Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30686483

RESUMO

INTRODUCTION AND OBJECTIVES: The objective of this paper was to show our experience and considerations when quantifying hyoid bone displacement and to observe its correlation with the qualitative scales that evaluate dysphagia. METHODS: Hyoid displacement was assessed using the method described by Molfenter and Steele's group in 2014 in a series of 14 patients affected by oropharyngeal dysphagia. The degree of dysphagia was also qualitatively assessed with the Rosenbek Penetration and Aspiration Scale (PAS) of 1996 and with the Functional Oral Intake Scale (FOIS) of Crary of 2005. All assessments were done before and after treatment. RESULTS: All patients increased their hyoid bone total displacement after the treatment. These variations were highly correlated with the variations in the PAS scale with aspiration or penetration. However, the variations of hyoid bone displacement did not correlate with the FOIS scale. CONCLUSIONS: The improvement in total hyoid bone displacement is a clinical indicator of improved aspiration of patients suffering dysphagia. However, the improvement of this displacement is not related to the oral intake tolerance of the patients.


Assuntos
Transtornos de Deglutição/fisiopatologia , Osso Hioide/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Lesões Encefálicas/complicações , Deglutição/fisiologia , Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Feminino , Fluoroscopia/métodos , Humanos , Osso Hioide/diagnóstico por imagem , Complicações Intraoperatórias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Movimento , Músculos Faríngeos/fisiopatologia , Lesões por Radiação/fisiopatologia , Índice de Gravidade de Doença , Acidente Vascular Cerebral/complicações , Ultrassonografia , Gravação em Vídeo
2.
J Invest Surg ; 31(6): 523-528, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28952826

RESUMO

PURPOSE: The purpose of this work is to assess the predictive value, for fluid responsiveness (FR), of the inferior vena cava distensibility index (IVC-DI) and internal jugular vein distensibility index (IJV-DI) in pediatric surgical patients. MATERIAL AND METHODS: Prior to being placed under general anesthesia, 24 surgical patients were enrolled. Baseline parameters were recorded with the patient in the semirecumbent position (Stage 1). Next, the passive leg raising (PLR) maneuver was carried out and a second measurement was recorded (Stage 2). Patients with an increase in the cardiac index (CI) of >10%, induced by PLR, were considered to be responders (R), otherwise they were classified as nonresponders (NR). At both stages, CI and DI of the IVC and IJV were measured. RESULTS: Responders had higher IVC-DI and IVJ-DI than NR in stage 1 (both p <.001). In stage 2, IVC-DI and IJV-DI were not different in R and NR groups (p =.164, p =.201). Utilizing cut-off values of > 22.7% for IVC-DI and > 25% for IJV-DI, these parameters had positive correlation coefficients, both in R and NR of, respectively, 0.626 and 0.929. CONCLUSIONS: The IVC-DI predicts FR in anesthetized pediatric patients and correlates well with the IJV-DI; both may be used as prediction markers of FR in children.


Assuntos
Desidratação/diagnóstico , Hidratação/métodos , Complicações Intraoperatórias/diagnóstico , Monitorização Intraoperatória/métodos , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Determinação do Volume Sanguíneo/métodos , Criança , Pré-Escolar , Desidratação/etiologia , Desidratação/fisiopatologia , Desidratação/prevenção & controle , Feminino , Hidratação/efeitos adversos , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiologia , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia/métodos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiologia
3.
Anesthesiology ; 121(4): 719-29, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25089641

RESUMO

BACKGROUND: Left atrial pressure and its surrogate, pulmonary capillary wedge pressure (PCWP), are important for determining diastolic function. The role of transthoracic echocardiography (TTE) in assessing diastolic function is well established in awake subjects. The objective was to assess the accuracy of predicting PCWP by TTE and transesophageal echocardiography (TEE) during coronary artery surgery. METHODS: In 27 adult patients undergoing on-pump coronary artery surgery, simultaneous echocardiographic and hemodynamic measurements were obtained immediately before anesthesia (TTE), after anesthesia and mechanical ventilation (TTE and TEE), during conduit harvest (TEE), and after separation from cardiopulmonary bypass (TEE). RESULTS: Twenty patients had an ejection fraction (EF) of 0.5 or greater. With the exception of E/e' and S/D ratios, echocardiographic values changed over the echocardiographic studies. In patients with low EF, E velocity, deceleration time, pulmonary vein D, S/D, and E/e' ratios correlated well with PCWP before anesthesia. After induction of anesthesia using TTE or TEE, correlations were poor. In normal EF patients, correlations were poor for both TEE and TTE at all five stages. The sensitivity and specificity of echocardiographic values were not high enough to predict raised PCWP except for a fixed curve pattern of interatrial septum (area under the curve 0.89 for PCWP ≥ 17, and 0.98 for ≥ 18 mmHg) and S/D less than 1 (area under the curve 0.74 for PCWP ≥ 17, and 0.78 for ≥ 18 mmHg). CONCLUSION: Doppler assessment of PCWP was neither sensitive nor specific enough to be clinically useful in anesthetized patients with mechanical ventilation. The fixed curve pattern of the interatrial septum was the best predictor of raised PCWP.


Assuntos
Septo Interatrial/diagnóstico por imagem , Septo Interatrial/fisiologia , Ponte de Artéria Coronária/efeitos adversos , Hipertensão Pulmonar/diagnóstico por imagem , Complicações Intraoperatórias/diagnóstico por imagem , Pressão Propulsora Pulmonar/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte de Artéria Coronária/métodos , Ecocardiografia Doppler/métodos , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Complicações Intraoperatórias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Volume Sistólico/fisiologia
4.
Pediatr Cardiol ; 35(1): 140-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23900744

RESUMO

Continued advancements in congenital cardiac catheterization and interventions have resulted in increased patient and procedural complexity. Anticipation of life-threatening events and required rescue measures is a critical component to preprocedural preparation. We sought to determine the incidence and nature of life-threatening adverse events in congenital and pediatric cardiac catheterization, risk factors, and resources necessary to anticipate and manage events. Data from 8905 cases performed at the 8 participating institutions of the Congenital Cardiac Catheterization Project on Outcomes were captured between 2007 and 2010 [median 1,095/site (range 133-3,802)]. The incidence of all life-threatening events was 2.1 % [95 % confidence interval (CI) 1.8-2.4 %], whereas mortality was 0.28 % (95 % CI 0.18-0.41 %). Fifty-seven life-threatening events required cardiopulmonary resuscitation, whereas 9 % required extracorporeal membrane oxygenation. Use of a risk adjustment model showed that age <1 year [odd ratio (OR) 1.9, 95 % CI 1.4-2.7, p < 0.001], hemodynamic vulnerability (OR 1.6, 95 % CI 1.1-2.3, p < 0.01), and procedure risk (category 3: OR 2.3, 95 % CI 1.3-4.1; category 4: OR 4.2, 95 % CI 2.4-7.4) were predictors of life-threatening events. Using this model, standardized life-threatening event ratios were calculated, thus showing that one institution had a life-threatening event rate greater than expected. Congenital cardiac catheterization and intervention can be performed safely with a low rate of life-threatening events and mortality; preprocedural evaluation of risk may optimize preparation of emergency rescue and bailout procedures. Risk predictors (age < 1, hemodynamic vulnerability, and procedure risk category) can enhance preprocedural patient risk stratification and planning.


Assuntos
Cateterismo Cardíaco , Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas , Complicações Intraoperatórias , Gestão da Segurança/organização & administração , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/estatística & dados numéricos , Criança , Pré-Escolar , Cuidados Críticos/métodos , Cuidados Críticos/normas , Estado Terminal/epidemiologia , Estado Terminal/terapia , Gerenciamento Clínico , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Cardiopatias Congênitas/classificação , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Incidência , Lactente , Recém-Nascido , Complicações Intraoperatórias/classificação , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/terapia , Masculino , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Melhoria de Qualidade , Risco Ajustado/métodos , Fatores de Risco , Índice de Gravidade de Doença , Estados Unidos/epidemiologia
6.
Neurosurgery ; 70(1 Suppl Operative): 65-73; discussion 73-4, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21811190

RESUMO

BACKGROUND: Intraoperative measurements of cerebral blood flow are of interest during vascular neurosurgery. Near-infrared indocyanine green (ICG) fluorescence angiography was introduced for visualizing vessel patency intraoperatively. However, quantitative information has not been available. OBJECTIVE: To report our experience with a microscope with an integrated dynamic ICG fluorescence analysis system supplying semiquantitative information on blood flow. METHODS: We recorded ICG fluorescence curves of cortex and cerebral vessels using software integrated into the surgical microscope (Flow 800 software; Zeiss Pentero) in 30 patients undergoing surgery for different pathologies. The following hemodynamic parameters were assessed: maximum intensity, rise time, time to peak, time to half-maximal fluorescence, cerebral blood flow index, and transit times from arteries to cortex. RESULTS: For patients without obvious perfusion deficit, maximum fluorescence intensity was 177.7 arbitrary intensity units (AIs; 5-mg ICG bolus), mean rise time was 5.2 seconds (range, 2.9-8.2 seconds; SD, 1.3 seconds), mean time to peak was 9.4 seconds (range, 4.9-15.2 seconds; SD, 2.5 seconds), mean cerebral blood flow index was 38.6 AI/s (range, 13.5-180.6 AI/s; SD, 36.9 seconds), and mean transit time was 1.5 seconds (range, 360 milliseconds-3 seconds; SD, 0.73 seconds). For 3 patients with impaired cerebral perfusion, time to peak, rise time, and transit time between arteries and cortex were markedly prolonged (>20, >9 , and >5 seconds). In single patients, the degree of perfusion impairment could be quantified by the cerebral blood flow index ratios between normal and ischemic tissue. Transit times also reflected blood flow perturbations in arteriovenous fistulas. CONCLUSION: Quantification of ICG-based fluorescence angiography appears to be useful for intraoperative monitoring of arterial patency and regional cerebral blood flow.


Assuntos
Isquemia Encefálica/diagnóstico , Circulação Cerebrovascular/fisiologia , Angiofluoresceinografia/métodos , Verde de Indocianina , Microscopia de Fluorescência/métodos , Cirurgia Assistida por Computador/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Idoso , Isquemia Encefálica/fisiopatologia , Artérias Cerebrais/fisiopatologia , Artérias Cerebrais/cirurgia , Corantes , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Chirurg ; 81(7): 612-9, 2010 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-20517586

RESUMO

Intraoperative neuromonitoring (IONM) was introduced into thyroid surgery approximately 10 years ago for better identification of recurrent laryngeal nerve palsy. Since then several studies have been performed for evaluation of this new technology. IONM is superior to visual nerve identification alone for prediction of postoperative local cord function. Therefore, in bilateral procedures IONM enables intraoperative decision-making concerning resection of the second side. To avoid misinterpretation of the results of IONM a standardized approach including preoperative and postoperative laryngoscopy and preresection and postresection vagus stimulation is recommended. Trouble-shooting requires systematic checking of the device including control of electrode position (needle or tube electrodes). For expert assessment purposes documentation of the standardized application of IONM is of utmost importance.


Assuntos
Eletromiografia , Prova Pericial/legislação & jurisprudência , Complicações Intraoperatórias/diagnóstico , Imperícia/legislação & jurisprudência , Monitorização Intraoperatória , Estimulação do Nervo Vago , Paralisia das Pregas Vocais/diagnóstico , Alemanha , Humanos , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Laringoscopia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/prevenção & controle , Nervo Laríngeo Recorrente/fisiopatologia , Traumatismos do Nervo Laríngeo Recorrente , Nervo Vago/fisiopatologia , Paralisia das Pregas Vocais/fisiopatologia , Paralisia das Pregas Vocais/prevenção & controle
8.
Neurosurgery ; 67(1): 166-71; discussion 171-2, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20568670

RESUMO

BACKGROUND: Heat transfer from bipolar tips to adjacent tissue presents a risk of thermal injury during spine surgery. OBJECTIVE: The present study was designed to determine wither bipolar forceps using a novel heat pipe thermal regulation technology resulted in decreased collateral thermal injury of adjacent tissue compared with traditional bipolar forceps (control). METHODS: Eight sheep underwent multilevel laminectomy and controlled bipolar coagulation of the dorsal spinal dura mater at multiple levels using forceps with or without heat pipe technology (24 spinal segments tested; heat pipe, n=11; non-heat pipe, n=11; sham, n=2). The severity (range, 1-5) and size of thermal injury to the spinal cord resulting from forceps with vs without heat pipe were assessed via histological analysis at 8 days postoperatively. RESULTS: Macroscopic occlusion of the pial vein underlying the segment of epidural coagulation occurred at surgery in 64% of segments (7 of 11) coagulated with control forceps but did not occur in any segments coagulated with heat pipe forceps (P<.005). The mean width (0.58+/-0.58 vs 1.4+/-0.77 mm; P<.05) and cross-sectional area of unintended thermal injury (1.2+/-1.7 vs 4.9+/-3.2 mm2; P<.05) were decreased in segments treated with heat pipe forceps compared with control. The severity of thermal injury was decreased in segments coagulated with (median, grade 1) vs without (median, grade 3) heat pipe forceps (P<.05). CONCLUSION: Bipolar forceps that incorporate heat pipe technology limited thermal spread and reduced the extent of unintended injury to the spinal cord and collateral vessels.


Assuntos
Queimaduras/prevenção & controle , Eletrocoagulação/instrumentação , Temperatura Alta/efeitos adversos , Microcirurgia/instrumentação , Procedimentos Neurocirúrgicos/instrumentação , Instrumentos Cirúrgicos/normas , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Queimaduras/etiologia , Queimaduras/fisiopatologia , Modelos Animais de Doenças , Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Feminino , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Microcirurgia/efeitos adversos , Microcirurgia/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/métodos , Carneiro Doméstico , Instrumentos Cirúrgicos/efeitos adversos , Instrumentos Cirúrgicos/tendências , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/métodos
9.
Spine (Phila Pa 1976) ; 35(9 Suppl): S37-46, 2010 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-20407350

RESUMO

OBJECTIVE: The objective of this article was to undertake a systematic review of the literature to determine whether IOM is able to sensitively and specifically detect intraoperative neurologic injury during spine surgery and to assess whether IOM results in improved outcomes for patients during these procedures. SUMMARY AND BACKGROUND DATA: Although relatively uncommon, perioperative neurologic injury, in particular spinal cord injury, is one of the most feared complications of spinal surgery. Intraoperative neuromonitoring (IOM) has been proposed as a method which could reduce perioperative neurologic complications after spine surgery. METHODS: A systematic review of the English language literature was undertaken for articles published between 1990 and March 2009. MEDLINE, EMBASE, and Cochrane Collaborative Library databases were searched, as were the reference lists of published articles examining the use of IOM in spine surgery. Two independent reviewers assessed the level of evidence quality using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria, and disagreements were resolved by consensus. RESULTS: A total of 103 articles were initially screened and 32 ultimately met the predetermined inclusion criteria. We determined that there is a high level of evidence that multimodal IOM is sensitive and specific for detecting intraoperative neurologic injury during spine surgery. There is a low level of evidence that IOM reduces the rate of new or worsened perioperative neurologic deficits. There is very low evidence that an intraoperative response to a neuromonitoring alert reduces the rate of perioperative neurologic deterioration. CONCLUSION: Based on strong evidence that multimodality intraoperative neuromonitoring (MIOM) is sensitive and specific for detecting intraoperative neurologic injury during spine surgery, it is recommended that the use of MIOM be considered in spine surgery where the spinal cord or nerve roots are deemed to be at risk, including procedures involving deformity correction and procedures that require the placement of instrumentation. There is a need to develop evidence-based protocols to deal with intraoperative changes in MIOM and to validate these prospectively.


Assuntos
Complicações Intraoperatórias/prevenção & controle , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Traumatismos da Medula Espinal/prevenção & controle , Doenças da Coluna Vertebral/cirurgia , Eletrodiagnóstico/métodos , Eletrodiagnóstico/normas , Medicina Baseada em Evidências , Humanos , Doença Iatrogênica/prevenção & controle , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Erros Médicos/prevenção & controle , Monitorização Intraoperatória/normas , Procedimentos Neurocirúrgicos/métodos , Gestão de Riscos/métodos , Gestão de Riscos/normas , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/fisiopatologia
11.
J Clin Neurosci ; 17(1): 26-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19910198

RESUMO

We performed a prospective study to evaluate the intraoperative value of indocyanine green (ICG) video angiography in anterior circulation aneurysms. From January 2007 to April 2008, 42 patients with anterior circulation aneurysms who were to undergo aneurysm clipping were enrolled in the study. Intraoperative ICG video angiography was performed using a fluorescence microscope. After the operation, three-dimensional CT angiography (CTA), digital substraction angiography (DSA) and magnetic resonance angiography (MRA) were used to evaluate the use of intraoperative ICG video angiography. Of the 42 patients, on ICG video angiography after initial clip placement, neck remnants of the aneurysm were found in two patients, inadvertent clipping of branching vessels in one patient, and inadvertent clipping of perforating vessels in two patients. ICG video angiography after adjustment of the clip position showed a perfect residual elimination with no abnormal findings. Post-operative DSA, CTA and MRA results corresponded to the intraoperative ICG video angiography findings. Therefore, ICG video angiography is an important tool to monitor residual aneurysm, parent artery stenosis or perforating artery occlusion during intracranial aneurysm clipping.


Assuntos
Artéria Cerebral Anterior/diagnóstico por imagem , Angiografia Cerebral/métodos , Verde de Indocianina , Aneurisma Intracraniano/diagnóstico por imagem , Artéria Cerebral Média/diagnóstico por imagem , Gravação em Vídeo/métodos , Adulto , Idoso , Artéria Cerebral Anterior/patologia , Artéria Cerebral Anterior/cirurgia , Corantes/efeitos adversos , Exantema/induzido quimicamente , Feminino , Humanos , Verde de Indocianina/efeitos adversos , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/cirurgia , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Microscopia/métodos , Pessoa de Meia-Idade , Artéria Cerebral Média/patologia , Artéria Cerebral Média/cirurgia , Monitorização Intraoperatória/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Valor Preditivo dos Testes , Estudos Prospectivos , Instrumentos Cirúrgicos , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos
12.
Eur Spine J ; 17(11): 1462-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18781342

RESUMO

This is an experimental study on human cadaver spines. The objective of this study is to compare the pullout forces between three screw augmentation methods and two different screw designs. Surgical interventions of patients with osteoporosis increase following the epidemiological development. Biomechanically the pedicle provides the strongest screw fixation in healthy bone, whereas in osteoporosis all areas of the vertebra are affected by the disease. This explains the high screw failure rates in those patients. Therefore PMMA augmentation of screws is often mandatory. This study involved investigation of the pullout forces of augmented transpedicular screws in five human lumbar spines (L1-L4). Each spine was treated with four different methods: non-augmented unperforated (solid) screw, perforated screw with vertebroplasty augmentation, solid screw with vertebroplasty augmentation and solid screw with balloon kyphoplasty augmentation. Screws were augmented with Polymethylmethacrylate (PMMA). The pullout forces were measured for each treatment with an Instron testing device. The bone mineral density was measured for each vertebra with Micro-CT. The statistical analysis was performed with a two-sided independent student t test. Forty screws (10 per group and level) were inserted. The vertebroplasty-augmented screws showed a significant higher pullout force (mean 918.5 N, P = 0.001) than control (mean 51 N), the balloon kyphoplasty group did not improve the pullout force significantly (mean 781 N, P > 0.05). However, leakage occurred in some cases treated with perforated screws. All spines showed osteoporosis on Micro-CT. Vertebroplasty-augmented screws, augmentation of perforated screws and balloon kyphoplasty augmented screws show higher pullout resistance than non-augmented screws. Significant higher pullout forces were only reached in the vertebroplasty augmented vertebra. The perforated screw design led to epidural leakage due to the position of the perforation in the screw. The position of the most proximal perforation is critical, depending on screw design and proper insertion depth. Nevertheless, using a properly designed perforated screw will facilitate augmentation and instrumentation in osteoporotic spines.


Assuntos
Parafusos Ósseos/normas , Osteoporose/patologia , Osteoporose/cirurgia , Fusão Vertebral/instrumentação , Coluna Vertebral/patologia , Coluna Vertebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos/uso terapêutico , Densidade Óssea/fisiologia , Parafusos Ósseos/efeitos adversos , Falha de Equipamento , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Complicações Intraoperatórias/prevenção & controle , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Vértebras Lombares/cirurgia , Masculino , Osteoporose/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Radiografia , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/prevenção & controle , Fusão Vertebral/métodos , Coluna Vertebral/diagnóstico por imagem , Estresse Mecânico , Vertebroplastia/instrumentação , Vertebroplastia/métodos , Suporte de Carga/fisiologia
13.
World J Gastroenterol ; 13(38): 5090-5, 2007 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-17876874

RESUMO

AIM: To establish a scoring system for predicting the incidence of postoperative complications and mortality in general surgery based on the physiological and operative severity score for the enumeration of mortality and morbidity (POSSUM), and to evaluate its efficacy. METHODS: Eighty-four patients with postoperative complications or death and 172 patients without postoperative complications, who underwent surgery in our department during the previous 2 years, were retrospectively analyzed by logistic regression. Fifteen indexes were investigated including age, cardiovascular function, respiratory function, blood test results, endocrine function, central nervous system function, hepatic function, renal function, nutritional status, extent of operative trauma, and course of anesthesia. Modified POSSUM (M-POSSUM) was developed using significant risk factors with its efficacy evaluated. RESULTS: The significant risk factors were found to be age, cardiovascular function, respiratory function, hepatic function, renal function, blood test results, endocrine function, nutritional status, duration of operation, intraoperative blood loss, and course of anesthesia. These factors were all included in the scoring system. There were significant differences in the scores between the patients with and without postoperative complications, between the patients died and survived with complications, and between the patients died and survived without complications. The receiver operating characteristic curves showed that the M-POSSUM could accurately predict postoperative complications and mortality. CONCLUSION: M-POSSUM correlates well with postoperative complications and mortality, and is more accurate than POSSUM.


Assuntos
Indicadores Básicos de Saúde , Complicações Intraoperatórias/mortalidade , Complicações Pós-Operatórias/mortalidade , Medição de Risco/métodos , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Modelos Logísticos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes , Fatores de Risco
14.
Anaesthesist ; 56(3): 285-96; quiz 297-8, 2007 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-17342546

RESUMO

Myocardial ischemia is a major cause of perioperative morbidity and mortality. Because of a growing expectancy of lives, the prevalence of cardiovascular diseases is increasing, and thus the number of surgical patients presenting with a cardiovascular risk profile. Based upon pathophysiological considerations, different interventions to lower perioperative cardiovascular risk have been evaluated. The mostly discussed intervention believed to prevent cardiovascular complications in the perioperative period is the use of beta-blockers. Although many authors agree that perioperative beta-blockade is effective in high-risk patients, less is known about the optimal timing, dosage and the identification of patients in whom the intervention would be beneficial. Based upon the available data we try to answer questions about timing and dosage, and we discuss possible side effects and economic questions. Another cardioprotective option is the use of statins. Besides their lipid-lowering properties, so called pleiotropic effects are believed to decrease cardiac risk. Furthermore, different interventions can be used in addition to or as an alternative to perioperative beta-blocker therapy, such as alpha-2 agonists, thoracic epidural analgesia or coronary revascularization.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Cardiotônicos/uso terapêutico , Complicações Intraoperatórias/prevenção & controle , Isquemia Miocárdica/prevenção & controle , Assistência Perioperatória/normas , Agonistas alfa-Adrenérgicos/uso terapêutico , Antagonistas Adrenérgicos beta/efeitos adversos , Antagonistas Adrenérgicos beta/economia , Analgesia Epidural , Cardiotônicos/efeitos adversos , Cardiotônicos/economia , Ensaios Clínicos como Assunto , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/economia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Complicações Intraoperatórias/fisiopatologia , Lipídeos/sangue , Isquemia Miocárdica/fisiopatologia , Revascularização Miocárdica , Risco
15.
Brain Res ; 1118(1): 183-91, 2006 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-16996490

RESUMO

BACKGROUND: An important part of the medical treatment of many cerebrovascular diseases is the occlusion of brain supplying arteries. Until now, the risk of this intervention can only be estimated by invasive diagnostics including the risk of cerebrovascular accidents. METHODS AND RESULTS: As a supporting tool, a computer model of the circle of Willis was designed. The model is based upon linear differential equations describing electrotechnical circuits extended non-linearly. By these means, time continuous simulations of different states and the online observation of all calculated state variables such as blood pressure and blood flow in every modeled vessel became feasible. For individual simulations, model parameters were determined by MR-angiography and boundary values by simultaneous Duplex-measurements in both carotid and vertebral arteries. State variables generated by the model behaved physiologically and the reaction of individual cerebrovascular systems in critical situations could be investigated by special scenarios. Inaccuracies concerning the determination of model parameters and boundary values of the used differential equations are likely to be resolved in the near future through a more careful and technically improved determination of these values. CONCLUSIONS: Computer models of subjects were created taking in account the individual anatomical and non-linear physical properties of real vascular systems supplying the brain. Thereby information could be obtained concerning the hemodynamic effects of an iatrogenic vascular occlusion.


Assuntos
Circulação Cerebrovascular/fisiologia , Círculo Arterial do Cérebro/fisiologia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Complicações Intraoperatórias/prevenção & controle , Cuidados Pré-Operatórios/métodos , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Artérias Cerebrais/fisiologia , Artérias Cerebrais/cirurgia , Transtornos Cerebrovasculares/fisiopatologia , Transtornos Cerebrovasculares/cirurgia , Círculo Arterial do Cérebro/anatomia & histologia , Círculo Arterial do Cérebro/diagnóstico por imagem , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Angiografia por Ressonância Magnética , Modelos Biológicos , Dinâmica não Linear , Medição de Risco/métodos , Ultrassonografia Doppler Dupla , Artéria Vertebral/anatomia & histologia , Artéria Vertebral/fisiologia , Artéria Vertebral/cirurgia
17.
Ann Thorac Surg ; 74(5): S1864-6; discussion S1892-8, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12440681

RESUMO

BACKGROUND: Monitoring motor-evoked potentials (MEPs) is an accurate technique to assess spinal cord integrity during thoracoabdominal aortic aneurysm (TAAA) repair, guiding surgical strategies to prevent paraplegia. METHODS: In 210 consecutive patients with type I (n = 75), type II (n = 103), and type III (n = 32) TAAA surgical repair was performed using left heart bypass, cerebrospinal fluid drainage, and MEPs monitoring. RESULTS: Reliable MEPs were registered in all patients. The median total number of patent intercostal and lumbar arteries was five. After proximal aortic crossclamping, MEP decreased below 25% of base line in 72 patients (34%) indicating critical spinal cord ischemia, which could be corrected by increasing distal aortic pressure. By using sequential clamping it appeared that in 43% of type I and II cases spinal cord circulation was supplied between T5 and L1, and 57% between L1 and L5. In type II and III cases cord perfusion was dependent upon lower lumbar arteries in 16% and pelvic circulation in 8%, necessitating reattachment of these segmental arteries. In 9% of patients critical ischemic MEP changes occurred without visible arteries, requiring aortic endarterectomy and selective grafting. One patient suffered early paraplegia and 2 delayed, and 2 patients had temporary neurologic deficit (5 of 210; 2.4%). CONCLUSIONS: In patients with TAAA, blood supply to the spinal cord depends upon a highly variable collateral system. Monitoring MEPs is an accurate technique for detecting cord ischemia, guiding surgical tactics to reduce neurologic deficit (2.4%).


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Complicações Intraoperatórias/prevenção & controle , Monitorização Intraoperatória , Isquemia do Cordão Espinal/prevenção & controle , Adulto , Idoso , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/mortalidade , Circulação Colateral/fisiologia , Potencial Evocado Motor/fisiologia , Feminino , Mortalidade Hospitalar , Humanos , Complicações Intraoperatórias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Prognóstico , Reprodutibilidade dos Testes , Isquemia do Cordão Espinal/fisiopatologia
18.
Anesthesiol Clin North Am ; 20(3): 513-37, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12298304

RESUMO

Adverse pulmonary outcomes that follow anesthesia and surgery are often attributed to anesthesia care. PPCs are a significant concern for anesthesia caregivers because they use drugs and techniques that temporarily decrease lung volume, impair airway reflexes, limit immune function, and depress secretion mobilization. A significant component of perioperative risk derives from the surgical site, postoperative pain, and effects of pharmacologic pain management. Rapidly evolving surgical and anesthesia techniques and the introduction of newer pharmaceutical agents make it difficult to identify best practice from retrospective experience reported in the perioperative literature. Prospective studies that deal with specific patient populations, incomparable patient groups or techniques, and unique practice bias have limited validity of claims regarding several promising approaches to perioperative risk reduction. In the absence of clear scientific principles, a perioperative pulmonary risk management strategy for the early part of this century is based on the consensus practice of informed clinicians (Box 4).


Assuntos
Anestesia/efeitos adversos , Sistema Respiratório/lesões , Doenças Respiratórias/induzido quimicamente , Anestesia por Condução/efeitos adversos , Anestésicos/efeitos adversos , Humanos , Hipóxia/epidemiologia , Hipóxia/etiologia , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/fisiopatologia , Pneumonia Aspirativa/epidemiologia , Pneumonia Aspirativa/etiologia , Doenças Respiratórias/epidemiologia , Fatores de Risco , Gestão de Riscos
19.
J Intern Med ; 252(1): 11-20, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12074733

RESUMO

Despite the number of technologies used, the diagnosis of perioperative myocardial infarction is still a challenge. Studies conducted in surgical series have demonstrated that cardiac troponins (cTns) have both a superior diagnostic sensitivity and specificity, compared with other traditional techniques, and an independent power to predict short- and long-term prognosis. Nevertheless, some points need to be clarified. They include the usefulness of cTns in patients with end-stage renal failure; the standardization of the cTns cut-off for the diagnosis of myocardial injury; the timing of postoperative blood samplings; the cost-effectiveness of a screening in asymptomatic patients; and the possible therapeutic strategies.


Assuntos
Complicações Intraoperatórias , Infarto do Miocárdio/diagnóstico , Troponina/sangue , Análise Custo-Benefício , Diagnóstico Diferencial , Humanos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/tratamento farmacológico , Complicações Intraoperatórias/fisiopatologia , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/fisiopatologia , Prognóstico , Fatores de Risco , Sensibilidade e Especificidade
20.
Anaesthesia ; 56(11): 1051-8, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11703237

RESUMO

Incidence rates of electrocardiographic changes during Caesarean section vary from 25 to 60%. To date, no investigator has identified myocardial ischaemia resulting from these changes. We investigated patients undergoing elective Caesarean section using peripartum Holter monitoring and serum analysis of cardiac troponin I (cTnI). Twenty-six patients presenting for elective Caesarean section were studied. Peroperative Holter monitoring continued for 12 h postoperatively, at which time blood samples for cTnI levels were taken. Significant ST changes were recorded in 42% of patients peroperatively and 38.5% of patients postoperatively. Forty-two per cent of patients experienced peroperative chest pain requiring opioid analgesia. Chest pain was significantly associated with abnormal electrocardiogram (ECG) findings. Ischaemic levels of cTnI were recorded in two patients. This study reports, for the first time, myocardial ischaemia (7.69% of patients) arising in conjunction with the ECG changes seen during elective Caesarean section. We also report episodes of significant postoperative ST-segment changes.


Assuntos
Cesárea/efeitos adversos , Isquemia Miocárdica/etiologia , Complicações Cardiovasculares na Gravidez/etiologia , Adulto , Biomarcadores/sangue , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca , Humanos , Complicações Intraoperatórias/sangue , Complicações Intraoperatórias/fisiopatologia , Isquemia Miocárdica/sangue , Isquemia Miocárdica/fisiopatologia , Assistência Perioperatória , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/fisiopatologia , Gravidez , Complicações Cardiovasculares na Gravidez/sangue , Complicações Cardiovasculares na Gravidez/fisiopatologia , Troponina I/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA