Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 291
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 13(9): e034249, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639354

RESUMO

This comprehensive review explores the incidence, pathophysiology, and management of atrial fibrillation (AF) following percutaneous closure of patent foramen ovale (PFO). Although AF is considered a common adverse event post PFO closure, its incidence, estimated at <5%, varies based on monitoring methods. The review delves into the challenging task of precisely estimating AF incidence, given subclinical AF and diverse diagnostic approaches. Notably, a temporal pattern emerges, with peak incidence around the 14th day after closure and a subsequent decline after the 45th day, mimicking general population AF trends. The pathophysiological mechanisms behind post PFO closure AF remain elusive, with proposed factors including local irritation, device-related interference, tissue stretch, and nickel hypersensitivity. Management considerations encompass rhythm control, with flecainide showing promise, and anticoagulation tailored to individual risk profiles. The authors advocate for a personalized approach, weighing factors like age, comorbidities, and device characteristics. Notably, postclosure AF is generally considered benign, often resolving spontaneously within 45 days, minimizing thromboembolic risks. Further studies are required to refine understanding and provide evidence-based guidelines.


Assuntos
Fibrilação Atrial , Forame Oval Patente , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Forame Oval Patente/epidemiologia , Forame Oval Patente/fisiopatologia , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Incidência , Cateterismo Cardíaco/efeitos adversos , Fatores de Risco , Dispositivo para Oclusão Septal/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia
2.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662126

RESUMO

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Incidência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Multidetectores
3.
Catheter Cardiovasc Interv ; 103(4): 580-586, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38353500

RESUMO

BACKGROUND: Use of alternate access for complex neonatal interventions has gained acceptance with carotid and axillary artery access being used for ductal and aortic interventions. METHODS: This study was a retrospective, single-center study at Cincinnati Children's Hospital Medical Center. The study included infants, aged ≤90 days, who underwent cardiac catheterization with either carotid or axillary artery access between 2013 and 2022. Data encompassing demographics, clinical information, catheterization data, and the incidence of pseudoaneurysm as a procedural complication were collected. RESULTS: Among 29 young infants (20 males, 69%), 4 out of 15 patients (27%) who underwent the carotid approach developed pseudoaneurysms, while 1 out of 14 patients (7.1%) who underwent the axillary approach developed one. Two patients required transcatheter intervention due to enlargement of pseudoaneurysms, involving the placement of transarterial flow-diverting stent and occlusion of left common carotid artery. Longer sheath in-to-out time (135 vs. 77 min, p = 0.001), and higher closing activated clotting times (ACT) (268 vs. 197 s, p = 0.021) were observed among patients with pseudoaneurysms compared to those without. CONCLUSIONS: Young infants with alternative access via the carotid and axillary arteries may be at risk of pseudoaneurysm formation during longer procedures and with higher ACTs for closure. Ultrasound-guided compression can be employed to prevent the progression and in resolution of these lesions.


Assuntos
Falso Aneurisma , Masculino , Recém-Nascido , Lactente , Criança , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/epidemiologia , Falso Aneurisma/etiologia , Artéria Axilar/diagnóstico por imagem , Estudos Retrospectivos , Incidência , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Fatores de Risco , Artéria Femoral
4.
J Cardiovasc Electrophysiol ; 35(3): 389-398, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38192059

RESUMO

INTRODUCTION: This study was performed to explore the diagnostic value of cardiac computed tomography angiography (CCTA) for endothelial insufficiency (EIS) of a left atrial appendage (LAA) disc-like occluder. METHODS: Fifty-nine patients with nonvalvular atrial fibrillation who underwent placement of an LAA disc-like occluder (LAmbre; Lifetech Scientific) in our hospital were retrospectively analyzed. Patients who were found to have contrast agent entering the LAA at the 3-month postoperative CCTA examination underwent Hounsfield unit (HU) measurement of the LAA and construction of a three-dimensional (3D) model of the device for preliminary discernment between peri-device leakage (PDL) and EIS. These patients were then further examined by transesophageal echocardiography (TEE) to check for concordance with the computed tomography (CT) findings. According to the CT and TEE results, all patients were divided into the PDL group, total endothelialization group, and EIS group. The endothelial conditions and other implantation-related results were also tracked at the 6-month follow-up. RESULTS: All 59 patients underwent successful implantation of the LAmbre LAA closure device with no severe adverse events during the procedure. Thirty-five patients were found to have contrast agent entering the LAA at the 3-month postoperative CCTA follow-up. Based on the CT HU measurement and the 3D construction analysis results, these 35 patients were divided into the PDL group (19 patients) and the EIS group (16 patients). In the PDL group, the contrast agent infiltrated from the shoulder along the periphery of the occluder on two-dimensional (2D) CT images, and the 3D model showed a gap between the LAA and the device cover. However, the CCTA images of the other 16 patients in the EIS group showed that the contrast agent in the occluder on the 2D CTA images and 3D construction model confirmed the absence of a gap between the LAA and the device cover. TEE confirmed all of the CT results. The 6-month follow-up results showed that 14 of 19 patients in the EIS group achieved total endothelialization, whereas this number in the PDL group was only five of 19 patients. CONCLUSION: CCTA can replace TEE for examination of the endothelialization status, and patients with EIS have a higher chance of endothelialization than patients with PDL.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Angiografia por Tomografia Computadorizada/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Meios de Contraste , Tomografia Computadorizada por Raios X , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ecocardiografia Transesofagiana/métodos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento
5.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37393190

RESUMO

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , AVC Isquêmico/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia
6.
J Am Coll Cardiol ; 83(2): 317-330, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37879489

RESUMO

BACKGROUND: Evidence is limited regarding patient outcomes comparing redo surgical mitral valve replacement (redo SMVR) vs transcatheter mitral valve replacement (TMVR) for failed prostheses. OBJECTIVES: The goal of this study was to compare the outcomes of redo SMVR vs TMVR in patients with failed prostheses, as well as evaluate the association between case volume and outcomes. METHODS: Medicare beneficiaries aged ≥65 years who underwent redo SMVR or TMVR for failed mitral prostheses between 2016 and 2020 were included. The primary endpoint was mid-term (up to 3 years) major adverse cardiovascular events (MACE), including all-cause death, heart failure rehospitalization, stroke, or reintervention. Propensity score-matched analysis was used. RESULTS: A total of 4,293 patients were included (redo SMVR: 64%; TMVR: 36%). TMVR recipients were older, with a higher comorbidity burden. In matched cohort (n = 1,317 in each group), mid-term risk of MACE was similar (adjusted HR: 0.92; 95% CI: 0.80-1.04; P = 0.2). However, landmark analysis revealed a lower risk of MACE with TMVR in the first 6 months (adjusted HR: 0.75; 95% CI: 0.63-0.88; P < 0.001) albeit with a higher risk beyond 6 months (adjusted HR: 1.28; 95% CI: 1.04-1.58; P = 0.02). Increasing procedural volume was associated with decreased risk of mid-term MACE after redo SMVR (P = 0.001) but not after TMVR (P = 0.3). CONCLUSIONS: In this large cohort of Medicare beneficiaries with failed mitral prostheses, outcomes were similar between redo SMVR and TMVR at 3 years, with TMVR showing a lower initial risk but a higher risk of MACE after 6 months. These findings highlight the importance of striking a balance between surgical risk, anticipated longevity, and hospital expertise when selecting interventions.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Idoso , Estados Unidos/epidemiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Reoperação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Medicare , Próteses e Implantes , Resultado do Tratamento
7.
Circ Cardiovasc Qual Outcomes ; 16(12): e010063, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38050754

RESUMO

BACKGROUND: Canadian data suggest that patients of lower socioeconomic status with acute myocardial infarction receive less beneficial therapy and have worse clinical outcomes, raising questions regarding care disparities even in universal health care systems. We assessed the contemporary association of marginalization with clinical outcomes and health services use. METHODS: Using clinical and administrative databases in Ontario, Canada, we conducted a population-based study of patients aged ≥65 years hospitalized for their first acute myocardial infarction between April 1, 2010 and March 1, 2019. Patients receiving cardiac catheterization and surviving 7 days postdischarge were included. Our primary exposure was neighborhood-level marginalization, a multidimensional socioeconomic status metric. Neighborhoods were categorized by quintile from Q1 (least marginalized) to Q5 (most marginalized). Our primary outcome was all-cause mortality. A proportional hazards regression model with a robust variance estimator was used to quantify the association of marginalization with outcomes, adjusting for risk factors, comorbidities, disease severity, and regional cardiologist supply. RESULTS: Among 53 841 patients (median age, 75 years; 39.1% female) from 20 640 neighborhoods, crude 1- and 3-year mortality rates were 7.7% and 17.2%, respectively. Patients in Q5 had no significant difference in 1-year mortality (hazard ratio [HR], 1.08 [95% CI, 0.95-1.22]), but greater mortality over 3 years (HR, 1.13 [95% CI, 1.03-1.22]) compared with Q1. Over 1 year, we observed differences between Q1 and Q5 in visits to primary care physicians (Q1, 96.7%; Q5, 93.7%) and cardiologists (Q1, 82.6%; Q5, 72.6%), as well as diagnostic testing. There were no differences in secondary prevention medications dispensed or medication adherence at 1 year. CONCLUSIONS: In older patients with acute myocardial infarction who survived to hospital discharge, those residing in the most marginalized neighborhoods had a greater long-term risk of mortality, less specialist care, and fewer diagnostic tests. Yet, there were no differences across socioeconomic status in prescription medication use and adherence.


Assuntos
Infarto do Miocárdio , Alta do Paciente , Humanos , Feminino , Idoso , Masculino , Assistência ao Convalescente , Infarto do Miocárdio/terapia , Infarto do Miocárdio/tratamento farmacológico , Ontário/epidemiologia , Acessibilidade aos Serviços de Saúde , Hospitais , Cateterismo Cardíaco/efeitos adversos
8.
Nephrology (Carlton) ; 28(11): 588-596, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37619965

RESUMO

AIM: Cardiac biomarkers' predictive value of contrast-associated acute kidney injury (CA-AKI) remains unclear. We analysed whether creatine kinase isoenzyme-MB (CKMB), cardiac troponin I (cTnI) and preoperative N-terminal pro-brain natriuretic peptide (NT-proBNP) are tied to CA-AKI patients undergoing cardiac catheterization. METHODS: In the multi-center study, we included 3553 people underwent cardiac catheterization for analysis. CA-AKI was defined as the absolute increase of over 0.3 mg/dL or an increase of more than 50% compared with the baseline serum creatinine within 48 hours following cardiac catheterization. Logistic regression model and receiver operating characteristic (ROC) curves were used to examine the association between cardiac biomarkers and CA-AKI and the efficacy of Mehran risk score (MRS) model on CA-AKI prediction with and without cardiac biomarkers. RESULTS: Among 3553 people, 200 people eventually developed CA-AKI. The logistic regression model showed that log10 CKMB (odds ratio (OR): 1.97, 95%CI:1.51-2.57, p < .001), cTnI (OR: 1.03, 95%CI: 1.02-1.04, p < .001) and log10 NT-proBNP (OR: 3.19, 95%CI: 2.46-4.17, p < .001) were independent predictors of CA-AKI. The ROC curve demonstrated that area under the curve (AUC) of MRS was 0.733. CKMB, cTnI and NT-proBNP all significantly improved the AUC value in combination with MRS model. (NT-proBNP: 0.798, p < .001; CKMB: 0.758, p = .003; cTnI: 0.755, p = .002), among which the NT-proBNP had the best predictive efficacy improvement. CONCLUSION: Cardiac biomarkers of CKMB, cTnI and NT-proBNP are all independently associated with CA-AKI among patients undergoing cardiac catheterization while NT-proBNP remains the best indicator. Adding CKMB, cTnI and NT-proBNP to MRS improved the prognostic efficacy and may be considered effective tools to predict the risk of CA-AKI in clinical practice.


Assuntos
Injúria Renal Aguda , Humanos , Estudos Retrospectivos , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Prognóstico , Medição de Risco , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Cateterismo Cardíaco/efeitos adversos , Curva ROC , Biomarcadores
9.
JACC Cardiovasc Interv ; 16(6): 627-642, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36990553

RESUMO

Left atrial appendage occlusion is an increasingly adopted stroke prevention strategy in patients with atrial fibrillation. However, peridevice leaks after the procedure are not infrequent and have recently been shown to confer a higher risk for subsequent ischemic events. In this paper, the authors review the available research on the frequency, mechanisms, clinical significance, and management of peridevice leak after percutaneous left atrial appendage occlusion.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Incidência , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Cateterismo Cardíaco/efeitos adversos
11.
J Am Heart Assoc ; 12(4): e027504, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36752231

RESUMO

Background The current standard of care for the treatment of patients with primary mitral regurgitation (MR) is surgical mitral valve repair. Transcatheter edge-to-edge repair with the MitraClip device provides a less invasive treatment option for patients with both primary and secondary MR. Worldwide, >150 000 patients have been treated with the MitraClip device. However, in the United States, MitraClip is approved for use only in primary patients with MR who are at high or prohibitive risk for mitral valve surgery. The REPAIR MR (Percutaneous MitraClip Device or Surgical Mitral Valve Repair in Patients With Primary Mitral Regurgitation Who Are Candidates for Surgery) trial is designed to compare early and late outcomes associated with transcatheter edge-to-edge repair with the MitraClip and surgical repair of primary MR in older or moderate surgical risk patients. Methods and Results The REPAIR MR trial is a prospective, randomized, parallel-controlled, open-label multicenter, noninferiority trial for the treatment of severe primary MR (verified by an independent echocardiographic core laboratory). Patients with severe MR and indications for surgery because of symptoms (New York Heart Association class II-IV), or without symptoms with left ventricular ejection fraction ≤60%, pulmonary artery systolic pressure >50 mm Hg, or left ventricular end-systolic diameter ≥40 mm are eligible for the trial provided they meet the moderate surgical risk criteria as follows: (1) ≥75 years of age, or (2) if <75 years of age, then the subject has a Society of Thoracic Surgeons Predicted Risk Of Mortality score of ≥2% for mitral repair (or Society of Thoracic Surgeons replacement score of ≥4%), or the presence of a comorbidity that may introduce a surgery-specific risk. The local surgeon must determine that the mitral valve can be surgically repaired. Additionally, an independent eligibility committee will confirm that the MR can be reduced to mild or less with both the MitraClip and surgical mitral valve repair with a high degree of certainty. A total of 500 eligible subjects will be randomized in a 1:1 ratio to receive the MitraClip device or to undergo surgical mitral valve repair (control group). There are 2 co-primary end points for the trial, both of which will be evaluated at 2 years. Each subject will be followed for 10 years after enrollment. The study has received approval from both the Food and Drug Administration and the Centers for Medicare and Medicaid Services, and enrolled its first subject in July 2020. Conclusions The REPAIR MR trial will determine the safety and effectiveness of transcatheter edge-to-edge repair with the MitraClip in patients with primary MR who are at moderate surgical risk and are candidates for surgical MV repair. The trial will generate contemporary comparative clinical evidence for the MitraClip device and surgical MV repair. Registration https://clinicaltrials.gov/ct2/show/NCT04198870; NCT04198870.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Idoso , Estados Unidos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Volume Sistólico , Estudos Prospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Medicare , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/efeitos adversos
12.
World J Pediatr Congenit Heart Surg ; 13(6): 716-722, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36300270

RESUMO

Background: Unrepaired truncus arteriosus (TA) carries poor prognosis due to complications of unrestricted pulmonary flow, truncal valve insufficiency, and pulmonary vascular disease. Currently, the hemodynamic profile of adults late after TA repair is unknown. We reviewed the hemodynamics, prevalence, and pathophysiology of pulmonary hypertension (PH) in this population. Methods: Eighteen adult patients with repaired TA who underwent cardiac catheterization at Mayo Clinic, MN, between 1997 and 2021 were identified. PH was defined as either precapillary (mean pulmonary artery pressure [mPAP] ≥25 mm Hg, pulmonary artery wedge pressure [PAWP] ≤15 mm Hg, and pulmonary vascular resistance [PVR] >3 Wood units), isolated postcapillary (mPAP ≥25, PAWP >15, PVR ≤3), or combined (mPAP ≥25, PAWP >15, and PVR >3). Diastolic pressure and transpulmonary gradients were used as ancillary data for classification. Results: Mean age at catheterization was 34 ± 10 years. Mean right ventricular (RV) systolic pressure was 82 ± 22.6 mm Hg, mean right and left mPAPs 28.1 ± 16.2 and 27.9 ± 11.9 mm Hg, respectively. Seven patients (41.2%) had PAWP >15 mm Hg and, among those undergoing arterial catheterization, 7 (53.8%) had a left ventricular (LV) end-diastolic pressure >15 mm Hg. PH was diagnosed in 13 patients (72.2%): 6 (33.3%) precapillary, 4 (22.2%) isolated postcapillary, and 3 (16.7%) combined. PAWP >15 mm Hg was associated with male sex (P = .049),

Assuntos
Hipertensão Pulmonar , Persistência do Tronco Arterial , Adulto , Humanos , Masculino , Adulto Jovem , Tronco Arterial , Pressão Propulsora Pulmonar/fisiologia , Hemodinâmica , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Hipertensão Pulmonar/diagnóstico , Resistência Vascular/fisiologia , Cateterismo Cardíaco/efeitos adversos , Persistência do Tronco Arterial/cirurgia , Persistência do Tronco Arterial/complicações
13.
J Pediatr ; 246: 56-63.e3, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35430250

RESUMO

OBJECTIVE: To evaluate the cost-utility of catheterization-obligate treatment in preterm infants with pulmonary hypertension, as compared with empiric initiation of sildenafil based on echocardiographic findings alone. STUDY DESIGN: A Markov state transition model was constructed to simulate the clinical scenario of a preterm infant with echocardiographic evidence of pulmonary hypertension associated with bronchopulmonary dysplasia (BPD) and without congenital heart disease under consideration for the initiation of pulmonary vasodilator therapy via one of two modeled treatment strategies-empiric or catheterization-obligate. Transitional probabilities, costs and utilities were extracted from the literature. Forecast quality-adjusted life-years was the metric for strategy effectiveness. Sensitivity analyses for each variable were performed. A 1000-patient Monte Carlo microsimulation was used to test the durability of our findings. RESULTS: The catheterization-obligate strategy resulted in an increased cost of $10 778 and 0.02 fewer quality-adjusted life-years compared with the empiric treatment strategy. Empiric treatment remained the more cost-effective paradigm across all scenarios modeled through one-way sensitivity analyses and the Monte Carlo microsimulation (cost-effective in 98% of cases). CONCLUSIONS: Empiric treatment with sildenafil in infants with pulmonary hypertension associated with BPD is a superior strategy with both decreased costs and increased effectiveness when compared with catheterization-obligate treatment. These findings suggest that foregoing catheterization before the initiation of sildenafil is a reasonable strategy in preterm infants with uncomplicated pulmonary hypertension associated with BPD.


Assuntos
Displasia Broncopulmonar , Hipertensão Pulmonar , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/terapia , Cateterismo Cardíaco/efeitos adversos , Humanos , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/etiologia , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Citrato de Sildenafila
14.
Cardiovasc Revasc Med ; 41: 35-46, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35140053

RESUMO

BACKGROUND/PURPOSE: Device-related thrombosis (DRT) is one of the greatest challenges of transcatheter left atrial appendage device occlusion. Due to the invasive nature of transesophageal echocardiography (TEE), cardiac computed tomography angiography (CCTA) is being increasingly utilized in several centers for assessing adequate left atrial appendage closure and monitoring for DRT. There is a paucity of data regarding the standardized definition of DRT on CCTA for the WATCHMAN FLX™ device. METHODS/MATERIALS: A retrospective review was conducted on 43 patients receiving WATCHMAN FLX™ device implantation with CCTA performed at the first follow-up at our institution. A comparative review of DRT predictors was performed on 10 patients who had both CCTA and TEE at the time of follow-up. RESULTS: Hypoattenuated thickening (HAT) was a common finding on CCTA and was noted to be present in 95.35% of the patients. The combination of a large device size, peridevice gap >4 mm, and HAT located on the device gutter and 1 shoulder were characteristics present on CCTA observed in 2 patients with confirmed DRT on TEE. CONCLUSION: CCTA is a noninvasive imaging modality for DRT monitoring, with guidelines still in development. We report potential predictors of DRT on CCTA. Additional studies are needed to further determine standardized parameters for DRT detection on CCTA and the significance of HAT with multimodality correlation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Trombose , Apêndice Atrial/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Estudos Observacionais como Assunto , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Resultado do Tratamento
15.
JACC Cardiovasc Interv ; 15(2): 165-175, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057987

RESUMO

OBJECTIVES: The aim of this study was to compare the immediate and midterm echocardiographic performance of the Melody (Medtronic Inc) and Sapien (Edwards Lifesciences Inc) valves after transcatheter pulmonary valve replacement (TPVR) in native and conduit right ventricular outflow tracts (RVOTs). BACKGROUND: TPVR is now a common procedure, but limited data exist comparing postimplantation echocardiographic findings between Melody and Sapien valves. METHODS: This was a single-institution retrospective cohort study of all patients who underwent successful TPVR from 2011 to 2020. Patient demographics, procedural details, and immediate and midterm echocardiographic findings were collected and compared between valve types using the Wilcoxon rank sum, chi-square, or Fisher exact test as appropriate. Subgroups were analyzed individually and were adjusted for multiple comparisons using the Bonferroni method. RESULTS: A total of 328 patients underwent successful TPVR (Melody: n = 202, Sapien: n = 126). The groups had a similar baseline age, weight, and diagnosis. The most common indications for TPVR were pulmonary stenosis (32.2%) or mixed disease (46%) in the Melody group and pulmonary insufficiency in the Sapien group (52.4%) (P < 0.001). Sapien valves were more often placed in native RVOTs (43.7% vs 18.8%; P < 0.001). The discharge and follow-up mean and peak Doppler gradients were similar between the Melody and Sapien groups. Valves implanted in native RVOTs had significantly lower postimplantation gradients at each follow-up period. CONCLUSIONS: Echocardiographic performance after TPVR was generally acceptable and similar when comparing Melody and Sapien valves despite differences in the indication and anatomy in each group. The peak and mean gradients were lower in transcatheter valves implanted in native RVOTs compared with those implanted in conduits or bioprosthetic valves.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
16.
Lab Anim (NY) ; 51(2): 46-67, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35087256

RESUMO

Over the past years, the use of large animals has become increasingly interesting in translational research, to bridge the gap between basic research in rodents and targeted therapies in humans. Pigs are highly valued in cardiovascular research because of their anatomical, hemodynamic and electrophysiological features, which closely resemble those of humans. For studying these aspects in swine, cardiac catheterization techniques are essential procedures. Although cardiac catheterization seems to be comparatively easy in pigs as human equipment can be used to perform the procedure, there are some pitfalls. Here we provide a detailed protocol to guide the reader through different aspects of cardiac catheterization in pigs. We suggest an approach for safe intubation and extubation, provide tips for perioperative and postoperative management of the animals and guide the reader through different experimental steps, including sheath insertion. We also describe the procedures for basic electrophysiological assessment of conduction properties and atrial fibrillation induction, hemodynamic assessment via pressure-volume loops, right heart and left heart catheterization and the development of a myocardial infarction model by balloon occlusion. This protocol was developed in Landrace pigs and can be adapted to other pig breeds or other large animal species. This protocol requires approximately six and a half working hours in total and should be performed by researchers with previous experience in large animal experimentation and in the presence of a veterinarian.


Assuntos
Cardiopatias , Infarto do Miocárdio , Animais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/veterinária , Modelos Animais de Doenças , Cardiopatias/complicações , Infarto do Miocárdio/etiologia , Suínos
17.
Med Sci Monit ; 27: e930596, 2021 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-34433799

RESUMO

BACKGROUND The aim of this study was to measure sleep quality among patients who underwent infective endocarditis (IE) surgery and identify the risk factors involved in sleep disorders. MATERIAL AND METHODS In this study, we used actigraphy, the Pittsburgh Sleep Quality Index (PSQI), and Epworth Sleep Scale (ESS) to determine the clinical characteristics of sleep disorders in 116 patients with IE who were in rehabilitation after surgery. RESULTS Our results showed that 46 (39.7%) patients had sleep efficiency over 85%, while 70 (60.3%) patients had sleep efficiency below 85%. The correlation analysis showed that sleep efficiency was related to the duration of the disease, with a longer duration leading to lower sleep efficiency (P=0.031). The sleep efficiency of patients with IE following surgery was also affected by alcohol consumption; however, surprisingly, patients with "heavy" alcohol consumption had higher sleep efficiency (P=0.030). We found a significant correlation between sleep efficiency and postoperative interleukin-6 (IL) levels, C-reactive protein (CRP) levels, and preoperative erythrocyte sedimentation rate (P<0.05). No significant correlation was found between brain natriuretic peptide levels and sleep efficiency, PSQI score, or ESS score. Postoperative hemoglobin (Hb) level was associated with sleep efficiency (R=0.194, P=0.036), but there was no statistically significant correlation between the PSQI and ESS scores. Postoperative alanine transaminase (ALT) showed a significant negative correlation with sleep efficiency (R=-0.27, P=0.003). CONCLUSIONS We found a high prevalence of sleep disorders in patients with IE along with an increase in inflammatory factors, including postoperative IL-6, CRP, ALT, and Hb levels.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/patologia , Transtornos do Sono-Vigília/patologia , Adulto , Valva Aórtica/lesões , Endocardite/patologia , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Transtornos do Sono-Vigília/etiologia , Inquéritos e Questionários
18.
Catheter Cardiovasc Interv ; 98(7): 1404-1412, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406713

RESUMO

OBJECTIVES: To investigate whether the integrative echocardiographic criteria used in the cardiovascular outcomes assessment of the mitraclip percutaneous therapy (COAPT) for heart failure patients with functional mitral regurgitation study predict outcomes after edge-to-edge trancatheter mitral valve repair (TMVr) for the treatment of secondary mitral regurgitation (SMR). BACKGROUND: Two randomized controlled trials comparing TMVr to medical treatment reported conflicting findings. Differences in patient selection criteria may have contributed to these diverging results. METHODS: Patients undergoing TMVr were stratified following the integrative COAPT echocardiographic criteria in noneligible and eligible patients who were further classified into three tiers according to effective regurgitant orifice (EROA) (Tier 1: EROA ≥ 0.3cm2 ; Tier 2: EROA 0.2cm2 and 0.29cm2 ; Tier 3: EROA<0.2cm2 ) combined with several other severity criteria. We assessed between group differences in all-cause mortality, successful SMR reduction, and symptom relief from baseline to 2-year follow-up. RESULTS: Between March 2011 and March 2018, 138 patients (mean age 75 years) satisfying the inclusion criteria underwent TMVr for treatment of symptomatic SMR. The mean EROA area was 0.35 ± 0.17 mm2 . Ten patients (7%) died within 30 days, 29 (21%) within 12 months, and 41 (30%) within 2 years. After stratification according to the COAPT echocardiographic criteria that were fulfilled in 72% of the studied population, Tier 2 patients (45%), as well as noneligible patients (38%) had a higher mortality rate compared to those in Tier 1 (19%). CONCLUSIONS: SMR patients stratified into tiers according to the COAPT integrative echocardiographic criteria have diverging prognostic and symptomatic benefit after edge-to-edge TMVr.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
19.
J Stroke Cerebrovasc Dis ; 30(8): 105884, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34153592

RESUMO

OBJECTIVES: Patent foramen ovale is a hemodynamically insignificant interatrial communication that may cause ischemic stroke. Percutaneous patent foramen ovale closure reduces the risk for recurrent ischemic stroke in patients with a history of cryptogenic ischemic stroke. This study evaluated the cost-effectiveness of patent foramen ovale closure against medical therapy in patients after their first cryptogenic ischemic stroke in Japan. MATERIALS AND METHODS: The cost-effectiveness of patent foramen ovale closure compared with medical therapy was evaluated using the Markov model. The target patients started with patent foramen ovale closure or medical therapy for preventing secondary ischemic stroke under a stable state. Quality-adjusted life year was used as the outcome of effectiveness, and the analysis was conducted with a discount rate of 2% applied to both cost and effectiveness. The results of a multicenter open-label randomized controlled trial (RESPECT trial) evaluating patent foramen ovale closure using the Amplatzer™ PFO Occluder were used as clinical evidence. Cost-effectiveness was evaluated using the incremental cost-effectiveness ratio. It was evaluated as cost-effective if it was lower than 5 million JPY/ quality-adjusted life year. RESULTS: Patent foramen ovale closure was dominant over medical therapy by 2.53 quality-adjusted life years and an estimated cost reduction of 2,353,926 JPY. The probability of patent foramen ovale closure being dominant was 82.9%. CONCLUSIONS: Patent foramen ovale closure was dominant over medical therapy for preventing secondary ischemic stroke in patients with cryptogenic ischemic stroke.


Assuntos
Cateterismo Cardíaco/economia , Forame Oval Patente/economia , Forame Oval Patente/terapia , Custos de Cuidados de Saúde , AVC Isquêmico/economia , AVC Isquêmico/prevenção & controle , Dispositivo para Oclusão Septal/economia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Redução de Custos , Análise Custo-Benefício , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/etiologia , Japão , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Modelos Econômicos , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
20.
J Am Heart Assoc ; 10(8): e019882, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33821669

RESUMO

Background Edge-to-edge transcatheter mitral valve repair as salvage therapy in high surgical risk patients with severe mitral regurgitation presenting with cardiogenic shock (CS) has been described in small case series, but large clinical results have not been reported. This study aimed to evaluate outcomes of transcatheter mitral valve repair with MitraClip in patients with mitral regurgitation and CS using a large national database. Methods and Results From January 2014 to March 2019, we identified hospitalizations for CS in patients with mitral valve disease using data from Centers for Medicare and Medicaid Services. Those with a prior surgical or percutaneous mitral valve intervention were excluded. We compared survival between patients who underwent MitraClip during the index hospitalization and those who did not using propensity-matched analysis. The analysis included 38 166 patients (mean age, 71±11 years, 41.6% women) of whom 622 (1.6%) underwent MitraClip. MitraClip was increasingly used during CS hospitalizations over the study period (P<0.001). After matching, patients receiving MitraClip had significantly lower in-hospital mortality (odds ratio, 0.6; 95% CI, 0.47-0.77; P<0.001) and 1-year mortality (hazard ratio, 0.76; 95% CI, 0.65-0.88; P<0.001) compared with those without MitraClip. The survival benefit associated with MitraClip was consistent across subgroups of interest, with the exception of patients requiring acute mechanical circulatory support or hemodialysis at index. Conclusions In patients with mitral regurgitation presenting with CS, use of MitraClip is increasing and associated with greater in-hospital and 1-year survival. Further studies are warranted to optimize patient selection and procedure timing for those receiving MitraClip as a treatment option in CS.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Medição de Risco/métodos , Choque Cardiogênico/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Medicare/estatística & dados numéricos , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Vigilância da População , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA