Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 785
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
BMJ Open ; 14(6): e078358, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926145

RESUMO

INTRODUCTION: The treatment of patients with cardiogenic shock (CS) encompasses several health technologies including Impella pumps and venoarterial extracorporeal membrane oxygenation (VA-ECMO). However, while they are widely used in clinical practice, information on resource use and quality of life (QoL) associated with these devices is scarce. The aim of this study is, therefore, to collect and comparatively assess clinical and socioeconomic data of Impella versus VA-ECMO for the treatment of patients with severe CS, to ultimately conduct both a cost-effectiveness (CEA) and budget impact (BIA) analyses. METHODS AND ANALYSIS: This is a prospective plus retrospective, multicentre study conducted under the scientific coordination of the Center for Research on Health and Social Care Management of SDA Bocconi School of Management and clinical coordination of Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) San Raffaele Scientific Institute in Milan. The Impella Network stemmed for the purposes of this study and comprises 17 Italian clinical centres from Northern to Southern Regions in Italy. The Italian network qualifies as a subgroup of the international Impella Cardiac Surgery Registry. Patients with CS treated with Impella pumps (CP, 5.0 or 5.5) will be prospectively recruited, and information on clinical outcomes, resource use and QoL collected. Economic data will be retrospectively matched with data from comparable patients treated with VA-ECMO. Both CEA and BIA will be conducted adopting the societal perspective in Italy. This study will contribute to generate new socioeconomic evidence to inform future coverage decisions. ETHICS AND DISSEMINATION: As of May 2024, most of the clinical centres submitted the documentation to their ethical committee (N=13; 76%), six centres received ethical approval and two centres started to enrol patients. Study results will be published in peer-reviewed publications and disseminated through conference presentations.


Assuntos
Análise Custo-Benefício , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/economia , Oxigenação por Membrana Extracorpórea/economia , Oxigenação por Membrana Extracorpórea/métodos , Coração Auxiliar/economia , Estudos Prospectivos , Estudos Retrospectivos , Itália , Qualidade de Vida , Estudos Multicêntricos como Assunto , Orçamentos , Estudos Observacionais como Assunto
2.
J Am Heart Assoc ; 13(11): e034645, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38804220

RESUMO

BACKGROUND: Evidence on the comparative outcomes following percutaneous microaxial ventricular assist devices (pVAD) versus intra-aortic balloon pump for nonacute myocardial infarction cardiogenic shock is limited. METHODS AND RESULTS: We included 704 and 2140 Medicare fee-for-service beneficiaries aged 65 to 99 years treated with pVAD and intra-aortic balloon pump, respectively, for nonacute myocardial infarction cardiogenic shock from 2016 to 2020. Patients treated using pVAD compared with those treated using intra-aortic balloon pump were more likely to be concurrently treated with mechanical ventilation, renal replacement therapy, and blood transfusions. We computed propensity scores for undergoing pVAD using patient- and hospital-level factors and performed a matching weight analysis. The use of pVAD was associated with higher 30-day mortality (adjusted odds ratio, 1.92 [95% CI, 1.59-2.33]) but not associated with in-hospital bleeding (adjusted odds ratio, 1.00 [95% CI, 0.81-1.24]), stroke (adjusted odds ratio, 0.91 [95% CI, 0.56-1.47]), sepsis (OR, 0.91 [95% CI, 0.64-1.28]), and length of hospital stay (adjusted mean difference, +0.4 days [95% CI, -1.4 to +2.3]). A quasi-experimental instrumental variable analysis using the cross-sectional institutional practice preferences showed similar patterns, though not statistically significant (adjusted odds ratio, 1.38; 95% CI, 0.28-6.89). CONCLUSIONS: Our investigation using the national sample of Medicare beneficiaries showed that the use of pVAD compared with intra-aortic balloon pump was associated with higher mortality in patients with nonacute myocardial infarction cardiogenic shock. Providers should be cautious about the use of pVAD for nonacute myocardial infarction cardiogenic shock, while adequately powered high-quality randomized controlled trials are warranted to determine the clinical effects of pVAD.


Assuntos
Coração Auxiliar , Balão Intra-Aórtico , Infarto do Miocárdio , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Balão Intra-Aórtico/mortalidade , Masculino , Idoso , Feminino , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Idoso de 80 Anos ou mais , Estados Unidos/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Medicare
3.
J Appl Clin Med Phys ; 25(7): e14386, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38739330

RESUMO

PURPOSE: Photon counting CT (PCCT) holds promise for mitigating metal artifacts and can produce virtual mono-energetic images (VMI), while maintaining temporal resolution, making it a valuable tool for characterizing the heart. This study aimed to evaluate and optimize PCCT for cardiac imaging in patients during left ventricular assistance device (LVAD) therapy by conducting an in-depth objective assessment of metal artifacts and visual grading. METHODS: Various scan and reconstruction settings were tested on a phantom and further evaluated on a patient acquisition to identify the optimal protocol settings. The phantom comprised an empty thoracic cavity, supplemented with heart and lungs from a cadaveric lamb. The heart was implanted with an LVAD (HeartMate 3) and iodine contrast. Scans were performed on a PCCT (NAEOTOM Alpha, Siemens Healthcare). Metal artifacts were assessed by three objective methods: Hounsfield units (HU)/SD measurements (DiffHU and SDARTIFACT), Fourier analysis (AmplitudeLowFreq), and depicted LVAD volume in the images (BloomVol). Radiologists graded metal artifacts and the diagnostic interpretability in the LVAD lumen, cardiac tissue, lung tissue, and spinal cord using a 5-point rating scale. Regression and correlation analysis were conducted to determine the assessment method most closely associated with acquisition and reconstruction parameters, as well as the objective method demonstrating the highest correlation with visual grading. RESULTS: Due to blooming artifacts, the LVAD volume fluctuated between 27.0 and 92.7 cm3. This variance was primarily influenced by kVp, kernel, keV, and iMAR (R2 = 0.989). Radiologists favored pacemaker iMAR, 3 mm slice thickness, and T3D keV and kernel Bv56f for minimal metal artifacts in cardiac tissue assessment, and 110 keV and Qr40f for lung tissue interpretation. The model adequacy for DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was 0.28, 0.76, 0.29, and 0.99 respectively for phantom data, and 0.95, 0.98, 1.00, and 0.99 for in-vivo data. For in-vivo data, the correlation between visual grading (VGSUM) and DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was -0.16, -0.01, -0.48, and -0.40 respectively. CONCLUSION: We found that optimal scan settings for LVAD imaging involved using 120 kVp and IQ level 80. Employing T3D with pacemaker iMAR, the sharpest allowed vascular kernel (Bv56f), and VMI at 110 keV with kernel Qr40 yields images suitable for cardiac imaging during LVAD-therapy. Volumetric measurements of the LVAD for determination of the extent of blooming artifacts was shown to be the best objective method to assess metal artifacts.


Assuntos
Artefatos , Coração Auxiliar , Metais , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Ovinos , Animais , Coração/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
4.
Heart Lung ; 66: 56-70, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38583277

RESUMO

BACKGROUND: Social determinants of health (SDOH) may influence the clinical management of patients with heart failure. Further research is warranted on the relationship between SDOH and Ventricular Assist Device (VAD) therapy for heart failure. OBJECTIVES: The purpose of this integrative review was to synthesize the state of knowledge on the intersection of SDOH with VAD therapy. METHODS: Guided by Whittemore and Knafl's methodology, this literature search captured three concepts of interest including VAD therapy, SDOH, and their domains of intersection with patient selection, decision-making, treatment outcome, and resource allocation. CINAHL, Embase, PsycINFO, PubMed, and Web of Science were searched in March 2023. Articles were included if they were peer-reviewed publications in English, published between 2006 and 2023, conducted in the United States, and examined VAD therapy in the context of adult patients (age ≥ 18 years). RESULTS: 22 quantitative studies meeting the inclusion criteria informed the conceptualization of SDOH using the Healthy People 2030 framework. Four themes captured how the identified SDOH intersected with different processes relating to VAD therapy: patient decision-making, healthcare access and resource allocation, patient selection, and treatment outcomes. Most studies addressed the intersection of SDOH with healthcare access and treatment outcomes. CONCLUSION: This review highlights substantial gaps in understanding how SDOH intersect with patient and patient selection for VAD. More research using mixed methods designs is warranted. On an institutional level, addressing bias and discrimination may have mitigated health disparities with treatment outcomes, but further research is needed for implementing system-wide change. Standardized assessment of SDOH is recommended throughout clinical practice from patient selection to outpatient VAD care.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Determinantes Sociais da Saúde , Humanos , Coração Auxiliar/estatística & dados numéricos , Insuficiência Cardíaca/terapia , Seleção de Pacientes
6.
Prehosp Disaster Med ; 39(2): 136-141, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38445327

RESUMO

BACKGROUND: Patients with ventricular assist devices (VADs) represent a growing population presenting to Emergency Medical Services (EMS), but little is known about their prehospital care. This study aimed to characterize current EMS protocols in the United States for patients with VADs. METHODS: States with state-wide EMS protocols were included. Protocols were obtained from the state EMS website. If not available, the office of the state medical director was contacted. For each state, protocols were analyzed for patient and VAD assessment and treatment variables. RESULTS: Of 32 states with state-wide EMS protocols, 21 had VAD-specific protocols. With 17 (81%) states noting a pulse may not be palpable, protocols recommended assessing alternate measures of perfusion and mean arterial pressure (MAP; 15 [71%]). Assessment of VAD was advised through listening for pump hum (20 [95%]) and alarms (20 [95%]) and checking the power supply (15 [71%]). For treatment, EMS prehospital consultation was required to begin chest compression in three (14%) states, and mechanical (device) chest compressions were not permitted in two (10%) states. Contact information for VAD coordinator was listed in a minority of five (24%) states. Transport of VAD equipment/backup bag was advised in 18 (86%) states. DISCUSSION: This national analysis of EMS protocols found VAD-specific EMS protocols are not universally adopted in the United States and are variable when implemented, highlighting a need for VAD teams to partner with EMS agencies to inform standardized protocols that optimize these patients' care.


Assuntos
Serviços Médicos de Emergência , Coração Auxiliar , Humanos , Estados Unidos , Protocolos Clínicos , Insuficiência Cardíaca/terapia , Masculino
7.
J Heart Lung Transplant ; 43(6): 996-998, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342158

RESUMO

Racial and ethnic disparities in provision of left ventricular assist device (LVAD) therapy have been identified. These disparities may be at least partially related to socioeconomic factors, including social support networks and financial constraints. This study aimed to identify specific barriers, and variations in institutional approaches, to the provision of equitable care to underserved populations. A survey was administered to 237 LVAD program personnel, including physicians, LVAD coordinators, and social workers, at more than 100 LVAD centers across 7 countries. Three fourths of respondents reported that their program required a support person to live with the LVAD patient for some period of time following implantation. In addition, 31% of respondents reported that patients with the inability to pay for medications are turned down at their program. The most significant barriers to successful LVAD implantation were lack of social support, lack of insurance, and lack of timely referral. The most consistently identified supports needed from the hospital system for success in underserved populations were the provision of a solution for patient transportation to and from hospital visits and the provision of financial support. This survey highlights the challenges facing LVAD programs that care for underserved patient populations and sets the stage for specific interventions aimed at reducing disparities in access to care.


Assuntos
Acessibilidade aos Serviços de Saúde , Coração Auxiliar , Apoio Social , Humanos , Insuficiência Cardíaca/terapia , Inquéritos e Questionários , Masculino , Disparidades em Assistência à Saúde , Feminino , Fatores Socioeconômicos
8.
J Heart Lung Transplant ; 43(6): 920-930, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38408549

RESUMO

BACKGROUND: Socioeconomic deprivation is associated with a lower likelihood of referral for advanced heart failure (HF) evaluation, but it is not known whether it influences rates of advanced HF therapies independently of key hemodynamic measures and comorbidity following advanced HF evaluation in a universal healthcare system. METHODS: We linked data from a single-center Danish clinical registry of consecutive patients evaluated for advanced HF with patient-level information on socioeconomic status. Patients were divided into groups based on the level of education (low, medium, and high), combined degree of socioeconomic deprivation (low, medium, and high), and household income quartiles. Rates of the combined outcome of left ventricular assist device implantation or heart transplantation (advanced HF therapy) with death as a competing risk were estimated with cumulative incidence functions, and Cox proportional hazards models adjusted for age, sex, central venous pressure, cardiac index, and comorbidities. RESULTS: We included 629 patients, median age 53 years, of whom 77% were men. During a median follow-up of 5 years, 179 (28%) underwent advanced HF therapy. The highest level of education was associated with higher rates (high vs low, adjusted HR 1.81 95% CI 1.14-2.89, p = 0.01), whereas household income quartile groups (Q4 vs Q1, adjusted HR 1.37 95% CI 0.76-2.47, p = 0.30) or groups of combined socioeconomic deprivation (high vs low degree of deprivation, adjusted HR 0.86 95% CI 0.50-1.46, p = 0.56) were not significantly associated with rates of advanced HF therapy. CONCLUSIONS: Patients with a lower level of education might be disfavored for advanced HF therapies and could require specific attention in the advanced HF care center.


Assuntos
Insuficiência Cardíaca , Classe Social , Humanos , Insuficiência Cardíaca/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Dinamarca/epidemiologia , Sistema de Registros , Transplante de Coração , Coração Auxiliar , Adulto , Seguimentos , Idoso , Estudos Retrospectivos
9.
Heart Fail Rev ; 29(2): 559-569, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38329583

RESUMO

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Transplante de Coração/efeitos adversos , Ecocardiografia , Estudos Retrospectivos
10.
ASAIO J ; 70(6): 469-476, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38181411

RESUMO

We explored whether women undergo continuous-flow left ventricular assist device (CF-LVAD) implantation in later stages of heart failure (HF) than men, evidenced by worse preoperative right HF (RHF). We also compared two propensity models with and without preoperative RHF to assess its effect on outcomes. INTERMACS was queried from July 2008 to December 2017. Propensity model 1 matched men and women on age ≥50 years, HF etiology, body surface area, INTERMACS class, comorbidities, device strategy, temporary mechanical circulatory support, and device type. Model 2 included these variables plus LV end-diastolic diameter, right atrial pressure/pulmonary capillary wedge pressure, pulmonary artery pulsatility index, and right ventricular ejection fraction. The primary outcome was all-cause mortality. Secondary outcomes comprise RHF, rehospitalization, renal dysfunction, stroke, and device malfunction. In model 1, characteristics were comparable between 3,195 women and 3,195 men, except women more often had preoperative RHF and postoperative right VAD support and had worse 1 year and overall survival. In model 2, after propensity matching for additional risk factors for preoperative RHF, 1,119 women and 1,119 men had comparable post-LVAD implant RVAD use and survival. These findings suggest that women present more often with biventricular failure and after implantation have higher RHF and mortality rates.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Feminino , Masculino , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/fisiopatologia , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Estudos Retrospectivos , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/etiologia
11.
Hellenic J Cardiol ; 76: 31-39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37295667

RESUMO

OBJECTIVES: The study aimed to compare pre- and postoperative resting as well as postprocedural resting and exertional right ventricular speckle-tracking echocardiographic parameters at a mid-term follow-up after left ventricular assist device (LVAD) implantation. METHODS: Patients with implanted third-generation LVADs with hydrodynamic bearings were prospectively enrolled (NCT05063006). Myocardial deformation was evaluated before pump implantation and at least three months after the procedure, both at rest and during exercise. RESULTS: We included 22 patients, 7.3 months (IQR, 4.7-10.2) after the surgery. The mean age was 58.4 ± 7 years, 95.5% were men, and 45.5% had dilated cardiomyopathy. The RV strain analysis was feasible in all subjects both at rest and during exercise. The RV free wall strain (RVFWS) worsened from -13% (IQR, -17.3 to -10.9) to -11.3% (IQR, -12.9 to -6; p = 0.033) after LVAD implantation with a particular decline in the apical RV segment [-11.3% (IQR, -16.4 to -6.2) vs -7.8% (IQR, -11.7 to -3.9; p = 0.012)]. The RV four-chamber longitudinal strain (RV4CSL) remained unchanged [-8.5% (IQR, -10.8 to -6.9) vs -7.3% (IQR, -9.8 to -4.7; p = 0.184)]. Neither RVFWS (-11.3% (IQR, -12.9 to -6) vs -9.9% (IQR, -13.5 to -7.5; p = 0.077) nor RV4CSL [-7.3% (IQR, -9.8 to -4.7) vs -7.9% (IQR, -9.8 to -6.3; p = 0.548)] changed during the exercise test. CONCLUSIONS: In patients who are pump-supported, the right ventricular free wall strain tends to worsen after LVAD implantation and remains unchanged during a cycle ergometer stress test.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ecocardiografia/métodos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Função Ventricular Direita
12.
J Med Econ ; 27(1): 62-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084737

RESUMO

BACKGROUND: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections. METHODS: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019. Cumulative incidence of infection was calculated. Infection and non-infection cohorts were compared regarding mortality, healthcare utilization, and total cost. Regression models were used to identify risk factors associated with infections and mortality. RESULTS: A total of 2,259 patients with a VAD implant were included, with 369 experiencing infection (12-month cumulative incidence 16.1%). Patients with infection were 2.1 times more likely to die (p < 0.001, 95% CI [1.5-2.9]). The mean 12-month total cost per US patient was $354,339 for the non-infection cohort and $397,546 for the infection cohort, a difference of $43,207 (p < 0.0001). CONCLUSIONS: VAD infections were associated with higher mortality, more healthcare utilization, and higher total cost. Strategies to minimize VAD-specific infections could lead to improved clinical and economic outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estados Unidos/epidemiologia , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Revisão da Utilização de Seguros , Fatores de Risco , Resultado do Tratamento
14.
Artif Organs ; 48(2): 182-190, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37787082

RESUMO

BACKGROUND: The objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop. METHODS: Two UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility. RESULTS: The aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support. CONCLUSIONS: The UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , China , Etnicidade , Hemodinâmica , Débito Cardíaco , Insuficiência Cardíaca/cirurgia
15.
Artif Organs ; 48(1): 61-69, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37787101

RESUMO

BACKGROUND: ModulHeart (Puzzle Medical Devices Inc) is a novel percutaneous flow entrainment pump anchored in the descending aorta. The current study evaluates the hemodynamic effect of ModulHeart support and its impact on cerebral, myocardial, and renal blood flow. METHODS: ModulHeart was implanted in the descending aorta of four healthy calves. A ramp protocol (2000 RPM increments) was performed with the pump operating at five different speeds from 14 000 to 22 000 RPM. For each speed, pressures proximal and distal to the pump, and right heart catheterization measurements were recorded. Stable-isotope labeled microspheres were injected in the left ventricle to evaluate organ perfusion. RESULTS: Thermodilution cardiac output increased by 23% at 22 000 RPM. Greater pump speeds resulted in greater pump gradients, up to 10 mm Hg in mean arterial pressure at 22 000 RPM, without significant reduction of proximal perfusion pressures. Arterial pulse pressure remained stable at all speeds. ModulHeart was not associated with a reduction in cerebral or myocardial blood flow at any speed. Renal cortical and medullary blood flow increased by up to 50% and 40%, respectively. CONCLUSION: The ModulHeart device implanted in the descending aorta of healthy calves resulted in significant arterial pressure gradients and preserved pulse pressure. Greater pump speeds translated into greater increases in renal blood flow, with no decrease in cerebral or myocardial perfusion.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Animais , Bovinos , Humanos , Insuficiência Cardíaca/terapia , Hemodinâmica/fisiologia , Pressão Sanguínea , Miocárdio , Ventrículos do Coração
16.
IEEE Trans Biomed Eng ; 71(5): 1651-1662, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38133971

RESUMO

OBJECTIVE: Conventional mock circulatory loops (MCLs) cannot replicate realistic hemodynamic conditions without inducing blood trauma. This constrains in-vitro hemocompatibility examinations of blood pumps to static test loops that do not mimic clinical scenarios. This study aimed at developing an atraumatic MCL based on a hardware-in-the-loop concept (H-MCL) for realistic hemocompatibility assessment. METHODS: The H-MCL was designed for 450 ± 50 ml of blood with the polycarbonate reservoirs, the silicone/polyvinyl-chloride tubing, and the blood pump under investigation as the sole blood-contacting components. To account for inherent coupling effects a decoupling pressure control was derived by feedback linearization, whereas the level control was addressed by an optimization task to overcome periodic loss of controllability. The HeartMate 3 was showcased to evaluate the H-MCL's accuracy at typical hemodynamic conditions. To verify the atraumatic properties of the H-MCL, hemolysis (bovine blood, n = 6) was evaluated using the H-MCL in both inactive (static) and active (minor pulsatility) mode, and compared to results achieved in conventional loops. RESULTS: Typical hemodynamic scenarios were replicated with marginal coupling effects and root mean square error (RMSE) below 1.74 ± 1.37 mmHg while the fluid level remained within ±4% of its target value. The normalized indices of hemolysis (NIH) for the inactive H-MCL showed no significant differences to conventional loops ( ∆NIH = -1.6 mg/100 L). Further, no significant difference was evident between the active and inactive mode in the H-MCL ( ∆NIH = +0.3 mg/100 L). CONCLUSION AND SIGNIFICANCE: Collectively, these findings indicated the H-MCL's potential for in-vitro hemocompatibility assessment of blood pumps within realistic hemodynamic conditions, eliminating inherent setup-related risks for blood trauma.


Assuntos
Coração Auxiliar , Hemólise , Animais , Hemólise/fisiologia , Bovinos , Desenho de Equipamento , Hemodinâmica/fisiologia , Teste de Materiais/métodos , Modelos Cardiovasculares , Humanos
17.
Artigo em Inglês | MEDLINE | ID: mdl-38082936

RESUMO

Accurate assessment of myocardial recovery (MR) under left ventricular assist device (LVAD) support is essential for clinicians to manage heart failure patients. However, current techniques for assessing MR are time-consuming, invasive, and infrequent. Measuring MR using indices derived from LVAD operating data instead provides a potential real-time alternative. Several of these indices for assessing the MR of LVAD-supported heart failure patients were collated from the literature and subject to a comprehensive comparative analysis. The objective of this analysis was to determine the most accurate index for assessing systolic cardiac function under LVAD-support, characterized by maximal end-systolic elastance (Emax), while remaining insensitive to preload & afterload. The indices were compared in computational simulation, utilizing an LVAD + cardiovascular system model to sweep through a large array of Emax and resistance conditions. Results demonstrated the index that correlated best with Emax, showing the highest accuracy, was the ratio between maximum flow acceleration and flow pulsatility (average R2 =0.9790). The same index also exhibited the lowest % variation (sensitivity) to preload & afterload (1.32% & 13.53% respectively). However, opportunities for improvement remain among current recovery assessment indices, with this study providing a baseline of performance for potential future indices to improve upon.Clinical relevance- This study presents a potential real-time measure of native cardiac function in LVAD-supported heart failure patients to support patient management and further recovery.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Miocárdio , Sístole
18.
JAMA Cardiol ; 8(8): 744-754, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342056

RESUMO

Importance: Recent studies have produced inconsistent findings regarding the outcomes of the percutaneous microaxial left ventricular assist device (LVAD) during acute myocardial infarction with cardiogenic shock (AMICS). Objective: To compare the percutaneous microaxial LVAD vs alternative treatments among patients presenting with AMICS using observational analyses of administrative data. Design, Setting, and Participants: This comparative effectiveness research study used Medicare fee-for-service claims of patients admitted with AMICS undergoing percutaneous coronary intervention from October 1, 2015, through December 31, 2019. Treatment strategies were compared using (1) inverse probability of treatment weighting to estimate the effect of different baseline treatments in the overall population; (2) instrumental variable analysis to determine the effectiveness of the percutaneous microaxial LVAD among patients whose treatment was influenced by cross-sectional institutional practice patterns; (3) an instrumented difference-in-differences analysis to determine the effectiveness of treatment among patients whose treatment was influenced by longitudinal changes in institutional practice patterns; and (4) a grace period approach to determine the effectiveness of initiating the percutaneous microaxial LVAD within 2 days of percutaneous coronary intervention. Analysis took place between March 2021 and December 2022. Interventions: Percutaneous microaxial LVAD vs alternative treatments (including medical therapy and intra-aortic balloon pump). Main Outcomes and Measures: Thirty-day all-cause mortality and readmissions. Results: Of 23 478 patients, 14 264 (60.8%) were male and the mean (SD) age was 73.9 (9.8) years. In the inverse probability of treatment weighting analysis and grace period approaches, treatment with percutaneous microaxial LVAD was associated with a higher risk-adjusted 30-day mortality (risk difference, 14.9%; 95% CI, 12.9%-17.0%). However, patients receiving the percutaneous microaxial LVAD had a higher frequency of factors associated with severe illness, suggesting possible confounding by measures of illness severity not available in the data. In the instrumental variable analysis, 30-day mortality was also higher with percutaneous microaxial LVAD, but patient and hospital characteristics differed across levels of the instrumental variable, suggesting possible confounding by unmeasured variables (risk difference, 13.5%; 95% CI, 3.9%-23.2%). In the instrumented difference-in-differences analysis, the association between the percutaneous microaxial LVAD and mortality was imprecise, and differences in trends in characteristics between hospitals with different percutaneous microaxial LVAD use suggested potential assumption violations. Conclusions: In observational analyses comparing the percutaneous microaxial LVAD to alternative treatments among patients with AMICS, the percutaneous microaxial LVAD was associated with worse outcomes in some analyses, while in other analyses, the association was too imprecise to draw meaningful conclusions. However, the distribution of patient and institutional characteristics between treatment groups or groups defined by institutional differences in treatment use, including changes in use over time, combined with clinical knowledge of illness severity factors not captured in the data, suggested violations of key assumptions that are needed for valid causal inference with different observational analyses. Randomized clinical trials of mechanical support devices will allow valid comparisons across candidate treatment strategies and help resolve ongoing controversies.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Humanos , Masculino , Idoso , Estados Unidos/epidemiologia , Feminino , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Coração Auxiliar/efeitos adversos , Estudos Transversais , Medicare , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Infarto do Miocárdio/fisiopatologia
19.
Am J Transplant ; 23(7): 1048-1057, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37059177

RESUMO

Nontuberculous mycobacteria are emerging pathogens, yet data on the epidemiology and management of extrapulmonary nontuberculous mycobacteria infections in orthotopic heart transplantation (OHT) and ventricular assist device (VAD) recipients are scarce. We retrospectively reviewed records of OHT and VAD recipients who underwent cardiac surgery at our hospital and developed Mycobacterium abscessus complex (MABC) infection from 2013 to 2016 during a hospital outbreak of MABC linked to heater-cooler units. We analyzed patient characteristics, medical and surgical management, and long-term outcomes. Ten OHT patients and 7 patients with VAD developed extrapulmonary M. abscessus subspecies abscessus infection. The median time from presumed inoculation during cardiac surgery to the first positive culture was 106 days in OHT and 29 days in VAD recipients. The most common sites of positive cultures were blood (n = 12), sternum/mediastinum (n = 8), and the VAD driveline exit site (n = 7). The 14 patients diagnosed when alive received combination antimicrobial therapy for a median of 21 weeks, developed 28 antibiotic-related adverse events, and underwent 27 surgeries. Only 8 (47%) patients survived longer than 12 weeks after diagnosis, including 2 patients with VAD who experienced long-term survival after an explantation of infected VADs and OHT. Despite aggressive medical and surgical management, OHT and VAD patients with MABC infection experienced substantial morbidity and mortality.


Assuntos
Transplante de Coração , Coração Auxiliar , Infecções por Mycobacterium não Tuberculosas , Mycobacterium abscessus , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Infecções por Mycobacterium não Tuberculosas/tratamento farmacológico , Infecções por Mycobacterium não Tuberculosas/epidemiologia
20.
J Heart Lung Transplant ; 42(6): 689-692, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36973094

RESUMO

BACKGROUND: Guidelines recommend incorporation of caregiver burden assessment and list significant caregiver burden as a relative contraindication when considering left-ventricular assist device (LVAD) implantation. METHODS: To assess national practices regarding caregiver burden assessment, in 2019 we administered a 47-item survey to LVAD clinicians using 4 convenience samples. RESULTS: Responses were obtained from 191 registered nurses, 109 advance practice providers, 71 physicians, 59 social workers, and 40 others representing 132 LVAD programs; 125 of 173 total United States programs were included in the final analysis. While most programs (83.2%) assessed caregiver burden, assessment was most frequently conducted informally during social work evaluation (83.2%), with only 8.8% incorporating validated measures of caregiver burden. Larger programs were more likely to use a validated assessment measure (OR 6.68 [1.33-33.52]). CONCLUSIONS: Future research should focus on how programs can standardize caregiver burden assessment and how the level of burden may impact patient and caregiver outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Sobrecarga do Cuidador , Resultado do Tratamento , Cuidadores , Pacientes , Insuficiência Cardíaca/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA