Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 58(6): 846-852, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33998082

RESUMO

OBJECTIVE: To investigate prenatal changes in cardiac biometric and flow parameters in fetuses with bicuspid aortic valve (BAV) diagnosed neonatally compared with controls with normal cardiac anatomy. METHODS: This analysis was conducted as part of the Copenhagen Baby Heart Study, a multicenter cohort study of 25 556 neonates that underwent second-trimester anomaly scan at 18 + 0 to 22 + 6 weeks' gestation and neonatal echocardiography within 4 weeks after birth, in Copenhagen University Hospital Herlev, Hvidovre Hospital and Rigshospitalet in greater Copenhagen, between April 2016 and October 2018. From February 2017 (Rigshospitalet) and September 2017 (Herlev and Hvidovre hospitals), the protocol for second-trimester screening of the heart was extended to include evaluation of the four-chamber view, with assessment of flow across the atrioventricular valves, sagittal view of the aortic arch and midumbilical artery and ductus venosus pulsatility indices. All images were evaluated by two investigators, and cardiac biometric and flow parameters were measured and compared between cases with BAV and controls. All cases with neonatal BAV were assessed by a specialist. Maternal characteristics and first- and second-trimester biomarkers were also compared between the two groups. RESULTS: Fifty-five infants with BAV and 8316 controls with normal cardiac anatomy were identified during the study period and assessed using the extended prenatal cardiac imaging protocol. There were three times as many mothers who smoked before pregnancy in the group with BAV as in the control group (9.1% vs 2.7%; P = 0.003). All other baseline characteristics were similar between the two groups. Fetuses with BAV, compared with controls, had a significantly larger diameter of the aorta at the level of the aortic valve (3.1 mm vs 3.0 mm (mean difference, 0.12 mm (95% CI, 0.03-0.21 mm))) and the pulmonary artery at the level of the pulmonary valve (4.1 mm vs 3.9 mm (mean difference, 0.15 mm (95% CI, 0.03-0.28 mm))). Following conversion of the diameter measurements of the aorta and pulmonary artery to Z-scores and Bonferroni correction, the differences between the two groups were no longer statistically significant. Pregnancy-associated plasma protein-A (PAPP-A) multiples of the median (MoM) was significantly lower in the BAV group than in the control group (0.85 vs 1.03; P = 0.04). CONCLUSIONS: Our findings suggest that fetuses with BAV may have a larger aortic diameter at the level of the aortic valve, measured in the left-ventricular-outflow-tract view, and a larger pulmonary artery diameter at the level of the pulmonary valve, measured in the three-vessel view, at 20 weeks' gestation. Moreover, we found an association of maternal smoking and low PAPP-A MoM with BAV. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Doença da Válvula Aórtica Bicúspide/diagnóstico , Biometria , Ecocardiografia , Coração Fetal/fisiopatologia , Ultrassonografia Pré-Natal , Adulto , Aorta/diagnóstico por imagem , Aorta/embriologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/embriologia , Doença da Válvula Aórtica Bicúspide/embriologia , Circulação Sanguínea , Estudos de Casos e Controles , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Feto/irrigação sanguínea , Feto/diagnóstico por imagem , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Gravidez , Segundo Trimestre da Gravidez , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/embriologia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/embriologia
2.
Medicine (Baltimore) ; 100(4): e24427, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33530242

RESUMO

ABSTRACT: The quality control of fetal sonographic (FS) images is essential for the correct biometric measurements and fetal anomaly diagnosis. However, quality control requires professional sonographers to perform and is often labor-intensive. To solve this problem, we propose an automatic image quality assessment scheme based on multitask learning to assist in FS image quality control. An essential criterion for FS image quality control is that all the essential anatomical structures in the section should appear full and remarkable with a clear boundary. Therefore, our scheme aims to identify those essential anatomical structures to judge whether an FS image is the standard image, which is achieved by 3 convolutional neural networks. The Feature Extraction Network aims to extract deep level features of FS images. Based on the extracted features, the Class Prediction Network determines whether the structure meets the standard and Region Proposal Network identifies its position. The scheme has been applied to 3 types of fetal sections, which are the head, abdominal, and heart. The experimental results show that our method can make a quality assessment of an FS image within less a second. Also, our method achieves competitive performance in both the segmentation and diagnosis compared with state-of-the-art methods.


Assuntos
Feto/diagnóstico por imagem , Redes Neurais de Computação , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Ultrassonografia Pré-Natal/normas , Abdome/diagnóstico por imagem , Abdome/embriologia , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Cabeça/diagnóstico por imagem , Cabeça/embriologia , Humanos , Gravidez , Padrões de Referência
3.
Ultrasound Obstet Gynecol ; 55(6): 758-767, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31945242

RESUMO

OBJECTIVE: To compare the recommended three-view fetal heart screening method to detect major congenital heart disease (CHD) with more elaborate screening strategies to determine the cost-effective strategy in unselected (low-risk) pregnancies. METHODS: A decision-analytic model was designed to compare four screening strategies to identify fetuses with major CHD in a theoretical cohort of 4 000 000 births in the USA. The four strategies were: (1) three views: four-chamber view (4CV) and views of the left (LVOT) and right (RVOT) ventricular outflow tracts; (2) five views: 4CV, LVOT, RVOT and longitudinal views of the ductal arch and aortic arch; (3) five axial views: 4CV, LVOT, RVOT, three-vessel (3V) view and three-vessels-and-trachea view; and (4) six views: 4CV, LVOT, RVOT and 3V views and longitudinal views of the ductal arch and aortic arch. Outcomes related to neonatal mortality and neurodevelopmental disability were evaluated. The analysis was performed from a healthcare-system perspective, with a cost-effectiveness willingness-to-pay threshold set at $100 000 per quality-adjusted life year (QALY). Baseline analysis, one-way sensitivity analysis and Monte-Carlo simulation were performed. RESULTS: In our baseline model, screening with five axial views was the optimal strategy, detecting 3520 more CHDs, and resulting in 259 fewer children with neurodevelopmental disability, 40 fewer neonatal deaths and only slightly higher costs, compared with screening with the currently recommended three views. Screening with six views was more effective, but also cost considerably more, compared with screening with five axial views, and had an incremental cost of $490 023/QALY, which was over the willingness-to-pay threshold. The five-view strategy was dominated by the other three strategies, i.e. it was more costly and less effective in comparison. The data were robust when tested with Monte-Carlo and one-way sensitivity analysis. CONCLUSION: Although current guidelines recommend a minimum of three views for detecting CHD during the mid-trimester anatomy scan, screening with five axial views is a cost-effective strategy that may lead to improved outcome compared with three-view screening. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ecocardiografia/economia , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/economia , Estudos de Coortes , Análise Custo-Benefício , Ecocardiografia/métodos , Feminino , Coração Fetal/embriologia , Cardiopatias Congênitas/embriologia , Humanos , Método de Monte Carlo , Gravidez , Anos de Vida Ajustados por Qualidade de Vida , Ultrassonografia Pré-Natal/métodos
4.
J Obstet Gynaecol Res ; 46(1): 31-38, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31595615

RESUMO

The circulatory physiology of fetuses differs from that of neonates. The concept of biventricular combined cardiac output is necessary to understand and assess the fetal cardiac function. Fetal cardiac function has been estimated using echocardiographic methods such as M-mode, B-mode and pulsed wave Doppler. In addition, recent studies have reported the utility of tissue Doppler imaging in fetal echocardiography. However, parameters for fetal cardiac function remain to be established. Recently, we developed two novel techniques for assessing fetal cardiac function: an automatic fractional shortening method and E/e' determination using the dual-gate Doppler method. These two techniques are expected to be reliable and useful for assessing the fetal status in various pathological conditions.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Débito Cardíaco , Feminino , Coração Fetal/embriologia , Humanos , Gravidez , Volume Sistólico
5.
Ultrasound Obstet Gynecol ; 55(4): 516-522, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30989734

RESUMO

OBJECTIVE: EXTrauterine Environment for Neonatal Development (EXTEND) is a system to support ongoing fetal growth and organ development in an extrauterine environment, utilizing a pumpless low-resistance oxygenator circuit. The aim of this study was to evaluate hemodynamics and cardiac function in fetal sheep sustained on the EXTEND system. METHODS: This was a prospective study of fetal sheep supported for a minimum of 3 weeks on EXTEND. Hemodynamic parameters were assessed weekly and included heart rate, mean arterial pressure (MAP), Doppler-echocardiography-derived cardiac output (CO), pulsatility indices (PIs) of the fetal middle cerebral artery (MCA), umbilical artery (UA) and ductus venosus and cardiac function, as assessed by speckle-tracking-derived global longitudinal strain and strain rate in the right (RV) and left (LV) ventricles. Parameters were compared at 0 days and 1, 2 and 3 weeks following placement on EXTEND. RESULTS: Of 10 fetal sheep enrolled, seven survived for 3 weeks and were included in the analysis. Median gestational age at cannulation was 107 (range, 95-109) days. Heart rate decreased and MAP increased significantly, but within acceptable ranges, during the study period. The quantities and relative ratios of right and left CO remained stable within the anticipated physiological range throughout the study period. Vascular tracings and PIs appeared to be similar to those seen normally in the natural in-utero state, with MCA-PI being higher than UA-PI. UA tracings demonstrated maintained abundant diastolic flow despite the absence of placental circulation. In both the RV and LV, strain decreased significantly at 1 and 2 weeks relative to baseline but returned to baseline values by week 3. CONCLUSIONS: The EXTEND mechanical support system replicates natural physiology and creates a stable and sustainable cardiovascular construct that supports growth over a 3-week period. However, there is a period of depressed contractility within the first week with subsequent improvement by week 3. This may reflect a period of physiological accommodation that warrants further investigation. This study lays the foundation for further exploration as the EXTEND system moves towards human application. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Cardiotocografia/métodos , Ecocardiografia Doppler/métodos , Oxigenação por Membrana Extracorpórea , Coração Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Animais , Animais Recém-Nascidos/embriologia , Animais Recém-Nascidos/crescimento & desenvolvimento , Débito Cardíaco , Feminino , Desenvolvimento Fetal/fisiologia , Coração Fetal/embriologia , Coração Fetal/crescimento & desenvolvimento , Feto/embriologia , Feto/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Artéria Cerebral Média/embriologia , Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Ovinos , Fatores de Tempo , Artérias Umbilicais/embriologia
6.
Ultrasound Obstet Gynecol ; 56(5): 705-716, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31614030

RESUMO

OBJECTIVE: To perform a cost-effectiveness analysis of different follow-up strategies for non-obese and obese women who had incomplete fetal cardiac screening for major congenital heart disease (CHD). METHODS: Three decision-analytic models, one each for non-obese, obese and Class-III-obese women, were developed to compare five follow-up strategies for initial suboptimal fetal cardiac screening. The five strategies were: (1) no follow-up ultrasound (US) examination but direct referral to fetal echocardiography (FE); (2) one follow-up US, then FE if fetal cardiac views were still suboptimal; (3) up to two follow-up US, then FE if fetal cardiac views were still suboptimal; (4) one follow-up US and no FE; and (5) up to two follow-up US and no FE. The models were designed to identify fetuses with major CHD in a theoretical cohort of 4 000 000 births in the USA. Outcomes related to neonatal mortality and neurodevelopmental disability were evaluated. A cost-effectiveness willingness-to-pay threshold was set at US$100 000 per quality-adjusted life year (QALY). Base-case and sensitivity analysis and Monte-Carlo simulation were performed. RESULTS: In our base-case models for all body mass index (BMI) groups, no follow-up US, but direct referral to FE led to the best outcomes, detecting 7%, 25% and 82% more fetuses with CHD in non-obese, obese and Class-III-obese women, respectively, compared with the baseline strategy of one follow-up US and no FE. However, no follow-up US, but direct referral to FE was above the US$100 000/QALY threshold and therefore not cost-effective. The cost-effective strategy for all BMI groups was one follow-up US and no FE. Both up to two follow-up US with no FE and up to two follow-up US with FE were dominated (being more costly and less effective), while one follow-up US with FE was over the cost-effectiveness threshold. One follow-up US and no FE was the optimal strategy in 97%, 93% and 86% of trials in Monte-Carlo simulation for non-obese, obese and Class-III-obese models, respectively. CONCLUSION: For both non-obese and obese women with incomplete fetal cardiac screening, the optimal CHD follow-up screening strategy is no further US and immediate referral to FE; however, this strategy is not cost-effective. Considering costs, one follow-up US and no FE is the preferred strategy. For both obese and non-obese women, Monte-Carlo simulations showed clearly that one follow-up US and no FE was the optimal strategy. Both non-obese and obese women with initial incomplete cardiac screening examination should therefore be offered one follow-up US. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Assistência ao Convalescente/economia , Ecocardiografia/economia , Coração Fetal/diagnóstico por imagem , Obesidade Materna/diagnóstico por imagem , Ultrassonografia Pré-Natal/economia , Adulto , Assistência ao Convalescente/métodos , Índice de Massa Corporal , Análise Custo-Benefício , Feminino , Coração Fetal/embriologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/economia , Cardiopatias Congênitas/embriologia , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Método de Monte Carlo , Transtornos do Neurodesenvolvimento/diagnóstico por imagem , Transtornos do Neurodesenvolvimento/economia , Transtornos do Neurodesenvolvimento/etiologia , Obesidade Materna/fisiopatologia , Gravidez , Anos de Vida Ajustados por Qualidade de Vida
7.
J Obstet Gynaecol Res ; 45(11): 2150-2157, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31441198

RESUMO

AIM: To evaluate the level of agreement between M-mode and pulsed-wave tissue Doppler imaging (PW-TDI) techniques in assessing fetal mitral annular plane systolic excursion (MAPSE), tricuspid annular plane systolic excursion (TAPSE) and septal annular plane systolic excursion (SAPSE) in a low-risk population. METHODS: This prospective longitudinal study included healthy fetuses assessed from 18 to 40 weeks of gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE were measured using anatomical M-mode and PW-TDI. The agreement between the two diagnostic tests was assessed using Bland-Altman analysis. RESULTS: Fifty fetuses were included in the final analysis. Mean values of TASPE were higher than that of MAPSE. There was a progressive increase of TAPSE, MAPSE and SAPSE values with advancing gestation. For each parameter assessed, there was an overall good agreement between the measurements obtained with M-mode and PW-TDI techniques. However, the measurements made with M-mode were slightly higher than those obtained with PW-TDI (mean differences: 0.03, 0.05 and 0.03 cm for TAPSE, MAPSE and SAPSE, respectively). When stratifying the analyses by gestational age, the mean values of TAPSE, MAPSE and SAPSE measured with M-Mode were higher compared to those obtained with PW-TDI, although the mean differences between the two techniques tended to narrow with increasing gestation. Tricuspid annular plane systolic excursion, MAPSE and SAPSE measurements were all significantly, positively associated with gestational age (all P < 0.001). CONCLUSION: Fetal atrioventricular annular plane displacement can be assessed with M-mode technique, or with PW-TDI as the velocity-time integral of the myocardial systolic waveform. Atrioventricular annular plane displacement values obtained with M-mode technique are slightly higher than those obtained with PW-TDI.


Assuntos
Ecocardiografia Doppler de Pulso/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Ecocardiografia Doppler de Pulso/métodos , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiologia , Idade Gestacional , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/embriologia , Humanos , Estudos Longitudinais , Valva Mitral/diagnóstico por imagem , Valva Mitral/embriologia , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sístole , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/embriologia , Ultrassonografia Pré-Natal/métodos
8.
J Comput Assist Tomogr ; 43(1): 104-108, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30119066

RESUMO

OBJECTIVE: We attempted to evaluate fetal cardiac activity of congenital heart disease (CHD) and normal heart fetuses by magnetic resonance imaging (MRI). METHODS: We evaluated the fetal cardiac functional assessment and the blood flow of descending aorta at 34 weeks' gestation or more by MRI and compared the results with ultrasonography findings. We measured 6 normal heart fetuses and 14 CHD fetuses. RESULTS: The ejection fraction (EF) and descending aorta blood flow in the CHD group were 76.4% ± 11.9%, 687.5 ± 303.8 mL/min by ultrasonography and 48.3% ± 7.1%, 711.4 ± 273.1 mL/min by MRI; those in the normal group were 66.9% ± 12.2%, 898.1 ± 245.9 mL/min by ultrasonography and 51.3% ± 4.2%, 911.9 ± 223.1 mL/min by MRI. CONCLUSIONS: There was no significant difference in descending aorta blood flow measurements between ultrasonography and MRI, but the EF showed a significant between-group difference. In the normal group, the variation of EF and blood flow measured by MRI was significantly smaller compared with those of ultrasonography.


Assuntos
Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Adulto , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiopatologia , Cardiopatias Congênitas/embriologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Japão , Gravidez , Estudos Prospectivos
9.
Zh Evol Biokhim Fiziol ; 51(5): 362-9, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26856076

RESUMO

A mathematical analysis of correlation of slow-wave processes in the system <> during the last 4 days of bearing was performed in experiments on rat fetuses with retained placental connection with the female. The parallel recording of physiological indicators of the female and fetus state revealed the existence of a relationship between oscillations of heartbeat rhythms and breathing in about-one-minute and many-minute ranges. The highest values of connection between the heart rhythms of female and fetus are characteristic for days 17 and 20 of gestation. On day 18-19 the interrelationships are slightly weaker. The specific mechanism providing this synchronization between heartbeat oscillations of mother and fetus is unclear. There are two hypothetic possibilities: an oscillation driver close in parameters for mother and fetus, and the maternal rhythm directly affecting the fetus.


Assuntos
Frequência Cardíaca , Relações Materno-Fetais , Atividade Motora , Animais , Feminino , Coração Fetal/embriologia , Coração Fetal/fisiologia , Gravidez , Ratos , Respiração
10.
Z Geburtshilfe Neonatol ; 218(2): 56-63, 2014 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-24788834

RESUMO

Numerous maternal (diabetes, preeclampsia) and fetal pathologies (uteroplacental dysfunction, hydrops, infection, congenital heart disease) can lead to cardiac dysfunction in the fetus. This includes increase of pre- and afterload, compression of the heart, myocardial damage, hypoxia and hyperglycemia. Beside already established methods like m-mode and pulse-waved Doppler, new promising technologies like tissue Doppler and speckle tracking are available for monitoring fetal cardiac function. Some of these new techniques have not been part of clinical routine yet because no validation has been performed so far and/or the technique is too time-consuming. Other technologies are currently being tested and only part of research projects. Innovations like speckle tracking that have its seeds in adult cardiology, are still limited because of the smallness of the fetal heart, the higher heart rate, fetal and maternal moving artefacts and finally because of a missing fetal ECG signal. Therefore their application should be performed critically.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Coração Fetal/diagnóstico por imagem , Cardiopatias/diagnóstico , Cardiopatias/embriologia , Testes de Função Cardíaca/métodos , Aumento da Imagem/métodos , Ultrassonografia Pré-Natal/métodos , Coração Fetal/embriologia , Humanos
11.
Ultrasound Obstet Gynecol ; 37(4): 404-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20886509

RESUMO

OBJECTIVES: Our objectives were to compare the size and volume of the developing fetal thymus obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US), develop normative data for thymus volume (TV), and investigate TV in fetuses with congenital heart disease (CHD) and normal twin gestations. METHODS: We studied 321 fetuses (gestational age (GA): 17-39 weeks) including 238 normal singletons, 64 normal twins and 19 singleton fetuses with CHD. We used 2D-US to assess fetal thymus maximum transverse diameter (MTD), maximum transverse area (MTA), anteroposterior diameter (APD) and superoinferior diameter (SID). TV was obtained by 3D-US using virtual organ computer-aided analysis. Measurements were adjusted for estimated fetal weight where appropriate. Linear regression analysis, general linear models and Fisher's Z-transformation were used where appropriate. A nomogram of fetal TV based on singleton gestations was produced according to previously published methods. RESULTS: Ultrasound assessment of the fetal thymus was possible in 95.3% (306/321) of cases. Both 3D-US and 2D-US measurements were significantly correlated with GA (TV r = 0.989; MTA r = 0.918; MTD r = 0.884; APD r = 0.849; and SID r = 0.816; all P < 0.05). After Fisher's Z-transformation, the correlation between the TV and GA was significantly stronger than that between any individual 2D-US measurement and GA (P < 0.05). Normal twin fetuses had TVs similar to those of singletons adjusted for estimated fetal weight and GA (P = 0.85). TV adjusted for estimated fetal weight and GA was significantly lower in fetuses with CHD than in normal singletons (P < 0.05). CONCLUSION: 2D-US and 3D-US are useful tools for evaluation of the size and volume of the human fetal thymus through gestation. Fetal TV by 3D-US seems to reflect normal development of the thymus in utero better than do 2D-US measurements. Lower TV should be expected in association with CHDs.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Timo/diagnóstico por imagem , Doenças em Gêmeos/diagnóstico por imagem , Doenças em Gêmeos/patologia , Ecocardiografia Tridimensional , Feminino , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Idade Gestacional , Cardiopatias Congênitas/patologia , Humanos , Imageamento Tridimensional/métodos , Tamanho do Órgão , Gravidez , Timo/embriologia , Ultrassonografia Pré-Natal
12.
Can J Physiol Pharmacol ; 87(9): 736-42, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19794525

RESUMO

Assessment of baroreceptor reflex sensitivity (BRS) in the ovine fetus provides insight into autonomic cardiovascular regulation. Currently, assessment of BRS relies on vasoactive drugs, but this approach is limited by feasibility issues and by the nonphysiologic nature of the stimulus. Thus we aimed to validate the method of spontaneous BRS assessment against the reference method of using vasoactive drugs in preterm (0.76 gestation, n = 16) and near-term (0.86 gestation, n = 16) chronically instrumented ovine fetuses. The BRS measures derived from the spontaneous and reference methods correlated at both gestational ages (R = 0.67 +/- 0.03). The sequence method of spontaneous BRS measures also correlated both to the root mean square of standard deviations (RMSSD), which is a measure of fetal heart rate variability reflecting vagal modulation (R = 0.69 +/- 0.03), and to fetal body weight (R = 0.65 +/- 0.03), which is a surrogate for growth trajectory of each fetus. The methodology presented may aid in developing new models to study BRS and cardiovascular control in ovine fetus in the last trimester of pregnancy.


Assuntos
Barorreflexo/fisiologia , Coração Fetal/embriologia , Monitorização Fetal/métodos , Frequência Cardíaca Fetal/fisiologia , Ovinos/embriologia , Animais , Barorreflexo/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Feminino , Coração Fetal/efeitos dos fármacos , Coração Fetal/fisiologia , Idade Gestacional , Frequência Cardíaca Fetal/efeitos dos fármacos , Gravidez , Reprodutibilidade dos Testes , Ovinos/fisiologia , Vasoconstritores/farmacologia , Vasodilatadores/farmacologia
13.
Ultrasound Med Biol ; 34(5): 741-52, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18328616

RESUMO

To establish a developmental profile of fetal mouse cardiovascular parameters, we analyzed a large body of ultrasound measurements obtained by in utero echocardiography of C57BL/6J fetal mice from embryonic day 12.5 to 19.5 (term). Measurements were obtained using two-dimensional (2D), spectral Doppler and M-mode imaging with standard clinical cardiac ultrasound imaging planes. As these studies were conducted as part of a large scale mouse mutagenesis screen, stringent filtering criteria were used to eliminate potentially abnormal fetuses. Our analysis showed heart rate increased from 190 to 245 beats per minute as the mouse fetus grew from 8 mm at embryonic day 12.5 to 18.7 mm at term. This was accompanied by increases in peak outflow velocity, E-wave, E/A ratio and ventricular dimensions. In contrast, the A-wave, myocardial performance index and isovolemic contraction time decreased gradually. Systolic function remained remarkably stable at 80% ejection fraction. Analysis of intra- and interobserver variabilities showed these parameters were reproducible, with most comparing favorably to clinical ultrasound measurements in human fetuses. A comprehensive database was generated comprising 23 echocardiographic parameters delineating fetal mouse cardiovascular function from embryonic day 12.5 to term. This database can serve as a standard for evaluating cardiovascular pathophysiology in genetically altered and mutant mouse models.


Assuntos
Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Animais , Ecocardiografia Doppler , Feminino , Coração Fetal/embriologia , Idade Gestacional , Frequência Cardíaca Fetal , Camundongos , Camundongos Endogâmicos C57BL , Modelos Animais , Gravidez , Fluxo Sanguíneo Regional , Processamento de Sinais Assistido por Computador , Volume Sistólico , Sístole
14.
Basic Res Cardiol ; 96(3): 251-7, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11403418

RESUMO

BACKGROUND: Fetal tachyarrhythmias are usually of supraventricular origin. To investigate whether specific electrophysiologic properties of the fetal heart contribute to this preponderance by either favoring supraventricular tachycardias or by rendering ventricular tachycardias unlikely, we measured fetal electrophysiologic parameters in utero using transuterine fetal transesophageal electrocardiograms in fetal sheep. Since overdrive pacing may help to establish the mechanism of an arrhythmia and may be used to treat fetal tachycardias, different modes of transesophageal pacing in utero were also assessed. METHODS AND RESULTS: Decapolar electrophysiology catheters were fetoscopically inserted into the esophagus of 9 fetal sheep (pregnancy duration 94- 105 days, term = 145 days). Electrocardiograms were recorded simultaneously from all adjacent bipoles and from two pacing wires sutured onto the fetal shoulders. Pacing was attempted either via two adjacent electrodes of the intraesophageal catheter or via the most distal and most proximal electrode. Fetal cycle length, PQ, and QT intervals were close to (approx. 75 %), but fetal QRS duration was < 20 % of maternal values, thus shifting the relation between activation and repolarization towards longer excitation wave lengths. Fetal QT dispersion was small (< or = 10 ms). Atrial pacing was achieved in all fetuses using distant electrodes, and with lower thresholds when compared to closely spaced bipolar electrodes (p < 0.05). CONCLUSIONS: (I) An altered relation between ventricular activation and repolarization and a low dispersion of ventricular repolarization may protect the fetal heart against ventricular reentrant tachycardias. (II) Relatively normal fetal AV nodal conduction delay already provides one of the prerequisites for supraventricular reentrant tachycardias involving the AV node at this stage of fetal development. (III) High-rate esophageal pacing of the fetal atria is best achieved using widely spaced bipolar pacing electrodes.


Assuntos
Nó Atrioventricular/embriologia , Eletrofisiologia , Coração Fetal/embriologia , Ventrículos do Coração/embriologia , Útero/embriologia , Animais , Sistema Cardiovascular/embriologia , Eletrocardiografia , Desenvolvimento Embrionário e Fetal/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Modelos Animais , Modelos Cardiovasculares , Gravidez , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA