Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr Ophthalmol Strabismus ; 61(3): e28-e32, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38788143

RESUMO

Congenital corneal staphyloma is a rare congenital malformation with guarded visual potential. The cornea is opaque, markedly ectatic, and lined by uveal tissue with a variety of associated anterior segment abnormalities. In this case report, the detailed histopathology of this condition is highlighted with an unusual finding of the malformed lens. [J Pediatr Ophthalmol Strabismus. 2024;61(3):e28-e32.].


Assuntos
Segmento Anterior do Olho , Córnea , Doenças da Córnea , Humanos , Segmento Anterior do Olho/anormalidades , Segmento Anterior do Olho/diagnóstico por imagem , Doenças da Córnea/diagnóstico , Doenças da Córnea/congênito , Córnea/patologia , Córnea/anormalidades , Masculino , Anormalidades do Olho/diagnóstico , Feminino , Lactente
2.
An Bras Dermatol ; 99(4): 513-519, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38614939

RESUMO

OBJECTIVE: To evaluate the effects of rosacea on ocular surface changes such as alterations in dry eye parameters, corneal densitometry, and aberrations, in comparison with healthy controls. METHODS: A total of 88 eyes of 44 patients diagnosed with rosacea and 88 eyes of 44 healthy controls were enrolled in this cross-sectional study. All participants underwent a comprehensive dermatologic and ophthalmic examination and Tear Break-Up Time (TBUT) and Schirmer-1 tests were performed. The rosacea subtype and Demodex count and OSDI scores of all participants were recorded. Corneal topographic, densitometric, and aberrometric measurements were obtained using the Scheimpflug imaging system. RESULTS: The mean age of the 44 patients was 41.2 ±â€¯11.0 years of whom 31 (70.5%) were female. The mean TBUT and Schirmer-1 test values were significantly decreased and OSDI scores were significantly increased in the rosacea group compared to healthy controls (p < 0.01 for all). The most common subtype of rosacea was erythematotelangiectatic rosacea (70.4%). The severity grading of rosacea revealed that 18 (40.9%) patients had moderate erythema. The median (min-max) Demodex count was 14.0 (0-120) and the disease duration was 24.0 (5-360) months. The comparison of the corneal densitometry values revealed that the densitometry measurements in all concentric zones, especially in central and posterior zones were higher in rosacea patients. Corneal aberrometric values in the posterior surface were also lower in the rosacea group compared to healthy controls. The topographic anterior chamber values were significantly lower in the rosacea group. STUDY LIMITATIONS: Relatively small sample size, variable time interval to hospital admission, and lack of follow-up data are among the limitations of the study. Future studies with larger sample sizes may also enlighten the mechanisms of controversial anterior segment findings by evaluating rosacea patients who have uveitis and those who do not. CONCLUSION: Given the fact that ocular signs may precede cutaneous disease, rosacea is frequently underrecognized by ophthalmologists. Therefore, a comprehensive examination of the ocular surface and assessment of the anterior segment is essential. The main priority of the ophthalmologist is to treat meibomian gland dysfunction and Demodex infection to prevent undesired ocular outcomes.


Assuntos
Córnea , Topografia da Córnea , Rosácea , Humanos , Rosácea/diagnóstico por imagem , Feminino , Estudos Transversais , Adulto , Masculino , Pessoa de Meia-Idade , Córnea/diagnóstico por imagem , Córnea/patologia , Estudos de Casos e Controles , Topografia da Córnea/métodos , Densitometria/métodos , Índice de Gravidade de Doença , Segmento Anterior do Olho/diagnóstico por imagem , Síndromes do Olho Seco/diagnóstico por imagem , Valores de Referência , Estatísticas não Paramétricas
3.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649848

RESUMO

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Assuntos
Segmento Anterior do Olho , Córnea , Topografia da Córnea , Miopia , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Adulto , Miopia/diagnóstico , Miopia/fisiopatologia , Topografia da Córnea/métodos , Topografia da Córnea/instrumentação , Reprodutibilidade dos Testes , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia , Adulto Jovem , Córnea/diagnóstico por imagem , Córnea/patologia , Pessoa de Meia-Idade , Biometria/métodos , Adolescente , Estudos Prospectivos
4.
Eye (Lond) ; 38(7): 1333-1341, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38200321

RESUMO

BACKGROUND/OBJECTIVES: Axial length, a key measurement in myopia management, is not accessible in many settings. We aimed to develop and assess machine learning models to estimate the axial length of young myopic eyes. SUBJECTS/METHODS: Linear regression, symbolic regression, gradient boosting and multilayer perceptron models were developed using age, sex, cycloplegic spherical equivalent refraction (SER) and corneal curvature. Training data were from 8135 (28% myopic) children and adolescents from Ireland, Northern Ireland and China. Model performance was tested on an additional 300 myopic individuals using traditional metrics alongside the estimated axial length vs age relationship. Linear regression and receiver operator characteristics (ROC) curves were used for statistical analysis. The contribution of the effective crystalline lens power to error in axial length estimation was calculated to define the latter's physiological limits. RESULTS: Axial length estimation models were applicable across all testing regions (p ≥ 0.96 for training by testing region interaction). The linear regression model performed best based on agreement metrics (mean absolute error [MAE] = 0.31 mm, coefficient of repeatability = 0.79 mm) and a smooth, monotonic estimated axial length vs age relationship. This model was better at identifying high-risk eyes (axial length >98th centile) than SER alone (area under the curve 0.89 vs 0.79, respectively). Without knowing lens power, the calculated limits of axial length estimation were 0.30 mm for MAE and 0.75 mm for coefficient of repeatability. CONCLUSIONS: In myopic eyes, we demonstrated superior axial length estimation with a linear regression model utilising age, sex and refractive metrics and showed its clinical utility as a risk stratification tool.


Assuntos
Comprimento Axial do Olho , Miopia , Refração Ocular , Humanos , Miopia/fisiopatologia , Miopia/diagnóstico , Masculino , Feminino , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Adolescente , Criança , Refração Ocular/fisiologia , Curva ROC , Biometria/métodos , Adulto Jovem , Cristalino/fisiopatologia , Cristalino/diagnóstico por imagem , Cristalino/patologia , Modelos Lineares , Córnea/patologia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia
5.
Exp Eye Res ; 226: 109354, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36539053

RESUMO

The eye is ten times more vulnerable to chemical warfare agents than other organs. Consistently, exposure to vesicant arsenical lewisite (LEW) manifests significant corneal damage leading to chronic inflammation, corneal opacity, vascularization, and edema, culminating in corneal cell death. However, despite the progress has made in the research field investigating arsenical-induced pathogenesis of the anterior chamber of the eye, the retinal damage resulted from exposure to arsenicals has not been identified yet. Therefore, we investigated the effects of direct ocular exposure (DOE) to LEW and phenylarsine oxide (PAO) on the retina. DOE to arsenicals was conducted using the vapor cap method at the MRIGlobal facility or an eye patch soaked in solutions with different PAO concentrations at UAB. Animals were assessed at 1, 3, 14, and 28 days postexposure. Results of the study demonstrated that both arsenicals cause severe retinal damage, activating proinflammatory programs and launching apoptotic cell death. Moreover, the DOE to PAO resulted in diminishing ERG amplitudes in a dose-dependent manner, indicating severe retinal damage. The current study established a prototype mouse model of arsenical-induced ocular damage that can be widely used to identify the key cellular signaling pathways involved in retinal damage pathobiology and to validate medical countermeasures against the progression of ocular damage.


Assuntos
Arsenicais , Traumatismos Oculares , Doenças Retinianas , Animais , Camundongos , Irritantes , Arsenicais/efeitos adversos , Córnea/patologia , Traumatismos Oculares/patologia , Doenças Retinianas/patologia
6.
Food Chem Toxicol ; 170: 113457, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36244458

RESUMO

This study developed an air-liquid interface (ALI) corneal model using explants bovine eyes for ocular toxicity assessment of ten chemicals and seven hair straightening mixtures. It was successfully maintained physiologically viable and normal for six days. Both eye damage (GHS cat. 1) and irritating (GHS cat. 2) chemicals induced corneal injury in our model. However, cat. 2 irritants triggered moderate damage when compared to cat. 1 agents, which induced a marked cytotoxicity profile. The mixtures were also able to trigger viability reduction associated with histopathological changes in the corneal tissues, especially when the exposure was via aerosol particles. Thus, the chemical exposure microenvironment simulation seemed to provide more reliable toxicological data. Moreover, mixture-induced corneal damage correlated with increased ROS levels, suggesting a close correlation between tissue death and oxidative stress. Besides mixtures showing the potential to induce moderate/mild ocular toxicity, we could verify that the corneal tissue damage showed reversibility due to the recovery from the injury after exposure to some of the mixtures. Hence, our ex vivo corneal model seems to be a simple and cost-effective approach for future studies related to further investigating the reversibility of damage in the cornea triggered by chemicals and their mixtures.


Assuntos
Alternativas aos Testes com Animais , Neuropatia Óptica Tóxica , Bovinos , Animais , Testes de Toxicidade , Irritantes/toxicidade , Córnea/patologia , Cabelo
7.
J Small Anim Pract ; 63(3): 188-196, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34937128

RESUMO

OBJECTIVES: To assess the inter-rater agreement of corneal cytology findings in canine ulcerative keratitis by veterinary surgeons of different training levels and the agreement of corneal cytology with culture. MATERIALS AND METHODS: Dogs with progressive ulcerative keratitis were prospectively recruited for corneal cytology and culture. Corneal cytology slides were reviewed by veterinary surgeons of different training levels (three general practitioners, three ophthalmologists and three pathologists). The inter-rater agreement of cytology findings and agreement of cytology with culture was assessed using the kappa measure of agreement. RESULTS: The study included 145 corneal cytology samples from 143 dogs (145 eyes) with progressive ulcerative keratitis. Positive cultures were obtained from 81 of 145 (56%) eyes. The most commonly isolated pathogens were Streptococcus canis, Pseudomonas aeruginosa and Staphylococcus pseudintermedius. The results demonstrated increased inter-rater agreement of corneal cytology and increased agreement with culture with increased ocular pathology expertise (pathologists > ophthalmologists > general practitioners). CLINICAL SIGNIFICANCE: This study provides important information about the diagnostic value of corneal cytology in canine ulcerative keratitis and the most common pathogens involved in such cases in the UK. Based on the results of this study, cytology findings should be interpreted in conjunction with the expertise of the observer. For maximal pathogen identification, both cytology and culture should be considered.


Assuntos
Úlcera da Córnea , Doenças do Cão , Animais , Córnea/patologia , Úlcera da Córnea/diagnóstico , Úlcera da Córnea/patologia , Úlcera da Córnea/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/patologia , Cães
8.
Sci Rep ; 11(1): 16037, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-34362986

RESUMO

The progression of keratoconus is commonly determined by comparing the results of corneal tomographic measurements on different occasions. However, investigations on the repeatability of measurements are commonly performed within the same day, thus not taking the inter-day variation into account. The effect of keratoconus disease severity on the measurement error is also seldom considered. In this post hoc investigation, the parameters A, B and C in the Belin ABCD Progression Display were evaluated in relation to disease severity in intra-day and inter-day measurements. Four consecutive measurements were performed on 61 patients with keratoconus on the same day (intra-day). In another cohort, four consecutive measurements were obtained and then repeated 3 days later in 25 patients with keratoconus and 25 healthy controls (inter-day). The results suggest that the diagnosis of disease progression would benefit from inter-day measurements, and the stratification of the parameters A and C according to disease severity. It is also recommended that tomographic systems such as the Pentacam HR be modified to allow the comparison of both single measurements and the mean of replicate measurements of the parameters used in the assessment of progression of keratoconus.


Assuntos
Córnea/patologia , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Ceratocone/patologia , Índice de Gravidade de Doença , Adolescente , Adulto , Estudos de Casos e Controles , Córnea/diagnóstico por imagem , Feminino , Humanos , Ceratocone/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
9.
Acta Ophthalmol ; 99(8): e1315-e1325, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33683020

RESUMO

PURPOSE: To assess and compare corneal sub-basal nerve plexus morphology with circulating lymphocyte subsets, immunologic status and disease activity in Sjögren syndrome (SjS) patients. METHODS: Fifty-five SjS patients, 63 Sicca patients (not fulfilling SjS criteria), 18 rheumatoid arthritis (RA) patients and 20 healthy controls (HC) were included. Systemic disease activity in SjS was assessed with the ESSDAI score. Lymphocyte subpopulations were studied with flow cytometry. Corneal confocal microscopy and ImageJ software were used to characterize corneal sub-basal nerve plexus in terms of nerve density (CNFD), length (CNFL) and tortuosity (CNFT). Conventional dry eye tests were also performed. RESULTS: CNFL and CNFD were lower in SjS, Sicca and RA groups, compared to HC (p < 0.001 for both SjS and Sicca); CNFL p = 0.005, CNFD p = 0.018 in RA). CNFT was higher in SjS, followed by Sicca, RA and HC. A negative correlation was found between ESSDAI score and CNFL (r=-0.735, p = 0.012). CNFL correlated negatively with IL21+ CD8+ T cells (r=-0.279, p = 0.039) and a positively with total memory (r = 0.299, p = 0.027), unswitched memory (r = 0.281, p = 0.038) and CD24Hi CD27+ (r = 0.278, p = 0.040) B cells. CNFD showed a tendency to significance in its negative correlation with ESSDAI (r=-0.592, p = 0.071) and in its positive correlation with switched memory B cells (r = 0.644, p = 0.068). CONCLUSIONS: This is the first study aiming to correlate ocular findings with lymphocyte subsets in SjS. The associations founded between CNFL and CNFD and disease activity, IL21+ follicular T cells and some B-cell subsets suggest that corneal nerve damage may parallel systemic disease activity and inflammatory cells' dynamics.


Assuntos
Córnea/inervação , Imunidade Celular , Subpopulações de Linfócitos/patologia , Fibras Nervosas/patologia , Síndrome de Sjogren/diagnóstico , Lágrimas/citologia , Contagem de Células , Córnea/imunologia , Córnea/patologia , Feminino , Citometria de Fluxo , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Fibras Nervosas/imunologia , Síndrome de Sjogren/imunologia
10.
Sci Rep ; 11(1): 3041, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33542296

RESUMO

To evaluate the repeatability of Corvis ST corneal biomechanical, tonometry and pachymetry measurements, and agreement of pachymetry measures with the Pentacam HR and RTVue OCT. Three consecutive measurements of the right eye of 238 myopic subjects were acquired with the Corvis ST, Pentacam HR, and RTVue OCT. Repeatability of Corvis ST was evaluated by within-subject standard deviation [Sw] and repeatability limit [r]. The agreement of central corneal thickness (CCT) measurements were compared among the three instruments using the Bland-Altman limits of agreement. Comparisons were further stratified by CCT (Corneathin ≤ 500 µm; Corneanormal = 500-550 µm; Corneathick > 550 µm). Sw was below 1 mmHg in Corneathin, Corneanormal, and Corneathick groups for IOP and bIOP. Sw for SP-A1 were 4.880, 6.128, 7.719 mmHg/mm respectively. Sw for CBI were 0.228, 0.157, 0.076, and correspondingly Sw for TBI and SSI were 0.094 and 0.056, 0.079 and 0.053, 0.070 and 0.053. The Bland-Altman plots for CCT implied poor agreement with mean differences of 29.49 µm between Corvis and OCT, 9.33 µm between Pentacam and OCT, and 20.16 µm between Corvis and Pentacam. The Corvis ST showed good repeatability with the exception of CBI in the various CCT groups. The CCT measured by Corvis ST was not interchangeable with Pentacam HR and RTVue OCT.


Assuntos
Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Miopia/diagnóstico por imagem , Adolescente , Adulto , Córnea/patologia , Paquimetria Corneana/métodos , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/patologia , Tonometria Ocular/métodos , Adulto Jovem
11.
Am J Ophthalmol ; 225: 38-46, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33422466

RESUMO

PURPOSE: To evaluate the interday repeatability in the measurement of parameters used for the detection of progression of keratoconus by prediction limits (PL) for single measurements, and the repeatability coefficient (RC) for the mean of replicate measurements. DESIGN: Prospective reliability analysis for cases and control eyes. METHODS: Twenty-five eyes in 25 subjects with KC and 25 eyes in 25 healthy controls were included. Four consecutive measurements were made, 3 days apart, with a Pentacam HR tomographic instrument (denoted the Pentacam) and a Nidek ARK 560-A auto-keratometer (denoted the keratometer). Main outcome measures were the intra- and interday RC of parameters used in the detection of progression of keratoconus. RESULTS: The most repeatable parameter obtained with the Pentacam was the curvature power of the central flat meridian (K1, 0.44 D [RC], -0.55 to 0.60 diopter [D] [PL]), followed by the central steep meridian (K2, 0.72 D [RC], -0.90 to 0.94 D [PL]). The interday repeatability of K1 and K2 was similar when using the keratometer (K1, 0.32 D [RC], -0.66 to 0.57 D [PL], K2, 0.93 D [RC], -1.36 to 1.08 D [PL]). The interday repeatability of the curvature power of the steepest point (Kmax, 0.84 D [RC], -0.90 to 1.11 D [PL]) would benefit from being stratified: RC = 0.44 D and PL = -0.49 to 0.67 D for Kmax < 49.0 D, and RC = 1.08 D and PL = -1.19 to 1.42 D for Kmax ≥ 49.0 D. CONCLUSIONS: The interday repeatability of measurements, single or replicate, in subjects with keratoconus should be considered when diagnosing progressive disease. K1 exhibited the best intraday repeatability. Kmax benefits from being stratified according to disease severity.


Assuntos
Córnea/patologia , Ceratocone/diagnóstico , Adulto , Paquimetria Corneana/instrumentação , Topografia da Córnea/instrumentação , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Tomografia/métodos
12.
Acta Ophthalmol ; 99(6): e929-e936, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33377591

RESUMO

PURPOSE: To describe paediatric keratoconus (KC) patients by tomographic and aberrometric characteristics at first diagnosis, in a multicentre study. METHODS: We included 278 eyes from 139 paediatric patients, with a first tomographic diagnosis (Pentacam® ) of KC prior to 18 years old. KC classification was based on the KC Index (≥ 1.07) and Topographic Keratoconus Classification (TKC ≥ 1). Patients were divided based on age ranges (14 and under and over 14 years) and gender. Statistical analysis was performed with SPSS statistics 25.0. ANOVA factor was carried out comparing to compare groups. RESULTS: 278 eyes were screened, and 230 eyes were diagnosed with paediatric KC. Mean age was 15.48 ± 2.33 (6 to 18) years. We found differences in terms of TKC (2.08 ± 0.89 and 2.38 ± 0.82, p < 0.05) and spherical aberration (-0.71 ± 0.97 and -1.07 ± 1.36, p < 0.05) among the 14 years old or under and above 14 years old groups, respectively. Overall, female paediatric KC patients presented a more severe TKC, Belin Ambrosio Display, maximum keratometry, asphericity and primary and secondary coma aberrations compared to male KC patients. We observed a correlation between CDVA and asphericity (r = 0.71, p < 0.01), as well as between CDVA and spherical aberration (r = 0.69, p < 0.01). CONCLUSION: Our findings revealed that the debut of KC is usually in a moderate to advanced stage in the paediatric population at first diagnosis, particularly in female patients. Corneal tomography should be systematically performed in children with recent onset of corneal astigmatism.


Assuntos
Aberrometria/métodos , Córnea/patologia , Topografia da Córnea/métodos , Ceratocone/diagnóstico , Acuidade Visual , Adolescente , Distribuição por Idade , Criança , Feminino , Seguimentos , Humanos , Ceratocone/complicações , Masculino , Estudos Retrospectivos
13.
PLoS One ; 15(11): e0239124, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33237913

RESUMO

PURPOSE: To investigate the corneal epithelial thickness topography with optical coherence tomography (OCT) and its relationship with vision quality in epithelial basement membrane dystrophy (EBMD). METHODS: 45 eyes of EBMD patients, 26 eyes of dry eye (DED) patients and 22 eyes of normal subjects were enrolled. All participants were subjected to 9-mm corneal epithelial mapping with OCT and vision quality was assessed with the optical quality analysis system using the objective scatter index (OSI). Central, superior, inferior, minimum, maximum, and standard deviation of epithelium thickness (Irregularity), were analysed and correlations with the OSI were calculated. RESULTS: The mean (±SD) central, inferior and maximum epithelial thicknesses of the EBMD patients (respectively, 56.4 (±8.1) µm, 58.9 (±6.4) µm, and 67.1 (±8.3) µm) were thicker compared to DED patients (P<0.05) and normal subjects (P<0.05). We found greater irregularity of epithelial thickness in EBMD (5.1±2.5 µm) compared to DED patients (2.6±1.0 µm) (P = 4.4.10-6) and normal subjects (2.1±0.7 µm) (P = 7.6.10-7). The mean OSI was worse in EBMD patients than in DED patients (P = 0.01) and compared to normal subjects (P = 0.02). The OSI correlated with the epithelial thickness irregularity (Spearman coefficient = 0.54; P = 2.65.10-5). CONCLUSIONS: The OCT pachymetry map demonstrated that EBMD patients had thicker corneal epithelium in the central and inferior region. These changes were correlated with objective measurements of vision quality. This OCT characterisation of the EMBD provides a better understanding of the epithelial behaviour in this dystrophy and its role in vision quality.


Assuntos
Membrana Basal/patologia , Síndrome de Cogan/patologia , Córnea/patologia , Epitélio Corneano/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Estudos Transversais , Síndromes do Olho Seco/patologia , Feminino , Análise de Fourier , Humanos , Ceratocone/patologia , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Adulto Jovem
14.
J Fr Ophtalmol ; 43(8): 731-741, 2020 Oct.
Artigo em Francês | MEDLINE | ID: mdl-32622634

RESUMO

The clinical evaluation of infectious keratitis takes place largely through biomicroscopic examination, which presents limitations in the evaluation of the depth of the infiltrate and the exact thickness of the cornea, whether edematous or thinned. In this study, we aim to quantify the human corneal inflammatory response in treated infectious keratitis by anterior segment optical coherence tomography (AS-OCT). Patients with infectious keratitis were recruited prospectively in the ophthalmology department of the military hospital of Rabat between November 2017 and May 2019. Over the study period, 32 patients were included. A standardized scanning protocol was used. The thickness of the infiltrate, when present, and corneal thickness in any area of thinning and any surrounding edematous areas were measured. The various thicknesses gradually decreased over the course of follow-up, providing objective evidence of therapeutic efficacy in the early stages. Improvement in corneal edema and thinning was faster in the early stage. AS-OCT scanning can be used along with slit lamp examination to quantify and objectively follow infectious keratitis.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Infecções Oculares/diagnóstico , Ceratite/diagnóstico , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Idoso , Segmento Anterior do Olho/microbiologia , Segmento Anterior do Olho/patologia , Segmento Anterior do Olho/virologia , Córnea/diagnóstico por imagem , Córnea/microbiologia , Córnea/patologia , Córnea/virologia , Efeitos Psicossociais da Doença , Progressão da Doença , Infecções Oculares/epidemiologia , Infecções Oculares/etiologia , Infecções Oculares/patologia , Feminino , Humanos , Ceratite/epidemiologia , Ceratite/etiologia , Ceratite/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Fatores de Risco , Microscopia com Lâmpada de Fenda , Adulto Jovem
15.
J Refract Surg ; 36(5): 293-299, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32396640

RESUMO

PURPOSE: To assess whether densitometry analysis appropriately monitors the development of haze in myopic patients after photorefractive keratectomy (PRK) when compared to subjective slit-lamp haze grade examinations, and whether sutureless cryo-preserved amniotic membrane reduced postoperative haze development when compared to the standard bandage contact lens. METHODS: In this retrospective cohort at the Center for Refractive Surgery, Walter Reed National Military Medical Center, a secondary analysis of prospectively collected data was performed. In the prospective study, participants underwent PRK for myopia. Postoperatively, a standard bandage contact lens was applied to the dominant eye and a sutureless cryo-preserved amniotic membrane graft to the nondominant eye. Participants were evaluated at 1, 3, and 6 months postoperatively for haze formation and corneal densitometry using slit-lamp biomicroscopy and Scheimpflug imaging, respectively. RESULTS: Densitometry measurements at 6 months postoperatively were positively and significantly associated with the presence or absence of haze as assessed by slit-lamp examination in 39 patients (78 eyes; age range: 21 to 44 years). Eyes with increased densitometry measurements had 2.3 to 3.4 times the odds (P ⩽ .014) of having clinical haze on slit-lamp examination. Eyes with the amniotic membrane graft showed a positive correlation with increased corneal densitometry throughout most layers of the cornea. CONCLUSIONS: Densitometry analysis appears to be a useful tool to supplement slit-lamp examination in monitoring haze development after PRK. The amniotic membrane failed to show a reduction in corneal densitometry in myopic eyes after PRK. [J Refract Surg. 2020;36(5):293-299.].


Assuntos
Âmnio/transplante , Opacidade da Córnea/etiologia , Opacidade da Córnea/cirurgia , Miopia/cirurgia , Ceratectomia Fotorrefrativa/efeitos adversos , Adulto , Córnea/patologia , Opacidade da Córnea/diagnóstico , Densitometria , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Microscopia com Lâmpada de Fenda , Técnicas de Sutura , Adulto Jovem
16.
Toxicol In Vitro ; 66: 104851, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32259559

RESUMO

Considering the successful employment of alternative methods for eye toxicity assessment of products for regulatory purposes, and the recent advances in Brazilian legislative scenario, which adopted the UN GHS classification system for agrochemical formulations toxicity assessment, there is an emerging demand for strategies that allow the evaluation of such products. Based on this, the present study aimed to address the applicability of a mechanistic-based defined approach for eye toxicity assessment of agrochemical formulations. It was investigated the opacity/permeability, depth and location of corneal injury in bovine cornea, and vascular events in chorioallantoic membrane induced for different Brazilian agrochemicals using a Sequential Testing Strategy (STS). Cytotoxicity induced by the agrochemical formulations was evaluated by Short Time exposure (STE) (OECD TG 491) assay (step 1), corneal injury was investigated by standard Bovine Corneal Opacity and Permeability (BCOP) (OECD TG 437) followed by histopathological evaluation (step 2), and Hen Chorionic-allantoic Membrane test (HET-CAM) was used to evaluate vascular injury (step 3). The results demonstrated that the proposed defined approach enabled a classification corresponding UN GHS classification of agrochemical formulations while minimizing the use of live animals. Therefore, this approach may be useful for categorization of agrochemicals in Brazil according to the new regulatory scenario.


Assuntos
Agroquímicos/toxicidade , Alternativas aos Testes com Animais , Membrana Corioalantoide/efeitos dos fármacos , Córnea/efeitos dos fármacos , Irritantes/toxicidade , Animais , Bioensaio , Brasil , Bovinos , Galinhas , Membrana Corioalantoide/irrigação sanguínea , Córnea/metabolismo , Córnea/patologia , Opacidade da Córnea/induzido quimicamente , Permeabilidade , Testes de Toxicidade Aguda/métodos
17.
Cornea ; 39(5): 598-604, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31868851

RESUMO

PURPOSE: To map and measure the depths of corneal neovascularization (NV) using 3-dimensional optical coherence tomography angiography (OCTA) at 2 different wavelengths. METHODS: Corneal NV of varying severity, distribution, and underlying etiology was examined. Average NV depth and vessel density were measured using 840-nm spectral-domain OCTA and 1050-nm swept-source OCTA. The OCTA results were compared with clinical slit-lamp estimation of NV depth. RESULTS: Twelve eyes with corneal NV from 12 patients were imaged with OCTA. Clinically "superficial," "midstromal," and "deep" cases had an average vessel depth of 23%, 39%, and 66% on 1050-nm OCTA, respectively. Average vessel depth on OCTA followed a statistically significant ordinal trend according to the clinical classification of vessel depth (Jonckheere-Terpstra test, P < 0.001). In 8 cases where both 840-nm OCTA and 1050-nm OCTA were acquired, there was excellent agreement in the mean vessel depth between the 2 systems (concordance correlation coefficient = 0.94, P < 0.001). The average vessel density measured by 840-nm OCTA was higher (average 1.6-fold) than that measured by 1050-nm OCTA. CONCLUSIONS: Corneal OCTA was able to map corneal NV in 3 dimensions and measure vessel depth and density. The depth of corneal NV varied between different pathologies in a manner consistent with previous pathologic studies. The measured vessel density appeared to be affected by the interscan time, which affects blood flow velocity sensitivity, and the wavelength, which affects the ability to penetrate through opacity. These findings suggest possible clinical applications of OCTA for the diagnosis of corneal pathology and quantitative monitoring of therapeutic response in patients with corneal NV.


Assuntos
Vasos Sanguíneos/patologia , Córnea/patologia , Neovascularização da Córnea/diagnóstico , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Córnea/irrigação sanguínea , Feminino , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Adulto Jovem
18.
Biomed Res Int ; 2019: 1748579, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31828090

RESUMO

PURPOSE: To investigate the pachymetry distribution of central cornea and morphologic changes in subclinical keratoconus with normal biomechanics and determine their potential benefit for the screening of very early keratoconus. METHODS: This retrospective comparative study was performed in 33 clinically unaffected eyes with normal topography and biomechanics from 33 keratoconus patients with very asymmetric ectasia (VAE-NTB; Corvis Biomechanical Index defined) and 70 truly normal eyes from 70 age-matched subjects. Corneal topographic, tomographic, and biomechanical metrics were measured using Pentacam and Corvis ST. The distance and pachymetry difference between the corneal thinnest point and the apex were defined as DTCP-Apex and DPTCP-Apex, respectively, to evaluate the pachymetry distribution within the central cornea. The discriminatory power of metrics was analysed via the receiver operating characteristic curve. A logistic regression analysis was used to establish predictive models. RESULTS: The parameters, DTCP-Apex and DPTCP-Apex, were significantly higher in VAE-NTB than those in normal eyes. For differentiating normal and VAE-NTB eyes, the Belin-Ambrósio deviation (BAD-D) showed the largest area under the curve (AUC; 0.799), followed by ARTmax (0.798), DTCP-Apex (0.771), tomography and biomechanical index (0.760), maximum pachymetry progression index (PPImax, 0.756), DPTCP-Apex (0.753), and back eccentricity (B_Ecc, 0.707) with no statistically significant differences among these AUCs. In the VAE-NTB group, the parameter B_Ecc was significantly and positively correlated with DTCP-Apex (P=0.011) and DPTCP-Apex (P=0.035), whereas the posterior elevation difference had a significant positive association with DPTCP-Apex (P=0.042). A model using the indices DTCP-Apex, B_Ecc, PPImax, and index of height asymmetry demonstrated the highest AUC of 0.846 with 91.43% specificity. CONCLUSIONS: Abnormal pachymetry distribution within the central cornea and subtle morphologic changes are detectable in subclinical keratoconus with normal biomechanics. This may improve VAE-NTB eyes detection.


Assuntos
Córnea/patologia , Ceratocone/patologia , Adulto , Área Sob a Curva , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia/métodos , Adulto Jovem
19.
J Pediatr Ophthalmol Strabismus ; 56(6): 402-406, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31743410

RESUMO

PURPOSE: To assess the early changes of corneal and lens density in a pediatric population with celiac disease. METHODS: One hundred one patients were included in this observational and prospective study. Patients with celiac disease formed the celiac disease group. Healthy individuals with no medical history formed the control group. Corneal and lens density were assessed with Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany). RESULTS: The mean lens and corneal density outcomes in all zones did not differ between groups (P > .05 for each). Maximum lens density outcome was significantly higher in the celiac disease group than in the control group (P = .028). The mean corneal density at the peripheral cornea was significantly higher in females than males in the celiac disease group (P < .05 for each). Compliance with a gluten-free diet, body mass index, and histological classification of celiac disease had no significant effect on lens and corneal density in patients with celiac disease (P > .05 for each). CONCLUSIONS: Celiac disease did not affect the mean lens and corneal density in this pediatric population, but higher maximum lens density in patients with celiac disease and higher peripheral corneal density in female patients with celiac disease may indicate early stages of ocular involvement of celiac disease. [J Pediatr Ophthalmol Strabismus. 2019;56(6):402-406.].


Assuntos
Doença Celíaca/complicações , Córnea/patologia , Doenças da Córnea/diagnóstico , Topografia da Córnea/métodos , Doenças do Cristalino/diagnóstico , Cristalino/patologia , Microscopia com Lâmpada de Fenda/métodos , Doença Celíaca/diagnóstico , Criança , Doenças da Córnea/etiologia , Progressão da Doença , Feminino , Humanos , Doenças do Cristalino/etiologia , Masculino , Estudos Prospectivos , Refração Ocular
20.
J AAPOS ; 23(3): 147.e1-147.e8, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31077787

RESUMO

PURPOSE: To investigate the effect of copper accumulation on corneal and lens clarity in children with Wilson disease (WD) compared to healthy children. METHODS: This multicenter cross-sectional study included 24 subjects with WD and 25 age-matched controls. Clinical and laboratory characteristics of the WD subjects were recorded. The Pentacam HR imaging system was used both for lens densitometry and corneal densitometry. RESULTS: Corneal densitometry values were higher in the posterior 6-10 mm (P = 0.021), posterior 10-12 mm (P < 0.001), posterior total diameter (P = 0.037), total thickness 10-12 mm (P = 0.032), and total thickness 6-10 mm zones and layers (P = 0.040) in the WD eyes than in control eyes. The lens densitometry values of zone 1 were higher in WD eyes (P < 0.001). There was a significant relationship between corneal densitometry values in the posterior 10-12 mm zones (P = 0.012; r = 0.527) and the duration of WD and liver copper content (P = 0.016; r = 0.507). A statistically significant correlation was also detected between lens densitometry values in zone 1 and WD duration (P = 0.018; r = 0.426). CONCLUSION: In this study cohort, children with WD had decreased corneal and lens clarity even in cases without Kayser-Fleischer rings and sunflower cataracts. Densitometry measurements using Scheimpflug imaging provided detection of corneal and lens involvement in the early stages of WD.


Assuntos
Córnea/patologia , Topografia da Córnea/métodos , Densitometria/métodos , Degeneração Hepatolenticular/diagnóstico , Cristalino/patologia , Adolescente , Criança , Estudos Transversais , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA