Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 735
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Am Heart Assoc ; 13(13): e035171, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38904248

RESUMO

BACKGROUND: Cervical arterial tortuosity is associated with adverse outcomes in Loeys-Dietz syndrome and other heritable aortopathies. METHODS AND RESULTS: A method to assess tortuosity based on curvature of the vessel centerline in 3-dimensional space was developed. We measured cervical carotid tortuosity in 65 patients with Loeys-Dietz syndrome from baseline computed tomography angiogram/magnetic resonance angiogram and all serial images during follow-up. Relations between baseline carotid tortuosity, age, aortic root diameter, and its change over time were compared. Patients with unoperated aortic roots were assessed for clinical end point (type A aortic dissection or aortic root surgery during 4 years of follow-up). Logistic regression was performed to assess the likelihood of clinical end point according to baseline carotid tortuosity. Total absolute curvature at baseline was 11.13±5.76 and was relatively unchanged at 8 to 10 years (fold change: 0.026±0.298, P=1.00), whereas tortuosity index at baseline was 0.262±0.131, with greater variability at 8 to 10 years (fold change: 0.302±0.656, P=0.818). Baseline total absolute curvature correlated with aortic root diameter (r=0.456, P=0.004) and was independently associated with aortic events during the 4-year follow-up (adjusted odds ratio [OR], 2.64 [95% CI, 1.02-6.85]). Baseline tortuosity index correlated with age (r=0.532, P<0.001) and was not associated with events (adjusted OR, 1.88 [95% CI, 0.79-4.51]). Finally, baseline total absolute curvature had good discrimination of 4-year outcomes (area under the curve=0.724, P=0.014), which may be prognostic or predictive. CONCLUSIONS: Here we introduce cervical carotid tortuosity as a promising quantitative biomarker with validated, standardized characteristics. Specifically, we recommend the adoption of a curvature-based measure, total absolute curvature, for early detection or monitoring of disease progression in Loeys-Dietz syndrome.


Assuntos
Artérias Carótidas , Angiografia por Tomografia Computadorizada , Síndrome de Loeys-Dietz , Angiografia por Ressonância Magnética , Humanos , Feminino , Masculino , Medição de Risco , Adulto , Síndrome de Loeys-Dietz/genética , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/diagnóstico por imagem , Pessoa de Meia-Idade , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Fatores de Risco , Adulto Jovem , Valor Preditivo dos Testes , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/diagnóstico , Imageamento Tridimensional , Reprodutibilidade dos Testes , Dermatopatias Genéticas/genética , Dermatopatias Genéticas/diagnóstico por imagem , Dermatopatias Genéticas/diagnóstico
2.
CJEM ; 26(7): 482-487, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38789886

RESUMO

OBJECTIVES: The HEART score is a clinical decision tool that stratifies patients into categories of low, moderate, and high-risk of major adverse cardiac events in the emergency department (ED) but cannot identify underlying cardiovascular disease in patients without prior history. The presence of atherosclerosis can easily be detected at the bedside using carotid ultrasound. Plaque quantification is well established, and plaque composition can be assessed using ultrasound grayscale pixel distribution analysis. This study aimed to determine whether carotid plaque burden and/or composition correlated with risk of events and could improve the sensitivity of the HEART score in risk stratifying ED patients with chest pain. METHODS: The HEART score was calculated based on history, electrocardiogram, age, risk factors, and initial troponin in patients presenting to the ED with chest pain (n = 321). Focused carotid ultrasound was performed, and maximum plaque height and total plaque area were used to determine plaque burden (quantity). Plaque composition (% blood, fat, muscle, fibrous, calcium-like tissue) was assessed by pixel distribution analysis. RESULTS: Carotid plaque height and area increased with HEART score (p < 0.0001). Carotid plaque % fibrous and % calcium also increased with HEART score. The HEART score had a higher area under the curve (AUC = 0.84) in predicting 30-day events compared to the plaque variables alone (AUCs < 0.70). Integrating plaque quantity into the HEART score slightly increased test sensitivity (62-69%) for 30-day events and reclassified 11 moderate-risk participants to high-risk (score 7-10). CONCLUSION: Plaque burden with advanced composition features (fibrous and calcium) was associated with increased HEART score. Integrating plaque assessment into the HEART score identified subclinical atherosclerosis in moderate-risk patients.


RéSUMé: OBJECTIFS: Le score HEART est un outil de décision clinique qui stratifie les patients en catégories de risque faible, modéré et élevé d'événements cardiaques indésirables majeurs à l'urgence (ED), mais ne peut pas identifier les maladies cardiovasculaires sous-jacentes chez les patients sans antécédents. La présence d'athérosclérose peut facilement être détectée au chevet du patient à l'aide de l'échographie carotide. La quantification de la plaque est bien établie et la composition de la plaque peut être évaluée à l'aide d'une analyse échographique de la distribution des pixels en niveaux de gris. Cette étude visait à déterminer si la charge et/ou la composition de la plaque carotidienne étaient corrélées avec le risque d'événements et pouvaient améliorer la sensibilité du score HEART chez les patients souffrant de douleurs thoraciques stratifiés. MéTHODES: Le score HEART a été calculé sur la base des antécédents, de l'électrocardiogramme, de l'âge, des facteurs de risque et de la troponine initiale chez les patients présentant une douleur thoracique à l'urgence (n = 321). L'échographie carotidienne focalisée a été effectuée, et la hauteur maximale de la plaque et la surface totale de la plaque ont été utilisées pour déterminer la charge de plaque (quantité). La composition de la plaque (% de sang, de graisse, de muscle, de tissu fibreux, de type calcique) a été évaluée par analyse de la distribution des pixels. RéSULTATS: La hauteur et la surface de la plaque carotide ont augmenté avec le score HEART (p<0,0001). Le pourcentage de plaque carotide fibreuse et le pourcentage de calcium ont également augmenté avec le score HEART. Le score HEART avait une zone plus élevée sous la courbe (ASC = 0,84) pour prédire les événements de 30 jours par rapport aux seules variables de la plaque (CCU < 0,70). L'intégration de la quantité de plaque dans le score HEART a légèrement augmenté la sensibilité au test (62 % à 69 %) pour les événements de 30 jours et a reclassé 11 participants à risque modéré à risque élevé (score de 7 à 10). CONCLUSION: La charge de plaque avec des caractéristiques de composition avancées (fibreuse et calcique) était associée à une augmentation du score HEART. Intégrer l'évaluation de la plaque dans le score HEART a identifié l'athérosclérose subclinique chez les patients à risque modéré.


Assuntos
Dor no Peito , Serviço Hospitalar de Emergência , Humanos , Masculino , Dor no Peito/etiologia , Dor no Peito/diagnóstico , Dor no Peito/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Medição de Risco/métodos , Idoso , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Eletrocardiografia , Placa Aterosclerótica/diagnóstico por imagem , Fatores de Risco , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/complicações , Ultrassonografia das Artérias Carótidas
3.
Medicina (Kaunas) ; 60(5)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38793019

RESUMO

Background and objective: carotid artery stenosis contributes significantly to ischemic strokes, with management options including carotid endarterectomy (CEA) and carotid artery stenting (CAS) ischemic stroke risk can be reduced. Controversies persist regarding their efficacy and factors influencing complications, and understanding the relationship between atherosclerotic plaque characteristics and stent restenosis after CAS is crucial. Methods: we conducted a retrospective study involving 221 patients who underwent CAS for symptomatic or asymptomatic carotid artery stenosis. Comprehensive assessments of plaque morphology were performed using contrast-enhanced ultrasound (CEUS) before CAS. Patient demographics, including smoking status and diabetes, were also recorded. Stent restenosis was diagnosed using various imaging modalities, including ultrasound, angiography, and digital subtraction angiography (DSA). Results: plaque analysis using CEUS revealed a significant association between plaque grade and restenosis incidence (p < 0.001), particularly with grade 0 (11.1%) and grade 2 plaques (66.7%). Smoking was notably associated with plaque vascularization and restenosis (p < 0.001), while diabetes did not significantly impact plaque characteristics or restenosis risk (p > 0.05). The mean duration of restenosis was 17.67 months. Stenting was the most frequent treatment modality for restenosis (70.6%). However, no significant relationship was found between restenosis type and plaque morphology (p = 0.268). Furthermore, while no clear relationship was observed between plaque morphology and the type of restenosis, our findings underscored the importance of plaque characterization in predicting post-CAS outcomes. Conclusions: this study highlights the utility of CEUS in predicting stent restenosis following CAS. There was a significant association between stent restenosis within 12-24 months after the carotid stenting procedure and an elevated grade of plaque vascularization. Moreover, one of the main factors possibly determining the grade of plaque vascularization was smoking. Further research is warranted to elucidate the underlying mechanisms and refine risk stratification in this patient population.


Assuntos
Estenose das Carótidas , Meios de Contraste , Placa Aterosclerótica , Stents , Ultrassonografia , Humanos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Stents/efeitos adversos , Estenose das Carótidas/cirurgia , Estenose das Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Pessoa de Meia-Idade , Ultrassonografia/métodos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Angiografia Digital/métodos , Idoso de 80 Anos ou mais , Fatores de Risco
4.
Physiol Meas ; 45(3)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38422517

RESUMO

Objective. Carotid ultrasound (US) has been studied as a non-invasive alternative for hemodynamic monitoring. A long-axis (LA) view is traditionally employed but is difficult to maintain and operator experience may impact the diameter estimates, making it unsuitable for monitoring. Preliminary results show that a new, i.e. rotated and tilted (RT) view is more robust to motion and less operator-dependent. This study aimed to quantitatively assess common carotid diameter estimates obtained in a clinical setting from an RT view and compare those to corresponding estimates obtained using other views.Approach. Carotid US measurements were performed in 30 adult cardiac-surgery patients (26 males, 4 females) with short-axis (SA), LA, and RT probe orientations, the first being used as a reference for measuring the true vessel diameter. Per 30 s acquisition, the median and spread in diameter values were computed, the latter representing a measure of robustness, and were statistically compared between views.Main results. The median (IQR) over all the patients of the median diameter per 30 s acquisition was 7.15 (1.15) mm for the SA view, 7.03 (1.51) mm for the LA view, and 6.99 (1.72) mm for the RT view. The median spread in diameter values was 0.18 mm for the SA view, 0.16 mm for the LA view, and 0.18 mm for the RT view. There were no statistically significant differences between views in the median diameter values (p= 0.088) or spread (p= 0.122).Significance. The RT view results in comparable and equally robust median carotid diameter values compared to the reference. These findings open the path for future studies investigating the use of the RT view in new applications, such as in wearable ultrasound devices.


Assuntos
Artérias Carótidas , Salas Cirúrgicas , Adulto , Masculino , Feminino , Humanos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia , Ultrassonografia das Artérias Carótidas
5.
Ultrasound Med Biol ; 50(3): 399-406, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38171954

RESUMO

OBJECTIVE: Three-dimensional contrast-enhanced fusion ultrasound (CEFUS) of atherosclerotic carotid arteries provides spatial visualization of the vessel lumen, creating a lumenography. As in 3-D computed tomography angiography (CTA), 3-D CEFUS outlines the contrast-filled lumen. Plaque and vessel contours are distinguished in 3-D CEFUS, allowing plaque volume quantification as a valid estimate of carotid plaque burden. Three-dimensional CEFUS is unproven in intermodality studies, vindicating the assessment of 3-D CEFUS applicability and comparing 3-D CEFUS and 3-D CTA lumenography as a proof-of-concept study. METHODS: Using an ultrasound system with magnetic tracking, a linear array transducer and SonoVue contrast agent, 3-D CEFUS acquisitions were generated by spatial stitching of serial 2-D images. From 3-D CEFUS and 3-D CTA imaging, the atherosclerotic carotid arteries were reconstructed with lumenography in an offline software program for lumen and plaque volume quantification. Bland-Altman analysis was used for inter-image modality agreement. RESULTS: The study included 39 carotid arteries. Mean lumen and plaque volume in 3-D CEFUS were 0.63 cm3 (standard deviation [SD]: 0.26) and 0.62 cm3 (SD: 0.26), respectively. Lumen volume differences between 3-D CEFUS and 3-D CTA were non-significant, with a mean difference of 0.01 cm3 (SD: 0.02, p = 0.26) and limits of agreement (LoA) range of ±0.11 cm3. Mean plaque volume difference was -0.12 cm3 (SD: 0.19, p = 0.006) with a LoA range of ±0.39 cm3. CONCLUSION: There was strong agreement in lumenography between 3-D CEFUS and 3-D CTA. The interimage modality difference in plaque volumes was substantial because of challenging vessel wall definition in 3-D CTA. Three-dimensional CEFUS is viable in quantifying carotid plaque volume burden and can potentially monitor plaque development over time.


Assuntos
Aterosclerose , Doenças das Artérias Carótidas , Estenose das Carótidas , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Doenças das Artérias Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estenose das Carótidas/diagnóstico por imagem
8.
Ultraschall Med ; 45(1): 14-35, 2024 Feb.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37963572

RESUMO

Ultrasonography of the brain-supplying arteries is a non-invasive and highly efficient technique for the assessment of a stenosis or a vessel occlusion in patients with cerebrovascular diseases. This article reviews the examination technique for a standardized ultrasound assessment of the extracranial carotid and vertebral arteries. It further describes the multiparametric grading criteria of internal carotid artery stenosis and it gives recommendations for a standardised documentation of findings. Additionally, it proposes recommendations for intima-media thickness measurement and for classifying atherosclerotic plaques with B-mode ultrasonography. Moreover, criteria for the diagnosis of in-stent stenoses, vertebral artery dissections and subclavian steal syndrome are provided.


Assuntos
Doenças das Artérias Carótidas , Estenose das Carótidas , Humanos , Espessura Intima-Media Carotídea , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia , Estenose das Carótidas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem
10.
Ann Vasc Surg ; 98: 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37392855

RESUMO

BACKGROUND: Carotid artery stenting (CAS) versus carotid endarterectomy (CEA) is well issue known, but the purpose of this study is to compare CAS versus CEA in terms of asymptomatic Diffusion-weighted magnetic resonance imaging (DW-MRI) demonstrated microembolic scattering of infarction and neuropsychological assessment impairment. METHODS: We performed a prospective, observational, cohort study on 211 consecutive carotid revascularizations at our institution. Patients were divided into 2 different cohorts: CEA was performed in n = 116 patients (Group A); CAS was performed in n = 95 (Group B). Adverse events were collected at 30 days and 6 months postoperative. Differences in terms of DW-MRI demonstrated microembolic scattering of infarction were analyzed and considered significative for P ≤ 0.05. Secondary objectives were: major and minor stroke, neuropsychological assessment impairment, death, myocardial infarction (MI). RESULTS: CEA was associated with a significative decreased rate of asymptomatic DW-MRI demonstrated microembolic scattering of infarction (13.8% vs. 51%; P = 0.0001) and of 6 months neuropsychological assessments impairment (0.8 vs. 7.4) (P = 0.04) in asymptomatic patients. There was no significant difference between 2 groups in terms of comorbidities. Stroke rates were similar at 30 days (1.7% CEA vs. 4.1% CAS) and 6 months (2.6% CEA vs. 5.3% CAS P = 0.32). There were no differences in terms of central neurological events, death, transient ischemic attack, MI between the groups. The composite end point of stroke/death/MI at 6 months postoperatively was 2.6% vs. 6.3% (P = 0.19). CONCLUSIONS: According to these results, CEA achieved better outcomes compared to patients treated by CAS with distal filter in terms of asymptomatic microembolic event and impairment National Institutes of Health Stroke Scale scale and neuropsychological assessments. Limitations of the study lead to limited conclusions only in the specific population and not generalized. Further, comparative randomized studies are warranted.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Imagem de Difusão por Ressonância Magnética , Estudos Prospectivos , Estudos de Coortes , Neuroproteção , Fatores de Risco , Stents , Resultado do Tratamento , Fatores de Tempo , Acidente Vascular Cerebral/etiologia , Artérias Carótidas , Infarto do Miocárdio/etiologia , Medição de Risco
11.
Cardiovasc Eng Technol ; 14(5): 694-712, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37723333

RESUMO

PURPOSE: Worldwide, cardiovascular disease is the leading cause of hospitalization and death. Recently, the use of magnetizable nanoparticles for medical drug delivery has received much attention for potential treatment of both cancer and cardiovascular disease. However, proper understanding of the interacting magnetic field forces and the hydrodynamics of blood flow is needed for effective implementation. This paper presents the computational results of simulated implant assisted medical drug targeting (IA-MDT) via induced magnetism intended for administering patient specific doses of therapeutic agents to specific sites in the cardiovascular system. The drug delivery scheme presented in this paper functions via placement of a faintly magnetizable stent at a diseased location in the carotid artery, followed by delivery of magnetically susceptible drug carriers guided by the local magnetic field. Using this method, the magnetic stent can apply high localized magnetic field gradients within the diseased artery, while only exposing the neighboring tissues, arteries, and organs to a modest magnetic field. The localized field gradients also produce the forces needed to attract and hold drug-containing magnetic nanoparticles at the implant site for delivering therapeutic agents to treat in-stent restenosis. METHODS: The multi-physics computational model used in this work is from our previous work and has been slightly modified for the case scenario presented in this paper. The computational model is used to analyze pulsatile blood flow, particle motion, and particle capture efficiency in a magnetic stented region using the magnetic properties of magnetite (Fe3O4) and equations describing the magnetic forces acting on particles produced by an external cylindrical electromagnetic coil. The electromagnetic coil produces a uniform magnetic field in the computational arterial flow model domain, while both the particles and the implanted stent are paramagnetic. A Eulerian-Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of particles under the influence of a range of magnetic field strengths (Br = 2T, 4T, 6T, and 8T). Particle diameter sizes of 10 nm-4 µm in diameter were evaluated. Two dimensionless numbers were evaluated in this work to characterize relative effects of Brownian motion (BM), magnetic force induced particle motion, and convective blood flow on particle motion. RESULTS: The computational simulations demonstrate that the greatest particle capture efficiency results for particle diameters within the micron range of 0.7-4 µm, specifically in regions where flow separation and vortices are at a minimum. Similar to our previous work (which did not involve the use of a magnetic stent), it was also observed that the capture efficiency of particles decreases substantially with particle diameter, especially in the superparamagnetic regime. Contrary to our previous work, using a magnetic stent tripled the capture efficiency of superparamagnetic particles. The highest capture efficiency observed for superparamagnetic particles was 78% with an 8 T magnetic field strength and 65% with a 2 T magnetic field strength when analyzing 100 nm particles. For 10 nm particles and an 8 T magnetic field strength, the particle capture efficiency was 55% and for a 2 T magnetic field strength the particle capture efficiency was observed to be 43%. Furthermore, it was found that larger magnetic field strengths, large particle diameter sizes (1 µm and above), and slower blood flow velocity improves the particle capture efficiency. The distribution of captured particles on the vessel wall along the axial and azimuthal directions is also discussed. Results for captured particles on the vessel wall along the axial flow direction showed that the particle density decreased along the axial direction, especially after the stented region. For the entrance section of the stented region, the captured particle density distribution along the axial direction is large, corresponding to the center-symmetrical distribution of the magnetic force in that section. CONCLUSION: The simulation results presented in this work have shown to yield favorable capture efficiencies for micron range particles and superparamagnetic particles using magnetized implants such as the stent discussed in this work. The results presented in this work justify further investigation of MDT as a treatment technique for cardiovascular disease.


Assuntos
Doenças Cardiovasculares , Nanopartículas de Magnetita , Humanos , Artérias Carótidas , Sistemas de Liberação de Medicamentos/métodos , Campos Magnéticos , Simulação por Computador
12.
Am J Physiol Heart Circ Physiol ; 325(6): H1290-H1303, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37737734

RESUMO

Vascular aging (VA) involves structural and functional changes in blood vessels that contribute to cardiovascular disease. Several noninvasive pulse wave (PW) indices have been proposed to assess the arterial stiffness component of VA in the clinic and daily life. This study investigated 19 of these indices, identified in recent review articles on VA, by using a database comprising 3,837 virtual healthy subjects aged 25-75 yr, each with unique PW signals simulated under various levels of artificial noise to mimic real measurement errors. For each subject, VA indices were calculated from filtered PW signals and compared with the precise theoretical value of aortic Young's modulus (EAo). In silico PW indices showed age-related changes that align with in vivo population studies. The cardio-ankle vascular index (CAVI) and all pulse wave velocity (PWV) indices showed strong linear correlations with EAo (Pearson's rp > 0.95). Carotid distensibility showed a strong negative nonlinear correlation (Spearman's rs < -0.99). CAVI and distensibility exhibited greater resilience to noise compared with PWV indices. Blood pressure-related indices and photoplethysmography (PPG)-based indices showed weaker correlations with EAo (rp and rs < 0.89, |rp| and |rs| < 0.84, respectively). Overall, blood pressure-related indices were confounded by more cardiovascular properties (heart rate, stroke volume, duration of systole, large artery diameter, and/or peripheral vascular resistance) compared with other studied indices, and PPG-based indices were most affected by noise. In conclusion, carotid-femoral PWV, CAVI and carotid distensibility emerged as the superior clinical VA indicators, with a strong EAo correlation and noise resilience. PPG-based indices showed potential for daily VA monitoring under minimized noise disturbances.NEW & NOTEWORTHY For the first time, 19 noninvasive pulse wave indices for assessing vascular aging were examined together in a single database of nearly 4,000 subjects aged 25-75 yr. The dataset contained precise values of the aortic Young's modulus and other hemodynamic measures for each subject, which enabled us to test each index's ability to measure changes in aortic stiffness while accounting for confounding factors and measurement errors. The study provides freely available tools for analyzing these and additional indices.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Humanos , Envelhecimento/fisiologia , Hemodinâmica , Aorta , Artérias Carótidas , Rigidez Vascular/fisiologia
13.
Geroscience ; 45(6): 3333-3357, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37599343

RESUMO

Unhealthy vascular aging promotes atherogenesis, which may lead to significant internal carotid artery stenosis (CAS) in 5 to 7.5% of older adults. The pathogenic factors that promote accelerated vascular aging and CAS also affect the downstream portion of the cerebral microcirculation in these patients. Primary treatments of significant CAS are eversion endarterectomy or endarterectomy with patch plasty. Factors that determine adequate hemodynamic compensation and thereby the clinical consequences of CAS as well as medical and surgical complications of carotid reconstruction surgery likely involve the anatomy of the circle of Willis (CoW), the magnitude of compensatory inter-hemispheric blood flow, and the effectiveness of cerebral microcirculatory blood flow autoregulation. This study aimed to test two hypotheses based on this theory. First, we hypothesized that patients with symptomatic and asymptomatic CAS would exhibit differences in autoregulatory function and inter-hemispheric blood flow. Second, we predicted that anatomically compromised CoW would associate with impaired inter-hemispheric blood flow compensation. We enrolled older adults with symptomatic or asymptomatic internal CAS (>70% NASCET criteria; n = 46) and assessed CoW integrity by CT angiography. We evaluated transient hyperemic responses in the middle cerebral arteries (MCA) after common carotid artery compression (CCC; 10 s) by transcranial Doppler sonography (TCD). We compared parameters reflecting autoregulatory function (e.g., transient hyperemic response ratio [THRR], return to baseline time [RTB], changes of vascular resistance) and inter-hemispheric blood flow (residual blood flow velocity). Our findings revealed that CAS was associated with impaired cerebral vascular reactivity. However, we did not observe significant differences in autoregulatory function or inter-hemispheric blood flow between patients with symptomatic and asymptomatic CAS. Moreover, anatomically compromised CoW did not significantly affect these parameters. Notably, we observed an inverse correlation between RTB and THRR, and 49% of CAS patients exhibited a delayed THRR, which associated with decreased inter-hemispheric blood flow. Future studies should investigate how TCD-based evaluation of autoregulatory function and inter-hemispheric blood flow can be used to optimize surgical techniques and patient selection for internal carotid artery revascularization.


Assuntos
Estenose das Carótidas , Hiperemia , Humanos , Idoso , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Ultrassonografia Doppler Transcraniana , Microcirculação , Artérias Carótidas , Artéria Carótida Primitiva , Hemodinâmica
14.
Sensors (Basel) ; 23(13)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37447671

RESUMO

Artery stiffness is a risk factor for cardiovascular disease (CVD). The measurement of pulse wave velocity (PWV) between the carotid artery and the femoral artery (cfPWV) is considered the gold standard in the assessment of arterial stiffness. A relationship between cfPWV and regional PWV has not been established. The aim of this study was to evaluate the influence of gender on arterial stiffness measured centrally and regionally in the geriatric population. The central PWV was assessed by a SphygmoCor XCEL, and the regional PWV was assessed by a new device through the photoplethysmographic measurement of multi-site arterial pulse wave velocity (MPPT). The study group included 118 patients (35 males and 83 females; mean age 77.2 ± 8.1 years). Men were characterized by statistically significantly higher values of cfPWV than women (cfPWV 10.52 m/s vs. 9.36 m/s; p = 0.001). In the measurement of regional PWV values using MPPT, no such relationship was found. Gender groups did not statistically differ in the distribution of atherosclerosis risk factors. cfPWV appears to be more accurate than regional PWV in assessing arterial stiffness in the geriatric population.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artérias Carótidas , Artéria Femoral , Fatores de Risco
15.
Ann Surg ; 278(4): 559-567, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37436847

RESUMO

OBJECTIVE: Carotid endarterectomy (CEA) remains the gold standard procedure for carotid revascularization. Transfemoral carotid artery stenting (TFCAS) was introduced as a minimally invasive alternative procedure in patients who are at high risk for surgery. However, TFCAS was associated with an increased risk of stroke and death compared to CEA. BACKGROUND: Transcarotid artery revascularization (TCAR) has outperformed TFCAS in several prior studies and has shown similar perioperative and 1-year outcomes compared with CEA. We aimed to compare the 1-year and 3-year outcomes of TCAR versus CEA in the Vascular Quality Initiative (VQI)-Medicare-Linked [Vascular Implant Surveillance and Interventional Outcomes Network (VISION)] database. METHODS: The VISION database was queried for all patients undergoing CEA and TCAR between September 2016 to December 2019. The primary outcome was 1-year and 3-year survival. One-to-one propensity-score matching (PSM) without replacement was used to produce 2 well-matched cohorts. Kaplan-Meier estimates, and Cox regression was used for analyses. Exploratory analyses compared stroke rates using claims-based algorithms for comparison. RESULTS: A total of 43,714 patients underwent CEA and 8089 patients underwent TCAR during the study period. Patients in the TCAR cohort were older and were more likely to have severe comorbidities. PSM produced two well-matched cohorts of 7351 pairs of TCAR and CEA. In the matched cohorts, there were no differences in 1-year death [hazard ratio (HR)=1.13; 95% CI, 0.99-1.30; P =0.065]. At 3-years, TCAR was associated with slight increased risk of death (HR=1.16; 95% CI, 1.04-1.30; P =0.008). When stratifying by initial symptomatic presentation, the increased 3-year death associated with TCAR persisted only in symptomatic patients (HR=1.33; 95% CI, 1.08-1.63; P =0.008). Exploratory analyses of postoperative stroke rates using administrative sources suggested that validated measures of claims-based stroke ascertainment are necessary. CONCLUSIONS: In this large multi-institutional PSM analysis with robust Medicare-linked follow-up for survival analysis, the rate of death at 1 year was similar in TCAR and CEA regardless of symptomatic status. The slight increase in the risk of 3-year death in symptomatic patients undergoing TCAR is likely confounded by more severe comorbidities despite matching. A randomized controlled trial comparing TCAR to CEA is necessary to further determine the role of TCAR in standard-risk patients requiring carotid revascularization.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Idoso , Estados Unidos/epidemiologia , Endarterectomia das Carótidas/efeitos adversos , Estenose das Carótidas/complicações , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Medição de Risco , Resultado do Tratamento , Stents/efeitos adversos , Medicare , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Artérias Carótidas , Estudos Retrospectivos
16.
Med Phys ; 50(11): 6857-6863, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37337456

RESUMO

BACKGROUND: Stroke is closely related to carotid atherosclerotic plaques, which tend to occur in specific parts of the arteries, especially at the bifurcations, and are considered to be caused by biomechanical factors. Quantitative analysis of hemodynamic stress characteristics of the carotid sinus in vivo provides a mechanical basis for the development of atherosclerotic plaque in the carotid sinus. Previous studies found that ultrasound (US) contrast agent microbubbles would vibrate nonlinearly under the excitation of sound pressure, generating subharmonics (transmission fundamental frequency, i.e., f0 and subharmonic frequency at f0 /2), which have the highest sensitivity to pressure changes and exhibit an inverse linear relationship with environmental pressure. PURPOSE: This study employed subharmonic aided pressure estimation (SHAPE) technology to reflect carotid artery hydrodynamic characteristics in the carotid lumen. METHODS: From May 2021 to December 2021, this prospective study reviewed a total of 26 normal carotid arteries of 13 participants, all of whom received bilateral carotid artery routine US and SHAPE US examinations. During this study, the lumen of the bilateral distal segment of the common carotid artery (Distal-CCA), carotid artery bifurcation (CAB), and carotid bulb (CB) were scanned section by section from bottom to top in longitudinal and transverse sections. Subsequently, the subharmonic amplitudes in the lumen of normal carotid arteries were collected and analyzed. RESULTS: This study found that the amplitude of subharmonic amplitude in the carotid was distributed unevenly, with the amplitudes of subharmonic at the CAB being higher. Specifically, the subharmonic gradient of the carotid artery bifurcation apex plane was maximum (9.72 ± 4.31 dB), while the average subharmonic amplitude of the outer lateral layer of the carotid artery was higher (-56.40 ± 6.31 dB) (p < 0.001). CONCLUSION: The SHAPE technique is capable of indirectly reflecting the pressure changes of vascular system tissues, which may provide a new monitoring method for evaluating mechanical characteristics obviating invasion.


Assuntos
Microbolhas , Placa Aterosclerótica , Humanos , Estudos Prospectivos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Artéria Carótida Primitiva , Meios de Contraste
17.
J Hypertens ; 41(8): 1313-1322, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37260278

RESUMO

BACKGROUND: Estimated pulse wave velocity (ePWV) has been proposed as a potential approach to assess carotid-femoral pulse wave velocity (cfPWV). However, the potential ability of ePWV to predict all-cause and cause-specific mortality in the population group with hypertension remains unresolved. METHODS: We conducted a prospective cohort study using the data of 14 044 adults (age ≥18 years) from the National Health and Nutrition Examination Survey (NHANES) from 1999 to 2014, and followed this cohort until the end of December 2019. ePWV was calculated by using a regression equation for age and mean blood pressure (MBP), derived by the Arterial Stiffness Collaborative Group. RESULTS: The weighted mean age of the 14 044 adults included was 54.79 years; 49.42% of all participants were men. During the median follow-up period of 11 years, 3795 deaths were recorded. In the fully adjusted cox regression model, each 1 m/s increase in ePWV was associated with an increased risk of 56% [hazard ratio 1.61; 95% confidence interval (CI) 1.49-1.64] risk for all-cause mortality. Every 1 m/s increase in ePWV resulted in an increased risk of mortality from cardiovascular disease, cerebrovascular disease, respiratory disease, Alzheimer's disease, accidents, cancer, influenza and pneumonia by 60, 70, 47, 118, 73, 41 and 103%, respectively. ePWV has a robust predictive value for 5- and 10-year all-cause mortality in the hypertensive population with AUCs of 0.749 and 0.741, respectively. CONCLUSION: Elevated ePWV is positively correlated with all-cause mortality and most cause-specific mortalities, independent of traditional risk factors. Moreover, ePWV demonstrates high accuracy in predicting 5-year and 10-year all-cause mortality, outperforming Framingham Risk Score.


Assuntos
Hipertensão , Rigidez Vascular , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Adolescente , Feminino , Inquéritos Nutricionais , Causas de Morte , Estudos Prospectivos , Análise de Onda de Pulso , Artérias Carótidas , Fatores de Risco , Rigidez Vascular/fisiologia , Pressão Sanguínea/fisiologia
18.
Comput Med Imaging Graph ; 107: 102246, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37210966

RESUMO

Ultrasonography is one of the main imaging methods for monitoring and diagnosing atherosclerosis due to its non-invasiveness and low-cost. Automatic differentiation of carotid plaque fibrous cap integrity by using multi-modal ultrasound videos has significant diagnostic and prognostic value for cardiovascular and cerebrovascular disease patients. However, the task faces several challenges, including high variation in plaque location and shape, the absence of analysis mechanism focusing on fibrous cap, the lack of effective mechanism to capture the relevance among multi-modal data for feature fusion and selection, etc. To overcome these challenges, we propose a new target boundary and perfusion feature guided video analysis network (BP-Net) based on conventional B-mode ultrasound and contrast-enhanced ultrasound videos for assessing the integrity of fibrous cap. Based on our previously proposed plaque auto-tracking network, in our BP-Net, we further introduce the plaque edge attention module and reverse mechanism to focus the dual video analysis on the fiber cap of plaques. Moreover, to fully explore the rich information on the fibrous cap and inside/outside of the plaque, we propose a feature fusion module for B-mode and contrast video to filter out the most valuable features for fibrous cap integrity assessment. Finally, multi-head convolution attention is proposed and embedded into transformer-based network, which captures semantic features and global context information to obtain accurate evaluation of fibrous caps integrity. The experimental results demonstrate that the proposed method has high accuracy and generalizability with an accuracy of 92.35% and an AUC of 0.935, which outperforms than the state-of-the-art deep learning based methods. A series of comprehensive ablation studies suggest the effectiveness of each proposed component and show great potential in clinical application.


Assuntos
Placa Aterosclerótica , Humanos , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia/métodos , Prognóstico , Perfusão
19.
Ultrasound Med Biol ; 49(7): 1595-1601, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37088605

RESUMO

OBJECTIVE: The aim of this study was to explore the value of contrast-enhanced ultrasound (CEUS) combined with 2-D strain imaging in evaluating carotid plaque vulnerability and the correlations among CEUS perfusion parameters, strain parameters and histopathological findings in different plaque segments. METHODS: Patients with carotid artery stenosis who underwent carotid endarterectomy (CEA) at the First Affiliated Hospital of Xinjiang Medical University from September 2020 to June 2021 underwent preoperative carotid artery 2-D ultrasonography and CEUS. The plaques were divided into three segments: the proximal end of the shoulder, central cap and distal end of the shoulder. The peak intensity (PI) value and strain rate parameters of the regions of interest were analyzed. Plaques were divided into a stable group (8 cases) and an unstable group (19 cases). The microvascular density (MVD) and vascular endothelial growth factor (VEGF) expression of each patch in the unstable group were analyzed. RESULTS: The peak strain during the systolic period in each plaque segment in both groups showed the following pattern: proximal end shoulder > distal end shoulder > top (p < 0.05). The PI value for CEUS is also represented. In the unstable group, the PI values of each segment of the plaque were positively correlated with the MVD, near-center PI value and VEGF average optical density value. The average optical density of each segment was positively correlated with the MVD (p < 0.05). There were positive correlations between the PI values of the proximal and distal shoulder and the strain values (p < 0.05), and the MVD value of each segment, VEGF value and strain value were positively correlated (p < 0.05). CONCLUSION: PI and the pathological tissue components represented by CEUS were positively correlated with the mechanical parameters of the plaque along the long axis. There may be overlap between the high shear stress area of the plaque and the neovascular aggregation area, and the combination of the two has certain significance for assessing the vulnerability of the plaque.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Placa Aterosclerótica , Humanos , Fator A de Crescimento do Endotélio Vascular , Meios de Contraste , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Ultrassonografia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Neovascularização Patológica
20.
Endokrynol Pol ; 74(1): 67-73, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36847723

RESUMO

INTRODUCTION: Normocalcaemic hyperparathyroidism is a condition first defined in 2008, characterized by normal serum calcium and high parathormone levels. Although normocalcaemic hyperparathyroidism is considered to have a milder clinical picture compared to asymptomatic primary hyperparathyroidism, recent studies have shown that it may be associated with osteoporosis, insulin resistance, metabolic syndrome, and cardiovascular risk factors. Considering that normocalcaemic hyperparathyroidism may pose a cardiovascular risk in the setting of carotid atherosclerosis, we sought to examine the structural features of the carotid artery in patients with normocalcaemic hyperparathyroidism compared to a control group. MATERIAL AND METHODS: After excluding patients with hypertension, diabetes, and dyslipidaemia (other factors contributing to atherosclerosis), 37 (32 females, 5 males) patients with normocalcaemic hyperparathyroidism with a mean age of 51.2 ± 8 (min: 32, max: 66) years and 40 controls (31 females, 9 males) with a mean age of 49.3 ± 7.5 (min: 34, max: 64) years with normal serum albumin-corrected calcium and parathyroid hormone levels were included in the study. Structural features of the carotid artery including intima-media thickness (mean and maximum), lumen diameter, and the presence of plaque were assessed using B-mode ultrasound. RESULTS: On ANCOVA analysis corrected for atherosclerotic factors (body mass index, waist circumference, fasting plasma glucose, serum cholesterol, lipid, and blood pressure), greater mean intima-media thickness was found in patients with normocalcaemic hyperparathyroidism than in controls (0.65 mm vs. 0.59 mm, respectively) (p = 0.023). Maximum carotid intima-media thickness was also greater in patients with normocalcaemic hyperparathyroidism compared to controls (0.80 mm vs. 0.75 mm, respectively) (p = 0.044). The study groups did not show a significant difference in lumen diameter and the presence of carotid plaque. In addition, a negative correlation was found between parathormone (PTH) level and lumen diameter. CONCLUSION: The findings of this study show that as with asymptomatic primary hyperparathyroidism, normocalcaemic hyperparathyroidism may be associated with increased cardiovascular risk by predisposing to atherosclerosis.


Assuntos
Aterosclerose , Hiperparatireoidismo Primário , Feminino , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Espessura Intima-Media Carotídea , Cálcio , Hiperparatireoidismo Primário/complicações , Hiperparatireoidismo Primário/diagnóstico por imagem , Artérias Carótidas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA