Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Steroid Biochem Mol Biol ; 212: 105917, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34010687

RESUMO

An intralaboratory study assessing assay variability and bias for determination of serum total 25-hydroxyvitamin D [25(OH)D] was conducted by the Vitamin D Standardization Program (VDSP). Thirteen assays for serum total 25(OH)D were evaluated in a single laboratory including 11 unique immunoassays and one liquid chromatography - tandem mass spectrometry (LC-MS/MS) assay. Fifty single-donor serum samples, including eight samples with high concentrations of 25(OH)D2 (> 30 nmol/L), were assigned target values for 25(OH)D2 and 25(OH)D3 using reference measurement procedures (RMP). Using four replicate measurements for each sample, the mean total percent coefficient of variation (%CV) and mean % bias from the target values were determined for each assay using the 50 single-donor samples and a 42-sample subset, which excluded 8 high 25(OH)D2 concentration samples, and compared with VDSP performance criteria of ≤ 10 % CV and ≤ ±5 % mean bias. All 12 assays achieved the performance criterion for % CV, and 9 of the 12 assays were within ≤ ±5 % mean bias. The Fujirebio Inc. assay exhibited the lowest %CV and highest percentage of individual measurements within ≤ ±5 % mean bias. Ten immunoassays exhibited changes in response due to the high 25(OH)D2 samples with Abbott, Biomérieux, DiaSorin, DIAsource, and IDS-iSYS assays having the largest deviations. The Fujirebio Inc. and Beckman Coulter assays were only minimally affected by the presence of the high 25(OH)D2 samples. Samples with high concentrations of 25(OH)D2 provided a critical performance test for immunoassays indicating that some assays may not have equal response or recovery for 25(OH)D2 and 25(OH)D3.


Assuntos
Bioensaio/normas , Imunoensaio/normas , Vitamina D/análogos & derivados , Vitaminas/sangue , Viés , Cromatografia Líquida , Humanos , Laboratórios , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Vitamina D/sangue
2.
Clin Biochem ; 87: 39-45, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33188771

RESUMO

BACKGROUND: The commutability of control materials used for external quality assessment (EQA) programs is of great importance. Evaluating the commutability of control materials is crucial to assess their suitability for EQA programs. METHODS: Forty-eight individual patient serum samples, commercial EQA samples, human serum pools (HSPs), commercially available sterile filtered charcoal stripped serum (CS) and swine serum were analyzed using the isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) comparative method and six immunoassays for progesterone. The commutability was assessed according to the EP14-A2 guideline and the difference in bias approach, respectively. RESULTS: According to the EP14-A2 guideline, HSPs and CS were commutable for all the tested immunoassays, while swine serum showed positive matrix effects in some assays. Based on the difference in bias approach, a large number of inconclusive and noncommutable results appeared. CONCLUSIONS: The commutability of the processed materials varied depending on which evaluation approach and criterion was applied. Noncommutability of the EQA materials was observed. And HSPs and CS were possible commutable candidate control materials according to the EP14-A2 guideline.


Assuntos
Bioensaio/métodos , Cromatografia Líquida/métodos , Progesterona/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Bioensaio/normas , Cromatografia Líquida/normas , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Controle de Qualidade , Padrões de Referência , Suínos , Espectrometria de Massas em Tandem/normas
4.
Bioanalysis ; 12(8): 545-559, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32352315

RESUMO

Internal standard (IS) plays an important role in LC-MS bioanalysis by compensating for the variability of the analyte of interest in bioanalytical workflow. Due to the complexity of biological sample compositions and bioanalytical processes, a certain level of IS response variability across a run or a study is anticipated. However, an extensive variability may raise doubts to the accuracy of the measured results and also suggest nonoptimal analytical method. In this current paper, recent publications and guidelines regarding IS response in LC-MS bioanalysis were thoroughly reviewed with focus on the evaluation, identification and impact assessment of 'abnormal' IS response variability. A systematic decision tree was proposed to facilitate investigation into abnormal IS response variability after each run.


Assuntos
Bioensaio/normas , Cromatografia Líquida/normas , Humanos , Padrões de Referência , Espectrometria de Massas em Tandem/normas
5.
J Infect Dis ; 220(220 Suppl 3): S116-S125, 2019 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-31593600

RESUMO

Approximately 3.6 million cases of active tuberculosis (TB) go potentially undiagnosed annually, partly due to limited access to confirmatory diagnostic tests, such as molecular assays or mycobacterial culture, in community and primary healthcare settings. This article provides guidance for TB triage test evaluations. A TB triage test is designed for use in people with TB symptoms and/or significant risk factors for TB. Triage tests are simple and low-cost tests aiming to improve ease of access and implementation (compared with confirmatory tests) and decrease the proportion of patients requiring more expensive confirmatory testing. Evaluation of triage tests should occur in settings of intended use, such as community and primary healthcare centers. Important considerations for triage test evaluation include study design, population, sample type, test throughput, use of thresholds, reference standard (ideally culture), and specimen flow. The impact of a triage test will depend heavily on issues beyond accuracy, primarily centered on implementation.


Assuntos
Bioensaio/normas , Testes Diagnósticos de Rotina/normas , Mycobacterium tuberculosis/isolamento & purificação , Guias de Prática Clínica como Assunto , Triagem/métodos , Tuberculose Pulmonar/diagnóstico , Adulto , Bioensaio/economia , Biomarcadores/sangue , Biomarcadores/urina , Hemocultura/normas , Criança , Estudos de Coortes , Estudos Transversais , Testes Diagnósticos de Rotina/economia , Humanos , Mycobacterium tuberculosis/patogenicidade , Mycobacterium tuberculosis/fisiologia , Padrões de Referência , Projetos de Pesquisa , Fatores de Risco , Sensibilidade e Especificidade , Escarro/microbiologia , Triagem/economia , Triagem/normas , Tuberculose Pulmonar/microbiologia , Tuberculose Pulmonar/fisiopatologia , Organização Mundial da Saúde
6.
BioDrugs ; 33(4): 411-422, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31190280

RESUMO

BACKGROUND: SB3 has been developed as a trastuzumab biosimilar, a therapeutic monoclonal antibody targeted to human epidermal growth factor receptor 2 (HER2), and approved by the European Commission and United States (US) Food and Drug Administration (FDA). During the developmental period of a biosimilar, setting an appropriate quality target is critical for assessing the similarity of the biosimilar product to the reference product. A stepwise approach should be taken to assessing similarity, beginning with extensive characterization of the reference product to establish the quality target. OBJECTIVE: In this study, we evaluated the similarity of SB3 to the reference product and the impact of changes in the biological profile of the reference product on similarity assessment. METHODS: Analytical similarity was assessed with defined test procedures in terms of critical quality attributes (CQAs) that could affect efficacy, potency, and safety, as well as for the non-CQAs that are related to process consistency. The quality target was established using up to 154 lots of European Union (EU)- and US-sourced Herceptin® (reference product), analyzed during the developmental period of SB3. RESULTS: Trends of the EU- and US-sourced reference product showed that the biological profile exhibited two marked changes for Fc-related attributes, and then recovered to pre-change quality level. Since the similarity range set by pre-change lots was considered most relevant, the changed lots were excluded from establishing the similarity range, which resulted in tightened acceptance criteria. As shown in the results of similarity assessment using the stringent quality target ranges, SB3 exhibits highly similar functional activities compared to the reference product in terms of both CQAs and non-CQAs. CONCLUSION: SB3 has been developed as a trastuzumab biosimilar approved in the EU and USA, and its manufacturing process is deemed to be robust and well-controlled within stringent quality target ranges.


Assuntos
Antineoplásicos Imunológicos/farmacologia , Medicamentos Biossimilares/farmacologia , Neoplasias da Mama/tratamento farmacológico , Receptor ErbB-2/antagonistas & inibidores , Trastuzumab/farmacologia , Antineoplásicos Imunológicos/uso terapêutico , Bioensaio/normas , Medicamentos Biossimilares/uso terapêutico , Neoplasias da Mama/patologia , Linhagem Celular , Linhagem Celular Tumoral , Ensaios de Seleção de Medicamentos Antitumorais/normas , Humanos , Receptor ErbB-2/metabolismo , Padrões de Referência , Trastuzumab/uso terapêutico
7.
J Environ Sci Health B ; 54(8): 655-664, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31177923

RESUMO

Little is known about the effects of polluted water bodies from Buenos Aires Province on the development of native fauna. Ecotoxicological quality of water bodies from agricultural sites was evaluated by means of standardized laboratory bioassays with embryos and larvae of the native amphibian Rhinella arenarum. The organisms were acutely and chronically exposed to surface water samples from streams of Arrecifes (A), Pergamino (P) and Salto (S) districts that represent the most important agricultural core from the region. Lethal, sublethal and genotoxic effects were assessed. Water sample from (A) caused chronic toxicity (LC50:45.35%) in embryos, followed by (S) and the water sample from (P) was not toxic. In larvae, an inversion of the toxicity pattern was found. Thus, the 504 h-LC50s were 28.12%, 39% and 61% for (S), (P) and (A), respectively. A stage-dependent sensitivity was registered, being larvae more affected than embryos. Significant genotoxic effects, estimated by micronucleus test were observed in the larvae exposed to water samples from all sites. The present study warns about environmental degradation of surface waters next to agricultural areas of Buenos Aires Province. This fact jeopardizes R. arenarum populations in this area.


Assuntos
Bufo arenarum/embriologia , Ecotoxicologia/métodos , Qualidade da Água , Animais , Argentina , Bioensaio/normas , Ecotoxicologia/normas , Embrião não Mamífero , Larva/efeitos dos fármacos , Dose Letal Mediana , Testes para Micronúcleos , Rios , Testes de Toxicidade Crônica
8.
Malar J ; 18(1): 153, 2019 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-31039788

RESUMO

BACKGROUND: Insecticide-treated net (ITN) durability, measured through physical integrity and bioefficacy, must be accurately assessed in order to plan the timely replacement of worn out nets and guide procurement of longer-lasting, cost-effective nets. World Health Organization (WHO) guidance advises that new intervention class ITNs be assessed 3 years after distribution, in experimental huts. In order to obtain information on whole-net efficacy cost-effectively and with adequate replication, a new bioassay, the Ifakara Ambient Chamber Test (I-ACT), a semi-field whole net assay baited with human host, was compared to established WHO durability testing methods. METHODS: Two experiments were conducted using pyrethroid-susceptible female adult Anopheles gambiae sensu stricto comparing bioefficacy of Olyset®, PermaNet® 2.0 and NetProtect® evaluated by I-ACT and WHO cone and tunnel tests. In total, 432 nets (144/brand) were evaluated using I-ACT and cone test. Olyset® nets (132/144) that did not meet the WHO cone test threshold criteria (≥ 80% mortality or ≥ 95% knockdown) were evaluated using tunnel tests with threshold criteria of ≥ 80% mortality or ≥ 90% feeding inhibition for WHO tunnel and I-ACT. Pass rate of nets tested by WHO combined standard WHO bioassays (cone/tunnel tests) was compared to pass in I-ACT only by net brand and time after distribution. RESULTS: Overall, more nets passed WHO threshold criteria when tested with I-ACT than with standard WHO bioassays 92% vs 69%, (OR: 4.1, 95% CI 3.5-4.7, p < 0.0001). The proportion of Olyset® nets that passed differed if WHO 2005 or WHO 2013 LN testing guidelines were followed: 77% vs 71%, respectively. Based on I-ACT results, PermaNet® 2.0 and NetProtect® demonstrated superior mortality and non-inferior feeding inhibition to Olyset® over 3 years of field use in Tanzania. CONCLUSION: Ifakara Ambient Chamber Test may have use for durability studies and non-inferiority testing of new ITN products. It measures composite bioefficacy and physical integrity with both mortality and feeding inhibition endpoints, using fewer mosquitoes than standard WHO bioassays (cone and tunnel tests). The I-ACT is a high-throughput assay to evaluate ITN products that work through either contact toxicity or feeding inhibition. I-ACT allows mosquitoes to interact with a host sleeping underneath a net as encountered in the field, without risk to human participants.


Assuntos
Bioensaio/métodos , Mosquiteiros Tratados com Inseticida/normas , Animais , Anopheles , Bioensaio/normas , Feminino , Humanos , Mosquiteiros Tratados com Inseticida/economia , Malária/prevenção & controle , Controle de Mosquitos/métodos , Piretrinas/farmacologia , Tanzânia , Organização Mundial da Saúde
9.
J Appl Toxicol ; 39(8): 1164-1172, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30957914

RESUMO

The amphibian metamorphosis assay represents an OECD Level 3 and EDSP Tier 1 ecotoxicity test assessing thyroid activity of chemicals in African clawed frog (Xenopus laevis). To evaluate the effectiveness of snout-vent length (SVL) normalization of hindlimb length (HLL), correlation between the HLL and SVL or body weight was evaluated in the control groups of 10 individual studies from three laboratories. Two studies required separate analysis of the Nieuwkoop-Faber (NF) stage ≤60 and >60 animals creating a total of 12 data sets. On study day 7, significant positive correlation between HLL and SVL or body weight was observed in eight and seven of the 10 data sets, respectively (r = 0.608-0.843 and 0.583-0.876). On study day 21, significant positive correlation between HLL and SVL or body weight was found in three and four of the 12 data sets, respectively (r = 0.452, 0.480 and 0.553 and r = 0.621, 0.546, 0.564 and 0.378). Significant positive correlation between HLL and SVL was found in three of five studies, including ≤NF stage 60 data (r = 0.564, 0.546 and 0.621). In one of eight studies, including >NF stage 60 data, the positive correlation between HLL and body weight was determined (r = 0.378). Negative or no correlation between HLL and SVL or body weight was found in the other late stage data sets. Therefore, use of SVL-normalized HLL to assess thyroid-mediated effects in X. laevis tadpoles is not warranted. HL stage relative to body stage should be considered.


Assuntos
Disruptores Endócrinos/toxicidade , Membro Posterior/efeitos dos fármacos , Larva/efeitos dos fármacos , Metamorfose Biológica/efeitos dos fármacos , Glândula Tireoide/efeitos dos fármacos , Poluentes Químicos da Água/toxicidade , Animais , Bioensaio/normas , Peso Corporal/efeitos dos fármacos , Membro Posterior/crescimento & desenvolvimento , Larva/crescimento & desenvolvimento , Tamanho do Órgão/efeitos dos fármacos , Glândula Tireoide/metabolismo , Xenopus laevis
10.
Cytotherapy ; 21(3): 367-375, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30890307

RESUMO

Translation of cell and gene therapies from pre-clinical experiments to clinical trials and final drug licensing brings requires the development, verification and even validation of the assays essential for the definition of the drug product. The technical and scientific challenges in doing this are far greater than they seem at first and are compounded by a lack of approved standards for assays used to support (c)GMP manufacture. This paper highlights some of those challenges and proposes solutions based on the experience of our colleagues using similar assay platforms in regulated pathology laboratories.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/métodos , Aprovação de Drogas/métodos , Terapia Genética/métodos , Imunoterapia Adotiva/métodos , Cooperação Internacional , Controle de Qualidade , Bioensaio/normas , Instabilidade Cromossômica/genética , Impressões Digitais de DNA/normas , Citometria de Fluxo/normas , Doença Enxerto-Hospedeiro/prevenção & controle , Doença Enxerto-Hospedeiro/terapia , Testes Hematológicos/normas , Teste de Histocompatibilidade/normas , Humanos , Laboratórios/normas , Terminologia como Assunto , Transplante Homólogo
11.
Toxicol In Vitro ; 57: 48-53, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30738888

RESUMO

The selection of reference and proficiency chemicals is an important basis for method validation and proficiency evaluations. Reference chemicals are a set of test substances used by a method developer to evaluate the reliability and relevance of a new method, in comparison to reference data (usually to a validated reference method). Proficiency chemicals, as defined in OECD Guidance Document on Good In Vitro Method Practices, are defined post validation as a subset of the reference chemicals or other chemicals with sufficient supporting data that are used by naïve laboratories to demonstrate technical competence with a validated test method. Proficiency chemicals should cover different physical states, several chemical classes within the applicability domain of the method and yield the full range of responses (in the validated reference method and in vivo), they shall be commercially available (at non-prohibitive costs) and have high quality reference data. If reference and subsequent proficiency chemicals are chosen without sufficient evidence for their inclusion, both test method evaluation and demonstration of technical proficiency can be hampered. In this report we present cases in which the selection of reference chemicals led to problems in the reproduction of the reference results and demonstration of technical proficiency: The variability of results was not always taken into account in selection of several reference substances of the LLNA (OECD TG 429). Based on the available reference data one proficiency chemical for the Corrositex skin corrosion test (OECD TG 435) should be replaced. Likewise, the expected in vitro result for one of the proficiency chemicals for the BCOP (OECD TG 437) was difficult to reproduce in several labs. Furthermore, it was not possible to obtain one of the proficiency chemicals for the Steroidogenesis Assay (OECD TG 456) at non-prohibitive costs at a reasonable purity. Based on these, we recommend changes of current proficiency chemicals lists with established OECD Test Guidelines and provide recommendations for developing future sets of reference chemicals.


Assuntos
Bioensaio/normas , Guias como Assunto/normas , Testes de Toxicidade/normas , Androgênios/normas , Androgênios/toxicidade , Animais , Bovinos , Cáusticos/normas , Cáusticos/toxicidade , Linhagem Celular , Córnea/efeitos dos fármacos , Estrogênios/normas , Estrogênios/toxicidade , Haptenos/toxicidade , Humanos , Técnicas In Vitro , Irritantes/normas , Irritantes/toxicidade , Linfonodos/efeitos dos fármacos , Camundongos , Organização para a Cooperação e Desenvolvimento Econômico , Padrões de Referência , Reprodutibilidade dos Testes , Testes de Toxicidade/métodos
12.
Health Phys ; 116(1): 105-108, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489373

RESUMO

The catastrophic loss of direct or indirect bioassay services can severely impact a site or facility's radiation protection program. While highly unlikely, circumstances such as fire, hurricane, other extreme weather conditions, unanticipated events, or contractual business decisions could result in the loss of either the onsite or offsite measurement capabilities for direct or indirect radiobioassay services. The process and elements that need to be addressed in obtaining alternate or replacement bioassay services can be described in relatively simple terms, but can be very complex and time consuming to implement. The contingency plan developed for one large, complex radiobioassay program is a good example for addressing these items.


Assuntos
Bioensaio/normas , Emergências , Laboratórios/normas , Exposição à Radiação/análise , Monitoramento de Radiação/normas , Avaliação da Tecnologia Biomédica/normas , Planejamento em Saúde , Humanos , Proteção Radiológica
13.
SLAS Discov ; 23(9): 919-929, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30011241

RESUMO

Bruton's tyrosine kinase (BTK) is a clinically validated target for B-cell leukemias and lymphomas with FDA-approved small-molecule inhibitors ibrutinib and acalabrutinib. Tirabrutinib (GS-4059/ONO-4059, Gilead Sciences, Inc., Foster City, CA) is a second-generation, potent, selective, irreversible BTK inhibitor in clinical development for lymphoid malignancies, including chronic lymphocytic leukemia (CLL) and diffuse large B-cell lymphoma (DLBCL). An accurate pharmacodynamic assay to assess tirabrutinib target coverage in phase 1/2 clinical studies will inform dose and schedule selection for advanced clinical evaluation. We developed a novel duplex homogeneous BTK occupancy assay based on time-resolved fluorescence resonance energy transfer (TR-FRET) to measure free and total BTK levels in a multiplexed format. The dual-wavelength emission property of terbium-conjugated anti-BTK antibody served as the energy donor for two fluorescent energy acceptors with distinct excitation and emission spectra. The assay was characterized and qualified using full-length purified recombinant human BTK protein and peripheral blood mononuclear cells derived from healthy volunteers and patients with CLL. We demonstrated assay utility using cells derived from lymph node and bone marrow samples from patients with CLL and DLBCL. Our TR-FRET-based BTK occupancy assay provides accurate, quantitative assessment of BTK occupancy in the clinical trial program for tirabrutinib and is in use in ongoing clinical studies.


Assuntos
Tirosina Quinase da Agamaglobulinemia/antagonistas & inibidores , Bioensaio , Imidazóis/farmacologia , Pirimidinas/farmacologia , Bioensaio/métodos , Bioensaio/normas , Células da Medula Óssea/efeitos dos fármacos , Células da Medula Óssea/metabolismo , Linhagem Celular Tumoral , Estabilidade de Medicamentos , Ativação Enzimática/efeitos dos fármacos , Humanos , Imidazóis/química , Leucemia Linfocítica Crônica de Células B , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/metabolismo , Estrutura Molecular , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/farmacologia , Pirimidinas/química , Reprodutibilidade dos Testes
14.
Chem Biol Interact ; 292: 1-8, 2018 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-29953848

RESUMO

Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC20) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1ß, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1ß production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1ß were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1ß measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye toxicity, differentiating damage from irritation potential.


Assuntos
Alternativas aos Testes com Animais/métodos , Alternativas aos Testes com Animais/normas , Irritantes/toxicidade , Queratinócitos/efeitos dos fármacos , Testes de Toxicidade Aguda/métodos , Testes de Toxicidade Aguda/normas , Bioensaio/normas , Linhagem Celular , Citocinas/análise , Ensaio de Imunoadsorção Enzimática , Humanos , Inflamação/induzido quimicamente , Concentração Inibidora 50 , Queratinócitos/química , Modelos Biológicos
15.
Environ Pollut ; 236: 91-99, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29414378

RESUMO

Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods.


Assuntos
Bioensaio/métodos , Caenorhabditis elegans/efeitos dos fármacos , Poluentes do Solo/toxicidade , Solo/química , Animais , Bioensaio/normas , Caenorhabditis elegans/crescimento & desenvolvimento , Feminino , Masculino , Padrões de Referência , Testes de Toxicidade/métodos
16.
AAPS J ; 20(1): 25, 2017 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-29285735

RESUMO

The American Association of Pharmaceutical Scientists (AAPS) biosimilar focus group on nonclinical and clinical assays has developed this manuscript to guide the industry on best practices and testing strategies when developing neutralizing antibody (NAb) assays for biosimilar programs. The immunogenicity assessment to biosimilar and originator drug products is one of the key aspects of clinical programs for biosimilars to demonstrate biosimilarity. Establishing that there are no clinically meaningful differences in immune response between a proposed product and the originator product is a key element in the demonstration of biosimilarity. It is critical to collect, evaluate, and compare the safety and immunogenicity data from the clinical pharmacology, safety, and/or efficacy studies especially when the originator drug product is known to have potential for immune-mediated toxicity. This manuscript aims to provide a comprehensive review and recommendations on assay formats, critical reagents, approaches to method development, and validation of the neutralizing antibody assays in extrapolation within the scope of biosimilar drug development programs. Even if there are multiple options on the development and validation of NAb assays for biosimilar programs, the type of drug and its MoA will help determine the assay format and technical platform for NAb assessment (e.g., cell-based or non-cell-based assay). We recommend to always perform a one-assay approach as it is better to confirm the biosimilarity using one-assay for NAb. If a one-assay approach is not feasible, then a two-assay format may be used. This manuscript will provide all the details necessary to develop NAb assays for biosimilars.


Assuntos
Imunidade Adaptativa/efeitos dos fármacos , Anticorpos Neutralizantes/análise , Bioensaio/métodos , Medicamentos Biossimilares/farmacologia , Estudos de Validação como Assunto , Animais , Bioensaio/normas , Linhagem Celular , Avaliação Pré-Clínica de Medicamentos/métodos , Avaliação Pré-Clínica de Medicamentos/normas , Humanos , Modelos Animais
18.
Health Phys ; 113(2): 102-109, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28658055

RESUMO

Effective dose was introduced by the ICRP for the single, over-arching purpose of setting limits for radiation protection. Effective dose is a derived quantity or mathematical construct and not a physical, measurable quantity. The formula for calculating effective dose to a reference model incorporates terms to account for all radiation types, organ and tissue radiosensitivities, population groups, and multiple biological endpoints. The properties and appropriate applications of effective dose are not well understood by many within and outside the health physics profession; no other quantity in radiation protection has been more confusing or misunderstood. According to ICRP Publication 103, effective dose is to be used for "prospective dose assessment for planning and optimization in radiological protection, and retrospective demonstration of compliance for regulatory purposes." In practice, effective dose has been applied incorrectly to predict cancer risk among exposed persons. The concept of effective dose applies generally to reference models only and not to individual subjects. While conceived to represent a measure of cancer risk or heritable detrimental effects, effective dose is not predictive of future cancer risk. The formula for calculating effective dose incorporates committee-selected weighting factors for radiation quality and organ sensitivity; however, the organ weighting factors are averaged across all ages and both genders and thus do not apply to any specific individual or radiosensitive subpopulations such as children and young women. Further, it is not appropriate to apply effective dose to individual medical patients because patient-specific parameters may vary substantially from the assumptions used in generalized models. Also, effective dose is not applicable to therapeutic uses of radiation, as its mathematical underpinnings pertain only to observed late (stochastic) effects of radiation exposure and do not account for short-term adverse tissue reactions. The weighting factors incorporate substantial uncertainties, and linearity of the dose-response function at low dose is uncertain and highly disputed. Since effective dose is not predictive of future cancer incidence, it follows that effective dose should never be used to estimate future cancer risk from specific sources of radiation exposure. Instead, individual assessments of potential detriment should only be based on organ or tissue radiation absorbed dose, together with best scientific understanding of the corresponding dose-response relationships.


Assuntos
Neoplasias Induzidas por Radiação/epidemiologia , Modelos de Riscos Proporcionais , Exposição à Radiação/estatística & dados numéricos , Proteção Radiológica/normas , Eficiência Biológica Relativa , Medição de Risco/normas , Contagem Corporal Total/normas , Bioensaio/normas , Humanos , Incidência , Internacionalidade , Guias de Prática Clínica como Assunto , Prevalência , Radiação , Doses de Radiação , Monitoramento de Radiação/normas , Taxa de Sobrevida
19.
Health Phys ; 112(3): 282-293, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28121729

RESUMO

Following a radiation emergency, children may be internally contaminated by the radionuclide(s) involved. Timely assessment of the contamination informs the need for medical treatment for those persons who had significant intakes and reassures those whose intakes are not a medical concern. In vitro bioassay reference values for children of all ICRP age groups are derived for 30 contamination scenario/radionuclide combinations involving 13 radionuclides. These bioassay values are derived from an intake that leads to a 70-y committed effective dose of 50 mSv or a 30-d RBE-weighted absorbed dose to the lungs of 0.2 Gy-Eq, depending on which criterion is more strict. These values are presented in a collection of lookup tables that can be used directly as references.


Assuntos
Bioensaio/normas , Serviços Médicos de Emergência/normas , Exposição à Radiação/análise , Monitoramento de Radiação/normas , Radioisótopos/análise , Triagem/normas , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Masculino , Pediatria/normas , Proteção Radiológica/normas , Liberação Nociva de Radioativos , Radioisótopos/normas , Valores de Referência
20.
Int J Radiat Biol ; 93(1): 48-57, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27813725

RESUMO

PURPOSE: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G0-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay. MATERIALS AND METHODS: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals. RESULTS: Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24 h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics. CONCLUSIONS: Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G0-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/citologia , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Fase de Repouso do Ciclo Celular/genética , Fase de Repouso do Ciclo Celular/efeitos da radiação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA