Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
Ann Rheum Dis ; 75(6): 1161-5, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26835701

RESUMO

OBJECTIVES: Extension of disease beyond the atrioventricular (AV) node is associated with increased mortality in cardiac neonatal lupus (NL). Treatment of isolated heart block with fluorinated steroids to prevent disease progression has been considered but published data are limited and discordant regarding efficacy. This study evaluated whether fluorinated steroids given to manage isolated advanced block prevented development of disease beyond the AV node and conferred a survival benefit. METHODS: In this retrospective study of cases enrolled in the Research Registry for NL, inclusion was restricted to anti-SSA/Ro-exposed cases presenting with isolated advanced heart block in utero who either received fluorinated steroids within 1 week of detection (N=71) or no treatment (N=85). Outcomes evaluated were: development of endocardial fibroelastosis, dilated cardiomyopathy and/or hydrops fetalis; mortality and pacemaker implantation. RESULTS: In Cox proportional hazards regression analyses, fluorinated steroids did not significantly prevent development of disease beyond the AV node (adjusted HR=0.90; 95% CI 0.43 to 1.85; p=0.77), reduce mortality (HR=1.63; 95% CI 0.43 to 6.14; p=0.47) or forestall/prevent pacemaker implantation (HR=0.87; 95% CI 0.57 to 1.33; p=0.53). No risk factors for development of disease beyond the AV node were identified. CONCLUSIONS: These data do not provide evidence to support the use of fluorinated steroids to prevent disease progression or death in cases presenting with isolated heart block.


Assuntos
Anticorpos Antinucleares/sangue , Doenças Fetais/tratamento farmacológico , Bloqueio Cardíaco/tratamento farmacológico , Esteroides Fluorados/uso terapêutico , Adulto , Progressão da Doença , Feminino , Doenças Fetais/diagnóstico por imagem , Doenças Fetais/mortalidade , Bloqueio Cardíaco/congênito , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/mortalidade , Humanos , Recém-Nascido , Estimativa de Kaplan-Meier , Lúpus Eritematoso Sistêmico/complicações , Lúpus Eritematoso Sistêmico/congênito , Masculino , Marca-Passo Artificial , Cuidado Pré-Natal/métodos , Sistema de Registros , Estudos Retrospectivos , Ultrassonografia Pré-Natal , Estados Unidos/epidemiologia
3.
Jpn Heart J ; 45(3): 513-20, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15240971

RESUMO

We investigated the use of a catheter-based cryoablation system on atrioventricular (AV) junction ablation in dogs. In five dogs, the cryoablation catheter was introduced to the AV junction area in order to create transient high degree or complete AV block. Cryo-freezing energy was applied by lowering the temperature to -75 degrees C for five minutes as a single cycle. This cycle was repeated until significant impairment of the AV conduction appeared. Transient high degree and complete AV block was obtained in all five dogs without any adverse effects. The iceball formation was identified by intracardiac echocardiography. Ablation of the AV junction is effective with several freeze-thaw cycles using a transvenous catheter cryoablation system.


Assuntos
Nó Atrioventricular/cirurgia , Criocirurgia/métodos , Ecocardiografia , Bloqueio Cardíaco/etiologia , Animais , Cateterismo , Cães , Eletrocardiografia , Eletrodos , Congelamento , Bloqueio Cardíaco/diagnóstico por imagem
4.
Arq Bras Cardiol ; 81(5): 483-93, 2003 Nov.
Artigo em Inglês, Português | MEDLINE | ID: mdl-14666269

RESUMO

OBJECTIVE: Noninvasive cardiac assessment of newborns and infants of women with systemic lupus erythematosus. The children had no congenital total atrioventricular block and were compared with the children of healthy women. METHODS: We prospectively assessed 13 newborns and infants aged 1 to 60 days, children of women with systemic lupus erythematosus and without congenital total atrioventricular block. These children were compared with 30 children of women who had no lupus or anti-Ro/SSA antibodies, and no risk factors for congenital heart disease either. Their age groups matched. The following examinations were performed: cardiological physical examination, electrocardiography, echocardiography, and signal-averaged electrocardiography. RESULTS: The statistical analysis showed no significant difference in ventricular function or in the cardiac conduction system between the groups. CONCLUSION: In regard to the conduction system and ventricular function in the absence of total atrioventricular block, no statistically significant difference was observed between the children of women with systemic lupus erythematosus and children of healthy women.


Assuntos
Filho de Pais com Deficiência , Bloqueio Cardíaco/diagnóstico , Lúpus Eritematoso Sistêmico , Anticorpos Antinucleares/sangue , Ecocardiografia Doppler em Cores , Eletrocardiografia , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/imunologia , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Estatísticas não Paramétricas
5.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2240-5, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9825326

RESUMO

Atrial electrode position was determined by radiographic analysis in 160 patients paced in single-lead VDD for second- or third-degree A-V block, implanted > 1 year with Phymos single pass leads and Phymos 3D pacemakers. The packing lead features an atrial dipole with a 30-mm electrode interspace. In 44% of patients, the upper atrial electrode was positioned within a band of 20 mm centered at the level of the superior vena caval insertion (junctional area) and was in the inferior vena cava or in the atrium in 35% and 21% of cases, respectively. In spite of these different dipole locations, all patients had stable atrium-driven pacing at routine follow-up visits. With the electrode in the junctional area, unipolar stimulation of up to 5 V for 1 ms resulted in stable atrial capture in 63% and 59% of the patients in supine and upright positions, respectively. With the electrode in the atrium, corresponding success rates were 45% and 54%. In the atrium, however, the prevalence of diaphragmatic stimulation was significantly lower than at the junction (10% vs 42% in supine position; 21% vs 47% upright). Though atrial sensing function proved adequate in a wide range of positions, these results suggest that the Phymos lead atrial dipole should be positioned within the atrium, as close as possible to the atrial wall, to maximize the number of VDD patients who might benefit from single-lead DDD pacing.


Assuntos
Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Coração/diagnóstico por imagem , Marca-Passo Artificial , Eletrodos Implantados , Desenho de Equipamento , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Humanos , Masculino , Postura , Radiografia
6.
Pacing Clin Electrophysiol ; 19(11 Pt 1): 1560-7, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8946451

RESUMO

Dual sensor ventricular demand rate responsive (VVIR mode) pacing was compared with single sensor rate responsive pacing to assess whether this new development should be more widely incorporated in modern pacemaker devices. A within patient randomized, double-blind crossover study involving ten patients, mean age 67.4 years (70% male), had Medtronic Legend Plus dual sensor VVIR pacemakers implanted for high grade AV block and chronic or persistent paroxysmal atrial fibrillation. Performance values were compared to 20 healthy control subjects of a similar age and gender. Patients were both subjectively and objectively assessed after 2 weeks of out-of-hospital activity in VVIR mode (minute ventilation sensing), VVIR mode (activity sensing), VVIR mode (dual sensor), and VVI mode (no rate response). All patients were assessed for subjective preference for, and objective improvement in, any pacing modality as assessed by standardized daily activity protocols and graded exercise treadmill testing. Subjective perception of exercise capacity and functional status was significantly lower in VVI mode (P < 0.05) compared to any of the VVIR modes, which did not differ. After completion of the study 70% of patients chose VVIR as their preferred mode, with 30% expressing no preference. Forty percent preferred activity sensor VVIR mode pacing, 30% preferred dual sensor VVIR mode pacing, and 70% found either dual sensor VVIR mode, minute ventilation sensor VVIR mode, or both modalities least acceptable. No patient found activity sensing VVIR mode least acceptable. Graded treadmill testing revealed significantly lower exercise tolerance during VVI mode pacing (P < 0.01) compared to the VVIR modalities, which did not differ. Overall, chronotropic response was best with dual sensor pacing during standardized daily activity protocols and during the standard car journey. The data from this study suggest that there is no marked clinical advantage obtained from the use of dual sensor devices over current activity sensing ventricular demand rate responsive pacemakers, but with the probable added disadvantages of increased size, complexity, cost, and decreased longevity.


Assuntos
Estimulação Cardíaca Artificial/métodos , Atividades Cotidianas , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/economia , Custos e Análise de Custo , Estudos Cross-Over , Método Duplo-Cego , Ecocardiografia , Teste de Esforço , Tolerância ao Exercício , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/fisiopatologia , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Psicológico
7.
Pacing Clin Electrophysiol ; 16(11): 2157-67, 1993 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7505929

RESUMO

To determine if rate adaptation of the atrioventricular (AV) delay (i.e., linearly decreasing the AV interval for increasing sinus rate) improves exercise left ventricular systolic hemodynamics, we performed paired maximal semi-upright bicycle exercise tests (EXTs) on 14 chronotropically competent patients with dual chamber pacemakers. Nine patients with complete AV block (CAVB) and total ventricular pacing dependence during exercise comprised the experimental group. Pacemakers in these patients were programmed randomly to rate adaptive AV delay (AVDR) for one EXT and fixed AV delay (AVDF) for the other EXT. AVDF was 156 msec; AVDR decreased linearly from 156-63 msec from rates of 78-142 beats/min. The other five patients had intact AV conduction and comprised the control group who were exercised in identical fashion while their pacemakers were inhibited throughout exercise to assure reproducibility of hemodynamic measurements between EXTs. Cardiac hemodynamics were calculated using measured Doppler echocardiographic systolic aortic valve flows recorded suprasternally with an independent 2-MHz Doppler transducer during a graded ramp exercise protocol. For analysis, exercise was divided into four phases to compare Doppler measurements at submaximal and maximal levels of exercise: rest, early exercise (1st stage), late exercise (stage preceding peak), and peak. Patients achieved statistically similar heart rates between EXTs at each phase of exercise. Although at lower levels of exercise cardiac hemodynamics did not differ, experimental patients (with CAVB) showed a statistically significant benefit to cardiac output at peak exercise with heart rates of 129 +/- 13 beats/min (AVDR: 9.4 +/- 2.8 L/min; AVDF: 8.2 +/- 2.6 L/min, P = 0.002), stroke volume (AVDR: 74.1 +/- 25.6 mL; AVDF: 64.3 +/- 24.4 mL, P = 0.0003), and aortic ejection time (AVDR: 253.3 +/- 35.7 msec; AVDF: 226.7 +/- 35.0 msec, P = 0.002). Duration of exercise, peak rate pressure product, peak aortic flow velocities, and acceleration times did not differ. In contrast, control group patients (intact AV conduction throughout exercise) showed no statistical differences between any hemodynamic parameters measured at any phase of exercise from the first to second exercise test. These data demonstrate that systolic cardiac hemodynamics measured echocardiographically at the high heart rates achieved with peak exercise are improved with AVDR compared to AVDF in chronotropically competent patients with complete AV block. This is due primarily to improved stroke volume and a longer systolic ejection time with AV delay rate adaptation.


Assuntos
Nó Atrioventricular/fisiopatologia , Ecocardiografia Doppler , Teste de Esforço , Bloqueio Cardíaco/fisiopatologia , Hemodinâmica , Marca-Passo Artificial , Adulto , Idoso , Débito Cardíaco , Eletrocardiografia , Feminino , Bloqueio Cardíaco/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico
8.
J Electrocardiol ; 16(3): 297-301, 1983 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6619704

RESUMO

The ECGs of 1,095 patients with coronary angiographic evidence of significant coronary artery disease (greater than or equal to 50% obstructive lesion in at least one major coronary artery) were reviewed. Five patients had left posterior hemiblock (LPHB), an incidence of 0.5%. Three of five patients also had a right bundle branch block (RBBB). Of the five patients with LPHB, all had significant right coronary artery (RCA) disease (four complete occlusions, one 90% obstructive lesion). All five patients having LPHB also had evidence of critical disease (greater than or equal to 75% obstruction) of at least one of the major branches of the left coronary artery; four of the five had complete occlusion of the left anterior descending coronary artery (LAD). The left circumflex coronary artery (CFx) was critically diseased in three patients. The ECGs of four patients showed evidence of only one myocardial infarction while one patient had evidence of an anterior and an inferior infarction. It is concluded that the presence of LPHB in patients with coronary artery disease is an ominous electrocardiographic finding, and is associated with extensive coronary artery disease.


Assuntos
Angiografia Coronária , Bloqueio Cardíaco/diagnóstico por imagem , Adulto , Eletrocardiografia , Feminino , Bloqueio Cardíaco/complicações , Bloqueio Cardíaco/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA