 0.2% low-attenuation plaque, 13.4% intermediate-attenuation plaque, and 5.5% calcified plaque. In contrast, the stenotic lesion itself contained 50.0% luminal volume, 0.3% low-attenuation plaque, 26.7% intermediate-attenuation plaque, and 22.9% calcified plaque. Invasive coronary angiography showed no apparent obstructive CAD, implying that the lesions appearing as significant obstructive CAD on CCTA/FFRCT were likely overestimated due to the effects of extravascular calcified plaque. Advanced extravascular calcified plaque surrounding the lesion may cause several artifacts (such as blooming and/or beam hardening artifacts) and/or vasodilator dysfunction (either organic and/or functional), potentially leading to an overestimation of the severity of coronary stenosis in CCTA/FFRCT assessments.


Assuntos
Angiografia Coronária , Estenose Coronária , Índice de Gravidade de Doença , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Masculino , Placa Aterosclerótica/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia por Tomografia Computadorizada , Pessoa de Meia-Idade
3.
PLoS One ; 19(6): e0305189, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38870138

RESUMO

OBJECTIVES: The aim of this early-stage Health Technology Assessment (HTA) was to assess the difference in healthcare costs and effects of fractional flow reserve derived from coronary computed tomography (FFRct) compared to standard diagnostics in patients with stable chest pain in The Netherlands. METHODS: A decision-tree model was developed to assess the difference in total costs from the hospital perspective, probability of correct diagnoses, and risk of major adverse cardiovascular events at one year follow-up. One-way sensitivity analyses were conducted to determine the main drivers of the cost difference between the strategies. A threshold analysis on the added price of FFRct analysis (computational analysis only) was conducted. RESULTS: The mean one-year costs were €2,680 per patient for FFRct and €2,915 per patient for standard diagnostics. The one-year probability of correct diagnoses was 0.78 and 0.61, and the probability of major adverse cardiovascular events was 1.92x10-5 and 0.01, respectively. The probability and costs of revascularization and the specificity of coronary computed tomography angiography had the greatest effect on the difference in costs between the strategies. The added price of FFRct analysis should be below €935 per patient to be considered the least costly option. CONCLUSIONS: The early-stage HTA findings suggest that FFRct may reduce total healthcare spending, probability of incorrect diagnoses, and major adverse cardiovascular events compared to current diagnostics for patients with stable chest pain in the Dutch healthcare setting over one year. Future cost-effectiveness studies should determine a value-based pricing for FFRct and quantify the economic value of the anticipated therapeutic impact.


Assuntos
Dor no Peito , Reserva Fracionada de Fluxo Miocárdico , Avaliação da Tecnologia Biomédica , Humanos , Países Baixos , Dor no Peito/diagnóstico por imagem , Dor no Peito/diagnóstico , Feminino , Masculino , Angiografia por Tomografia Computadorizada/economia , Angiografia por Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Angiografia Coronária/economia , Angiografia Coronária/métodos , Custos de Cuidados de Saúde , Análise Custo-Benefício , Tomografia Computadorizada por Raios X/economia , Tomografia Computadorizada por Raios X/métodos , Idoso , Árvores de Decisões
4.
Radiol Med ; 129(7): 999-1007, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38935247

RESUMO

PURPOSE: To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. MATERIAL AND METHODS: 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. RESULTS: VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p < 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. CONCLUSION: Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Idoso , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
Int J Cardiovasc Imaging ; 40(7): 1493-1500, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38748056

RESUMO

Image noise and vascular attenuation are important factors affecting image quality and diagnostic accuracy of coronary computed tomography angiography (CCTA). The aim of this study was to develop an algorithm that automatically performs noise and attenuation measurements in CCTA and to evaluate the ability of the algorithm to identify non-diagnostic examinations. The algorithm, "NoiseNet", was trained and tested on 244 CCTA studies from the Swedish CArdioPulmonary BioImage Study. The model is a 3D U-Net that automatically segments the aortic root and measures attenuation (Hounsfield Units, HU), noise (standard deviation of HU, HUsd) and signal-to-noise ratio (SNR, HU/HUsd) in the aortic lumen, close to the left coronary ostium. NoiseNet was then applied to 529 CCTA studies previously categorized into three subgroups: fully diagnostic, diagnostic with excluded parts and non-diagnostic. There was excellent correlation between NoiseNet and manual measurements of noise (r = 0.948; p < 0.001) and SNR (r = 0.948; <0.001). There was a significant difference in noise levels between the image quality subgroups: fully diagnostic 33.1 (29.8-37.9); diagnostic with excluded parts 36.1 (31.5-40.3) and non-diagnostic 42.1 (35.2-47.7; p < 0.001). Corresponding values for SNR were 16.1 (14.0-18.0); 14.0 (12.4-16.2) and 11.1 (9.6-14.0; p < 0.001). ROC analysis for prediction of a non-diagnostic study showed an AUC for noise of 0.73 (CI 0.64-0.83) and for SNR of 0.80 (CI 0.71-0.89). In conclusion, NoiseNet can perform noise and SNR measurements with high accuracy. Noise and SNR impact image quality and automatic measurements may be used to identify CCTA studies with low image quality.


Assuntos
Algoritmos , Automação , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído , Humanos , Angiografia Coronária/métodos , Reprodutibilidade dos Testes , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Suécia , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Feminino , Artefatos , Masculino , Idoso
7.
Am J Emerg Med ; 82: 33-36, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38772156

RESUMO

BACKGROUND: Routine evaluation with CTA for patients with isolated lower extremity penetrating trauma and normal ankle-brachial-indices (ABI) remains controversial. While prior literature has found normal ABI's (≥0.9) and a normal clinical examination to be adequate for safe discharge, there remains concern for missed injuries which could lead to delayed surgical intervention and unnecessary morbidity. Our hypothesis was that routine CTA after isolated lower extremity penetrating trauma with normal ABIs and clinical examination is not cost-effective. METHODS: We performed a decision-analytic model to evaluate the cost-effectiveness of obtaining a CTA routinely compared to clinical observation and ABI evaluation in hemodynamically normal patients with isolated penetrating lower extremity trauma. Our base case was a patient that sustained penetrating lower extremity trauma with normal ABIs that received a CTA in the trauma bay. Costs, probability, and Quality-Adjusted Life Years (QALYs) were generated from published literature. RESULTS: Clinical evaluation only (no CTA) was cost-effective with a cost of $2056.13 and 0.98 QALYs gained compared to routine CTA which had increased costs of $7449.91 and lower QALYs 0.92. Using one-way sensitivity analysis, routine CTA does not become the cost-effective strategy until the cost of a missed injury reaches $210,075.83. CONCLUSIONS: Patients with isolated, penetrating lower extremity trauma with normal ABIs and clinical examination do not warrant routine CTA as there is no benefit with increased costs.


Assuntos
Angiografia por Tomografia Computadorizada , Análise Custo-Benefício , Anos de Vida Ajustados por Qualidade de Vida , Ferimentos Penetrantes , Humanos , Angiografia por Tomografia Computadorizada/economia , Angiografia por Tomografia Computadorizada/métodos , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/economia , Extremidade Inferior/lesões , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Índice Tornozelo-Braço , Traumatismos da Perna/diagnóstico por imagem , Traumatismos da Perna/economia , Técnicas de Apoio para a Decisão , Masculino , Análise de Custo-Efetividade
8.
Korean J Radiol ; 25(6): 518-539, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38807334

RESUMO

Coronary computed tomography angiography (CCTA) has emerged as a pivotal tool for diagnosing and risk-stratifying patients with suspected coronary artery disease (CAD). Recent advancements in image analysis and artificial intelligence (AI) techniques have enabled the comprehensive quantitative analysis of coronary atherosclerosis. Fully quantitative assessments of coronary stenosis and lumen attenuation have improved the accuracy of assessing stenosis severity and predicting hemodynamically significant lesions. In addition to stenosis evaluation, quantitative plaque analysis plays a crucial role in predicting and monitoring CAD progression. Studies have demonstrated that the quantitative assessment of plaque subtypes based on CT attenuation provides a nuanced understanding of plaque characteristics and their association with cardiovascular events. Quantitative analysis of serial CCTA scans offers a unique perspective on the impact of medical therapies on plaque modification. However, challenges such as time-intensive analyses and variability in software platforms still need to be addressed for broader clinical implementation. The paradigm of CCTA has shifted towards comprehensive quantitative plaque analysis facilitated by technological advancements. As these methods continue to evolve, their integration into routine clinical practice has the potential to enhance risk assessment and guide individualized patient management. This article reviews the evolving landscape of quantitative plaque analysis in CCTA and explores its applications and limitations.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Estenose Coronária/diagnóstico por imagem
9.
Rev Med Suisse ; 20(875): 1020-1025, 2024 May 22.
Artigo em Francês | MEDLINE | ID: mdl-38783671

RESUMO

Coronary Computed Tomography Angiography (CCTA) has now become an established tool in the diagnostic process for patients suspected of coronary artery disease. In light of rapid technological development, CCTA has evolved into an imaging modality providing both anatomical and functional information to guide patient management. In this article, we describe the role of cardiac CT in assessing atherosclerotic plaque, chest pain evaluation, cardiovascular risk stratification, planning and guiding coronary intervention, as well as structural heart diseases.


Le scanner coronarien est actuellement un outil reconnu dans le processus diagnostique des patients chez qui on suspecte une maladie coronarienne. Bénéficiant d'un développement technologique rapide et procurant des informations tant morphologiques que fonctionnelles, le CT cardiaque devient une modalité d'imagerie incontournable pour orienter la prise en charge des patients. Dans cet article, nous décrivons le rôle du CT cardiaque dans l'évaluation de la plaque d'athérosclérose, des douleurs thoraciques, de la stratification du risque cardiovasculaire, de la planification et du guidage de l'intervention coronarienne, ainsi que des maladies cardiaques structurelles.


Assuntos
Dor no Peito , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Dor no Peito/etiologia , Dor no Peito/diagnóstico por imagem , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico , Medição de Risco/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/diagnóstico
10.
Am J Manag Care ; 30(6 Spec No.): SP473-SP477, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38820190

RESUMO

OBJECTIVES: In 2018, CMS established reimbursement for the first Medicare-covered artificial intelligence (AI)-enabled clinical software: CT fractional flow reserve (FFRCT) to assist in the diagnosis of coronary artery disease. This study quantified Medicare utilization of and spending on FFRCT from 2018 through 2022 and characterized adopting hospitals, clinicians, and patients. STUDY DESIGN: Analysis, using 100% Medicare fee-for-service claims data, of the hospitals, clinicians, and patients who performed or received coronary CT angiography with or without FFRCT. METHODS: We measured annual trends in utilization of and spending on FFRCT among hospitals and clinicians from 2018 through 2022. Characteristics of FFRCT-adopting and nonadopting hospitals and clinicians were compared, as well as the characteristics of patients who received FFRCT vs those who did not. RESULTS: From 2018 to 2022, FFRCT billing volume in Medicare increased more than 11-fold (from 1083 to 12,363 claims). Compared with nonbilling hospitals, FFRCT-billing hospitals were more likely to be larger, part of a health system, nonprofit, and financially profitable. FFRCT-billing clinicians worked in larger group practices and were more likely to be cardiac specialists. FFRCT-receiving patients were more likely to be male and White and less likely to be dually enrolled in Medicaid or receiving disability benefits. CONCLUSIONS: In the initial 5 years of Medicare reimbursement for FFRCT, growth was concentrated among well-resourced hospitals and clinicians. As Medicare begins to reimburse clinicians for the use of AI-enabled clinical software such as FFRCT, it is crucial to monitor the diffusion of these services to ensure equal access.


Assuntos
Inteligência Artificial , Doença da Artéria Coronariana , Medicare , Estados Unidos , Humanos , Medicare/economia , Medicare/estatística & dados numéricos , Masculino , Feminino , Idoso , Doença da Artéria Coronariana/economia , Reserva Fracionada de Fluxo Miocárdico , Planos de Pagamento por Serviço Prestado/estatística & dados numéricos , Angiografia por Tomografia Computadorizada/economia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Software , Angiografia Coronária/estatística & dados numéricos , Angiografia Coronária/economia
12.
Int J Cardiol ; 407: 132015, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38609053

RESUMO

BACKGROUND: Guidelines recommend standard pre-operative cardiac screening in all liver transplantation (LT) recipients, despite the relatively low prevalence of obstructive coronary artery disease. Most LT recipients often have non-gated computed tomography (CT) performed of the chest and abdomen. This study evaluated the ability of coronary artery calcification (CAC) assessment on consecutively available scans, to identify a selection of low-risk patients, in whom further cardiac imaging can be safely withheld. METHODS: LT recipients with prior non-gated CT chest-abdomen were included. CAC was visually scored on a semi-quantitative ordinal scale. Stress myocardial perfusion, coronary CT angiography (CCTA) and invasive coronary angiography (ICA) were used as golden standard. The sensitivity and specificity of CAC to exclude and predict obstructive CAD were assessed. In addition, peri- and postoperative mortality and cardiac events were analyzed. RESULTS: 149 LT recipients (ranged 31-71 years) were included. In 75% of patients, no CAC and mild CAC could rule out obstructive CAD on CCTA and ICA with 100% certainty. The threshold of mild CAC had a sensitivity of 100% for both CCTA and ICA and a specificity of 91% and 68%, respectively. None of the patients with no or mild calcifications experienced peri- and post-operative cardiac events or died of cardiac causes. CONCLUSION: Visual evaluation of CAC on prior non-gated CT can accurately and safely exclude obstructive CAD in LT recipients. Incorporation of these already available data can optimize cardiac screening, by safely withholding or correctly allocating dedicated cardiac imaging in LT recipients. Thereby, reducing patients' test burden and save health care expenses.


Assuntos
Doença da Artéria Coronariana , Transplante de Fígado , Cuidados Pré-Operatórios , Calcificação Vascular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Calcificação Vascular/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/normas , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Estudos Retrospectivos
13.
Phys Med ; 121: 103365, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38663347

RESUMO

PURPOSE: To establish size-specific diagnostic reference levels (DRLs) for pulmonary embolism (PE) based on patient CT examinations performed on 74 CT devices. To assess task-based image quality (IQ) for each device and to investigate the variability of dose and IQ across different CTs. To propose a dose/IQ optimization. METHODS: 1051 CT pulmonary angiography dose data were collected. DRLs were calculated as the 75th percentile of CT dose index (CTDI) for two patient categories based on the thoracic perimeters. IQ was assessed with two thoracic phantom sizes using local acquisition parameters and three other dose levels. The area under the ROC curve (AUC) of a 2 mm low perfused vessel was assessed with a non-prewhitening with eye-filter model observer. The optimal IQ-dose point was mathematically assessed from the relationship between IQ and dose. RESULTS: The DRLs of CTDIvol were 6.4 mGy and 10 mGy for the two patient categories. 75th percentiles of phantom CTDIvol were 6.3 mGy and 10 mGy for the two phantom sizes with inter-quartile AUC values of 0.047 and 0.066, respectively. After the optimization, 75th percentiles of phantom CTDIvol decreased to 5.9 mGy and 7.55 mGy and the interquartile AUC values were reduced to 0.025 and 0.057 for the two phantom sizes. CONCLUSION: DRLs for PE were proposed as a function of patient thoracic perimeters. This study highlights the variability in terms of dose and IQ. An optimization process can be started individually and lead to a harmonization of practice throughout multiple CT sites.


Assuntos
Angiografia por Tomografia Computadorizada , Imagens de Fantasmas , Embolia Pulmonar , Embolia Pulmonar/diagnóstico por imagem , Humanos , Doses de Radiação , Níveis de Referência de Diagnóstico , Masculino , Processamento de Imagem Assistida por Computador/métodos , Feminino , Controle de Qualidade , Idoso , Pessoa de Meia-Idade
14.
Int J Cardiovasc Imaging ; 40(6): 1201-1209, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38630211

RESUMO

This study assesses the agreement of Artificial Intelligence-Quantitative Computed Tomography (AI-QCT) with qualitative approaches to atherosclerotic disease burden codified in the multisociety 2022 CAD-RADS 2.0 Expert Consensus. 105 patients who underwent cardiac computed tomography angiography (CCTA) for chest pain were evaluated by a blinded core laboratory through FDA-cleared software (Cleerly, Denver, CO) that performs AI-QCT through artificial intelligence, analyzing factors such as % stenosis, plaque volume, and plaque composition. AI-QCT plaque volume was then staged by recently validated prognostic thresholds, and compared with CAD-RADS 2.0 clinical methods of plaque evaluation (segment involvement score (SIS), coronary artery calcium score (CACS), visual assessment, and CAD-RADS percent (%) stenosis) by expert consensus blinded to the AI-QCT core lab reads. Average age of subjects were 59 ± 11 years; 44% women, with 50% of patients at CAD-RADS 1-2 and 21% at CAD-RADS 3 and above by expert consensus. AI-QCT quantitative plaque burden staging had excellent agreement of 93% (k = 0.87 95% CI: 0.79-0.96) with SIS. There was moderate agreement between AI-QCT quantitative plaque volume and categories of visual assessment (64.4%; k = 0.488 [0.38-0.60]), and CACS (66.3%; k = 0.488 [0.36-0.61]). Agreement between AI-QCT plaque volume stage and CAD-RADS % stenosis category was also moderate. There was discordance at small plaque volumes. With ongoing validation, these results demonstrate a potential for AI-QCT as a rapid, reproducible approach to quantify total plaque burden.


Assuntos
Inteligência Artificial , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Estenose Coronária , Placa Aterosclerótica , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Calcificação Vascular , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Idoso , Reprodutibilidade dos Testes , Calcificação Vascular/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada Multidetectores , Variações Dependentes do Observador
15.
Liver Int ; 44(8): 1912-1923, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38591767

RESUMO

BACKGROUND: The optimal cardiovascular assessment of liver transplant (LT) candidates is unclear. We aimed to evaluate the performance of CT-based coronary tests (coronary artery calcium score [CACS] and coronary CT angiography [CCTA]) and a modification of the CAD-LT score (mCAD-LT, excluding family history of CAD) to diagnose significant coronary artery disease (CAD) before LT and predict the incidence of post-LT cardiovascular events (CVE). METHODS: We retrospectively analysed a single-centre cohort of LT candidates who underwent non-invasive tests; invasive coronary angiography (ICA) was performed depending on the results of non-invasive tests. mCAD-LT was calculated in all patients. RESULTS: Six-hundred-and-thirty-four LT candidates were assessed and 351 of them underwent LT. CACS, CCTA and ICA were performed in 245, 123 and 120 LT candidates, respectively. Significant CAD was found in 30% of patients undergoing ICA. The AUROCs of mCAD-LT (.722) and CCTA (.654) were significantly higher than that of CACS (.502) to predict the presence of significant CAD. Specificity of the tests ranged between 31% for CCTA and 53% for CACS. Among patients who underwent LT, CACS ≥ 400 and mCAD-LT were independently associated with the incidence of CVE; in patients who underwent CCTA before LT, significant CAD at CCTA also predicted post-LT CVE. CONCLUSION: In this cohort, mCAD-LT score and CT-based tests detect the presence of significant CAD in LT candidates, although they tend to overestimate it. Both mCAD-LT score and CT-based tests classify LT recipients according to their risk of post-LT CVE and can be used to improve post-LT risk mitigation.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Transplante de Fígado , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Transplante de Fígado/efeitos adversos , Medição de Risco , Idoso , Valor Preditivo dos Testes , Calcificação Vascular/diagnóstico por imagem , Adulto , Fatores de Risco
16.
J Cardiovasc Comput Tomogr ; 18(3): 291-296, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38462389

RESUMO

BACKGROUND: Computed tomography cardiac angiography (CTCA) is recommended for the evaluation of patients with prior coronary artery bypass graft (CABG) surgery. The BYPASS-CTCA study demonstrated that CTCA prior to invasive coronary angiography (ICA) in CABG patients leads to significant reductions in procedure time and contrast-induced nephropathy (CIN), alongside improved patient satisfaction. However, whether CTCA information was used to facilitate selective graft cannulation at ICA was not protocol mandated. In this post-hoc analysis we investigated the influence of CTCA facilitated selective graft assessment on angiographic parameters and study endpoints. METHODS: BYPASS-CTCA was a randomized controlled trial in which patients with previous CABG referred for ICA were randomized to undergo CTCA prior to ICA, or ICA alone. In this post-hoc analysis we assessed the impact of selective ICA (grafts not invasively cannulated based on the CTCA result) following CTCA versus non-selective ICA (imaging all grafts irrespective of CTCA findings). The primary endpoints were ICA procedural duration, incidence of CIN, and patient satisfaction post-ICA. Secondary endpoints included the incidence of procedural complications and 1-year major adverse cardiac events. RESULTS: In the CTCA cohort (n â€‹= â€‹343), 214 (62.4%) patients had selective coronary angiography performed, whereas 129 (37.6%) patients had non-selective ICA. Procedure times were significantly reduced in the selective CTCA â€‹+ â€‹ICA group compared to the non-selective CTCA â€‹+ â€‹ICA group (-5.82min, 95% CI -7.99 to -3.65, p â€‹< â€‹0.001) along with reduction of CIN (1.5% vs 5.8%, OR 0.26, 95% CI 0.10 to 0.98). No difference was seen in patient satisfaction with the ICA, however procedural complications (0.9% vs 4.7%, OR 0.21, 95% CI 0.09-0.87) and 1-year major adverse cardiac events (13.1% vs 20.9%, HR 0.55, 95% CI 0.32-0.96) were significantly lower in the selective group. CONCLUSIONS: In patients with prior CABG, CTCA guided selective angiographic assessment of bypass grafts is associated with improved procedural parameters, lower complication rates and better 12-month outcomes. Taken in addition to the main findings of the BYPASS-CTCA trial, these results suggest a synergistic approach between CTCA and ICA should be considered in this patient group. REGISTRATION: ClinicalTrials.gov, NCT03736018.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Doença da Artéria Coronariana , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos , Fatores de Tempo , Fatores de Risco , Satisfação do Paciente , Vasos Coronários/diagnóstico por imagem , Nefropatias/diagnóstico por imagem , Duração da Cirurgia , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos
18.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451189

RESUMO

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Angiografia por Tomografia Computadorizada , Endoleak , Idoso , Humanos , Masculino , Aorta , Endoleak/diagnóstico por imagem , Fenômenos Físicos , Estudos Prospectivos , Feminino
19.
J Cardiovasc Comput Tomogr ; 18(3): 297-303, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38514283

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) is used to evaluate components of atherosclerosis. Either adaptive or diverse, fixed Hounsfield Units (HU) are used to define components such as low attenuation (LAP), mixed (MP) and calcified plaque (CP). Comparisons of different platforms and different thresholding approaches have not been extensively evaluated. We compare two fixed threshold options to an adaptive threshold option within a specific platform and to fixed threshold options measured with another platform. METHODS: Coronary segments (n â€‹= â€‹24) of good image quality, with well-defined boundaries and representing a broad range of atheroma were analyzed for LAP, MP and CP. Thresholds for LAP vs MP and MP vs CP were either Fixed30/350, Fixed75/350 or based on an automatically determined Adaptive option. Pearson correlation and Bland-Altman analyses were undertaken. RESULTS: Within a single platform, measures were highly correlated irrespective of use of Adaptive or Fixed30/350 and Fixed75/350 thresholds (R â€‹≥ â€‹0.819, p â€‹< â€‹0.000001). The correlation slope for measures of LAP progressively diminished comparing the Adaptive versus Fixed30/350 and the Fixed75/350 versus the Fixed30/350 approaches but bias was small. Between-platform comparisons yielded less optimal results, particularly with respect to measures of LAP and with one platform yielding both very small LAP volumes and very small ranges of volumes. CONCLUSION: Measures of plaque components are highly correlated irrespective of use of Adaptive or Fixed threshold approaches within a given platform. But measures are more affected by the specific proprietary algorithms employed than by specific thresholding options, especially for LAP.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Placa Aterosclerótica , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Calcificação Vascular , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Reprodutibilidade dos Testes , Masculino , Feminino , Índice de Gravidade de Doença , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada Multidetectores
20.
J Vasc Res ; 61(3): 122-128, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38547846

RESUMO

INTRODUCTION: We aimed to compare conventional vessel wall MR imaging techniques and quantitative susceptibility mapping (QSM) to determine the optimal sequence for detecting carotid artery calcification. METHODS: Twenty-two patients who underwent carotid vessel wall MR imaging and neck CT were enrolled. Four slices of 6-mm sections from the bilateral internal carotid bifurcation were subdivided into 4 segments according to clock position (0-3, 3-6, 6-9, and 9-12) and assessed for calcification. Two blinded radiologists independently reviewed a total of 704 segments and scored the likelihood of calcification using a 5-point scale on spin-echo imaging, FLASH, and QSM. The observer performance for detecting calcification was evaluated by a multireader, multiple-case receiver operating characteristic study. Weighted κ statistics were calculated to assess interobserver agreement. RESULTS: QSM had a mean area under the receiver operating characteristic curve of 0.85, which was significantly higher than that of any other sequence (p < 0.01) and showed substantial interreader agreement (κ = 0.68). A segment with a score of 3-5 was defined as positive, and a segment with a score of 1-2 was defined as negative; the sensitivity and specificity of QSM were 0.75 and 0.87, respectively. CONCLUSION: QSM was the most reliable MR sequence for the detection of plaque calcification.


Assuntos
Doenças das Artérias Carótidas , Variações Dependentes do Observador , Placa Aterosclerótica , Valor Preditivo dos Testes , Calcificação Vascular , Humanos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/patologia , Reprodutibilidade dos Testes , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/patologia , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA