Sci Rep ; 10(1): 21216, 2020 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-33277561

RESUMO

User-friendly phenotypic antibiotic susceptibility testing (AST) methods are urgently needed in many fields including clinical medicine, epidemiological studies and drug research. Herein, we report a convenient and cost-effective phenotypic AST method based on online monitoring bacterial growth with a developed 8-channel contactless conductometric sensor (CCS). Using E. coli and V. parahaemolyticus as microorganism models, as well as enoxacin, florfenicol, ampicillin, kanamycin and sulfadiazine as antibiotic probes. The minimum inhibitory concentration (MIC) determination was validated in comparison with standard broth microdilution (BMD) assay. The total essential agreements between the CCS AST assays and the reference BMD AST assays are 68.8-92.3%. The CCS has an approximate price of $9,000 (USD). Requiring neither chemical nor biotic auxiliary materials for the assay makes the cost of each sample < $1. The MICs obtained with the automated CCS AST assays are more precise than those obtained with the manual BMD. Moreover, in 72 percent of the counterpart, the MICs obtained with the CCS AST assays are higher than that obtained with the BMD AST assays. The proposed CCS AST method has advantages in affordability, accuracy, sensitivity and user-friendliness.


Assuntos
Antibacterianos/farmacologia , Condutometria/instrumentação , Condutometria/métodos , Escherichia coli/efeitos dos fármacos , Vibrio parahaemolyticus/efeitos dos fármacos , Ampicilina/farmacologia , Custos e Análise de Custo , Enoxacino/farmacologia , Canamicina/farmacologia , Testes de Sensibilidade Microbiana , Sulfadiazina/farmacologia , Tianfenicol/análogos & derivados , Tianfenicol/farmacologia
2.
Trends Biotechnol ; 35(1): 33-42, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27612567

RESUMO

Biomimetic crossreactive sensor arrays have been used to detect and analyze a wide variety of vapor and liquid components in applications such as food science, public health and safety, and diagnostics. As technology has advanced over the past three decades, these systems have become selective, sensitive, and affordable. Currently, the need for noninvasive and accurate devices for early disease diagnosis remains a challenge. This Opinion article provides an overview of the various types of biomimetic crossreactive sensor arrays (also referred to as electronic noses or tongues in the literature), their current use and future directions, and an outlook for future technological development.


Assuntos
Materiais Biomiméticos , Técnicas Biossensoriais/instrumentação , Testes Respiratórios/instrumentação , Diagnóstico por Computador/instrumentação , Nariz Eletrônico , Gases/análise , Testes Respiratórios/métodos , Condutometria/instrumentação , Diagnóstico por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Sistemas Microeletromecânicos/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito
3.
IEEE Trans Biomed Circuits Syst ; 10(5): 945-954, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-28113176

RESUMO

This paper describes the design and characterization of a reconfigurable, multi-technique electrochemical biosensor designed for direct integration into smartphone and wearable technologies to enable remote and accurate personal health monitoring. By repurposing components from one mode to the next, the biosensor's potentiostat is able reconfigure itself into three different measurements modes to perform amperometric, potentiometric, and impedance spectroscopic tests all with minimal redundant devices. A [Formula: see text] PCB prototype of the module was developed with discrete components and tested using Google's Project Ara modular smartphone. The amperometric mode has a ±1 nA to [Formula: see text] measurement range. When used to detect pH, the potentiometric mode achieves a resolution of < 0.08 pH units. In impedance measurement mode, the device can measure 50 Ω-10 [Formula: see text] and has been shown to have of phase error. This prototype was used to perform several point-of-care health tracking assays suitable for use with mobile devices: 1) Blood glucose tests were conducted and shown to cover the diagnostic range for Diabetic patients (  âˆ¼  200 mg/dL). 2) Lactoferrin, a biomarker for urinary tract infections, was detected with a limit of detection of approximately 1 ng/mL. 3) pH tests of sweat were conducted to track dehydration during exercise. 4) EIS was used to determine the concentration of NeutrAvidin via a label-free assay.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Diagnóstico por Computador/instrumentação , Autocuidado/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Smartphone , Telemedicina/instrumentação , Amplificadores Eletrônicos , Desenho de Equipamento , Análise de Falha de Equipamento , Monitorização Ambulatorial/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
4.
Biosens Bioelectron ; 74: 731-43, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26210471

RESUMO

Recently, as metal-, polymer-, and carbon-based biocompatible nanomaterials have been increasingly incorporated into biosensing applications, with various nanostructures having been used to increase the efficacy and sensitivity of most of the detecting devices, including field effect transistor (FET)-based devices. These nanomaterial-based methods also became the ideal for the amalgamation of biomolecules, especially for the fabrication of ultrasensitive, low-cost, and robust FET-based biosensors; these are categorically very successful at binding the target specified entities in the confined gated micro-region for high functionality. Furthermore, the contemplation of nanomaterial-based FET biosensors to various applications encompasses the desire for detection of many targets with high selectivity, and specificity. We assess how such devices have empowered the achievement of elevated biosensor performance in terms of high sensitivity, selectivity and low detection limits. We review the recent literature here to illustrate the diversity of FET-based biosensors, based on various kinds of nanomaterials in different applications and sum up that graphene or its assisted composite based FET devices are comparatively more efficient and sensitive with highest signal to noise ratio. Lastly, the future prospects and limitations of the field are also discussed.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Microeletrodos/tendências , Nanopartículas/química , Nanotecnologia/instrumentação , Transistores Eletrônicos/tendências , Técnicas Biossensoriais/tendências , Condutometria/tendências , Condutividade Elétrica , Desenho de Equipamento , Nanopartículas/ultraestrutura , Nanotecnologia/tendências , Avaliação da Tecnologia Biomédica
5.
Bioprocess Biosyst Eng ; 38(9): 1671-83, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25980384

RESUMO

The present study summarizes the designing of a green transducer phase based on nano-cerium oxide (CeO2) decorated reduced graphene oxide (RGO) reinforced chitosan nanocomposites as an effective enzyme immobilizer and bio-sensing matrix for glucose analyte. Also, it scrutinizes the biocompatibility and cell viability of the synthesized nanohybrid with human fibroblastic macrophage cell line. CeO2 nanoparticles (NPs) were successfully grown on graphene nanosheet in the presence of cationic surfactant followed by facile hydrothermal treatment. The eventual growth of synthesized CeO2 nanocrystals on the graphene layer was confirmed from X-ray diffraction (XRD), transmission electron microscopy (TEM) and Raman analysis. The biocompatibility of the synthesized nanohybrid was also evident from the MTT assay. Glucose oxidase (GOx) was employed on the green polymer nanocomposites modified FTO electrode to fabricate an enzymatic bioelectrode. The electroanalytical response of the GOx/nano-CeO2/RGO/CS/FTO bioelectrode towards electrooxidation of glucose analyte was investigated by electrochemical impedance (EIS) and cyclic voltammetry (CV) study. The resulting biosensor exhibited a good electrochemical response to glucose within the linear detection range of 0.05-6.5 mM with a low detection limit of 2 µM and a sensitivity of 7.198 µA mM(-1) cm(-2). The bioelectrode also showed good shelf life (~10 weeks) and negligible interfering ability under controlled environment. The obtained results indicate that nano-CeO2/RGO nanohybrid based chitosan nanocomposites achieve a biocompatible biosensing platform for effective enzyme immobilization due to the excellent synergistic effects between the CeO2 nanoparticles and graphene sheet.


Assuntos
Técnicas Biossensoriais/instrumentação , Cério/química , Glucose Oxidase/química , Glucose/análise , Grafite/química , Nanopartículas Metálicas/química , Materiais Biocompatíveis/síntese química , Materiais Biocompatíveis/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Cério/administração & dosagem , Quitosana/química , Quitosana/farmacologia , Condutometria/instrumentação , Eletrodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Glucose/química , Química Verde/métodos , Humanos , Macrófagos/efeitos dos fármacos , Macrófagos/fisiologia , Nanopartículas Metálicas/administração & dosagem , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/administração & dosagem , Nanocompostos/química , Nanocompostos/ultraestrutura , Tamanho da Partícula
6.
Biosens Bioelectron ; 69: 328-36, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25791338

RESUMO

In this work we report on the production of a low cost microfluidic device for the multiplexed electrochemical detection of magneto bioassays. As a proof of concept, the device has been used to detect myeloperoxidase (MPO), a cardiovascular biomarker. With this purpose, two bioassays have been optimized in parallel onto magnetic beads (MBs) for the simultaneous detection of MPO endogenous peroxidase activity and quantification of total MPO. Since the two bioassays produced signals of different magnitude for each concentration of MPO tested, two detection strategies have been compared, which entailed registering steady state currents (Iss) under substrate flow, and measuring the peak currents (Ip) produced in a stopped flow approach. As it will be shown, appropriate tuning of the detection and flow conditions can provide extremely sensitive detection, but also allow simultaneous detection of assays or parameters that would produce signals of different orders of magnitude when measured by a single detection strategy. In order to demonstrate the feasibility of the detection strategy reported, a dual MPO mass and activity assay has been finally applied to the study of 10 real plasma samples, allowing patient classification according to the risk of suffering a cardiovascular event.


Assuntos
Bioensaio/instrumentação , Condutometria/instrumentação , Doença da Artéria Coronariana/sangue , Separação Imunomagnética/instrumentação , Microfluídica/instrumentação , Peroxidase/sangue , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Small ; 11(27): 3351-6, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25760306

RESUMO

Pressure sensors based on solution-processed metal-organic frameworks nanowire arrays are fabricated with very low cost, flexibility, high sensitivity, and ease of integration into sensor arrays. Furthermore, the pressure sensors are suitable for monitoring and diagnosing biomedical signals such as radial artery pressure waveforms in real time.


Assuntos
Vestuário , Condutometria/instrumentação , Nanopartículas Metálicas/química , Monitorização Ambulatorial/instrumentação , Nanocompostos/química , Transdutores de Pressão , Materiais Biomiméticos , Cristalização/métodos , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/ultraestrutura , Nanotecnologia/instrumentação , Sensibilidade e Especificidade , Integração de Sistemas
8.
ISA Trans ; 56: 268-75, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25532935

RESUMO

In this paper, the design of a complete instrumentation system to detect different types of milk adulteration has been reported. A simple to use indicator type readout device is reported which can be used by milk community people. A low cost microcontroller based automatic sensing system is also reported to detect 'synthetic milk', which has been reconstructed after adulterating the milk with 'liquid-whey'.


Assuntos
Condutometria/instrumentação , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Leite/química , Ureia/análise , Água/análise , Animais , Condutometria/economia , Análise Custo-Benefício , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Alimentos/economia , Contaminação de Alimentos/economia , Índia , Leite/economia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Sensors (Basel) ; 14(7): 12233-55, 2014 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-25010697

RESUMO

Herbal-based products are becoming a widespread production trend among manufacturers for the domestic and international markets. As the production increases to meet the market demand, it is very crucial for the manufacturer to ensure that their products have met specific criteria and fulfil the intended quality determined by the quality controller. One famous herbal-based product is herbal tea. This paper investigates bio-inspired flavour assessments in a data fusion framework involving an e-nose and e-tongue. The objectives are to attain good classification of different types and brands of herbal tea, classification of different flavour masking effects and finally classification of different concentrations of herbal tea. Two data fusion levels were employed in this research, low level data fusion and intermediate level data fusion. Four classification approaches; LDA, SVM, KNN and PNN were examined in search of the best classifier to achieve the research objectives. In order to evaluate the classifiers' performance, an error estimator based on k-fold cross validation and leave-one-out were applied. Classification based on GC-MS TIC data was also included as a comparison to the classification performance using fusion approaches. Generally, KNN outperformed the other classification techniques for the three flavour assessments in the low level data fusion and intermediate level data fusion. However, the classification results based on GC-MS TIC data are varied.


Assuntos
Bebidas/análise , Biomimética/instrumentação , Condutometria/instrumentação , Análise de Alimentos/instrumentação , Nariz/fisiologia , Paladar/fisiologia , Língua/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Sensors (Basel) ; 14(5): 7881-939, 2014 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-24784036

RESUMO

Humidity measurement is one of the most significant issues in various areas of applications such as instrumentation, automated systems, agriculture, climatology and GIS. Numerous sorts of humidity sensors fabricated and developed for industrial and laboratory applications are reviewed and presented in this article. The survey frequently concentrates on the RH sensors based upon their organic and inorganic functional materials, e.g., porous ceramics (semiconductors), polymers, ceramic/polymer and electrolytes, as well as conduction mechanism and fabrication technologies. A significant aim of this review is to provide a distinct categorization pursuant to state of the art humidity sensor types, principles of work, sensing substances, transduction mechanisms, and production technologies. Furthermore, performance characteristics of the different humidity sensors such as electrical and statistical data will be detailed and gives an added value to the report. By comparison of overall prospects of the sensors it was revealed that there are still drawbacks as to efficiency of sensing elements and conduction values. The flexibility offered by thick film and thin film processes either in the preparation of materials or in the choice of shape and size of the sensor structure provides advantages over other technologies. These ceramic sensors show faster response than other types.


Assuntos
Condutometria/instrumentação , Espectroscopia Dielétrica/instrumentação , Umidade , Transdutores , Água/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Avaliação da Tecnologia Biomédica
11.
Sensors (Basel) ; 14(5): 8718-27, 2014 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-24841249

RESUMO

The cornea is a very particular tissue due to its transparency and its barrier function as it has to resist against the daily insults of the external environment. In addition, maintenance of this barrier function is of crucial importance to ensure a correct corneal homeostasis. Here, the corneal epithelial permeability has been assessed in vivo by means of non-invasive tetrapolar impedance measurements, taking advantage of the huge impact of the ion fluxes in the passive electrical properties of living tissues. This has been possible by using a flexible sensor based in SU-8 photoresist. In this work, a further analysis focused on the validation of the presented sensor is performed by monitoring the healing process of corneas that were previously wounded. The obtained impedance measurements have been compared with the damaged area observed in corneal fluorescein staining images. The successful results confirm the feasibility of this novel method, as it represents a more sensitive in vivo and non-invasive test to assess low alterations of the epithelial permeability. Then, it could be used as an excellent complement to the fluorescein staining image evaluation.


Assuntos
Condutometria/instrumentação , Técnicas de Diagnóstico Oftalmológico/instrumentação , Eletrodos , Epitélio Corneano/lesões , Epitélio Corneano/fisiopatologia , Pletismografia de Impedância/instrumentação , Animais , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Electrophoresis ; 35(11): 1660-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24285507

RESUMO

A method has been developed for the simultaneous determination of taurine and caffeine using a laboratory-made instrument enabling separation analysis in a short 10.5 cm capillary. The substances are detected using a contactless conductometry/ultraviolet (UV) photometry detector that enables recording both signals at one place in the capillary. The separation of caffeine and taurine was performed using the MEKC technique in a BGE with the composition 40 mM CHES, 15 mM NaOH, and 50 mM SDS, pH 9.36. Under these conditions, the migration time of caffeine is 43 s and of taurine 60 s; LOD for caffeine is 4 mg/L using photometric detection and LOD for taurine is 24 mg/L using contactless conductometric detection. The standard addition method was used for determination in Red Bull energy drink of caffeine 317 mg/L and taurine 3860 mg/L; the contents in Kamikaze drink were 468 mg/L caffeine and 4110 mg/L taurine. The determined values are in good agreement with the declared contents of these substances. RSD does not exceed 3%.


Assuntos
Cafeína/análise , Cromatografia Capilar Eletrocinética Micelar/instrumentação , Bebidas Energéticas/análise , Taurina/análise , Cromatografia Capilar Eletrocinética Micelar/economia , Condutometria/economia , Condutometria/instrumentação , Condutividade Elétrica , Desenho de Equipamento , Limite de Detecção , Fotometria/economia , Fotometria/instrumentação
13.
Sensors (Basel) ; 13(10): 13584-95, 2013 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-24152922

RESUMO

In this paper we demonstrate the design of a low-cost optical current sensor. The sensor principle is the Faraday rotation of a light beam through a magneto-optical material, SF2, when a magnetic field is present. The prototype has a high sensitivity and a high linearity for currents ranging from 0 up to 800 A. The error of the optical fibre sensor is smaller than 1% for electric currents over 175 A.


Assuntos
Condutometria/instrumentação , Dispositivos Ópticos , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento
14.
Sensors (Basel) ; 13(8): 10659-73, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23955436

RESUMO

Metal oxide nanowires are very promising active materials for different applications, especially in the field of gas sensors. Advances in fabrication technologies now allow the preparation of nanowires on flexible substrates, expanding the potential market of the resulting sensors. The critical steps for the large-scale preparation of reliable sensing devices are the elimination of high temperatures processes and the stretchability of the entire final device, including the active material. Direct growth on flexible substrates and post-growth procedures have been successfully used for the preparation of gas sensors. The paper will summarize the procedures used for the preparation of flexible and wearable gas sensors prototypes with an overlook of the challenges and the future perspectives concerning this field.


Assuntos
Condutometria/instrumentação , Gases/análise , Nanopartículas Metálicas/química , Monitorização Ambulatorial/instrumentação , Nanotecnologia/instrumentação , Nanofios/química , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Óxidos/química , Avaliação da Tecnologia Biomédica
15.
Sensors (Basel) ; 13(7): 8997-9015, 2013 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-23857264

RESUMO

Advances in textile materials, technology and miniaturization of electronics for measurement instrumentation has boosted the development of wearable measurement systems. In several projects sensorized garments and non-invasive instrumentation have been integrated to assess on emotional, cognitive responses as well as physical arousal and status of mental stress through the study of the autonomous nervous system. Assessing the mental state of workers under stressful conditions is critical to identify which workers are in the proper state of mind and which are not ready to undertake a mission, which might consequently risk their own life and the lives of others. The project Assessment in Real Time of the Stress in Combatants (ATREC) aims to enable real time assessment of mental stress of the Spanish Armed Forces during military activities using a wearable measurement system containing sensorized garments and textile-enabled non-invasive instrumentation. This work describes the multiparametric sensorized garments and measurement instrumentation implemented in the first phase of the project required to evaluate physiological indicators and recording candidates that can be useful for detection of mental stress. For such purpose different sensorized garments have been constructed: a textrode chest-strap system with six repositionable textrodes, a sensorized glove and an upper-arm strap. The implemented textile-enabled instrumentation contains one skin galvanometer, two temperature sensors for skin and environmental temperature and an impedance pneumographer containing a 1-channel ECG amplifier to record cardiogenic biopotentials. With such combinations of garments and non-invasive measurement devices, a multiparametric wearable measurement system has been implemented able to record the following physiological parameters: heart and respiration rate, skin galvanic response, environmental and peripheral temperature. To ensure the proper functioning of the implemented garments and devices the full series of 12 sets have been functionally tested recording cardiogenic biopotential, thoracic impedance, galvanic skin response and temperature values. The experimental results indicate that the implemented wearable measurement systems operate according to the specifications and are ready to be used for mental stress experiments, which will be executed in the coming phases of the project with dozens of healthy volunteers.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Vestuário , Condutometria/instrumentação , Eletrocardiografia Ambulatorial/instrumentação , Resposta Galvânica da Pele/fisiologia , Tecnologia sem Fio/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Têxteis
16.
IEEE Trans Biomed Eng ; 60(10): 2848-57, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23739778

RESUMO

This paper presents a class of hydration monitor that uses ultrathin, stretchable sheets with arrays of embedded impedance sensors for precise measurement and spatially multiplexed mapping. The devices contain miniaturized capacitive electrodes arranged in a matrix format, capable of integration with skin in a conformal, intimate manner due to the overall skin-like physical properties. These "epidermal" systems noninvasively quantify regional variations in skin hydration, at uniform or variable skin depths. Experimental results demonstrate that the devices possess excellent uniformity, with favorable precision and accuracy. Theoretical models capture the underlying physics of the measurement and enable quantitative interpretation of the experimental results. These devices are appealing for applications ranging from skin care and dermatology, to cosmetology and health/wellness monitoring, with the additional potential for combined use with other classes of sensors for comprehensive, quantitative physiological assessment via the skin.


Assuntos
Água Corporal/metabolismo , Condutometria/instrumentação , Eletrodos , Epiderme/metabolismo , Membranas Artificiais , Absorção Cutânea/fisiologia , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espaço-Temporal
17.
Anal Bioanal Chem ; 405(14): 4975-9, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23443523

RESUMO

The application of cyclic biamperometry to viability and cytotoxicity assessments of human corneal epithelial cells has been investigated. Electrochemical measurements have been compared in PBS containing 5.0 mM glucose and minimal essential growth medium. Three different lipophilic mediators including dichlorophenol indophenol, 2-methyl-1,4-naphthoquinone (also called menadione or vitamin K3) and N,N,N',N'-tetramethyl-p-phenylenediamine have been evaluated for shuttling electrons across the cell membrane to the external medium. Transfer of these electrons to ferricyanide in the extra cellular medium results in the accumulation of ferrocyanide. The amount of ferrocyanide is then determined using cyclic biamperometry and is related to the extent of cell metabolic activity and therefore cell viability. To illustrate cytotoxicity assessment of chemicals, hydrogen peroxide, benzalkonium chloride and sodium dodecyl sulfate have been chosen as sample toxins, the cytotoxicities of which have been evaluated and compared to values reported in the literature. Similar values have been reported using colorimetric assays; however, the simplicity of this electrochemical assay can, in principle, open the way to miniaturization onto lab-on-chip devices and its incorporation into tiered-testing approaches for cytotoxicity assessment.


Assuntos
Bioensaio/instrumentação , Condutometria/instrumentação , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/fisiologia , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/fisiologia , Testes de Toxicidade/instrumentação , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/fisiologia , Células Cultivadas , Células Epiteliais/citologia , Epitélio Corneano/citologia , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Exp Clin Endocrinol Diabetes ; 121(2): 80-3, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23073917

RESUMO

INTRODUCTION: Sudomotor dysfunction is one of the earliest neurophysiologic abnormalities to manifest in distal small fiber neuropathy. SUDOSCAN® was developed to provide a non invasive, quick, simple and quantitative measurement of sweat function. The aim of this observational study was to assess sweat function in a diabetes outpatient consult clinic in Germany. METHODS: The study was conducted from February 2009 to March 2011 on patients of a diabetes outpatient clinic in Germany with type 1 and type 2 diabetes, and was conducted parallel to standard care. Sweat function was evaluated by measuring the electrochemical conductance (ESC) of the hands and feet. The method's reproducibility between 2 devices and a follow-up according to insulin administration were also assessed. RESULTS: 52 patients with type 1 diabetes and 115 patients with type 2 diabetes (69 receiving insulin) were involved in this observational study. Hand and foot conductances were lower in patients with type 2 diabetes when compared to patients with type 1 diabetes. A slight decrease in hand and foot conductances was observed in patients with type 2 diabetes without insulin, while an increase was observed in patients receiving insulin (-3.8±9.7 vs. 1.0±9.7 µS, p=0.02 for the hands and -2.2±7.5 vs. 4.1±8.8 µS, p<0.001 for the feet). Coefficient of correlation between measurements performed with the 2 different devices was 0.85 for hands and 0.93 for feet, p<0.001. No safety concern was reported and none of the subjects experienced discomfort during the tests. CONCLUSION: This preliminary study shows that the assessment of small C fiber neuropathy can be performed non invasively, quickly and effectively in standard diabetes outpatient practice with very good reproducibility. The observation that electrochemical skin conductance improves with intensified insulin treatment must be confirmed in a clinical study performed on a larger population.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Neuropatias Diabéticas/diagnóstico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Pele/efeitos dos fármacos , Glândulas Sudoríparas/efeitos dos fármacos , Adulto , Idoso , Condutometria/instrumentação , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Neuropatias Diabéticas/fisiopatologia , Neuropatias Diabéticas/prevenção & controle , Diagnóstico Precoce , Feminino , Seguimentos , , Resposta Galvânica da Pele/efeitos dos fármacos , Alemanha , Mãos , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Ambulatório Hospitalar , Glândulas Sudoríparas/fisiopatologia
19.
Biosens Bioelectron ; 31(1): 55-61, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22019100

RESUMO

The permeability of the cornea epithelial layer has an important role in optimal function of the cornea. To assess this property quantitatively, methods must be based on the passive electrical properties of living tissues, as they can take advantage of the fundamental role that ionic permeability plays in such properties. For such techniques, measurement of the translayer electrical resistance (TER) has been consistently used to examine the ion transport mechanisms in the corneal epithelial cells; however, this technique has been only possible in vitro. To enhance the applications of this method, in this work we present a novel sensor to perform non-invasive in vivo TER measurements. Herein, the epithelial permeability was assessed using non-invasive tetrapolar impedance measurements that were performed with four electrodes placed on the corneal surface. The geometry of these electrodes was previously optimized to maximize the sensitivity of the corneal epithelium. To evaluate the feasibility of this sensor, the permeability of a rabbit corneal epithelium was monitored by applying a solution of benzalkonium chloride (0.05% BAC). The results validate the capability of the sensor to evaluate the cornea epithelial permeability in vivo.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Eletrodos , Epitélio Corneano/fisiologia , Pletismografia de Impedância/instrumentação , Animais , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Permeabilidade , Coelhos
20.
Artigo em Inglês | MEDLINE | ID: mdl-21096825

RESUMO

Successful management of cardiac heart failure requires a multifactorial approaching. It has been suggested that implantable hemodynamic long-term monitoring can improve patient care. This paper presents an analysis of the hemodynamic parameters commonly recorded, the most used implantable devices and their associated clinical trials. Newly implantable miniaturized sensors and devices are revisited. Finally, a newly implantable conductance-catheter based system is presented. The feasibility to realise volume and pressure measurements in the human left ventricular cavity using an implantable conductance-catheter based system is evaluated. It has the advantage to obtain LV signals continuously. In addition, it allows to realise maneuvers such as calibration and LV function by telemetry being avoiding patient hospitalizations. The rapid advances in device monitoring capabilities could change the new paradigm of the heart disease management.


Assuntos
Determinação da Pressão Arterial/instrumentação , Determinação do Volume Sanguíneo/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres de Demora , Condutometria/instrumentação , Monitorização Ambulatorial/instrumentação , Telemetria/instrumentação , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Avaliação da Tecnologia Biomédica