Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 262
Filtrar
Mais filtros

Intervalo de ano de publicação
2.
Acta Radiol ; 64(6): 2205-2210, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37116869

RESUMO

BACKGROUND: Endovascular aortic repair with fenestrated or branched endografts is technically challenging, and proper intraoperative assessment of all stent graft components with only angiography and fluoroscopy can be difficult. Intraoperative computed tomography (CT) imaging can be a valuable aid for the operators in the evaluation of stent grafting results prior to completion of surgery. PURPOSE: To examine the feasibility of performing intraoperative CT imaging during fenestrated and branched endovascular aortic repair (f-bEVAR) under sterile conditions and with patients under general anesthesia. MATERIAL AND METHODS: Intraoperative CT imaging was performed in 10 patients undergoing elective aortic repair with fenestrated or branched endografts. Adverse events, time consumption for CT set-up and image acquisition, and additional radiation dose to the patient were recorded. CT image quality was graded. Immediate corrective maneuvers performed based on the CT findings was registered. RESULTS: There were no adverse events related to intraoperative CT imaging. The median additional operating time by including intraoperative CT was 16 min (interquartile range [IQR] = 12-19), comprising 7% of the median total operating time. The median estimated additional radiation dose to the patient was 4.8 mSv (IQR = 3.8-4.9). All intraoperative CT examinations were considered to be of sufficient quality for stent graft evaluation. No immediate corrective procedures were performed on the basis of CT findings in this study cohort. CONCLUSION: CT imaging intraoperatively during f-bEVAR is feasible with an acceptable increase in operating time and radiation dose.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Estudos de Viabilidade , Correção Endovascular de Aneurisma , Aortografia/métodos , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Estudos Retrospectivos , Fatores de Risco
3.
J Vasc Surg ; 76(3): 645-655.e3, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35367562

RESUMO

OBJECTIVE: Real-time aortic deformation during endovascular aortic aneurysm repair (EVAR) has not been reported. Successful EVAR relies on predicting intraoperative aortic-endograft deformation from preoperative imaging. Correct prediction is essential, because malalignment of endografts decreases patient survival. We describe intraoperative aortic deformation during infrarenal EVAR and complex fenestrated/branched EVAR (F/BEVAR), relating deformation to preoperative anatomy and follow-up outcomes. METHODS: A multicenter, retrospective cohort of aortic aneurysm patients undergoing operation between January 2019 and February 2021, substratified by repair, infrarenal EVAR (n = 50), F/BEVAR (n = 80), and iliac branch graft with F/B/EVAR (IBG + F/B/EVAR; n = 27), were compared using software-based nonrigid two- and three-dimensional aortic deformational intraoperative assessment (CYDAR). Preoperative computed tomography reconstructions of aortic and iliac tortuosities were assessed against intraoperative deformation, the primary outcome, and related to perioperative and follow-up adverse outcomes. RESULTS: All treatment groups had low preoperative visceral aortic tortuosity; the EVAR group had higher iliac tortuosity (1.43 ± 0.05; P = .018). Intraoperative aortic visceral deformation was consistently cranial and anterior; IBG + F/B/EVAR patients had the largest magnitude deformation (superior mesenteric artery, EVAR 5.1 ± 0.9 mm; F/BEVAR 4.4 ± 0.4 mm; IBG 8.3 ± 1.2 mm; P = .004). Celiac artery, superior mesenteric artery, and bilateral renal artery deformations were correlated (R = 0.923-0.983). Iliac deformation was variable in magnitude and direction. Preoperative tortuosity was not correlated with the magnitude of intraoperative deformation nor was deformation magnitude related to endograft instability during follow-up, including endoleak development, reinterventions, or visceral vessel complications. CONCLUSIONS: The aorta deforms consistently during EVAR at the visceral aortic segment but unpredictably at the iliac bifurcation. Aortoiliac deformation is unrelated to adverse perioperative outcomes, branch instability, or reinterventions during short-term follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Vasc Endovascular Surg ; 55(6): 586-592, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33882744

RESUMO

PURPOSE: Nonspecific aortoarteritis (NSAA) is a chronic inflammatory vasculitis involving aorta and its branches. We conducted a study prospectively to compare time resolved magnetic resonance angiography (MRA) with diagnostic digital subtraction angiography (DSA) for the vascular assessment in the patients of NSAA. MATERIALS AND METHODS: Seventeen patients of NSAA were recruited in the study over the period of 3 years. Contrast enhanced MRA using Time-resolved angiography With Interleaved Stochastic Trajectories (TWIST) sequence and diagnostic DSA were performed in these 17 patients. RESULTS: The majority of the patients were young (median age was 25 years, range 8 to 46 years) and 11 patients were females. Erythrocyte sedimentation rate (ESR) was elevated in 9 patients and C-reactive protein (CRP) was elevated in 6 patients. Most commonly involved vessels in our patients were right renal artery (14 patients), abdominal aorta (12 patients) and left renal artery (11 patients). Left and right subclavian arteres were involved in 10 and 6 patients respectively. The sensitivity and specificity of time-resolved MRA using TWIST sequence is 100% as compared to DSA in the assessment of major vessels such as aorta, arch vessels, celiac artery and superior mesenteric artery. However, the sensitivity and specificity of time resolved MRA in the evaluation of renal arteries and vertebral arteries were 100%, 71.4% and 85.7%, 33.3% respectively. No significant association of MRI contrast enhancement with erythrocyte sedimentation rate (p = 1.00) and C-reactive protein (p = 0.600). CONCLUSION: Time resolved MRA images obtained using TWIST sequence were as qualitative as DSA images and can noninvasively evaluate the vascular involvement in NSAA patients.


Assuntos
Angiografia Digital , Aortite/diagnóstico por imagem , Aortografia , Angiografia por Ressonância Magnética , Arterite de Takayasu/diagnóstico por imagem , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
6.
J Cardiovasc Magn Reson ; 23(1): 7, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33557887

RESUMO

BACKGROUND: Patients with thoracic aortic dilatation who undergo annual computed tomography angiography (CTA) are subject to repeated radiation and contrast exposure. The purpose of this study was to evaluate the feasibility of a non-contrast, respiratory motion-resolved whole-heart cardiovascular magnetic resonance angiography (CMRA) technique against reference standard CTA, for the quantitative assessment of cardiovascular anatomy and monitoring of disease progression in patients with thoracic aortic dilatation.  METHODS: Twenty-four patients (68.6 ± 9.8 years) with thoracic aortic dilatation prospectively underwent clinical CTA and research 1.5T CMRA between July 2017 and November 2018. Scans were repeated in 15 patients 1 year later. A prototype free-breathing 3D radial balanced steady-state free-precession whole-heart CMRA sequence was used in combination with compressed sensing-based reconstruction. Area, circumference, and diameter measurements were obtained at seven aortic levels by two experienced and two inexperienced readers. In addition, area and diameter measurements of the cardiac chambers, pulmonary arteries and pulmonary veins were also obtained. Agreement between the two modalities was assessed with intraclass correlation coefficient (ICC) analysis, Bland-Altman plots and scatter plots. RESULTS: Area, circumference and diameter measurements on a per-level analysis showed good or excellent agreement between CTA and CMRA (ICCs > 0.84). Means of differences on Bland-Altman plots were: area 0.0 cm2 [- 1.7; 1.6]; circumference 1.0 mm [- 10.0; 12.0], and diameter 0.6 mm [- 2.6; 3.6]. Area and diameter measurements of the left cardiac chambers showed good agreement (ICCs > 0.80), while moderate to good agreement was observed for the right chambers (all ICCs > 0.56). Similar good to excellent inter-modality agreement was shown for the pulmonary arteries and veins (ICC range 0.79-0.93), with the exception of the left lower pulmonary vein (ICC < 0.51). Inter-reader assessment demonstrated mostly good or excellent agreement for both CTA and CMRA measurements on a per-level analysis (ICCs > 0.64). Difference in maximum aortic diameter measurements at baseline vs follow up showed excellent agreement between CMRA and CTA (ICC = 0.91). CONCLUSIONS: The radial whole-heart CMRA technique combined with respiratory motion-resolved reconstruction provides comparable anatomical measurements of the thoracic aorta and cardiac structures as the reference standard CTA. It could potentially be used to diagnose and monitor patients with thoracic aortic dilatation without exposing them to radiation or contrast media.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia , Angiografia por Tomografia Computadorizada , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/patologia , Dilatação Patológica , Progressão da Doença , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
7.
JACC Cardiovasc Interv ; 14(5): 531-538, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33582086

RESUMO

OBJECTIVES: The aim of this study was to investigate the online assessment feasibility of aortography using videodensitometry in the catheterization laboratory during transcatheter aortic valve replacement (TAVR). BACKGROUND: Quantitative assessment of regurgitation after TAVR through aortography using videodensitometry is simple, reproducible, and validated in vitro, in vivo, in clinical trials, and in "real-world" patients. However, thus far the assessment has been done offline. METHODS: This was a single center, prospective, proof-of-principle, feasibility study. One hundred consecutive patients with aortic stenosis and indications to undergo TAVR were enrolled. All final aortograms were analyzed immediately after acquisition in the catheterization laboratory and were also sent to an independent core laboratory for blinded offline assessment. The primary endpoint of the study was the feasibility of the online assessment of regurgitation (percentage of analyzable cases). The secondary endpoint was the reproducibility of results between the online assessment and the offline analysis by the core laboratory. RESULTS: Patients' mean age was 81 ± 7 years, and 56% were men. The implanted valves were either SAPIEN 3 (97%) or SAPIEN 3 Ultra (3%). The primary endpoint of online feasibility of analysis was 92% (95% confidence interval [CI]: 86% to 97%) which was the same feasibility encountered by the core laboratory (92%; 95% CI: 86% to 97%). Reproducibility assessment showed a high correlation between online and core laboratory evaluations (R2 = 0.87, p < 0.001), with an intraclass correlation coefficient of 0.962 (95% CI: 0.942 to 0.975; p < 0.001). CONCLUSIONS: This study showed high feasibility of online quantitative assessment of regurgitation and high agreement between the online examiner and core laboratory. These results may pave the way for the application of videodensitometry in the catheterization laboratory after TAVR. (Online Videodensitometric Assessment of Aortic Regurgitation in the Cath-Lab [OVAL]; NCT04047082).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Aortografia , Estudos de Viabilidade , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
J Vasc Surg ; 73(4): 1277-1281, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32987147

RESUMO

OBJECTIVE: The type III arch configuration has been inconsistently reported as a stroke risk factor during carotid artery stenting. However, at least three different methods for the definition of type III arch can be identified in the literature, related to the level of the origin of the innominate artery (IA). According to Casserly's definition, a type III arch presents with an origin of the IA below the horizontal plane of the inner curvature. According to Madhwal's definition, a type III arch has a distance greater than twice the diameter of the left common carotid artery between the highest point of the arch and the origin of the IA. According to MacDonald's definition, a type III arch presents with a distance of ≥2 cm between the highest point of the arch and the origin of the IA. Our aim was to assess the level of concordance between these different methods. METHODS: Anonymized thoracic computed tomography scans of 100 healthy patients were reviewed. Two of us independently stratified the selected cases as a type I to III arch, according to the three considered definitions. The interobserver level of concordance for each type III arch classification and level of concordance among the three definitions were assessed. RESULTS: The 100 selected patients (64% male) were 76 ± 7 years old. For each definition, the interobserver repeatability was almost perfect for all three (Madhwal, κ = 0.81; 95% confidence interval [CI], 0.71-0.99; MacDonald, κ = 0.82; 95% CI, 0.72-0.92; Casserly, κ = 0.84; 95% CI, 0.74-0.93). The level of concordance among the different definitions was very low (Madhwal vs MacDonald, 85% [P = .002]; 33% for type III arch; Madhwal vs Casserly, 60% [P < .0001]; 12% for type III arch; MacDonald vs Casserly, 75% [P < .0001]; 12% for type III arch). CONCLUSIONS: The three definitions of the type III arch have a very low level of concordance, which might account for the varying clinical relevance of this configuration. Our findings have relevant implications for risk prediction for carotid artery stenting based on the presence of a type III arch, for comparisons of the results from different studies, and for comparisons of different datasets from multicenter trials.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aortografia , Doenças das Artérias Carótidas/terapia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Stents , Malformações Vasculares/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta Torácica/anormalidades , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico por imagem , Tomada de Decisão Clínica , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Malformações Vasculares/complicações
10.
Ann Vasc Surg ; 72: 321-329, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33160060

RESUMO

BACKGROUND: To compare aortic sac changes after endovascular aneurysm repair (EVAR) assessed by three-dimensional ultrasound (3D-US), two-dimensional ultrasound (2D-US), and traditional computed tomographic angiography (CTA). METHODS: Using volume assessment with three-dimensional CTA (3D-CTA-volume) as the gold standard, this study investigated aortic sac changes at three and 12 months after EVAR with three different ultrasound methods (2D-US anterior-posterior (AP) diameter, 3D-US AP centerline diameter, and 3D-US partial volume), and traditional CT multiplanar outer-to-outer diameter (CT-MPR OTO diameter). From august 1st, 2011 to January 2014, consecutive EVAR patients (n = 113) were available for analysis in two time intervals; 1) between preoperative and three-month follow-up and 2) between three and 12 month follow-up. RESULTS: The risk of missing true aortic sac growth (false negative finding) at three-month postoperative visit using 3D-US partial volume, 3D-US AP centerline diameter, 2D-US AP diameter, and CT-MPR OTO diameter was 19%, 21%, 22%, and 18%, respectively. Corresponding low sensitivities (0% to 21%) and kappa-values (<0.50) in detecting aortic sac changes were found. The risk of missing true growth between three and 12 months were lower (6%, 5%, 6%, and 6%, respectively), and matching sensitivities 33%, 33%, 17%, and 17%, respectively. CONCLUSIONS: All tested methods for aortic sac changes were as good as traditional CT-MPR OTO diameter and corresponded poorly with 3D-CTA-volume at three months postoperative visit but substantially better after 12 months where the residual sac change was more profound.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Imageamento Tridimensional , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
12.
Eur J Vasc Endovasc Surg ; 60(3): 365-373, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32253165

RESUMO

OBJECTIVE: To test whether aneurysm biomechanical ratio (ABR; a dimensionless ratio of wall stress and wall strength) can predict aneurysm related events. METHODS: In a prospective multicentre clinical study of 295 patients with an abdominal aortic aneurysm (AAA; diameter ≥ 40 mm), three dimensional reconstruction and computational biomechanical analyses were used to compute ABR at baseline. Participants were followed for at least two years and the primary end point was the composite of aneurysm rupture or repair. RESULTS: The majority were male (87%), current or former smokers (86%), most (72%) had hypertension (mean ± standard deviation [SD] systolic blood pressure 140 ± 22 mmHg), and mean ± SD baseline diameter was 49.0 ± 6.9 mm. Mean ± SD ABR was 0.49 ± 0.27. Participants were followed up for a mean ± SD of 848 ± 379 days and rupture (n = 13) or repair (n = 102) occurred in 115 (39%) cases. The number of repairs increased across tertiles of ABR: low (n = 24), medium (n = 34), and high ABR (n = 44) (p = .010). Rupture or repair occurred more frequently in those with higher ABR (log rank p = .009) and ABR was independently predictive of this outcome after adjusting for diameter and other clinical risk factors, including sex and smoking (hazard ratio 1.41; 95% confidence interval 1.09-1.83 [p = .010]). CONCLUSION: It has been shown that biomechanical ABR is a strong independent predictor of AAA rupture or repair in a model incorporating known risk factors, including diameter. Determining ABR at baseline could help guide the management of patients with AAA.


Assuntos
Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/etiologia , Hemodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/fisiopatologia , Ruptura Aórtica/cirurgia , Aortografia , Fenômenos Biomecânicos , Angiografia por Tomografia Computadorizada , Progressão da Doença , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Procedimentos Cirúrgicos Vasculares
13.
Eur J Vasc Endovasc Surg ; 60(2): 171-179, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32209282

RESUMO

OBJECTIVE: Endovascular aortic aneurysm repair (EVAR) is associated with the risk of late complications and mandates follow up. This retrospective study assessed post-EVAR complications in a two centre cohort. The study evaluated the rate of complications presenting with symptoms vs. those detected by imaging follow up. Additionally, the agreement between DUS and CTA in detecting complications was assessed in patients with both. METHODS: All EVAR patients from 1998 to 2012 in two centres were included. Complications were classified based on whether they were symptomatic or detected by imaging, as well as based on imaging detection modality (DUS or CTA). For patients who had undergone DUS and CTA within three months of each other, the kappa coefficient of agreement was assessed. RESULTS: Four hundred and fifty-four patients treated by EVAR were identified. The median follow up time was 5.2 (IQR 2.8-7.6) years. One hundred and eighteen patients (26%) developed 176 complications. One hundred and six (60.2%) of the complications were asymptomatic, and 70 (39.8%) were symptomatic. Two hundred and fifty-three patients had imaging with both modalities within three months of each other; the kappa coefficient for agreement between CTA and DUS for detecting clinically significant complications was 0.91. Regarding CTA as the standard modality, DUS had a sensitivity of 88.8% (95% CI 77.3-95.8%) and a specificity of 99.4% (95% CI 97.1-99.9%). Three of the complications missed by DUS were related to loss of proximal and distal seal, all occurring in patients with short sealing length on first post-operative CT scan. CONCLUSION: Approximately a quarter of the patients developed complications, the majority of which were asymptomatic, underlining the importance of adequate surveillance. There was good agreement between CTA and DUS in detecting complications. Clinically significant complications related to inadequate seal were missed by DUS, suggesting that CTA still plays an important role in EVAR surveillance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Suécia , Fatores de Tempo , Resultado do Tratamento
14.
J Vasc Surg ; 72(3): 886-895.e1, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31964574

RESUMO

OBJECTIVE: Trials for endovascular aneurysm repair (EVAR) report lower perioperative mortality and morbidity, but also higher costs compared with open repair. However, few studies have examined the subsequent cost of follow-up evaluations and interventions. Therefore, we present the index and 5-year follow-up costs of EVAR from the Endurant Stent Graft System Post Approval Study. METHODS: From August 2011 to June 2012, 178 patients were enrolled in the Endurant Stent Graft System Post Approval Study de novo cohort and treated with the Medtronic Endurant stent graft system (Medtronic Vascular, Santa Rosa, Calif), of whom 171 (96%) consented for inclusion in the economic analysis and 177 participated in the quality-of-life (QOL) assessment over a 5-year follow-up period. Cost data for the index and follow-up hospitalizations were tabulated directly from hospital bills and categorized by Uniform Billing codes. Surgeon costs were calculated by Current Procedural Terminology codes for each intervention. Current Procedural Terminology codes were also used to calculate imaging and clinic follow-up reimbursement as surrogate to cost based on year-specific Medicare payment rates. Additionally, we compared aneurysm-related versus nonaneurysm-related subsequent hospitalization costs and report EuroQol 5D QOL dimensions. RESULTS: The mean hospital cost per person for the index EVAR was $45,304 (interquartile range [IQR], $25,932-$44,784). The largest contributor to the overall cost was operating room supplies, which accounted for 50% of the total cost at a mean of $22,849 per person. One hundred patients had 233 additional post index admission inpatient admissions; however, only 32 readmissions (14%) were aneurysm related, with a median cost of $13,119 (IQR, $4570-$24,153) compared with a nonaneurysm-related median cost of $6609 (IQR, $1244-$26,466). Additionally, 32 patients were admitted a total of 37 times for additional procedures after index admission, of which 14 (38%) were aneurysm-related. The median cost of hospitalization for aneurysm-related subsequent intervention was $22,023 (IQR, $13,177-$47,752), compared with a median nonaneurysm-related subsequent intervention cost of $19,007 (IQR, $8708-$33,301). After the initial 30-day visit, outpatient follow-up imaging reimbursement averaged $550 per person per year ($475 for computed tomography scans, $75 for the abdomen), whereas annual office visits averaged $107 per person per year, for a total follow-up reimbursement of $657 per person per year. There were no significant differences in the five EuroQol 5D QOL dimensions at each follow-up compared with baseline. CONCLUSIONS: Costs associated with index EVAR are driven primarily by cost of operating room supplies, including graft components. Subsequent admissions are largely not aneurysm related; however, cost of aneurysm-related hospitalizations is higher than for nonaneurysm admissions. These data will serve as a baseline for comparison with open repair and other devices.


Assuntos
Aneurisma da Aorta Abdominal/economia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/economia , Prótese Vascular/economia , Procedimentos Endovasculares/economia , Custos Hospitalares , Stents/economia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/economia , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/economia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Reembolso de Seguro de Saúde/economia , Masculino , Visita a Consultório Médico/economia , Salas Cirúrgicas/economia , Readmissão do Paciente/economia , Vigilância de Produtos Comercializados/economia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
Heart ; 106(2): 133-139, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31551294

RESUMO

OBJECTIVE: To provide population-based distributions of thoracic aortic diameters in men and women aged 55 years or older and to identify determinants of thoracic aortic diameters. METHODS: From 2003 to 2006, 2505 participants (1208 men, mean age 69.1±6.8 years) from the prospective population-based Rotterdam Study underwent non-enhanced cardiac CT. The diameter of the ascending (AA) and descending aorta (DA) was measured at the level of the pulmonary bifurcation. RESULTS: The mean diameter of the ascending and descending aorta was substantially larger in men (38±4 mm and 30±2 mm) than in women (35±3 mm and 27±2 mm). An ascending aortic diameter of larger than 40 mm was found in 228 (18.9%) men and 76 (5.9%) women and a descending aortic diameter larger than 40 mm was found in two men and no women. Male sex was found to be independently associated with larger DA diameter (standardised ß 0.24, 95% CI 0.19 to 0.30), while a statistically non-significant trend was found for the AA diameter (standardised ß 0.06, 95% CI 0.00 to 0.12). Age, height, weight and traditional cardiovascular risk factors were also associated with larger AA and/or DA diameters. Diabetes was associated with smaller AA and DA diameters. We found no evidence for effect modification by sex. CONCLUSIONS: In persons aged 55 years or older, an ascending aortic diameter of 40 mm or larger was found in 18.9% of men and 5.9% of women. Given the importance of sex, sex-specific distribution values may prove useful in clinical practice, even when correcting for body surface area or height.


Assuntos
Envelhecimento , Aorta Torácica/diagnóstico por imagem , Aortografia , Angiografia por Tomografia Computadorizada , Disparidades nos Níveis de Saúde , Tomografia Computadorizada Multidetectores , Fatores Etários , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores Sexuais
16.
J Cardiovasc Comput Tomogr ; 14(1): 68-74, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31416723

RESUMO

BACKGROUND: Computed tomographic angiography (CTA) based planning for transcatheter aortic valve replacement (TAVR) is essential for reduction of periprocedural complications. Spectral CT based imaging provides several advantages, including better contrast/signal to noise ratio and increased soft tissue contrast, permitting better delineation of contrast filled structures at lower doses of iodinated contrast media. The aim of this prospective study was to assess the initial feasibility of a low dose iodinated contrast protocol, utilizing monoenergetic 40 keV reconstruction, using a dual-layer CT scanner (DLCT) for CTA in patients undergoing TAVR planning. METHODS: 116 consecutive TAVR patients underwent a gated chest and a non-gated CTA of the abdomen and pelvis. 40 keV virtual monoenergetic images (VMI) were reconstructed and compared with conventional polychromatic images (CI). The proximal aorta and access vessels were scored for image quality by independent experienced cardiovascular imagers. RESULTS: Proximal aortic image quality as assessed by signal to noise (SNR) and contrast to noise ratio (CNR), were significantly better with 40 keV VMI relative to CI (SNR 14.65 ±â€¯7.37 vs 44.16 ±â€¯22.39, p < 0.001; CNR 15.84 ±â€¯9.93 vs 59.8 ±â€¯40.83, p < 0.001). Aortic root dimensions were comparable between the two approaches with a bias towards higher measurements at 40 keV (Bland Altman). SNR and CNR in all access vessel segments at 40 keV were substantially better (p < 0.001 for all peripheral access vessel segments) with comparable image quality. CONCLUSION: 40 keV VMI with low dose contrast dose spectral imaging is feasible for comprehensive preprocedural evaluation of access vessels and measurements of aortic root dimensions in patients undergoing TAVR.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Aortografia , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Iopamidol/administração & dosagem , Doença Arterial Periférica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/fisiopatologia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Aortografia/efeitos adversos , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada/efeitos adversos , Meios de Contraste/efeitos adversos , Feminino , Humanos , Iopamidol/efeitos adversos , Masculino , Doença Arterial Periférica/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Grau de Desobstrução Vascular
17.
J Vasc Surg ; 71(6): 1982-1993.e5, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31611108

RESUMO

OBJECTIVE: The objective of this study was to analyze the utility of cone beam computed tomography (CBCT) for technical assessment of standard and complex endovascular aneurysm repair (EVAR). METHODS: Data of consecutive patients who underwent standard or complex EVAR in 2016 and 2017 at our institution were entered into a prospective database and analyzed retrospectively. There were 154 patients (126 male; mean age, 74 ± 8 years) enrolled in a prospective study between 2016 and 2017. A total of 170 aortic procedures were investigated, including 85 fenestrated-branched EVARs (F-BEVARs), 42 abdominal and thoracic EVARs, 32 EVARs with iliac branch devices, and 11 aorta-related interventions. Technical assessment was done using CBCT with and without contrast enhancement, digital subtraction angiography (DSA), and computed tomography angiography (CTA). Patients with stage 3B or stage 4 chronic kidney disease had CBCT without contrast enhancement. Radiation exposure (mean dose-area product), effective dose (ED), and amount of iodine contrast agent were analyzed. End points were presence of any endoleak, positive findings warranting possible intervention (stent kink or compression, type I or type III endoleak, dissection, thrombus), and need for secondary intervention. RESULTS: Radiation exposure and amount of iodine contrast agent were significantly higher (P < .05) for F-BEVAR compared with other aortic procedures (174±101 Gy∙cm2 vs 1135±113 Gy∙cm2 and 144±60 mL vs 122±49 mL). ED averaged 74±36 mSv for the aortic procedure, 18 ± 18 mSv for fluoroscopy, 7 ± 7 mSv for DSA acquisition, 15±7 mSv for CBCT, and 34±17 mSv for CTA imaging (P < .001). Endoleak detection was significantly higher (P < .001) with CBCT (53%) compared with DSA (14%) and CTA (46%). CBCT identified 52 positive findings in 43 patients (28%), higher for F-BEVAR compared with other aortic procedures (35% vs 16%; P = .01). Positive findings included stent compression or kink in 29 patients (17%), type I or type III endoleak in 16 patients (10%), and arterial dissection or thrombus in 7 patients (5%). Of these, 28 patients (18%) had positive findings that prompted an intraoperative (17%) or delayed intervention (1%). Another 15 patients (10%) with minor positive findings were observed with no clinical consequence. DSA alone would not have detected positive findings in 34 of 43 patients (79%), including 21 patients (49%) who needed secondary interventions. CTA diagnosed two (1%) additional endoleaks requiring intervention (one type IC, one type IIIC) that were not diagnosed by CBCT. Replacing DSA and CTA by CBCT would have resulted in 53% ± 13% reduction in amount of iodine contrast agent and 55% ± 12% reduction in ED (P < .05). CONCLUSIONS: CBCT reliably detected positive findings prompting immediate revisions in nearly one of five patients, with the highest rates among F-BEVAR patients. Detection of any endoleak was higher with CBCT compared with DSA or CTA, but most endoleaks were observed. DSA alone failed to detect positive findings warranting revisions.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aortografia , Implante de Prótese Vascular , Tomografia Computadorizada de Feixe Cônico , Procedimentos Endovasculares , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
20.
J Endovasc Ther ; 26(5): 697-703, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31282253

RESUMO

Purpose: To evaluate chimney stent-graft position and morphological changes of the aneurysm sac as visualized by postoperative computed tomography angiography (CTA) over a minimum 24-month follow-up period. Materials and Methods: Twenty-one patients (mean age 75.7±8.6 years; 20 men) with juxtarenal aortic aneurysms who underwent successful chimney endovascular aneurysm repair (ch-EVAR) with the Endurant stent-graft and had 2 postoperative CTAs separated by at least 24 months were included in the study. CTA-based measurements of aortic stent-graft migration, target vessel angle, and chimney angle were compared between the serial scans. Results: During a mean follow-up of 34.9 months (range 24-69.2), the mean migration of the aortic stent-grafts was under 5 mm (2.76±2.4 mm). The average migration distance per year was 1.15 mm. The aneurysm diameter reduced a mean 3.25 mm (p=0.048). The right renal artery angle moved significantly upward 6.72° (p=0.025), while the right renal chimney stent-graft moved significantly downward 7.83° (p=0.042). The left renal artery angle also moved upward 1.87° (p=0.388) and the corresponding chimney moved downward 5.68° (p=0.133). During the study period, no type I/III endoleak or chimney occlusion was observed. Conclusion: Midterm morphometric assessment of ch-EVAR using CTA showed significant aneurysm sac shrinkage and a stable 3-year position of the abdominal devices, with the mean downward migration of the aortic stent-graft being <5 mm in the majority of cases. The chimney grafts seem to be prone to take an oblique rather than parallel configuration during follow-up. However, there was no relevant clinical consequence related to this phenomenon.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/diagnóstico por imagem , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA