Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 448
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Hazard Mater ; 474: 134697, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38823102

RESUMO

Airborne pathogens severely threaten public health worldwide. Air disinfection is essential to ensure public health. However, excessive use of disinfectants may endanger environmental and ecological security due to the residual disinfectants and their by-products. This study systematically evaluated disinfection efficiency, induction of multidrug resistance, and the underlying mechanisms of disinfectants (NaClO and H2O2) on airborne bacteria. The results showed that airborne bacteria were effectively inactivated by atomized NaClO (>160 µg/L) and H2O2 (>320 µg/L) after 15 min. However, some bacteria still survived after disinfection by atomized NaClO (0-80 µg/L) and H2O2 (0-160 µg/L), and they exhibited significant increases in antibiotic resistance. The whole-genome sequencing of the resistant bacteria revealed distinct mutations that were responsible for both antibiotic resistance and virulence. This study also provided evidences and insights into possible mechanisms underlying the induction of antibiotic resistance by air disinfection, which involved intracellular reactive oxygen species formation, oxidative stress responses, alterations in bacterial membranes, activation of efflux pumps, and the thickening of biofilms. The present results also shed light on the role of air disinfection in inducing antibiotic resistance, which could be a crucial factor contributing to the global spread of antibiotic resistance through the air.


Assuntos
Bactérias , Desinfetantes , Desinfecção , Peróxido de Hidrogênio , Peróxido de Hidrogênio/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Bactérias/efeitos dos fármacos , Bactérias/genética , Microbiologia do Ar , Biofilmes/efeitos dos fármacos , Hipoclorito de Sódio/farmacologia , Farmacorresistência Bacteriana/genética , Farmacorresistência Bacteriana/efeitos dos fármacos , Antibacterianos/farmacologia , Cloro/farmacologia , Espécies Reativas de Oxigênio/metabolismo
2.
Sci Total Environ ; 941: 173710, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38830423

RESUMO

Legionella is an opportunistic waterborne pathogen that is difficult to eradicate in colonized drinking water pipes. Legionella control is further challenged by aging water infrastructure and lack of evidence-based guidance for building treatment. This study assessed multiple premise water remediation approaches designed to reduce Legionella pneumophila within a residential building located in an aging, urban drinking water system over a two-year period. Samples (n = 745) were collected from hot and cold-water lines and quantified via most probable number culture. Building-level treatment approaches included three single heat shocks, three single chemical shocks, and continuous low-level chemical disinfection in the potable water system. The building was highly colonized with L. pneumophila with 71 % L. pneumophila positivity. Single heat shocks had a statistically significant L. pneumophila reduction one day post treatment but no significant L. pneumophila reduction at one week, two weeks, and four weeks post treatment. The first two chemical shocks resulted in statistically significant L. pneumophila reduction at two days and four weeks post treatment, but there was a significant L. pneumophila increase at four weeks following the third chemical shock. Continuous low-level chemical disinfection resulted in statistically significant L. pneumophila reduction at ten weeks post treatment implementation. This demonstrates that in a building highly colonized with L. pneumophila, sustained remediation is best achieved using continuous low-level chemical treatment.


Assuntos
Água Potável , Microbiologia da Água , Purificação da Água , Água Potável/microbiologia , Purificação da Água/métodos , Desinfecção/métodos , Legionella pneumophila , Abastecimento de Água , Legionella , Recuperação e Remediação Ambiental/métodos
3.
J Environ Manage ; 364: 121442, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38870793

RESUMO

The widespread use of low or medium pressure mercury lamps in UV-C water disinfection should consider recent advances in UV-C LED lamps that offer a more sustainable approach and avoid its main drawbacks. The type of water and the mode of operation are critical when deciding on the treatment technology to be used. Therefore, this study investigates the potential application of UV-C LED disinfection technology in terms of kinetics, environmental assessment, and economic analysis for two scenarios: the continuous disinfection of a wastewater treatment plant (WWTP), and disinfection of harvested rainwater (RWH) in a residential household that operates intermittently. Experiments are conducted using both the new UV-C LED system and the conventional mercury lamp to disinfect real wastewater. Removal of total coliforms and Escherichia coli bacteria, with concentrations of approximately 105 and 104 CFU per 100 mL has been followed to assess the performance of both types of UV-C lamps. The experimental study provides kinetic parameters that have been further used in the environmental assessment conducted from a life cycle perspective. Additionally, considering the significant role of electricity consumption, a preliminary economic analysis has been conducted. The results indicate that first-order kinetic constants of pathogens removal with UV-C LEDs achieve 1.4 times higher values than Hg lamp. Regarding the environmental and economic assessment, for disinfection systems operating continuously, LEDs result in environmental impacts 5 times higher than Hg lamp in most categories, indicating that Hg lamps offer a viable option both from economic and environmental point of view. However, for installations with intermittent operation, LEDs emerge as the most competitive alternative, due to their ability to be turned on and off without affecting their lifespan. This study shows that UV-C LED lamps hold promise to replace conventional mercury lamps in a near future.


Assuntos
Desinfecção , Raios Ultravioleta , Purificação da Água , Desinfecção/métodos , Purificação da Água/métodos , Purificação da Água/economia , Escherichia coli/efeitos da radiação , Águas Residuárias
4.
J Hazard Mater ; 474: 134751, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38820748

RESUMO

Chlorination on microplastic (MP) biofilms was comprehensively investigated with respect to disinfection efficiency, morphology, and core microbiome. The experiments were performed under various conditions: i) MP particles; polypropylene (PP) and polystyrene (PS), ii) MP biofilms; Escherichia coli for single-species and river water microorganisms for multiple-species, iii) different chlorine concentrations, and iv) different chlorine exposure periods. As a result, chlorination effectively inactivated the MP biofilm microorganisms. The disinfection efficiency increased with increasing the free chlorination concentration and exposure periods for both single- and multiple-species MP biofilms. The multiple-species MP biofilms were inactivated 1.3-6.0 times less than single-species MP biofilms. In addition, the PP-MP biofilms were more vulnerable to chlorination than the PS-MP biofilms. Morphology analysis verified that chlorination detached most MP biofilms, while a small part still remained. Interestingly, chlorination strongly changed the biofilm microbiome on MPs; the relative abundance of some microbes increased after the chlorination, suggesting they could be regarded as chlorine-resistant bacteria. Some potential pathogens were also remained on the MP particles after the chlorination. Notably, chlorination was effective in inactivating the MP biofilms. Further research should be performed to evaluate the impacts of residual MP biofilms on the environment.


Assuntos
Biofilmes , Cloro , Desinfecção , Escherichia coli , Halogenação , Microplásticos , Biofilmes/efeitos dos fármacos , Desinfecção/métodos , Cloro/farmacologia , Cloro/química , Escherichia coli/efeitos dos fármacos , Microplásticos/toxicidade , Microbiologia da Água , Desinfetantes/farmacologia , Polipropilenos/química , Poliestirenos/química , Purificação da Água/métodos
5.
Environ Pollut ; 355: 124184, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38782162

RESUMO

While sodium hypochlorite (NaClO) has long been used to disinfect drinking water, concerns have risen over its use due to causing potentially hazardous byproducts. Catalytic ozonation with metal-free catalysts has attracted increasing attention to eliminate the risk of secondary pollution of byproducts in water treatment. Here, we compared the disinfection efficiency and microbial community of catalytic ozone with a type of metal-free catalyst fluorinated ceramic honeycomb (FCH) and NaClO disinfectants under laboratory- and pilot-scale conditions. Under laboratory conditions, the disinfection rate of catalytic ozonation was 3∼6-fold that of ozone when the concentration of Escherichia coli was 1 × 106 CFU/ml, and all E. coli were killed within 15 s. However, 0.65 mg/L NaClO retained E. coli after 30 min using the traditional culturable approach. The microorganism inactivation results of raw reservoir water disinfected by catalytic ozonation and ozonation within 15 s were incomparable based on the cultural method. In pilot-scale testing, catalytic ozonation inactivated all environmental bacteria within 4 min, while 0.65 mg/L NaClO could not achieve this success. Both catalytic ozonation and NaClO-disinfected methods significantly reduced the number of microorganisms but did not change the relative abundances of different species, i.e., bacteria, viruses, eukaryotes, and archaea, based on metagenomic analyses. The abundance of virulence factors (VFs) and antimicrobial resistance genes (ARGs) was detected few in catalytic ozonation, as determined by metagenomic sequencing. Some VFs or ARGs, such as virulence gene 'FAS-II' which was hosted by Mycobacterium_tuberculosis, were detected solely by the NaClO-disinfected method. The enriched genes and pathways of cataO3-disinfected methods exhibited an opposite trend, especially in human disease, compared with NaClO disinfection. These results indicated that the disinfection effect of catalytic ozone is superior to NaClO, this finding contributed to the large-scale application of catalytic ozonation with FCH in practical water treatment.


Assuntos
Cerâmica , Desinfetantes , Desinfecção , Água Potável , Ozônio , Hipoclorito de Sódio , Purificação da Água , Ozônio/química , Desinfetantes/farmacologia , Água Potável/microbiologia , Água Potável/química , Desinfecção/métodos , Cerâmica/química , Purificação da Água/métodos , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/química , Catálise , Halogenação , Escherichia coli/efeitos dos fármacos , Projetos Piloto , Microbiologia da Água , Bactérias/efeitos dos fármacos
6.
J Hosp Infect ; 145: 218-223, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38272125

RESUMO

BACKGROUND: Cold air plasma (CAP) can generate plasma-activated liquids (PALs) with high concentrations of reactive oxygen (ROS) and nitrogen species (RNS), e.g., nitrites, with antimicrobial properties. AIM: We investigated the concentrations of ROS and RNS in saline PAL. We assessed planktonic bacterial inactivation by PAL and the decontamination of contaminated cleaning cloths. METHODS: Phosphate-buffered saline (PBS) was treated with an air-driven CAP jet for 90 or 300 s to generate PAL. The ROS and RNS were measured using quantitative fluorescent (2,7-dichlorofluorescin diacetate) and colourimetric (Greiss) assays. Isolates of MRSA and Escherichia coli were incubated in PAL overnight and inactivation measured through colony forming unit (cfu) assays. Sections of cleaning cloths were incubated with MRSA and E. coli, and treated with PAL for 1 h. Bacterial inactivation was measured through resazurin reduction assays. RESULTS: Nitrites increased from 0.1 µM in untreated PBS to 49.1 µM and to 94.0 µM in 90- and 300-s CAP-treated PAL, respectively. ROS increased from 30 µM in untreated PBS to 75 µM and to 103 µM in 90- and 300-s CAP-treated PAL, respectively. 90-s PAL reduced MRSA and E. coli viability (P<0.05) and 300-s PAL resulted in more than a 7-log reduction of both. One-hour treatment of contaminated cleaning cloths in PAL resulted in a 55% and 73% reduction in viable MRSA and E. coli, respectively (P<0.05). CONCLUSION: Inactivation of planktonic bacteria correlated with ROS and RNS concentrations. PAL reduced bacteria contaminated cleaning cloths. PAL has potential as a hospital disinfectant, including cleaning cloths.


Assuntos
Desinfecção , Escherichia coli , Humanos , Desinfecção/métodos , Nitritos , Espécies Reativas de Oxigênio , Bactérias , Antibacterianos/farmacologia , Atenção à Saúde
7.
Sci Total Environ ; 912: 168803, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38000739

RESUMO

Far-ultraviolet C (far-UVC) light is an effective and safe disinfection method for bioaerosol control in occupied indoor environments. The installation location of a far-UVC lamp strongly influences the spatial distribution of far-UVC irradiance, and thus the effectiveness of bioaerosol disinfection. To assist the design process, this study developed a fast prediction approach based on the Markov chain model for optimizing the installation locations of far-UVC lamps in order to enhance the disinfection effectiveness for indoor bioaerosol control. Experiments were conducted in an environmental chamber to validate the proposed simulation-based optimization approach. The results show that the proposed method can correctly predict the disinfection efficiency when compared with experimental data, and optimizing the installation location of the far-UVC lamp increased the disinfection efficiency by 54 % compared with the worst location. As an application, the validated method was then used to design the installation location of a far-UVC lamp in a real conference room. The results show that installing the far-UVC lamp in the optimal location can increase the disinfection efficiency by 48 % compared with the worst installation location. Therefore, optimizing the far-UVC lamp location using the proposed Markov chain model can enhance the effectiveness of bioaerosol disinfection in indoor environments.


Assuntos
Desinfecção , Raios Ultravioleta , Desinfecção/métodos , Cadeias de Markov
8.
J Expo Sci Environ Epidemiol ; 34(2): 345-355, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145997

RESUMO

BACKGROUND: For healthcare workers, surface disinfections are daily routine tasks. An assessment of the inhalation exposure to hazardous substances, in this case the disinfectant´s active ingredients, is necessary to ensure workers safety. However, deciding which exposure model is best for exposure assessment remains difficult. OBJECTIVE: The aim of the study was to evaluate the applicability of different exposure models for disinfection of small surfaces in healthcare settings. METHODS: Measurements of the air concentration of active ingredients in disinfectants (ethanol, formaldehyde, glutaraldehyde, hydrogen peroxide, peroxyacetic acid) together with other exposure parameters were recorded in a test chamber. The measurements were performed using personal and stationary air sampling. In addition, exposure modelling was performed using three deterministic models (unsteady 1-zone, ConsExpo and 2-component) and one modifying-factor model (Stoffenmanager®). Their estimates were compared with the measured values using various methods to assess model quality (like accuracy and level of conservatism). RESULTS: The deterministic models showed overestimation predominantly in the range of two- to fivefold relative to the measured data and high conservatism for all active ingredients of disinfectants with the exception of ethanol. With Stoffenmanager® an exposure distribution was estimated for ethanol, which was in good accordance with the measured data. IMPACT STATEMENT: To date, workplace exposure assessments often involve expensive and time consuming air measurements. Reliable exposure models can be used to assess occupational inhalation exposure to hazardous substances, in this case surface disinfectants. This study describes the applicability of three deterministic and one modifying-factor model for disinfection of small surfaces in healthcare settings, in direct comparison to measurements performed and will facilitate future exposure assessments at these workplaces.


Assuntos
Desinfetantes , Desinfecção , Exposição por Inalação , Exposição Ocupacional , Exposição Ocupacional/análise , Humanos , Exposição por Inalação/análise , Desinfetantes/análise , Desinfecção/métodos , Modelos Teóricos , Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos
9.
J Microbiol Immunol Infect ; 57(2): 211-224, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38135645

RESUMO

Reprocessing of gastrointestinal (GI) endoscopes and accessories is an essential part of patient safety and quality control in GI endoscopy centers. However, current endoscopic reprocessing guidelines or procedures are not adequate to ensure patient-safe endoscopy. Approximately 5.4 % of the clinically used duodenoscopes remain contaminated with high-concern microorganisms. Thus, the Digestive Endoscopy Society of Taiwan (DEST) sets standards for the reprocessing of GI endoscopes and accessories in endoscopy centers. DEST organized a task force working group using the guideline-revision process. These guidelines contain principles and instructions of step-by-step for endoscope reprocessing. The updated guidelines were established after a thorough review of the existing global and local guidelines, systematic reviews, and health technology assessments of clinical effectiveness. This guideline aims to provide detailed recommendations for endoscope reprocessing to ensure adequate quality control in endoscopy centers.


Assuntos
Desinfecção , Contaminação de Equipamentos , Humanos , Desinfecção/métodos , Taiwan , Endoscópios , Endoscópios Gastrointestinais
10.
Environ Sci Technol ; 57(44): 16823-16833, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37874250

RESUMO

Haloacetaldehydes (HALs) represent the third-largest category of disinfection byproducts (DBPs) in drinking water in terms of weight. As a subset of unregulated DBPs, only a few HALs have undergone assessment, yielding limited information regarding their genotoxicity mechanisms. Herein, we developed a simplified yeast-based toxicogenomics assay to evaluate the genotoxicity of five specific HALs. This assay recorded the protein expression profiles of eight Saccharomyces cerevisiae strains fused with green fluorescent protein, including all known DNA damage and repair pathways. High-resolution real-time pathway activation data and protein expression profiles in conjunction with clustering analysis revealed that the five HALs induced various DNA damage and repair pathways. Among these, chloroacetaldehyde and trichloroacetaldehyde were found to be positively associated with genotoxicity, while dichloroacetaldehyde, bromoacetaldehyde, and tribromoacetaldehyde displayed negative associations. The protein effect level index, which are molecular end points derived from a toxicogenomics assay, exhibited a statistically significant positive correlation with the results of traditional genotoxicity assays, such as the comet assay (rp = 0.830 and p < 0.001) and SOS/umu assay (rp = 0.786 and p = 0.004). This yeast-based toxicogenomics assay, which employs a minimal set of gene biomarkers, can be used for mechanistic genotoxicity screening and assessment of HALs and other chemical compounds. These results contribute to bridging the knowledge gap regarding the molecular mechanisms underlying the genotoxicity of HALs and enable the categorization of HALs based on their distinct DNA damage and repair mechanisms.


Assuntos
Desinfetantes , Poluentes Químicos da Água , Purificação da Água , Desinfecção/métodos , Saccharomyces cerevisiae/genética , Toxicogenética/métodos , Purificação da Água/métodos , Dano ao DNA , Poluentes Químicos da Água/análise , Desinfetantes/análise , Desinfetantes/química
11.
Ecotoxicol Environ Saf ; 261: 115107, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37290298

RESUMO

Under the influence of different types of disinfectants and disinfection environments, the removal level of pathogens and the formation potential of disinfection by-products (DBPs) will have a dual impact on the groundwater environment. The key points for sustainable groundwater safety management are how to balance the positive and negative relationship and formulate a scientific disinfection model in combination with risk assessment. In this study, the effects of sodium hypochlorite (NaClO) and peracetic acid (PAA) concentrations on pathogenic E. coli and DBPs were investigated using static-batch and dynamic-column experiments, as well as the optimal disinfection model for groundwater risk assessment was explored using quantitative microbial risk assessment and disability-adjusted life years (DALYs) models. Compared to static disinfection, deposition and adsorption were the dominant factors causing E. coli migration at lower NaClO levels of 0-0.25 mg/L under dynamic state, while disinfection was its migration factor at higher NaClO levels of 0.5-6.5 mg/L. In contrast, E. coli removed by PAA was the result of the combined action of deposition, adsorption, and disinfection. The disinfection effects of NaClO and PAA on E. coli differed under dynamic and static conditions. At the same NaClO level, the health risk associated with E. coli in groundwater was higher, whereas, under the same PAA conditions, the health risk was lower. Under dynamic conditions, the optimal disinfectant dosage required for NaClO and PAA to reach the same acceptable risk level was 2 and 0.85 times (irrigation) or 0.92 times (drinking) of static disinfection, respectively. The results may help prevent the misuse of disinfectants and provide theoretical support for managing twin health risks posed by pathogens and DBPs in water treatment.


Assuntos
Desinfetantes , Água Subterrânea , Purificação da Água , Desinfecção/métodos , Escherichia coli , Desinfetantes/farmacologia , Ácido Peracético , Purificação da Água/métodos , Medição de Risco
12.
J Fluoresc ; 33(6): 2339-2347, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37043059

RESUMO

In this article, Fluorescence spectroscopy has been employed for the assessment of microbial load and it has been compared with the gold standard colony forming unit (CFU) and optical density (OD) methods. In order to develop a correlation between three characterization techniques, water samples of different microbial loads have been prepared by UVC disinfection method through an indigenously developed NUVWater sterilizer, which operates in close cycle flow configuration. A UV dose of 58.9 mJ/cm2 has been determined for 99.99% disinfection for a flow rate of 0.8 l/min. The water samples were excited at 270 nm which results in the tryptophan like fluorescence at 360 nm that decreases gradually with increase of UVC dose, indicating the bacterial degradation and it has been confirmed by OD and CFU methods. In addition, it has been proved that a close cycle water flow around UV lamp is imperative so that an appropriate dose must be delivered to microorganisms for an efficient disinfection. It has been found that due to the sensitive nature of Fluorescence spectroscopy, it yields immediate results, whereas, for CFU and OD methods, water samples needs to be inoculated for 24 h. Fluorescence spectroscopy, therefore, provide a fast, online, reliable and sensitive method for the monitoring of pathogenic quantification in drinking water.


Assuntos
Água Potável , Raios Ultravioleta , Espectrometria de Fluorescência , Bactérias , Desinfecção/métodos
13.
Chemosphere ; 329: 138696, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37062392

RESUMO

The formation characteristics of trihalomethanes (THMs) and haloacetamides (HAcAms) from dissolved organic matter and its fractions were investigated during chlorine-based disinfection processes. The relationships between water quality parameters, fluorescence parameters, and the formation levels of THMs and HAcAms were analyzed. The fractions contributing most to the acute toxicity were identified. The trichloromethane (TCM) generation level (72 h) generally followed the order of Cl2 > NH2Cl > NHCl2 process. The NHCl2 process was superior to the NH2Cl process in controlling TCM formation. Hydrophobic acidic substance (HOA), hydrophobic neutral substance (HON), and hydrophilic substance (HIS) were identified as primary precursors of 2,2-dichloroacetamide and trichloroacetamide during chlorination and chloramination. The formation of TCM mainly resulted from HOA, HON and HIS fractions relatively uniformly, while HOA and HIS fractions contributed more to the formation of bromodichloromethane and dibromomonochloromethane. UV254 could be used as an alternative indicator for the amount of ΣTHMs formed during chlorination and chloramination processes. Dissolved organic nitrogen was a potential precursor of 2,2-dichloroacetamide during chlorination process. The fractions with the highest potential acute toxicity after the chlorination were water-dependent.


Assuntos
Desinfetantes , Poluentes Químicos da Água , Purificação da Água , Desinfetantes/toxicidade , Desinfetantes/química , Cloraminas/química , Halogenação , Purificação da Água/métodos , Desinfecção/métodos , Trialometanos/toxicidade , Trialometanos/química , Cloro/química , Clorofórmio , Poluentes Químicos da Água/análise
14.
PLoS One ; 18(3): e0283699, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36996059

RESUMO

The disinfection of commercial hatching eggs before incubation is a common strategy to reduce potential vertical transmission of bacterial and fungal infections from the eggshell to one-day-old chicks that may prevail in poultry products and eventually reach the end consumer. The present investigation focuses on the parallel testing and application of four different disinfection methods (conventional and alternative) under commercial hatchery conditions against natural eggshell bacterial contamination. Hatching eggs from two ROSS 308 broiler breeder flocks were selected and divided into six different groups: two groups were not disinfected and served as negative controls, and four were independently disinfected following product specifications and protocols. From each group, a sample of 100 hatching eggs was selected for bacterial re-isolation, utilizing a modified shell rinse method. Colony-forming units (cfu) from the shell rinse suspensions were determined and analyzed to establish cfu values for each tested egg. These values were analyzed to determine the bacterial disinfection capacity of the four disinfection methods under commercial hatchery conditions. The tested methods were hydrogen peroxide + alcohol, peracetic acid, low energy electron beam, and the gold standard in practice: formaldehyde. Among these methods, formaldehyde, peracetic acid, and low energy electron beam showed a significant difference when compared to the non-disinfected groups whereas hydrogen peroxide + alcohol did not. The bacterial disinfection capacity of the tested methods was compared as well to the gold standard method formaldehyde fumigation and only low energy electron beam achieved similar disinfection levels as formaldehyde. According to our data, three methods significantly reduce the bacterial load on the eggshell of hatching eggs under commercial hatching conditions, including potential alternative methods such as low energy electron beam that perform similar to the gold standard in practice.


Assuntos
Desinfecção , Ácido Peracético , Animais , Desinfecção/métodos , Galinhas/microbiologia , Peróxido de Hidrogênio/farmacologia , Formaldeído , Óvulo
15.
Sensors (Basel) ; 23(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36679380

RESUMO

The lack of safe drinking water is one of the main health problems in many regions of the world. In order to face it, Solar water disinfection (SODIS) proposes the use of transparent plastic containers, which are filled with contaminated water, and exposed to direct sunlight until enough UV radiation is received to inactivate the pathogens. However, a reliable method for determining the end of the disinfection process is needed. Although several approaches have been proposed in the literature for this purpose, they do not strictly accomplish two critical constraints that are essential in this type of project, namely, low cost and sustainability. In this paper, we propose an electronic device to determine when the lethal UV dose has been reached in SODIS containers, which accomplishes both constraints mentioned above: on the one hand, its manufacturing cost is around EUR 12, which is much lower than the price of other electronic solutions; on the other hand, the device is sufficiently autonomous to work for months with small low-cost disposable batteries, thereby avoiding the use of rechargeable batteries, which are considered hazardous waste at the end of their useful life. In our approach, we first analyze different low cost UV sensors in order to select the most accurate one by comparing their response with a reference pattern provided by a radiometer. Then, an electronic device is designed using this sensor, which measures the accumulated UV radiation and compares this value with the lethal UV dose to determine the end of the disinfection process. Finally, the device has been manufactured and tested in real conditions to analyze its accuracy, obtaining satisfactory results.


Assuntos
Água Potável , Purificação da Água , Luz Solar , Purificação da Água/métodos , Desinfecção/métodos , Abastecimento de Água , Microbiologia da Água
16.
Sci Total Environ ; 869: 161848, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36709900

RESUMO

The COVID-19 pandemic has promoted interest in using devices emitting ultraviolet-C (UVC) irradiation (200-280 nm) for surface disinfection to reduce pathogen transmission, especially in occupied public spaces. While UVC devices have been shown to be highly effective against various pathogens, there are safety concerns when using conventional UVC devices for surface disinfection, including human exposure of reflected UVC irradiation and ozone generation. Emerging Far UVC devices (emitting at 200-230 nm), like the krypton chloride (KrCl*) excimer, have the potential to be safely applied in occupied spaces due to their minimal adverse effects on skin and eyes. In this study, UV reflection of 21 common materials was documented and compared using a filtered KrCl* excimer (installed with a bandpass filter at 222 nm), an unfiltered KrCl* excimer, and a conventional low-pressure mercury vapor lamp. The safety of Far UVC devices was evaluated based on the irradiance and spectrum of reflected UV irradiation and ozone generation measured at various locations around the device. Our results show that most common materials can reflect UV irradiation, among which some metals tend to have greater reflection. The Far UVC devices, especially the filtered KrCl* excimer, should be safe to be applied in occupied spaces for effective surface disinfection, with limited ozone generation and no health risk from reflected UV irradiation. However more caution is needed when using unfiltered KrCl* devices and conventional UV 254 nm light. This study provides urgently needed data on UV reflection of common materials and guidance for safety assessments of UVC devices for surface disinfection in occupied spaces.


Assuntos
COVID-19 , Desinfecção , Humanos , Desinfecção/métodos , Pandemias , Raios Ultravioleta , Pele
17.
Environ Sci Pollut Res Int ; 30(7): 18354-18363, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36210406

RESUMO

Trihalomethanes (THMs) are the most common species of disinfection by-products (DBPs) in swimming pools and have received widespread attention due to their risk to public health. However, studies examining within-day variation and the carcinogenic health risks from exposure to THMs in indoor swimming pools are limited. Our study aimed to detect the within-day variation of four THMs categories and carcinogenic health risk in indoor swimming pool water in Taiyuan, China, and to examine the correlations between THMs and environmental parameters. Our results showed chloroform (TCM) was the most abundant component in THMs with median concentrations from 0.038-0.118 µg/m3. TCM and THMs were significantly positively correlated with FCl and significantly negatively correlated with the cumulative number of swimmers (CNS) in the swimming pool. The concentration of total THMs and TCM, lifetime average daily doses (LADD) of TCM, and the total lifetime cancer risks (ELCR) values of THMs declined with time with the highest level occurring at 8:00 am. ELCR values of THMs were in the range of 1.368 × 10-5-1.968 × 10-5, which exceeded the negligible risk level (10-6) defined by US EPA. Our results suggest that THM occurrence and the carcinogenic health risks in pool water varied temporally. Exposure to pool water THMs may pose a carcinogenic risk to human health, especially at the pool's opening time.


Assuntos
Desinfetantes , Piscinas , Poluentes Químicos da Água , Humanos , Trialometanos/análise , Poluentes Químicos da Água/análise , Desinfecção/métodos , Água , Medição de Risco , Carcinogênese , Carcinógenos , China , Desinfetantes/análise
18.
Environ Toxicol Pharmacol ; 97: 104026, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36455839

RESUMO

It is important to study the stress effects and mechanisms of haloacetamide (HAcAm) disinfection byproducts to reveal their health hazards. In this context, toxicological g was applied to evaluate the effects of four HAcAms, revealing the status of gene expression on Escherichia coli in different stress response types (oxidative, protein, membrane, general, DNA). This study revealed that the main toxic action modes of these HAcAms were general and membrane stresses by high-resolution, real-time gene expression profiling combined with clustering analysis. The results of time-gene evaluation showed that the presence of chloroacetamide (CAcAm) and bromoacetamide (BAcAm) generated more reactive oxygen species, thus activating oxidative stress. Trichloroacetamide (tCAcAm) induced altered expression of glutathione marker genes and membrane stress-related genes, and iodoacetamide (IAcAm) caused severe DNA damage by damaging DNA strands and individual nucleotides mainly through damage to nucleic acids and bases. Furthermore, quantitative structure-activity relationship (QSAR) modelling results indicated that the biological activities of HAcAms were related to their quantum chemical and topological properties.


Assuntos
Toxicogenética , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Desinfecção/métodos , Estresse Oxidativo , Espécies Reativas de Oxigênio
19.
J Med Internet Res ; 24(12): e42332, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36269222

RESUMO

BACKGROUND: Virtual reality (VR) devices are increasingly used in health care settings. The use among patients has the potential to unintentionally transmit pathogens between patients and hospital staff. No standard operating procedure for disinfection exists to ensure safe use between patients. OBJECTIVE: This study aims to determine the efficacy of disinfectants on VR devices in order to ensure safe use in health care settings. METHODS: Three types of bacteria were inoculated onto porous and nonporous surfaces of 2 VR devices: the Meta Oculus Quest and Meta Oculus Quest 2. Disinfection was performed using either isopropyl alcohol or alcohol-free quaternary ammonium wipes. A quantitative culture was used to assess the adequacy of disinfection. A survey was separately sent out to VR device technicians at other pediatric health care institutes to compare the methods of disinfection and how they were established. RESULTS: Both products achieved adequate disinfection of the treated surfaces; however, a greater log-kill was achieved on nonporous surfaces than on the porous surfaces. Alcohol performed better than quaternary ammonium on porous surfaces. The survey respondents reported a wide variability in disinfection processes with only 1 person reporting an established standard operating procedure. CONCLUSIONS: Disinfection can be achieved through the use of either isopropyl alcohol or quaternary ammonium products. Porous surfaces showed lesser log-kill rates than the nonporous surfaces, indicating that the use of an added barrier may be of benefit and should be a point of future research. Given the variability in the disinfection process across health care systems, a standard operating procedure is proposed.


Assuntos
Compostos de Amônio , Realidade Virtual , Criança , Humanos , Desinfecção/métodos , 2-Propanol , Etanol , Inquéritos e Questionários , Atenção à Saúde
20.
Environ Sci Technol ; 56(22): 16336-16346, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36215720

RESUMO

Access to safe, sufficient water for health and sanitation is a human right, and the reliable disinfection of water plays a critical role in addressing this need. The environmental impact and sustainability of water disinfection methods will also play a role in overall public health. This study presents an investigation of the environmental life cycle impacts of four ultraviolet disinfection systems utilizing ambient solar radiation directly and indirectly for water disinfection in comparison to chlorination and water delivery for application in low-income settings. Product inspection and existing literature were used to define a life cycle functional unit of 1 m3 of water for each system, which allowed quantification of material use, infrastructure requirements, and life cycle of the original components of each system and those needed to keep them operational for the studied lifespans (1, 5, 10, and 20 years) and scales (30, 100, 500, and 1000 L per day). For all studied cases, chlorine had the lowest impact in all impact categories, but end-user acceptance of chlorine in some settings is low, driving interest in low-impact alternatives. Disinfection based on low-pressure mercury lamps had the next lowest normalized impact in most categories and may represent a viable alternative, particularly for long-term (10+ years), high production (500+ liters per day) scenarios.


Assuntos
Água Potável , Purificação da Água , Humanos , Animais , Desinfecção/métodos , Cloro/química , Purificação da Água/métodos , Raios Ultravioleta , Estágios do Ciclo de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA