Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Haemophilia ; 30(1): 204-213, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38082545

RESUMO

INTRODUCTION: In patients with haemophilia, repeated bleeding in large joints leads to chronic haemophilic arthropathy, a rare disease that can be managed surgically with ankle arthrodesis or with total ankle replacement (TAR). TAR has been reported to provide good surgical results in the medium/long-term and allow preservation of joint mobility but the medical therapeutic management of the patients has not been described. AIM: To describe the medical therapeutic management of TAR. METHODS: All patients with haemophilia A/B, with haemophilic ankle arthropathy, and who underwent TAR between April 2006 and October 2019 were retrospectively included. Factor consumption, perioperative and early complications, volume of blood lost, and orthopaedic data were collected. RESULTS: A total of 25 patients underwent 29 TAR (mean age was 44.7 years [range: 26-65]). In the 17 patients with HA without history of anti-FVIII inhibitor, the mean ± SD consumption the day of surgery was 116 ± 16 UI/kg when clotting factors were administered by continuous infusion, 106 ± 13 UI/kg when SHL factors were administered by bolus infusion, and 75 ± 22 UI/kg when EHL factors were administered by bolus infusion. During hospitalisation, the mean factor cost was €38,073 (83.7% of the total cost of surgery). Mean blood loss was significantly lower in patients treated with tranexamic acid (164 mL, range: 40-300) than in those not (300 mL, range: 70-800; p = .01). Six patients had haematoma. The 10-year survival free of any prosthesis removal/arthrodesis was estimated to be 92.2% (95% CI [83; 100]). CONCLUSION: The medical therapeutic management of TAR is complex, carried out by a multidisciplinary team but effective in avoiding the occurrence of complications.


Assuntos
Artrite , Artroplastia de Substituição do Tornozelo , Hemofilia A , Artropatias , Humanos , Adulto , Artroplastia de Substituição do Tornozelo/métodos , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Tornozelo/cirurgia , Hemofilia A/complicações , Hemofilia A/cirurgia , Artropatias/complicações , Artrite/complicações , Artrodese
2.
Skeletal Radiol ; 53(4): 733-739, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37857750

RESUMO

OBJECTIVE: To determine T2* normal reference values for anterior talofibular ligament (ATFL) and to investigate the feasibility of the quantitative ATFL quality evaluation in chronic lateral ankle instability (CLAI) using T2* values. MATERIALS AND METHODS: This study enrolled 15 patients with CLAI and 30 healthy volunteers. The entire ATFL T2* values from the MRI T2* mapping were measured. The prediction equation (variables: age, height, and weight) in a multiple linear regression model was used to calculate the T2* normal reference value in the healthy group. T2* ratio was defined as the ratio of the actual T2* value of the patient's ATFL to the normal reference value for each patient. A Telos device was used to measure the talar tilt angle (TTA) from the stress radiograph. RESULTS: T2* values of ATFL in the healthy and CLAI groups were 10.82 ± 1.84 ms and 14.36 ± 4.30 ms, respectively, which are significantly higher in the CLAI group (P < 0.05). The prediction equation of the normal reference T2* value was [14.9 + 0.14 × age (years) - 4.7 × height (m) - 0.03 × weight (kg)] (R2 = 0.65, P < 0.0001). A significant positive correlation was found between the T2* ratio and TTA (r = 0.66, P = 0.007). CONCLUSION: MRI T2* values in patients with CLAI were higher than those in healthy participants, and the T2* ratio correlated with TTA, suggesting that T2* values are promising for quantitative assessment of ATFL quality preoperatively.


Assuntos
Traumatismos do Tornozelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Tornozelo , Traumatismos do Tornozelo/cirurgia , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Ligamentos Laterais do Tornozelo/cirurgia , Imageamento por Ressonância Magnética/métodos , Instabilidade Articular/cirurgia
3.
Bone Joint J ; 106-B(1): 46-52, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38160692

RESUMO

Aims: Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods: This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results: The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative survival rates of the revised ankles were 81% (95% confidence interval (CI) 74% to 88%), 74% (65% to 82%), and 70% (61% to 79%) at five, ten, and 15 years, respectively. Comorbidities prior to primary TAA, aseptic loosening, instability, or grafting of cysts were found to be the most common risk factors for secondary revision. The median value for preoperative pain, as assessed using the visual analogue scale, declined from 6 (interquartile range (IQR) 5 to 8) to 2 (IQR 0 to 5) (p < 0.001) and the mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 43 (SD 17) preoperatively to 70 (SD 20) (p < 0.001) at last follow-up. Conclusion: Revision TAA offers acceptable survival rates after 15 years; it therefore offers a valuable option for treatment of implant failure in carefully selected cases. Although patient-reported outcomes improve substantially, the degree of improvement reported following primary TAA is not achieved.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Humanos , Tornozelo , Estudos Retrospectivos , Osteoartrite/cirurgia , Falha de Prótese , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Medição de Risco , Reoperação , Resultado do Tratamento
4.
Injury ; 55(2): 111037, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38142626

RESUMO

BACKGROUND: Patient factors are known to contribute to decision making and treatment of ankle fractures. The presence of poor baseline mobility, diabetes, neuropathy, alcoholism, cognitive impairment, inflammatory arthritis or polytrauma can result in a higher risk of failure or complications. Limited evidence is available on the optimum management for this challenging cohort of patients herein described as complex ankle fractures. This UK multicentre study assessed and evaluated the epidemiology of ankle fractures complicated by significant comorbidity and patient factors and use of specialist surgical techniques such as hindfoot nails (HFN) / tibiotalarcalcaneal (TCC) nails and enhanced open reduction and internal fixation (ORIF). PATIENTS AND METHODS: A UK-wide collaborative study was performed of adult distal AO43/AO44 fractures, associated with 1 or more of the patient factors listed above. Primary outcomes included patient demographics, comorbidities, surgical technique and implants. Secondary outcomes included surgical complications and early post-operative weight bearing instructions. Statistical analysis was performed to assess patient and fracture characteristics on outcome, including propensity matching. RESULTS: One-thousand three hundred and sixty patients, with at least one of the above complex factors, from 56 centres were included with a mean age of 53.1 years. 90.2% (1227) patients underwent primary fixation which included 78.9% (1073) standard open reduction internal fixations (ORIF), 3.25% (43) extended ORIF and 8.1% (111) primary HFN / TCC. Overall wound complications and thromboembolic events were similar in the hindfoot nail group and the ORIF group (11.7% vs 10.7%). Wound complications were greater in diabetic patients versus non-diabetic patients independent of fixation method (15.8% vs 9.0%). After propensity matching for comorbidities and fracture type, overall complications were lower in the hindfoot nail (11.8%) and extended ORIF groups (16.7%), than the standard ORIF group (18.6%). CONCLUSION: Only a minority of complex ankle fractures are treated with specialised techniques (HFN/TCC or extended ORIF). Though more commonly used in older and frail patients their perceived advantages are often negated by a reluctance to bear weight early. These techniques demonstrated a better complication profile to standard ORIF but hindfoot nail with joint preparation for fusion was associated with more complications than hindfoot nail for fixation. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas do Tornozelo , Adulto , Humanos , Idoso , Pessoa de Meia-Idade , Fraturas do Tornozelo/epidemiologia , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/métodos , Articulação do Tornozelo/cirurgia , Redução Aberta/métodos , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos
5.
Foot Ankle Clin ; 28(3): 463-492, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37536814

RESUMO

Total ankle arthroplasty (TAA) is an effective alternative for treating patients with end-stage ankle degeneration, improving mobility, and providing pain relief. Implant survivorship is constantly improving; however, complications occur. Many causes of pain and dysfunction after total ankle arthroplasty can be diagnosed accurately with clinical examination, laboratory, radiography, and computer tomography. However, when there are no or inconclusive imaging findings, magnetic resonance imaging (MRI) is highly accurate in identifying and characterizing bone resorption, osteolysis, infection, osseous stress reactions, nondisplaced fractures, polyethylene damage, nerve injuries and neuropathies, as well as tendon and ligament tears. Multiple vendors offer effective, clinically available MRI techniques for metal artifact reduction MRI of total ankle arthroplasty. This article reviews the MRI appearances of common TAA implant systems, clinically available techniques and protocols for metal artifact reduction MRI of TAA implants, and the MRI appearances of a broad spectrum of TAA-related complications.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Humanos , Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Imageamento por Ressonância Magnética/métodos , Dor/cirurgia
6.
Foot Ankle Clin ; 28(2): 345-354, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37137628

RESUMO

Lateral ankle ligament complex injuries are most commonly managed nonoperatively. If no improvements have been made following conservative management, surgical intervention is warranted. Concerns have been raised regarding complication rates following open and traditional arthroscopic anatomical repair. In-office needle arthroscopic anterior talo-fibular ligament repair provides a minimally invasive arthroscopic approach to the diagnosis and treatment of chronic lateral ankle instability. The limited soft tissue trauma facilitates rapid return to daily and sporting activities making this an attractive alternative approach to lateral ankle ligament complex injuries.


Assuntos
Traumatismos do Tornozelo , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Entorses e Distensões , Humanos , Articulação do Tornozelo/cirurgia , Artroscopia , Ligamentos Laterais do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico , Traumatismos do Tornozelo/cirurgia , Entorses e Distensões/diagnóstico , Entorses e Distensões/cirurgia , Instabilidade Articular/diagnóstico , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia
7.
Foot Ankle Surg ; 29(1): 67-71, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36202727

RESUMO

BACKGROUND: While the lateral hook test (LHT) has been widely used to arthroscopically evaluate syndesmotic instability in the coronal plane, it is unclear whether the angulation of the applied force has any impact on the degree of instability. We aimed to determine if changing the direction of the force applied while performing the LHT impacts the amount of coronal diastasis observed in subtle syndesmotic injuries. METHODS: In 10 cadaveric specimens, arthroscopic evaluation of the syndesmotic joint was performed by measuring anterior and posterior-third coronal plane diastasis in the intact state, and repeated after sequential transection of the 1) anterior inferior tibiofibular ligament (AITFL), 2) interosseous ligament (IOL), and 3) posterior inferior tibiofibular ligament (PITFL). In all scenarios, LHT was performed under 100 N of laterally directed force. Additionally, LHT was also performed under: 1) anterior inclination of 15 degrees and 2) posterior inclination of 15 degrees in intact and AITFL+IOL deficient state. RESULTS: Compared to the intact state, the syndesmosis became unstable after AITFL +IOL transection under laterally directed force with no angulation (p = 0.029 and 0.025 for anterior and posterior-third diastasis, respectively), which worsened with subsequent PITFL transection (p = <0.001). Moreover, there was no statistical difference in anterior and posterior-third coronal diastasis in both intact and AITFL+IOL deficient states under neutral, anterior, and posteriorly directed force (p-values ranging from 0.816 to 0.993 and 0.396-0.80, respectively). However, in AITFL+IOL transected state, posteriorly directed forces resulted in greater diastasis than neutral or anteriorly directed forces. CONCLUSIONS: Angulation of the applied force ranging from 15 degrees anteriorly to 15 degrees posteriorly during intraoperative LHT has no effect on coronal plane measurements in patients with subtle syndesmotic instability. On the other hand, posteriorly directed forces result in more sizable diastasis, potentially increasing their sensitivity. CLINICAL RELEVANCE: When arthroscopically evaluating subtle syndesmotic instability, clinicians should assess coronal diastasis with the hook angled 15 degrees posteriorly.


Assuntos
Traumatismos do Tornozelo , Artroscopia , Instabilidade Articular , Humanos , Traumatismos do Tornozelo/diagnóstico , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artroscopia/métodos , Cadáver , Instabilidade Articular/diagnóstico , Instabilidade Articular/cirurgia , Ligamentos Laterais do Tornozelo/lesões , Ligamentos Laterais do Tornozelo/cirurgia
8.
Foot Ankle Spec ; 16(3): 205-213, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34991375

RESUMO

BACKGROUND: Significant preoperative varus tibiotalar deformity was once believed to be a contraindication for total ankle arthroplasty (TAA). Our primary goal was to evaluate the influence of increasing preoperative varus tibiotalar deformity on the accuracy of final implant positioning using computed tomography (CT)-derived patient-specific guides for TAA. METHODS: Thirty-two patients with varus ankle arthritis underwent TAA using CT-derived patient-specific guides. Patients were subcategorized into varying degrees of deformity based on preoperative tibiotalar angles (0°-5° neutral, 6°-10° mild, 11°-15° moderate, and >15° severe). Postoperative weightbearing radiographs were used to measure coronal plane alignment of the tibial implant relative to the target axis determined by the preoperative CT template. Average follow-up at the time of data collection was 36.8 months. RESULTS: Average preoperative varus deformity was 6.06° (range: 0.66°-16.3°). Postoperatively, 96.9% (30/31) of patients demonstrated neutral implant alignment. Average postoperative tibial implant deviation was 1.54° (range: 0.17°-5.7°). Average coronal deviation relative to the target axis was 1.61° for the neutral group, 1.78° for the mild group, 0.94° for the moderate group, and 1.41° for the severe group (P = .256). Preoperative plans predicted 100% of tibial and talar implant sizes correctly within 1 size of actual implant size. Conclusion. Our study supports the claim that neutral postoperative TAA alignment can be obtained using CT-derived patient-specific instrumentation (PSI). Furthermore, final implant alignment accuracy with PSI does not appear to be impacted by worsening preoperative varus deformity. All but one patient (96.9%) achieved neutral postoperative alignment relative to the predicted target axis. LEVEL OF EVIDENCE: Level IV, Clinical Case Series.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Humanos , Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Tomografia Computadorizada por Raios X , Extremidade Inferior/cirurgia , Estudos Retrospectivos
9.
Arch Orthop Trauma Surg ; 143(6): 2913-2918, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35652950

RESUMO

INTRODUCTION: Contemporary studies evaluating utilization and trends of total ankle arthroplasty (TAA) and ankle fusion (AF) for tibiotalar osteoarthritis are sparse. Therefore, the purpose of this study was to utilize a nationwide administrative claims database from 2010 to 2019 to compare: (1) baseline demographics; (2) utilization, (3) in-hospital length of stay (LOS), and (4) costs of care. METHODS: Using the PearlDiver database, a retrospective query from January 1st, 2010 to December 31st, 2019 was performed for all patients who underwent TAA and AF for tibiotalar osteoarthritis. Baseline demographics, comorbidities, and geographic utilization were compared using Pearson Chi-square analyses. Linear regression was used to compare differences in procedure utilization and in-hospital LOS during the study interval. Reimbursements between the two cohorts during the study interval were compared. A p value less than 0.05 was statistically significant. RESULTS: In total, 14,248 patients underwent primary TAA (n = 5544) or AF (n = 8704). Patients undergoing AF were generally younger (< 60) with greater comorbidity burden driven by hypertension, diabetes mellitus, obesity, and tobacco use compared to TAA patients (p < 0.0001). Over the study interval, TAA utilization remained constant (912 vs 909 procedures; p = 0.807), whereas AF utilization decreased by 42.5% (1737 vs 998 procedures; p = 0.0001). Mean in-hospital LOS for patients undergoing TAA decreased (2.5 days vs. 2.0 days, p = 0.0004), while AF LOS increased (2.6 days vs. 3.5 days, p = 0.0003). Reimbursements for both procedures significantly declined over the study interval (TAA: $4559-$2156, AF: $4729-$1721; p < 0.013). CONCLUSION: TAA utilization remained constant, while AF utilization declined by 42.5% from 2010 to 2019. There was divergence in the LOS for TAA versus AF patients. Both procedures significantly declined by over 50% in reimbursements over the study interval.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Humanos , Estados Unidos , Articulação do Tornozelo/cirurgia , Tornozelo/cirurgia , Estudos Retrospectivos , Artroplastia de Substituição do Tornozelo/métodos , Osteoartrite/cirurgia , Demografia
10.
Ann Intern Med ; 175(12): 1648-1657, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36375147

RESUMO

BACKGROUND: End-stage ankle osteoarthritis causes severe pain and disability. There are no randomized trials comparing the 2 main surgical treatments: total ankle replacement (TAR) and ankle fusion (AF). OBJECTIVE: To determine which treatment is superior in terms of clinical scores and adverse events. DESIGN: A multicenter, parallel-group, open-label randomized trial. (ISRCTN registry number: 60672307). SETTING: 17 National Health Service trusts across the United Kingdom. PATIENTS: Patients with end-stage ankle osteoarthritis, aged 50 to 85 years, and suitable for either procedure. INTERVENTION: Patients were randomly assigned to TAR or AF surgical treatment. MEASUREMENTS: The primary outcome was change in Manchester-Oxford Foot Questionnaire walking/standing (MOXFQ-W/S) domain scores between baseline and 52 weeks after surgery. No blinding was possible. RESULTS: Between 6 March 2015 and 10 January 2019, a total of 303 patients were randomly assigned; mean age was 68 years, and 71% were men. Twenty-one patients withdrew before surgery, and 281 clinical scores were analyzed. At 52 weeks, the mean MOXFQ-W/S scores improved for both groups. The adjusted difference in the change in MOXFQ-W/S scores from baseline was -5.6 (95% CI, -12.5 to 1.4), showing that TAR improved more than AF, but the difference was not considered clinically or statistically significant. The number of adverse events was similar between groups (109 vs. 104), but there were more wound healing issues in the TAR group and more thromboembolic events and nonunion in the AF group. The symptomatic nonunion rate for AF was 7%. A post hoc analysis suggested superiority of fixed-bearing TAR over AF (-11.1 [CI, -19.3 to -2.9]). LIMITATION: Only 52-week data; pragmatic design creates heterogeneity of implants and surgical techniques. CONCLUSION: Both TAR and AF improve MOXFQ-W/S and had similar clinical scores and number of harms. Total ankle replacement had greater wound healing complications and nerve injuries, whereas AF had greater thromboembolism and nonunion, with a symptomatic nonunion rate of 7%. PRIMARY FUNDING SOURCE: National Institute for Health and Care Research Heath Technology Assessment Programme.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Masculino , Humanos , Idoso , Feminino , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Articulação do Tornozelo/cirurgia , Tornozelo/cirurgia , Medicina Estatal , Resultado do Tratamento , Artrodese/efeitos adversos , Artrodese/métodos
11.
Orthop Surg ; 14(8): 1808-1816, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35822619

RESUMO

OBJECTIVE: Total ankle replacement (TAR) and ankle arthrodesis (AA) are two common surgical treatment options for end-stage ankle osteoarthritis. However, few reports compare the outcomes of simultaneous TAR and contralateral AA for bilateral ankle osteoarthritis. The aim of this study was to assess changes in pain, joint range of movement (ROM), functional outcomes, patient satisfaction, and cost-effectiveness following simultaneous TAR and contralateral AA. METHODS: A retrospective study was conducted on 12 patients with bilateral end-stage ankle osteoarthritis who underwent simultaneous TAR and contralateral AA in our institution between May 2016 and August 2018, and who had a minimum of two-year follow-up data. Clinical and radiological follow-up data for all patients were collected after 4 months, 1 year and 2 years. The results were assessed clinically on a visual analogue scale (VAS) and included ROM, American Orthopedic Foot and Ankle Society (AOFAS) ankle hindfoot score, and satisfaction questionnaire. The total hospital costs of patients were also recorded. Independent sample t tests were conducted to compare continuous variables between groups. Paired sample t-tests were conducted to compare changes from the preoperative to postoperative evaluations within each group. RESULTS: Both surgical groups presented with pain reduction (P < 0.001) at the one-year postoperative session, which was generally consistent until the two-year follow-up. There was a significant increase (P < 0.001) in the mean AOFAS score postoperatively in both ankles. The functional outcomes at the one- and two-year follow-up were significantly better in patients in the TAR group than in those in the AA group (P < 0.001). Joint ROM differences were observed between the two groups after surgery (decreased ankle ROM in arthrodesis, P < 0.001; increased ankle ROM in arthroplasty, P < 0.001). The mean satisfaction score was 2 (range, 1-4) for the TAR group and 3 (range, 1-5) for the AA group. A significant difference in the satisfaction score was observed between the two groups (P = 0.036). Simultaneous TAR and contralateral AA was 34.1% less expensive than simultaneous bilateral TAR. No intraoperative complications were noted in either group. Wound healing occurred without problems within 2 weeks after surgery. No symptomatic deep venous thrombosis was found during follow-up. CONCLUSION: TAR had better patient-perceived post-operative function and preserves more anatomic sagittal plane motion compared to ankles undergoing AA. In addition, simultaneous TAR and contralateral AA are more cost-effective than simultaneous bilateral TAR, with lower costs for the average patient.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artrodese/métodos , Artroplastia de Substituição do Tornozelo/métodos , Análise Custo-Benefício , Humanos , Osteoartrite/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Foot Ankle Int ; 43(10): 1269-1276, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35837716

RESUMO

BACKGROUND: Ankle fracture displacement is an important outcome in clinical research examining the effectiveness of surgical and rehabilitation interventions. However, the assessment of displacement remains subjective without well-described or validated measurement methods. The aim of this study was to assess inter- and intrarater reliability of ankle fracture displacement radiographic measures and select measurement thresholds that differentiate displaced and acceptably reduced fractures. METHODS: Eight fellowship-trained orthopaedic surgeons evaluated a set of 26 postoperative ankle fracture radiographs on 2 occasions. Surgeons followed standardized instructions for making 5 measurements: coronal displacement (3) talar tilt (1), and sagittal displacement (1). Inter- and intraobserver interclass correlations were determined by random effects regression models. Logistic regression was used to determine the optimal sensitivity and specificity for the measurements with the highest correlation. RESULTS: Three of the 5 measures had excellent interobserver reliability (correlation coefficient > 0.75): (1) coronal plane distance between the lateral border of tibia and lateral border of talus, (2) coronal plane talar tilt, and (3) sagittal plane displacement. The threshold that best discriminated displaced from well-aligned fractures was 2 mm for coronal plane distance (sensitivity 82.1%, specificity 85.4%), 3 degrees for talar tilt (sensitivity 80.4%, specificity 82.2%), and 5 mm for sagittal plane distance (sensitivity 83.9%, specificity 84.9%). CONCLUSION: This study identified 3 reliable measures of ankle fracture displacement and determined optimal thresholds for discriminating between displaced and acceptably reduced fractures. These measurement criteria can be used for the design and conduct of clinical research studying the impact of surgical treatment and rehabilitation interventions.


Assuntos
Fraturas do Tornozelo , Tálus , Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Humanos , Reprodutibilidade dos Testes , Tálus/diagnóstico por imagem , Tálus/cirurgia
13.
Foot (Edinb) ; 51: 101874, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35461152

RESUMO

OBJECTIVES: Compare the functional outcomes of comparative studies of ankle arthrodesis (AA) and total ankle replacements (TAR). DESIGN: Systematic review using PRISMA guidelines. DATA SOURCES: Medline, Cochrane and EMBASE databases in July 2020. ELIGIBILITY CRITERIA: Studies that directly compared TAR and AA which reported patient reported outcomes measures (PROMs) of pain, function and quality of life. DATA EXTRACTION AND SYNTHESIS: Two authors independently reviewed all papers. PROMs were allocated into pain, function or quality of life domains. Two summary statistics were created to allow for analysis of the PROMs. These statistics were the mean difference in post-operative score and the mean difference in the change of score. RESULTS: 1323 papers were assessed of which 20 papers were included. 898 ankle arthrodesis and 1638 ankle replacements were evaluated. The mean follow up was 3.3 years (range 0.5-13.0 years). AA patients had a mean age of 55.7 (range 20-82) and TAR 62.5 (range 21-89). There was major heterogeneity in outcomes used. We were unable to find a significant difference between the reported change in PROMs following TAR and AA. 29.3% of PROMs and their subscores showed TAR had better outcomes, 68.7% showed no significant difference and only 2.0% showed AA to have better outcomes. CONCLUSIONS: The majority of published studies found equality in patient reported outcomes following TAR and AA although the quality of the studies was of low-level evidence. There is an urgent need for randomised controlled studies to definitively answer this important clinical question.


Assuntos
Artroplastia de Substituição do Tornozelo , Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artrodese , Humanos , Pessoa de Meia-Idade , Dor/cirurgia , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Resultado do Tratamento
14.
Foot Ankle Int ; 43(5): 609-619, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35073771

RESUMO

BACKGROUND: Periprosthetic cysts can occur in up to 95% of total ankle arthroplasties (TAA) and have been correlated with implant failure. The aim of this study was to determine the clinical and radiologic outcomes, using computed tomographic (CT) scan, after periprosthetic cyst bone grafting and assess for the minimum cyst size that should be grafted. METHODS: A retrospective review was performed of all TAA procedures performed between 2007 and 2014 (n=93). A CT scan was done to assess cyst size and operative planning. Eight patients with 9 periprosthetic cysts larger than 1.75 cm3 were grafted and specimens sent for histology. The mean time to bone grafting was 7.3 (3.8-9.5) years. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society ankle score, visual analog scale, and Self-reported Foot and Ankle Score. A CT scan was performed at follow-up to assess graft incorporation and cyst size progression. The mean time to CT scan post grafting was 3.0 (0.7-4.7) years. RESULTS: There was no implant malalignment identified and no differences in the pre- and postoperative functional scores. Preoperatively cysts had a mean volume of 8.16 (2.04-14.03) cm3. The mean percentage incorporation was 89% (69%-100%). Eight of the grafted cysts were considered successful on CT, with the ninth having 69% incorporation. Five cysts were not grafted, as they were below 1.75 cm3, and remained the same size or had minimal enlargement. CONCLUSION: The satisfactory results in this small cohort suggests that prophylactic bone grafting may extend implant survival. We recommend that periprosthetic cysts greater than 1.75 cm3 be prophylactically bone grafted, and that cysts smaller than 1.75 cm3 be monitored for progression in size. LEVEL OF EVIDENCE: Level IV, Case Series.


Assuntos
Artroplastia de Substituição do Tornozelo , Cistos , Prótese Articular , Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Transplante Ósseo , Seguimentos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Foot Ankle Spec ; 15(3): 201-208, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32830583

RESUMO

BACKGROUND: Surgical management of end-stage ankle arthritis consists of either ankle arthrodesis (AA) or total ankle replacement (TAR). The purpose of this study was to evaluate utilization trends in TAR and AA and compare cost and complications. METHODS: Medicare patients with the diagnosis of ankle arthritis were reviewed. Patients undergoing surgical intervention were split into AA and TAR groups, which were evaluated for trends as well as postoperative complications, revision rates, and procedure cost. RESULTS: A total of 673 789 patients were identified with ankle arthritis. A total of 19 120 patients underwent AA and 9059 underwent TAR. While rates of AA remained relatively constant, even decreasing, with 2080 performed in 2005 and 1823 performed in 2014, TAR rates nearly quadrupled. Average cost associated with TAR was $12559.12 compared with $6962.99 for AA (P < .001). Overall complication rates were 24.9% in the AA group with a 16.5% revision rate compared with 15.1% and 11.0%, respectively, in the TAR group (P < .001). Patients younger than 65 years had both higher complication and revision rates. DISCUSSION: TAR has become an increasingly popular option for the management of end-stage ankle arthritis. In our study, TAR demonstrated both lower revision and complication rates than AA. However, TAR represents a more expensive treatment option. LEVELS OF EVIDENCE: Level III: Retrospective comparative study.


Assuntos
Artrite , Artroplastia de Substituição do Tornozelo , Idoso , Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artrite/etiologia , Artrite/cirurgia , Artrodese/efeitos adversos , Artrodese/métodos , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Humanos , Medicare , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos/epidemiologia
16.
Iowa Orthop J ; 42(2): 36-46, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36601228

RESUMO

Background: Ankle osteoarthritis (AO) is often secondary to prior trauma and frequently presents with joint deformity. Total ankle replacement (TAR) has been shown as a viable surgical option to reduce pain, improve function, and preserve ankle joint range of motion. The standard TAR uses an anterior approach, but recently a lateral trans-fibular approach has been developed. Our aim was to determine if the lateral TAR was able to correct alignment and improve patient reported outcomes (PROs) in patients with end-stage AO. Methods: This IRB-approved, retrospective comparative study included 14 consecutive patients that underwent lateral trans-fibular approach TAR for end-stage AO. All patients had received pre-and post-operative WBCT imaging on the affected foot and ankle. Using multiplanar reconstruction of WBCT images, measures of coronal and sagittal plane ankle alignment: Foot and Ankle Offset (FAO), Talar Tilt Angle (TTA), Hindfoot Moment Arm (HMA), and Lateral Talar Station (LTS) were performed. PROs were collected pre- and postoperatively at the latest clinical follow-up. Results: All patients demonstrated a significant deformity correction in all measurements performed: FAO (7.73%-3.63%, p=0.031), HMA (10.93mm - 5.10mm, p=0.037), TTA (7.9o-1.5o, p=0.003), and LTS (5.25mm-2.83mm, p=0.018). Four of the PROs measured exhibited significant improvement postoperatively, the Tampa Scale for Kinesiophobia (TSK) (42.7-34.5, p=0.012), PRO-MIS Global Physical Health (46.1-54.5, p=0.011), EFAS (5-10.3, p=0.004), and FAAM Daily Living (60.5-79.7, p=0.04). Multivariate analysis assessing the influence of deformity correction in the improvements of PROs found that PROMIS Global Physical Health was significantly associated with improvements in FAO and LTS, TSK associated with HMA, and FAAM Daily Living with FAO and TTA (p<0.05). Conclusion: The results of this retrospective comparative cohort study suggest that the lateral trans-fibular TAR can correct different aspects of AO deformity. The method also impacted PROs, particularly TSK, PROMIS Global Physical Health, EFAS, and FAAM Daily Living. Direct correlation between some of the deformity correction measurements and the significantly improved PROs was found. The obtained data could help surgeons when making treatment decisions and be the base for comparative prospective studies. Level of Evidence: III.


Assuntos
Artroplastia de Substituição do Tornozelo , Osteoartrite , Humanos , Artroplastia de Substituição do Tornozelo/métodos , Tornozelo/diagnóstico por imagem , Tornozelo/cirurgia , Estudos Retrospectivos , Estudos Prospectivos , Estudos de Coortes , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Tomografia Computadorizada por Raios X , Suporte de Carga
17.
Orthop Traumatol Surg Res ; 108(7): 103133, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34706289

RESUMO

BACKGROUND: The demand for total ankle arthroplasty (TAA) and ankle arthrodesis surgery is increasing. Findings from other orthopaedic populations suggest an increasing comorbidity burden among those planned for surgery, however, data on TAA and ankle arthrodesis is limited. The goal of this study is to study the comorbidity burden for TAA and ankle arthrodesis. HYPOTHESIS: Comorbidity burden is associated with higher resource utilization for both TAA and ankle arthrodesis. PATIENTS AND METHODS: This retrospective cohort study utilized data from the nationwide Premier Healthcare Database (2006-2016) which contains inpatient claims on n=10,085 ankle arthrodesis and n=4,977 TAA procedures. Patients were categorized into Deyo-Charlson comorbidity index (DCCI) groups. Outcomes were cost of hospitalization, length of stay (LOS), total opioid utilization, discharge to a skilled nursing facility (SNF), and 30-day readmission. Mixed-effects models estimated associations between DCCI and outcomes. We report odds ratios (OR, or % change for continuous outcomes) and 95% confidence intervals (CI). RESULTS: In the TAA group, 67.9% of patients were in DCCI category 0 while 22.4%, 6.6%, and 3.1% were in the 1, 2, and >2 DCCI categories, respectively. This was 61.3%, 18.1%, 9.8% and 10.9% in the ankle arthrodesis group. The most common comorbidities were obesity, diabetes mellitus, and chronic pulmonary disease. Particularly in the ankle arthrodesis group, the proportion of patients with comorbidities has increased over time. After adjustment for relevant covariates, patients in the DCCI group >2 (compared to '0') were associated with stepwise effects of up to 77.1% (CI 70.9%; 83.6%) longer length of stay and up to 48.5% (CI 44.0%; 53.2%) higher cost of hospitalization. DISCUSSIONS: Comorbidity burden is increasing among patients undergoing ankle arthrodesis where it is associated with significantly increased resource utilization. Our data demonstrate the potential impact of patient selection, which may be crucial in optimizing preoperative status. LEVEL OF EVIDENCE: III.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Humanos , Estudos Retrospectivos , Articulação do Tornozelo/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Artrodese/métodos , Comorbidade
18.
Eur J Orthop Surg Traumatol ; 32(6): 1089-1095, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34347186

RESUMO

PURPOSE: To determine the interobserver reliability of syndesmosis assessment using intraoperative ankle mortise fluoroscopic images, with and without contralateral images. METHODS: A survey of 19 operative ankle fracture cases was administered to 17 orthopedic surgeons. Respondents were presented with fluoroscopic mortise and stress images of the ankle after fracture fixation and asked if they would fix the syndesmosis. Final fluoroscopic mortise images were then shown, and respondents were asked to assess the reduction of the syndesmosis. Six weeks later, the survey was administered again with the addition of contralateral fluoroscopic ankle mortise images. Responses were compared to a standard response agreed upon by fellowship-trained orthopedic trauma surgeons. RESULTS: Interobserver reliability for syndesmosis fixation and reduction, with and without contralateral images, was considered weak (kappa 0.48 and 0.43; mean difference 0.05, 95% confidence interval (CI) 0.01 to 0.1) and minimal (kappa 0.25 and 0.22; mean difference 0.02, CI - 0.02 to 0.08). With the addition of contralateral mortise images, the number of surgeons who changed their response for syndesmosis fixation and reduction quality ranged from 0% to 41% and 0% to 88%; with the number of responses matching the standard increasing for both fixation (proportional difference (PD) 7%, CI 1% to 14%) and reduction (PD 14%, CI 7% to 21%); CONCLUSIONS: Interobserver reliability of syndesmosis fixation and reduction remained weak to minimal between surgeons, with and without contralateral images. Future studies are necessary to understand the variability in surgeon responses in order to improve the intraoperative assessment and fixation of syndesmotic injuries.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Fixação de Fratura , Fixação Interna de Fraturas/métodos , Humanos , Reprodutibilidade dos Testes
19.
J Foot Ankle Surg ; 61(1): 7-11, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34244049

RESUMO

Research demonstrating improved outcomes with third-generation ankle replacement implants has resulted in increasing utilization of total ankle arthroplasty over the past 3 decades. The purpose of this study was to examine the quality and trends of clinical outcomes research being published on third-generation total ankle arthroplasty implants. Two fellowship-trained foot and ankle surgeons reviewed all peer-reviewed, Medline-indexed English-language clinical outcomes studies evaluating total ankle arthroplasty published between 2006 and 2019. Articles were assessed for study design and indicators of study quality. A total of 694 published articles were reviewed and 231 met all inclusion criteria. The majority (78%) of studies were retrospective, most of which were case series (54%) or cohorts (32%). Ten percent (10%) of studies were funded by industry and 28% did not disclose funding sources. Thirty-eight percent (38%) of studies reported a conflict of interest and 6% did not disclose whether or not there were conflicts. The average patient follow-up time across studies was 72 months. We found that although the study of outcomes with third-generation total ankle arthroplasty prostheses is steadily increasing, most studies are Level IV, retrospective case series. Some studies have disclosed industry funding and/or a conflict of interest, and a considerable number did not disclose potential funding and/or financial conflicts. Future investigators should strive to design studies with the highest quality methodology possible.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artrodese , Humanos , Avaliação de Resultados em Cuidados de Saúde , Estudos Retrospectivos , Resultado do Tratamento
20.
Foot Ankle Surg ; 28(5): 564-569, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34049803

RESUMO

BACKGROUND: Although many authors have discussed total blood loss after arthroplasty of the knee, hip, and shoulder, reports on perioperative blood loss after total ankle arthroplasty (TAA) are rare. The purpose of this study was to assess total blood loss after TAA and to identify correlated factors. METHODS: A total of 103 cases (99 patients) of TAA for end-stage ankle osteoarthritis were enrolled in this study. Perioperative total blood loss was divided into intraoperative and postoperative blood loss. The patient-related variables evaluated for total blood loss were age, sex, body mass index, American Society of Anesthesiologists Classification score, comorbidities, history of previous ankle surgery, preoperative use of anticoagulants, platelet count and prothrombin time/international normalized ratio. Operation-related variables including type of anesthesia, operation time, TAA implant, and procedures performed in addition to TAA (if any) were evaluated to analyze correlations with total blood loss. In addition, the rate of transfusions after surgery was identified, and risk factors for transfusion were statistically analyzed. RESULTS: The total blood loss was mean 795.5±351.1mL, which included 462.2±248.5mL of intraoperative blood loss and 333.2±228.6mL of postoperative blood loss. Sex, TAA implant, and additional bony procedures performed along with TAA were significantly correlated with total blood loss (p=0.039, 0.024, 0.024, respectively) but the other variables were not significant (p>0.05). Transfusions were administered for 4 cases (3.8%) but no risk factors for transfusion could be identified. CONCLUSION: The total blood loss after TAA was 795.5mL and the rate of transfusions was 3.8%. This study demonstrated that male sex, use of TAA implants with a larger cutting surface, and bony procedures performed in addition to TAA were associated with an increase in total blood loss after TAA. The findings of this study will help surgeons to better predict blood loss and make optimal surgical plans accordingly. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo , Perda Sanguínea Cirúrgica , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA