Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Pediatr ; 183(8): 3159-3171, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38831134

RESUMO

Torsional disorders of the lower limb are common in childhood, and they are one of the primary reasons parents seek consultation with healthcare providers. While clinical manoeuvres can assess femoral and tibial torsion, their reliability is medium to low. Various imaging-based techniques, including computed tomography, magnetic resonance imaging, fluoroscopy, biplanar radiology and ultrasonography, have been used to evaluate torsional alterations of the lower extremity. Among these, ultrasound assessment offers certain advantages: it is a low-cost, non-irradiating technique, which allows the follow-up of children's torsional development. However, to the best of the authors' knowledge, its validity and reliability have not been summarised in a systematic review. This study aims to analyse the validity and reliability of ultrasonography in determining femoral and tibial torsion in children and adolescents. A search from Medline (via PubMed), Web of Science, Scopus and CINAHL databases were performed from inception to 16 March 2023. No restrictions were placed on the publication year or language. The methodological quality of all eligible studies was independently reviewed by two authors using QUADAS and STARD checklists. Overall, 1546 articles were identified through the searches; 30 were considered eligible for full-text screening; and 8 studies were finally included in this review. The included studies were conducted in Germany, Norway and the UK. Among them, 7 studies analysed the validity of ultrasonography compared with other imaging techniques such as computed tomography, magnetic resonance imaging and biplanar X-ray, and 4 studies assessed intra- and inter-observer reliability. All the studies assessed femoral torsion, but only one of them also included tibial torsion.     Conclusion: Ultrasound is a good alternative for routine evaluation and follow-up of femoral torsional alterations in children and adolescents due to its safety, accessibility and immediate results in the clinical examination room. Although ultrasound has good accuracy and reliability for routine evaluations, there is controversy about whether it is sufficient for surgical planning. In cases where greater accuracy is required, magnetic resonance imaging and biplanar radiography are the preferred imaging techniques. What is Known: • Several imaging-based techniques have been described for the assessment of torsional alterations of the lower extremity. • Computed tomography, magnetic resonance imaging, biplanar radiology and ultrasonography are the most used and studied methods. What is New: • Ultrasonography represents a good alternative for the assessment of femoral and tibial torsional alterations in children and adolescents, given its safety, accessibility and immediacy of results in the consultation room. • Its accuracy and reliability are good but not sufficient for surgical planning, in which case MRI and biplanar X-ray will be the preferred choices.


Assuntos
Fêmur , Tíbia , Anormalidade Torcional , Ultrassonografia , Adolescente , Criança , Humanos , Fêmur/diagnóstico por imagem , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Ultrassonografia/métodos
2.
Eur J Trauma Emerg Surg ; 48(4): 3229-3235, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35146543

RESUMO

BACKGROUND: Tibial torsional malalignment presents a well-known complication of intramedullary nailing for tibial shaft fractures. PURPOSE: Objective of this study was to investigate the ability to clinically assess tibial torsion differences. Computed Tomography (CT) was used here as the gold standard. Further, intra- and inter-observer reliability of the clinical examination, and radiological measurements were calculated. METHODS: Fifty-one patients with torsion-difference CTs, obtained for various reasons, were asked to kneel on an examination couch with free hanging feet. All patients are positioned with 90° flexed knee and neutral ankle. A picture of the lower extremities was obtained from the back of the patient. Two blinded orthopedic surgeons were asked to look at the pictures and measure the tibial torsion with a digital goniometer, based on the axis of the femur in relation to the second ray of the foot. To determine the intra-observer variation, the torsional angles were calculated again after 4 weeks. To be able to compare values, two blinded radiologists calculated torsional differences based on computed tomography. RESULTS: All patients were able to be positioned for clinical assessment (n = 51). Clinical assessment of torsional difference revealed 4.55° ± 6.85 for the first, respectively, 4.55° ± 7.41 for the second investigator. The second measurement of the first investigator revealed a value of 4.57° ± 6.9. There was a good intra-observer agreement for clinical assessment (ICC 0.993, p < 0.001). Also, the inter-observer agreement showed a good inter-observer agreement (ICC 0.949, p < 0.001). Evaluation of radiological inter-observer assessment could also show a good inter-observer agreement (ICC 0.922, p < 0.001). The clinical method showed a good correlation to the CT method (0.839, p < 0.001). Additionally, the Bland-Altman plot was used to compare graphically both measurement techniques, which proved the agreement. CONCLUSION: In summary, computed tomography-assisted measurement of tibial torsion and clinical assessment correlated significantly good. In addition to that, clinical measurement has a good intra- and inter-observer reliability. Clinical examination is a reliable and cost-effective tool to detect mal-torsion and should be part of the repertoire of every surgeon.


Assuntos
Fraturas da Tíbia , Tomografia Computadorizada por Raios X , Fêmur/cirurgia , Humanos , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia
3.
Sci Rep ; 11(1): 23244, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34853401

RESUMO

Abnormal torsion of the lower limbs may adversely affect joint health. This study developed and validated a deep learning-based method for automatic measurement of femoral and tibial torsion on MRI. Axial T2-weighted sequences acquired of the hips, knees, and ankles of 93 patients (mean age, 13 ± 5 years; 52 males) were included and allocated to training (n = 60), validation (n = 9), and test sets (n = 24). A U-net convolutional neural network was trained to segment both femur and tibia, identify osseous anatomic landmarks, define pertinent reference lines, and quantify femoral and tibial torsion. Manual measurements by two radiologists provided the reference standard. Inter-reader comparisons were performed using repeated-measures ANOVA, Pearson's r, and the intraclass correlation coefficient (ICC). Mean Sørensen-Dice coefficients for segmentation accuracy ranged between 0.89 and 0.93 and erroneous segmentations were scarce. Ranges of torsion as measured by both readers and the algorithm on the same axial image were 15.8°-18.0° (femur) and 33.9°-35.2° (tibia). Correlation coefficients (ranges, .968 ≤ r ≤ .984 [femur]; .867 ≤ r ≤ .904 [tibia]) and ICCs (ranges, .963 ≤ ICC ≤ .974 [femur]; .867 ≤ ICC ≤ .894 [tibia]) indicated excellent inter-reader agreement. Algorithm-based analysis was faster than manual analysis (7 vs 207 vs 230 s, p < .001). In conclusion, fully automatic measurement of torsional alignment is accurate, reliable, and sufficiently fast for clinical workflows.


Assuntos
Inteligência Artificial , Deformidades Congênitas das Extremidades Inferiores/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Anormalidade Torcional/diagnóstico por imagem , Adolescente , Adulto , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Redes Neurais de Computação
4.
Kyobu Geka ; 74(3): 191-195, 2021 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-33831871

RESUMO

The incidence of postoperative pulmonary torsion is not frequent but it has a high mortality rate once it occurs, and prompt diagnosis and treatment are required. From past reports, it is considered effective to point out disruption of pulmonary blood flow by contrast-enhanced computed tomography (CT) examination for diagnosis. However, the comparison of pre- and post-operative plain CT images is considered to be useful in diagnosing lung torsion, and postoperative CT lung window setting sagittal images were examined in three cases of postoperative lung torsion. Results indicate that pulmonary torsion of the middle lobe after right lower lobectomy and the middle lobe after right upper lobectomy can be diagnosed by the present method.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Diagnóstico Precoce , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Pneumopatias/diagnóstico por imagem , Pneumopatias/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Pneumonectomia , Tomografia Computadorizada por Raios X , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia
5.
Abdom Radiol (NY) ; 46(3): 1137-1147, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32935259

RESUMO

PURPOSE: To define and weight the preoperative CT findings for ovarian torsion and to develop an integrated nomogram for estimating the probability of ovarian torsion in women with ovarian lesion and pelvic pain. METHODS: This retrospective study included 218 women with surgically resected ovarian lesions who underwent preoperative contrast-enhanced CT for pelvic pain from January 2014 to February 2019. Significant imaging findings for torsion were extracted using regression analyses and a regression coefficient-based nomogram was constructed. The diagnostic performance with sensitivity, specificity, and accuracy of the significant imaging findings and the nomogram were assessed. RESULTS: A total of 255 ovarian lesions (123 lesions with torsion and 132 lesions without torsion) were evaluated. Multivariable regression analysis showed that whirl sign (odds ratio [OR] 11.000; p < 0.001), tubal thickening (OR 4.621; p = 0.001), unusual location of ovarian lesion (OR 2.712; p = 0.020), and hemorrhagic component within adnexal lesion (OR 2.537; p = 0.028) were independent significant parameters predicting ovarian torsion. Tubal thickening showed the highest sensitivity (91.1%) and whirl sign showed the highest specificity (94.7%). When probabilities of ovarian torsion of 0.5 or more in the nomogram were diagnosed as ovarian torsion, sensitivity, specificity, and accuracy of the nomogram were 78.1%, 91.7%, and 85.1%, respectively. CONCLUSION: The whirl sign, tubal thickening, unusual location of ovarian lesion, and hemorrhagic component within adnexal lesion, and an integrated nomogram derived from these significant findings can be useful for predicting ovarian torsion.


Assuntos
Doenças dos Anexos , Cistos Ovarianos , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/diagnóstico por imagem , Torção Ovariana , Dor Pélvica/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Anormalidade Torcional/diagnóstico por imagem
6.
Vet Radiol Ultrasound ; 62(2): 210-217, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33340204

RESUMO

Clinical signs of liver lobe torsion in rabbits are often nonspecific and mimic those that are also generally detected with gastrointestinal stasis. Nonspecific clinical signs may result in pursuit of full-body imaging such as computed tomography (CT). The aim of this multicenter, retrospective, case series study was to describe CT findings of liver lobe torsion in a group of rabbits. Computed tomography studies of six rabbits with confirmed liver lobe torsion by surgery or necropsy were evaluated. The caudate liver lobe was affected in six out of six rabbits and was enlarged, rounded, hypoattenuating, heterogeneous, and minimally to noncontrast enhancing, with scant regional peritoneal effusion. Precontrast, mean Hounsfield units (HU) of the torsed liver lobe (39.3 HU [range, 24.4-48.1 HU]) were lower than mean HU of normal liver (55.1 HU [range, 49.6-60.8 HU]), with a mean torsed:normal HU ratio of 0.71 (range, 0.49-0.91). Postcontrast, mean HU of the torsed liver lobe (38.4 HU [range, 19.7-48.9 HU]) were also lower than mean HU of normal liver (108.4 HU [range, 84.5-142.0 HU]), with a lower postcontrast mean torsed:normal HU ratio of 0.35 (range, 0.14-0.48) compared to precontrast. Mean HU of torsed liver lobes had little difference pre- and postcontrast (postcontrast HU 1.0 times the average precontrast HU [range, 0.81-1.1]), and contrast enhancement of the torsed liver lobes was on average 50% lower than in normal liver. Liver lobe torsion should be considered in rabbits with an enlarged, hypoattenuating, heterogeneous, minimally to noncontrast enhancing liver lobe, particularly the caudate lobe, and scant regional peritoneal effusion.


Assuntos
Hepatopatias/veterinária , Tomografia Computadorizada por Raios X/veterinária , Anormalidade Torcional/veterinária , Animais , Feminino , Fígado/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Masculino , Coelhos , Estudos Retrospectivos , Anormalidade Torcional/diagnóstico por imagem
8.
Vet Radiol Ultrasound ; 60(6): 613-632, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31243852

RESUMO

Advances in interventional radiology and surgical techniques now allow complex abdominal diseases to be more successfully treated in small animals. Abdominal vascular alterations, acquired as individual process or as complication of other lesions such as neoplasia, can be life-threatening or at least greatly limit curative interventions of underlying diseases. Computed tomography (CT) and high-definition ultrasonography are now readily available in veterinary referral centers. Yet, there is little information currently available on the use of these modalities for the diagnosis and characterization of these vascular alterations. The purpose of this article is to review the CT and ultrasonographic findings of acquired vascular diseases in the abdomen of dogs and cats, using both the veterinary and human medicine literature as references, and highlighting essential concepts through figures.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Circulação Esplâncnica , Doenças Vasculares/veterinária , Abdome/diagnóstico por imagem , Animais , Gatos , Cães , Trombose/diagnóstico por imagem , Trombose/veterinária , Tomografia Computadorizada por Raios X/veterinária , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/veterinária , Ultrassonografia/veterinária , Doenças Vasculares/tratamento farmacológico
9.
Pediatr Int ; 61(5): 504-507, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30825401

RESUMO

BACKGROUND: The aim of this study was to determine ovarian reserve using serum anti-Müllerian hormone (AMH) level in children who had undergone either ovarian-preserving surgery or oophorectomy because of ovarian torsion. METHODS: Patients aged > 10 years who had undergone surgery for unilateral ovarian torsion were contacted for the study with ethics committee approval. Seventeen patients agreed to be included. RESULTS: A total of 10 patients had undergone ovarian detorsion and seven had undergone oophorectomy. Mean age at operation was 11.6 ± 2.23 years (range, 8-15 years) and 13.2 ± 2.17 years (range, 10-16 years), respectively (P = 0.46). Ovarian torsion was isolated in four patients in the first group, and in three in the second. The remainder had associated benign masses. At the time of this study, mean patient age was 18 ± 2.11 years (range, 14-21 years) with a mean postoperative follow up of 5.9 ± 2.8 years (range, 2-10.5 years). Echogenicity of all preserved ovaries was normal on pelvic Doppler ultrasonography, with presence of antral follicles in six. Three ovaries were smaller than expected for age, although two of these had antral follicles. Mean AMH was 5.54 ± 2.25 ng/mL in the detorsion group and 2.70 ± 2.11 ng/mL in the oophorectomy group (P = 0.04). CONCLUSIONS: The presence of follicles in preserved ovaries after detorsion has been reported previously. AMH is expressed in granulosa cells of growing follicles and its serum level is valuable in assessing the quantitative aspects of ovarian reserve. Preservation of the ovary in children with torsion is justified in terms of future ovarian reserve.


Assuntos
Hormônio Antimülleriano/sangue , Doenças Ovarianas/sangue , Doenças Ovarianas/cirurgia , Reserva Ovariana , Anormalidade Torcional/sangue , Anormalidade Torcional/cirurgia , Adolescente , Fatores Etários , Criança , Feminino , Seguimentos , Humanos , Tratamentos com Preservação do Órgão , Doenças Ovarianas/diagnóstico por imagem , Ovariectomia , Fatores de Tempo , Anormalidade Torcional/diagnóstico por imagem , Ultrassonografia Doppler , Adulto Jovem
10.
Injury ; 49(10): 1895-1900, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30097311

RESUMO

INTRODUCTION: The purpose of this study is to evaluate the intra- and inter-observer reliability of low-dose protocolled bilateral postoperative Computed Tomography (CT)-assessment of rotational malalignment after intramedullary nailing (IMN) of tibial shaft fractures. MATERIALS AND METHODS: 156 patients were prospectively included with tibial shaft fractures that were treated with IMN in a Level-I Trauma Centre. All patients underwent post-operative bilateral low-dose CT-assessment (effective dose of 0.03784 - 0.05768 mGy) as per hospital protocol. Four observers performed the validated reproducible measurements of tibial torsion in degrees, based on standardized techniques. The Intra-Class Coefficient (ICC) was calculated to evaluate intra- and inter-observer reliability. The intra- and inter-observer reliability was categorized according to Landis and Koch. RESULTS: Intra-observer reliability for quantification of rotational malalignment on post-operative CT after IMN of tibial shaft fractures was excellent with 0.95 (95% CI = 0.92-0.97). The overall inter-observer reliability was 0.90 (95% CI = 0.87-0.92), also excellent according Landis and Koch. CONCLUSION: Firstly, bilateral post-operative low-dose -similar radiation exposure as plain chest radiographs- CT assessment of tibial rotational alignment is a reliable diagnostic imaging modality to assess rotational malalignment in patients following IMN of tibial shaft fractures and it allows for early revision surgery. Secondly, it may contribute to our understanding of the incidence-, predictors- and clinical relevance of post-operative tibial rotational malalignment in patients treated with IMN for a tibial shaft fracture, and facilitates future studies on this topic.


Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Fixação Intramedular de Fraturas/efeitos adversos , Articulação Patelofemoral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Anormalidade Torcional/diagnóstico por imagem , Adulto , Mau Alinhamento Ósseo/fisiopatologia , Feminino , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Humanos , Masculino , Articulação Patelofemoral/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Reprodutibilidade dos Testes , Fraturas da Tíbia/fisiopatologia
11.
AJR Am J Roentgenol ; 211(1): 155-161, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29733696

RESUMO

OBJECTIVE: The objective of our study was to evaluate a novel measurement technique for assessing the supra- and infratrochanteric components of femoral torsion, establish reference values in healthy volunteers, and compare supra- and infratrochanteric torsion angles in patients with hip dysplasia and patients with femoroacetabular impingement (FAI) with those in healthy volunteers. MATERIALS AND METHODS: Femoral torsion was assessed in 380 patients and 61 healthy volunteers on MRI. For assessing supra- and infratrochanteric torsion, three measurement techniques (i.e., Kim, simplified Kim, and centroid methods) were evaluated by two readers on 100 patients. The technique with the highest interreader reliability was selected to perform measurements on all patients and volunteers. Supra- and infratrochanteric torsion angles of patients were stratified by hip disorders, which were diagnosed by specialized hip surgeons, and were compared with reference values of healthy volunteers. Statistical analysis included the independent t test, Mann-Whitney U test, and intraclass correlation coefficient (ICC). RESULTS: The centroid method showed the highest interreader reliability for measuring supra-and infratrochanteric torsion with an ICC of 0.979. The supra- and infratrochanteric torsion values of the volunteers were 31.5° ± 7.4° (mean ± SD) and -18.3° ± 9.9°, respectively. In comparison with the volunteers, patients with hip dysplasia had significantly higher supraand infratrochanteric torsion values of 37.5° ± 10.3° (p = 0.001) and -9.6° ± 11.7° (p < 0.001) and patients with pincer-type FAI had significantly higher supratrochanteric torsion values of 37.8° ± 8.0° (p = 0.002). CONCLUSION: The supra- and infratrochanteric components of femoral torsion differ substantially between hip disorders: Patients with hip dysplasia have predominantly increased infratrochanteric torsion, whereas patients with pincer-type FAI have increased supratrochanteric torsion. Quantification of separate supra- and infratrochanteric torsion angles allows a more detailed analysis of hip disorders and may influence treatment planning.


Assuntos
Mau Alinhamento Ósseo/diagnóstico por imagem , Impacto Femoroacetabular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Luxação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Anormalidade Torcional/diagnóstico por imagem , Adulto , Mau Alinhamento Ósseo/etiologia , Mau Alinhamento Ósseo/fisiopatologia , Estudos de Casos e Controles , Feminino , Impacto Femoroacetabular/complicações , Impacto Femoroacetabular/fisiopatologia , Fêmur/fisiopatologia , Luxação do Quadril/complicações , Luxação do Quadril/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Anormalidade Torcional/etiologia , Anormalidade Torcional/fisiopatologia
12.
Int Orthop ; 42(6): 1227-1231, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28808753

RESUMO

PURPOSE: De-rotational osteotomies are indicated in patients with pathologic femoral torsion. However, there is disagreement whether an osteotomy should be performed proximally or distally. Conventionally only the total torsion is measured, which does not allow differentiation between a torsional deformity located in the proximal or distal metaphysis or the diaphysis. The aim of this study is to validate a new multi-level measurement protocol for evaluation of the magnitude of torsion of the respective femoral segments in CT. PATIENTS AND METHODS: The torsional profile of 30 femora was evaluated in CT scans. For separate measurements of the torsion of the metaphysis and the diaphysis, four axes where determined: one through the femoral neck, a second determined by the midpoint of the femoral shaft and the lesser trochanter, a third determined by a tangent dorsal to the popliteal surface, and a fourth axis posterior to the condyles. The total femoral torsion was measured between the first and the fourth axis, proximal torsion between the first and the second, mid torsion between the second and the third, and distal torsion between the third and the fourth axis. Four investigators performed all measurements independently and intra-class correlation coefficients (ICC) were calculated to evaluate intra- and inter-rater reliability. RESULTS: Average total femoral torsion was 22.6 ± 8.7°, proximal torsion 47.7 ± 10.6°, mid torsion -33.4 ± 9.9°, and distal torsion 8.3 ± 3.2°. Intra-rater ICC ranged between 0.504 and 0.957 and inter-rater ICC between 0.643 and 0.992. The majority of the ICC were graded as "almost perfect" and some as "substantial" agreement. CONCLUSION: Evaluation of the segmental torsion of the femur allows in-depth analysis of femoral alignment. High reliability was shown for this measuring method in computed tomography, which can be deployed when studying interdependencies between joint pathologies and torsional deformities or when planning the site for an osteotomy. LEVEL OF EVIDENCE: Level III.


Assuntos
Fêmur/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/diagnóstico por imagem , Adolescente , Adulto , Feminino , Fêmur/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
13.
J Obstet Gynaecol Can ; 39(2): 82-90, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28241927

RESUMO

OBJECTIVE: To review the evidence and provide recommendations on the diagnosis and management of adnexal torsion in children, adolescents, and women. OUTCOMES: Elements evaluated include the risk factors, diagnostic accuracy, management options, and outcomes of adnexal torsion. EVIDENCE: Published literature was retrieved through searches of MEDLINE, Embase, CINAHL, and the Cochrane Library using appropriate controlled vocabulary and key words ("adnexal torsion," "ovarian torsion"). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Searches were updated on a regular basis and new material incorporated in the guideline to December 2014. Grey (unpublished) literature was identified through searching the websites of health technology assessment and related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. VALUES: The evidence obtained was reviewed and evaluated by the Canadian Paediatric and Adolescent Gynaecology and Obstetrics Committee of the Society of Obstetricians and Gynaecologists of Canada (SOGC) under the leadership of the principal authors. Recommendations were made according to guidelines developed by the Canadian Task Force on the Periodic Health Examination. BENEFITS, HARMS AND COSTS: Guideline implementation should assist the practitioner in developing an optimal approach to the diagnosis and management of adnexal torsion while minimizing harm and improving patient outcomes. VALIDATION: These guidelines have been reviewed and approved by the Gynaecology Committee of the SOGC and approved by the council of the SOGC. SPONSOR: The Society of Obstetricians and Gynaecologists of Canada SUMMARY STATEMENTS: RECOMMENDATIONS.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Doenças dos Anexos/cirurgia , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia , Dor Abdominal/etiologia , Doenças dos Anexos/etiologia , Doenças dos Anexos/fisiopatologia , Adolescente , Adulto , Canadá , Criança , Feminino , Humanos , Laparoscopia , Ovário/fisiopatologia , Ovário/cirurgia , Fatores de Risco , Anormalidade Torcional/etiologia , Anormalidade Torcional/fisiopatologia , Ultrassonografia Doppler em Cores
14.
BMJ Case Rep ; 20172017 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-28232373

RESUMO

Objective assessment of fundus torsion is currently performed with indirect ophthalmoscopy or fundus photography. Using the infrared image of the macular scan of the optical coherence tomography one can assess the presence and amount of fundus torsion. In addition, the line scan through the fovea can be used as a reference to confirm the position of the foveal pit in relation to the optic nerve head. Two cases are used to demonstrate how to assess fundus torsion with the use of the optical coherence tomography.


Assuntos
Fundo de Olho , Doenças Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica , Anormalidade Torcional/diagnóstico por imagem , Feminino , Fóvea Central/diagnóstico por imagem , Humanos , Raios Infravermelhos , Pessoa de Meia-Idade
15.
Echocardiography ; 34(3): 415-421, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28121047

RESUMO

OBJECTIVE: We sought to investigate the possible interdependence of the left (LV) and right ventricular (RV) rotational mechanics. BACKGROUND: Although myocardial fiber architecture and the effect of various pathologic conditions on LV torsional mechanics have already been investigated through multiple studies using different methods, there is still a significant debate about the actual presence and functional significance of RV rotational mechanics. METHODS: We perform a cross-sectional prospective study of 118 subjects, including 19 normal subjects (NS, 35±7 years), 34 patients with severe aortic stenosis (AS, 44±16 years), 26 patients with nonobstructive hypertrophic cardiomyopathies (HCM, 46±18), and 39 patients with nonischemic dilated cardiomyopathies (DCM, 39±13 years). LV and RV rotational parameters were measured using velocity vector imaging. Total LV and RV apical segment rotations as well as the rotation of the free wall of RV apex were measured separately. Interdependence of the LV and RV rotational mechanics was assessed using the Spearman rho test. RESULTS: Both LV (7.3°±4.1° in NS, 11°±4.6° in AS, 7.7°±5.2° in HCM, and 1.9°±2° in DCM, P=<.0001) and RV apexes (4.7°±2° in NS, 6.1°±4° in AS, 3.2°±3.7° in HCM, and 2.4°±3.6° in DCM, P=<.0001) rotated counterclockwise in all the four study groups. Interventricular apical rotation interdependence was stronger in the AS (Spearman rho [ρ]: .716; P=.000) and in the HCM (ρ: .395; P=.04) subgroups than in the NS (ρ: .26; P=.27) and DCM (ρ: .215; P=.18). In DCM patients, RV apex rotation appeared to be independent of LV rotation. RV free wall apical rotation was larger than its corresponding value for the total apical segments in all studied groups. This difference was significant only in the AS (P=.007). CONCLUSION: Our findings demonstrated a close correlation between RV and LV apical rotation parameters in different cardiac conditions as well as in normal subjects. However, in DCM patients, we also showed some independent rotation of the RV from the LV apex.


Assuntos
Cardiopatias/complicações , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Anormalidade Torcional/diagnóstico por imagem , Adulto , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Rotação , Anormalidade Torcional/complicações , Anormalidade Torcional/fisiopatologia
16.
J Arthroplasty ; 31(5): 1117-22, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26781395

RESUMO

BACKGROUND: Correct assessment of femoral stem torsion is crucial in total hip arthroplasty (THA). In this study, we aimed to compare a recently published novel method based on anteroposterior (AP) hip radiographs using the projected caput-collum-diaphyseal (CCD) angle (AP CCD) with the modified posteroanterior Budin view. METHOD: AP radiographs, modified Budin views, and 3-dimensional computed tomography (3D-CT) images were obtained in 30 patients after minimally invasive, cementless THA. Radiographic measurements performed by 4 observers twice in a 6-week interval were compared with 3D-CT measurements. Furthermore, correlations between the radiographic deviation to 3D-CT and patient specific characteristics were evaluated. RESULTS: We found a mean difference of 2.2 ± 6.8° between AP CCD and 3D-CT measurements of femoral stem torsion and -0.5 ± 4.2° between the modified Budin view and 3D-CT. We found a high correlation between mean radiographic and 3D-CT stem torsion (r = 0.78, P < .001 for AP CCD and r = 0.84, P < .001 for Budin view). The observers had excellent agreements within (intraclass correlation coefficient, ≥0.88 for AP CCD and intraclass correlation coefficient, ≥0.94 for Budin view) and between (mean concordance correlation coefficient, ≥0.79 for AP CCD and concordance correlation coefficient, ≥0.86 for Budin view) their radiographic measurements. CONCLUSION: Both radiographic methods enable a simple orientation and a practical conventional radiographic estimation of stem torsion on hip radiographs after THA. However, CT remains the golden standard for exact estimation of stem torsion.


Assuntos
Artroplastia de Quadril/métodos , Mau Alinhamento Ósseo/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Prótese de Quadril , Anormalidade Torcional/diagnóstico por imagem , Idoso , Artroplastia de Quadril/efeitos adversos , Diáfises/diagnóstico por imagem , Feminino , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pós-Operatório , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
17.
Orthop Surg ; 7(4): 350-3, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26792396

RESUMO

Malrotation is a cause of persistent pain and poor functioning postoperatively in those who undergo a total knee replacement (TKR). The accurate measurement of malrotation is not routinely available in most hospital settings due to an absence of three-dimensional computed tomography (CT) software. An accessible, uncomplicated technique to demonstrate TKR prosthesis malrotation would be of benefit to orthopaedic surgeons worldwide. A patient was reviewed with persistent postoperative pain, having undergone a right TKR 3 years previously for progressive osteoarthritis. Postoperative prosthetic infection, instability, loosening, and fracture were ruled out as causes for the persistent pain. A two-dimensional CT scan was obtained of the patient's affected right knee. Adhesive pieces of paper (Post-it notes) were used to highlight the posterior tibial prosthesis axis, the tibial tuberosity axis, the posterior condylar axis of the femoral prosthesis and the femoral surgical transepicondylar axis, as per the technique described by Berger et al. A protractor was used to assess the degree of malrotation of the tibial and femoral prostheses. Allowing for human error and that of parallax, an immediate assessment was made of the patient's prosthesis using a readily available imaging modality, and malrotation was quickly identified using accessible, affordable everyday stationary equipment.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Humanos , Articulação do Joelho/fisiopatologia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Amplitude de Movimento Articular , Tomografia Computadorizada por Raios X/métodos , Anormalidade Torcional/etiologia
18.
Cardiovasc Ultrasound ; 12: 8, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-24529199

RESUMO

AIMS: 2D speckle tracking echocardiography allows for assessment of left ventricular (LV) torsional deformation as a composite function of the radial, longitudinal and circumferential fibres. We test the hypothesis that post-exercise LV torsional dynamics are more sensitive markers for myocardial dysfunction than resting measures, and better predictors for exercise capacity compared to post-exercise LV diastolic filling pressure (E/e'). METHODS: We studied 88 patients referred for stress echocardiogram. Treadmill exercise was performed using Bruce protocol, and echo images were acquired using GE Vivid 7. LV rotational dynamics were analysed by speckle tracking method using the GE ECHOPAC software. Tertiles were defined according to exercise capacity measured by the achieved metabolic equivalents (METS) adjusted for age and gender. Comparison was made between LV torsional dynamics and E/e' to correlate with METS to predict exercise capacity. RESULTS: Mean age of the study population was 58 years, 48% females. Patients with systolic dysfunction or evidence of ischaemia were excluded from the analysis. No significant correlation was found between METS and LV torsion measures at rest. There was statistically significant correlation between METS and post-exercise LV torsion (r=0.34, p=0.001), twist velocity increase (r=0.27, p=0.01), and incremental change in torsion (r=0.22, p<0.05). In addition, a correlation was also shown between post-exercise E/e' and METS (r=-0.33, p=0.002). CONCLUSION: Post-exercise LV torsional dynamics correlate with exercise capacity and may be a useful tool for assessing LV myocardial function in subjects with normal LVEF.


Assuntos
Teste de Esforço , Ventrículos do Coração/fisiopatologia , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Ecocardiografia/métodos , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico
19.
BMC Res Notes ; 7: 1, 2014 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-24382056

RESUMO

BACKGROUND: Mucus-producing tumours of the appendix or mucoceles can, if left untreated, lead to dissemination of its contents into the peritoneal cavity causing substantial morbidity to the patient. Symptoms for complicated mucoceles can mimic those of acute appendicitis and the final diagnosis is most likely made intraoperatively. We here present a case that is, to our knowledge, one of only ten described in the literature and the first to characterize torsion of an appendiceal mucocele with abdominal magnetic resonance imaging. CASE PRESENTATION: The patient, a 34-year-old Caucasian female presented at the emergency department with acute abdominal pain in the right lower quadrant. Initial diagnostic work-up including ultrasonography and abdominal magnetic resonance imaging showed a large tubular mass at the base of the appendix with indirect signs of torsion. A laparoscopic appendectomy was performed the following day where the finding was confirmed. The patient went on to have an uneventful recovery and was discharged from the hospital on the first postoperative day. CONCLUSIONS: Magnetic resonance imaging is a useful tool in identifying unknown lesions of the appendix and should be considered the primary imaging modality in especially younger patients requiring diagnostic imaging. In this case the preoperative imaging findings aided in choosing the correct timing and treatment option for the patient.


Assuntos
Apendicectomia/métodos , Apêndice/patologia , Doenças do Ceco/cirurgia , Laparoscopia/métodos , Imageamento por Ressonância Magnética , Mucocele/cirurgia , Cuidados Pré-Operatórios/métodos , Anormalidade Torcional/cirurgia , Abdome Agudo/etiologia , Adulto , Apêndice/diagnóstico por imagem , Apêndice/cirurgia , Doenças do Ceco/diagnóstico , Doenças do Ceco/diagnóstico por imagem , Emergências , Feminino , Humanos , Mucocele/complicações , Mucocele/diagnóstico , Mucocele/diagnóstico por imagem , Necrose , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/etiologia , Ultrassonografia
20.
Curr Opin Crit Care ; 19(3): 250-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23519081

RESUMO

PURPOSE OF REVIEW: Speckle tracking is the latest available technology in echocardiography. However, the technology is still mainly used as a research tool. The potential applications of speckle tracking are many, including cardiac synchronization, regional wall motion analysis, and in the areas of cardiac mechanic studies. This review presents the background theory of speckle tracking echocardiography (STE) and how this technology can be extended to velocity vector analysis, strain, and torsion measurements. The interpretations of these measurements are covered. We also present some potential applications in the critical care setting. RECENT FINDINGS: Speckle tracking is almost always available in high-end ultrasound machines. The technology has been applied to velocity vector analysis, strain and strain rate measurements, and twist and torsion analysis. Torsion analysis and velocity vector analyses are impossible without using speckle tracking. Speckle tracking-derived strain is superior to tissue Doppler strain because it is angle-independent. A number of studies demonstrated that STE is useful in left and right heart assessments and can be used in assessing preload and afterload. SUMMARY: Speckle tracking can be used to measure instantaneous myocardial contractility, strain, and left ventricular torsion. It is still a research tool at present, but shows the promise of being a clinical tool in the future.


Assuntos
Ecocardiografia/tendências , Ventrículos do Coração/diagnóstico por imagem , Invenções/tendências , Anormalidade Torcional/diagnóstico por imagem , Previsões , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA