Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Hazard Mater ; 472: 134458, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38703679

RESUMO

Diclofenac (DCF) is an environmentally persistent, nonsteroidal anti-inflammatory drug (NSAID) with thyroid disrupting properties. Electrochemical advanced oxidation processes (eAOPs) can efficiently remove NSAIDs from wastewater. However, eAOPs can generate transformation products (TPs) with unknown chemical and biological characteristics. In this study, DCF was electrochemically degraded using a boron-doped diamond anode. Ultra-high performance liquid chromatography coupled with high-resolution mass spectrometry was used to analyze the TPs of DCF and elucidate its potential degradation pathways. The biological impact of DCF and its TPs was evaluated using the Xenopus Eleutheroembryo Thyroid Assay, employing a transgenic amphibian model to assess thyroid axis activity. As DCF degradation progressed, in vivo thyroid activity transitioned from anti-thyroid in non-treated samples to pro-thyroid in intermediately treated samples, implying the emergence of thyroid-active TPs with distinct modes of action compared to DCF. Molecular docking analysis revealed that certain TPs bind to the thyroid receptor, potentially triggering thyroid hormone-like responses. Moreover, acute toxicity occurred in intermediately degraded samples, indicating the generation of TPs exhibiting higher toxicity than DCF. Both acute toxicity and thyroid effects were mitigated with a prolonged degradation time. This study highlights the importance of integrating in vivo bioassays in the environmental risk assessment of novel degradation processes.


Assuntos
Anti-Inflamatórios não Esteroides , Diclofenaco , Glândula Tireoide , Poluentes Químicos da Água , Animais , Diclofenaco/toxicidade , Diclofenaco/química , Diclofenaco/metabolismo , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/química , Glândula Tireoide/efeitos dos fármacos , Glândula Tireoide/metabolismo , Anti-Inflamatórios não Esteroides/toxicidade , Anti-Inflamatórios não Esteroides/química , Medição de Risco , Técnicas Eletroquímicas , Simulação de Acoplamento Molecular , Disruptores Endócrinos/toxicidade , Disruptores Endócrinos/química , Disruptores Endócrinos/metabolismo , Xenopus laevis , Diamante/química , Oxirredução , Boro/toxicidade , Boro/química
2.
Sensors (Basel) ; 24(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38676026

RESUMO

This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles. The X-ray detectors showed a linear response to radiation dose (r2 ≥ 0.9999). Overall, platinum and gold nanoparticles produced a dose enhancement in the medium (maximum of 1.9 and 3.1, respectively), while silver nanoparticles produced a shielding effect (maximum of 37%), lowering the dose in the medium. This work shows that the novel MEA can be a useful tool in the quantitative assessment of radiation dose enhancement due to nanoparticles. Together with its suitability for cells' exocytosis studies, it proves to be a highly versatile device for several applications.


Assuntos
Diamante , Eletrodos , Ouro , Nanopartículas Metálicas , Diamante/química , Nanopartículas Metálicas/química , Ouro/química , Prata/química , Platina/química , Doses de Radiação , Humanos , Raios X , Nanopartículas/química
3.
Med Phys ; 51(1): 533-544, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656015

RESUMO

BACKGROUND: Ion beam therapy allows for a substantial sparing of normal tissues and higher biological efficacy. Synthetic single crystal diamond is a very good material to produce high-spatial-resolution and highly radiation hard detectors for both dosimetry and microdosimetry in ion beam therapy. PURPOSE: The aim of this work is the design, fabrication and test of an integrated waterproof detector based on synthetic single crystal diamond able to simultaneously perform dosimetric and microdosimetric characterization of clinical ion beams. METHODS: The active elements of the integrated diamond device, that is, dosimeter and microdosimeter, were both realized in a Schottky diode configuration featured by different area, thickness, and shape by means of photolithography technologies for the selective growth of intrinsic and boron-doped CVD diamond. The cross-section of the sensitive volume of the dosimetric element is 4 mm2 and 1 µm-thick, while the microdosimetric one has an active cross-sectional area of 100 × 100 µm2 and a thickness of about 6.2 µm. The dosimetric and microdosimetric performance of the developed device was assessed at different depths in a water phantom at the MedAustron ion beam therapy facility using a monoenergetic uniformly scanned carbon ion beam of 284.7 MeV/u and proton beam of 148.7 MeV. The particle flux in the region of the microdosimeter was 6·107  cm2 /s for both irradiation fields. At each depth, dose and dose distributions in lineal energy were measured simultaneously and the dose mean lineal energy values were then calculated. Monte Carlo simulations were also carried out by using the GATE-Geant4 code to evaluate the relative dose, dose averaged linear energy transfer (LETd ), and microdosimetric spectra at various depths in water for the radiation fields used, by considering the contribution from the secondary particles generated in the ion interaction processes as well. RESULTS: Dosimetric and microdosimetric quantities were measured by the developed prototype with relatively low noise (∼2 keV/µm). A good agreement between the measured and simulated dose profiles was found, with discrepancies in the peak to plateau ratio of about 3% and 4% for proton and carbon ion beams respectively, showing a negligible LET dependence of the dosimetric element of the device. The microdosimetric spectra were validated with Monte Carlo simulations and a good agreement between the spectra shapes and positions was found. Dose mean lineal energy values were found to be in close agreement with those reported in the literature for clinical ion beams, showing a sharp increase along the Bragg curve, being also consistent with the calculated LETd for all depths within the experimental error of 10%. CONCLUSIONS: The experimental indicate that the proposed device can allow enhanced dosimetry in particle therapy centers, where the absorbed dose measurement is implemented by the microdosimetric characterization of the radiation field, thus providing complementary results. In addition, the proposed device allows for the reduction of the experimental uncertainties associated with detector positioning and could facilitate the partial overcoming of some drawbacks related to the low sensitivity of diamond microdosimeters to low LET radiation.


Assuntos
Diamante , Prótons , Diamante/química , Radiometria , Carbono/uso terapêutico , Íons , Método de Monte Carlo , Água
4.
Med Phys ; 51(2): 1450-1459, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37742343

RESUMO

BACKGROUND: The possible emergence of the FLASH effect-the sparing of normal tissue while maintaining tumor control-after irradiations at dose-rates exceeding several tens of Gy per second, has recently spurred a surge of studies attempting to characterize and rationalize the phenomenon. Investigating and reporting the dose and instantaneous dose-rate of ultra-high dose-rate (UHDR) particle radiotherapy beams is crucial for understanding and assessing the FLASH effect, towards pre-clinical application and quality assurance programs. PURPOSE: The purpose of the present work is to investigate a novel diamond-based detector system for dose and instantaneous dose-rate measurements in UHDR particle beams. METHODS: Two types of diamond detectors, a microDiamond (PTW 60019) and a diamond detector prototype specifically designed for operation in UHDR beams (flashDiamond), and two different readout electronic chains, were investigated for absorbed dose and instantaneous dose-rate measurements. The detectors were irradiated with a helium beam of 145.7 MeV/u under conventional and UHDR delivery. Dose-rate delivery records by the monitoring ionization chamber and diamond detectors were studied for single spot irradiations. Dose linearity at 5 cm depth and in-depth dose response from 2 to 16 cm were investigated for both measurement chains and both detectors in a water tank. Measurements with cylindrical and plane-parallel ionization chambers as well as Monte-Carlo simulations were performed for comparisons. RESULTS: Diamond detectors allowed for recording the temporal structure of the beam, in good agreement with the one obtained by the monitoring ionization chamber. A better time resolution of the order of few µs was observed as compared to the approximately 50 µs of the monitoring ionization chamber. Both diamonds detectors show an excellent linearity response in both delivery modalities. Dose values derived by integrating the measured instantaneous dose-rates are in very good agreement with the ones obtained by the standard electrometer readings. Bragg peak curves confirmed the consistency of the charge measurements by the two systems. CONCLUSIONS: The proposed novel dosimetric system allows for a detailed investigation of the temporal evolution of UHDR beams. As a result, reliable and accurate determinations of dose and instantaneous dose-rate are possible, both required for a comprehensive characterization of UHDR beams and relevant for FLASH effect assessment in clinical treatments.


Assuntos
Diamante , Hélio , Diamante/química , Hélio/uso terapêutico , Radiometria , Método de Monte Carlo
5.
Med Phys ; 47(2): 713-721, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31730226

RESUMO

PURPOSE: To investigate for the first time the potentialities of obtaining microdosimetric measurements in scanned clinical carbon-ion beams using synthetic single crystal diamond detector and to verify the spectral conversion methods. METHODS: Microdosimetric measurements were performed at different depths in a water phantom at the therapeutic scanned carbon-ion beam of the National Center of Oncological Hadrontherapy (CNAO) in Pavia, using waterproof encapsulated diamond microdosimeter developed at "Tor Vergata" University. A monoenergetic carbon-ion beam of 195 MeV/µ scanned over a square field of 2 × 2 cm2 was used. Experimental microdosimetric spectra were compared with those obtained with a propane-filled Tissue Equivalent Proportional Counters (TEPCs) microdosimeter in the same facility at the same conditions. To this purpose, the spectra in diamond were converted to the spectra that would have been collected with a propane-filled cylindrical sensitive volume by means of a novel analytic methodology, recently developed at MedAustron. RESULTS: The microdosimetric spectra acquired by the diamond microdosimeter show different shapes in the 10 keV µm-1  ÷ 103  keV µm-1 lineal-energy range at different water depths. In spite of the high counting rate, no spectral distortion, due to pile-up events and polarization effects, were observed. The experimental spectra have a low detection threshold of about 6 keV µm-1 due to the electronic noise in the irradiation room. The comparison between the spectra converted to propane from diamond detector and the spectra collected directly with propane-filled TEPC shows a good agreement in the whole lineal-energy range. Furthermore this comparison confirms that diamond detector response is LET independent. The frequency- and dose-mean lineal energy values were also assessed for all spectra. The frequency-mean values obtained with diamond microdosimeter at different depths scales rather well with the absorbed dose values. CONCLUSIONS: Microdosimetric characterization of a synthetic single crystal diamond detector in high-energy scanned carbon-ion beams was performed. The results of the present study showed that this detector is suitable for microdosimetry of clinical carbon ion beams. In addition, the good agreement between the converted diamond spectra and those obtained with TEPC provides the first experimental validation of the spectra conversion methodologies as valuable tools for the comparison of spectra collected with different detectors.


Assuntos
Diamante/química , Radiometria/instrumentação , Radiometria/métodos , Desenho de Equipamento , Íons , Transferência Linear de Energia , Modelos Lineares , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Reprodutibilidade dos Testes , Água
6.
ACS Appl Mater Interfaces ; 11(28): 25024-25033, 2019 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-31260250

RESUMO

Boron doped diamond (BDD), given the robustness of the material, is becoming an electrode of choice for applications which require long-term electrochemical monitoring of analytes in aqueous environments. However, despite the extensive work in this area, there are no studies which directly assess the biofilm formation (biofouling) capabilities of the material, which is an essential consideration because biofouling often causes deterioration in the sensor performance. Pseudomonas aeruginosa is one of the most prevalent bacterial pathogens linked to water-related diseases, with a strong capacity for forming biofilms on surfaces that are exposed to aquatic environments. In this study, we comparatively evaluate the biofouling capabilities of oxygen-terminated (O-)BDD against materials commonly employed as either the packaging or sensing element in water quality sensors, with an aim to identify factors which control biofilm formation on BDD. We assess the monospecies biofilm formation of P. aeruginosa in two different growth media, Luria-Bertani, a high nutrient source and drinking water, a low nutrient source, at two different temperatures (20 and 37 °C). Multispecies biofilm formation is also investigated. The performance of O-BDD, when tested against all other materials, promotes the lowest extent of P. aeruginosa monospecies biofilm formation, even with corrections made for total surface area (roughness). Importantly, O-BDD shows the lowest water contact angle of all materials tested, that is, greatest hydrophilicity, strongly suggesting that for these bacterial species, the factors controlling the hydrophilicity of the surface are important in reducing bacterial adhesion. This was further proven by keeping the surface topography fixed and changing surface termination to hydrogen (H-), to produce a strongly hydrophobic surface. A noticeable increase in biofilm formation was found. Doping with boron also results in changes in hydrophobicity/hydrophilicity compared to the undoped counterpart, which in turn affects the bacterial growth. For practical electrochemical sensing applications in aquatic environments, this study highlights the extremely beneficial effects of employing smooth, O-terminated (hydrophilic) BDD electrodes.


Assuntos
Biofilmes , Incrustação Biológica/prevenção & controle , Boro , Diamante , Pseudomonas aeruginosa/fisiologia , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Boro/química , Boro/farmacologia , Diamante/química , Diamante/farmacologia , Propriedades de Superfície
7.
J Appl Clin Med Phys ; 20(2): 13-23, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30632271

RESUMO

PURPOSE: The electron energy characteristics of mobile intraoperative radiotherapy (IORT) accelerator LIAC® differ from commonly used linear accelerators, thus some of the frequently used detectors can give less accurate results. The aim of this study is to evaluate the output factors (OFs) of several ionization chambers (IC) and solid state detectors (SS) for electron beam energies generated by LIAC® and compare with the output factor of Monte Carlo model (MC) in order to determine the adequate detectors for LIAC® . METHODS: The OFs were measured for 6, 8, 10, and 12 MeV electron energies with PTW 23343 Markus, PTW 34045 Advanced Markus, PTW 34001 Roos, IBA PPC05, IBA PPC40, IBA NACP-02, PTW 31010 Semiflex, PTW 31021 Semiflex 3D, PTW 31014 Pinpoint, PTW 60017 Diode E, PTW 60018 Diode SRS, SNC Diode EDGE, and PTW 60019 micro Diamond detectors. Ion recombination factors (ksat ) of IC were measured for all applicator sizes and OFs were corrected according to ksat . The measured OFs were compared with Monte Carlo output factors (OFMC ). RESULTS: The measured OFs of IBA PPC05, PTW Advanced Markus, PTW Pinpoint, PTW microDiamond, and PTW Diode E detectors are in good agreement with OFMC . The maximum deviations of IBA PPC05 OFs to OFMC are -1.6%, +1.5%, +1.5%, and +2.0%; for PTW Advanced Markus +1.0%, +1.5%, +2.0%, and +2.0%; for PTW Pinpoint +2.0%, +1.6%, +4.0%, and +2.0%; for PTW microDiamond -1.6%, +2%, +1.1%, and +1.0%; and for PTW Diode E -+1.7%, +1.7%, +1.3%, and +2.5% for 6, 8, 10, and 12 MeV, respectively. PTW Roos, PTW Markus, IBA PPC40, PTW Semiflex, PTW Semiflex 3D, SNC Diode Edge measured OFs with a maximum deviation of +5.6%, +4.5%, +5.6%, +8.1%, +4.8%, and +9.6% with respect to OFMC , while PTW Diode SRS and IBA NACP-02 were the least accurate (with highest deviations -37.1% and -18.0%, respectively). CONCLUSION: The OFs results of solid state detectors PTW microDiamond and PTW Diode E as well as the ICs with small electrode spacing distance such as IBA PPC05, PTW Advanced Markus and PTW Pinpoint are in excellent agreement with OFMC . The measurements of the other detectors evaluated in this study are less accurate, thus they should be used with caution. Particularly, PTW Diode SRS and IBA NACP-02 are not suitable and their use should be avoided in relative dosimetry measurements under high dose per pulsed (DPP) electron beams.


Assuntos
Elétrons , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Radioterapia Assistida por Computador/instrumentação , Diamante/química , Humanos , Período Intraoperatório , Método de Monte Carlo , Radiometria/classificação , Dosagem Radioterapêutica
8.
Radiat Prot Dosimetry ; 183(1-2): 167-171, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30544225

RESUMO

Microdosemeters are frequently used today to specify the radiation quality in the framework of ion-beam therapy. The heterogeneity of the detector shapes and the materials limits the possibility of comparing directly spectra and mean lineal energies. A method was recently studied to convert the spectra obtained with unidirectional ion beams in slab detectors to those obtained with detectors of different in shape and material. The method is based on the observation that the lineal-energy spectra of slab detector, in a restricted energy interval, approximate the Linear Energy Transfer distributions at corresponding material and particle type and energies. In this study, the experimental spectra collected with a slab diamond detector are converted to the spectra that would be obtained using water detectors of spherical and cylindrical shapes.


Assuntos
Diamante/química , Radioterapia com Íons Pesados , Radiometria/instrumentação , Água/química , Algoritmos , Transferência Linear de Energia , Método de Monte Carlo
9.
Phys Med Biol ; 62(17): 7036-7055, 2017 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-28791962

RESUMO

A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, [Formula: see text], was calculated for the MD, and the small field output correction factors, [Formula: see text], were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental [Formula: see text] values are in agreement within 1% with the MC calculated ones. Output correction factors within +0.7% and -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.


Assuntos
Diamante/química , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Radiometria/métodos , Calibragem , Humanos , Método de Monte Carlo , Fótons , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Silício/química
10.
Talanta ; 167: 208-216, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28340712

RESUMO

This work investigates the feasibility and sensitivity of a double-mediator based whole cell electrochemical biosensor to detect the acute biotoxicity of wastewater. The lipophilic mediator menadione was used to mediate the intracellular metabolic activities whereas hydrophilic potassium ferricyanide was employed as extracellular electron acceptor to transport the electron from the menadiol to anode. A chitosan hydrogel polymer film with boron-doped nanocrystalline diamond (BND) particles was electrodeposited onto a glassy carbon (GC) electrode to immobilize Saccharomyces cerevisiae cells and the mediators. The feasibility of the as-prepared biosensor was verified by determine the acute biotoxicity of four heavy metal ions(Cu2+, Cd2+, Ni2+, Pb2+), three phenol pollutants (3,5-dichlorophenol, 4-chlorophenol, phenol) and three real wastewater samples. The IC50 values for Cu2+, Cd2+, Ni2+, Pb2+ are 10.12mg/L,13.88mg/L, 17.06mg/L and 34.56mg/L. And the IC50 value is 16.48mg/L, 34.40mg/L and 44.55mg/L for 3,5-dichlorophenol, 4-chlorophenol and phenol, respectively. The results of this work indicate that the double-mediator based whole cell electrochemical biosensor could be applied into the acute toxicity assessment of real wastewater samples with excellent performance and highlight their merit as portable and sensitive, which may providing a reasonable and reliable way for wastewater toxicity online detection.


Assuntos
Técnicas Biossensoriais/métodos , Metais Pesados/toxicidade , Testes de Toxicidade Aguda/métodos , Águas Residuárias/química , Poluentes Químicos da Água/toxicidade , Técnicas Biossensoriais/instrumentação , Diamante/química , Eletroquímica , Eletrodos , Metais Pesados/análise , Fenóis/química , Poluentes Químicos da Água/análise
11.
J Environ Manage ; 195(Pt 2): 216-223, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27530074

RESUMO

Wastewater produced in pharmaceutical manufacturing plants (PMPs), especially the one coming from organic-synthesis facilities, is characterized by its large variability due to the wide range of solvents and chemical reagents used in the different stages of the production of medicines. Normally, the toxicity of the organic compounds prevent the utilization of biological processes and more powerful treatments are needed becoming advanced oxidation processes (AOPs) a valid alternative. In this work, the efficiency in abatement of pollution by Fenton oxidation (FO) and conductive-diamond electro-oxidation (CDEO) are compared in the treatment of 60 real effluents coming from different processes carried out in a pharmaceutical facility, using standardized tests. In 80% of the samples, CDEO was found to be more efficient than FO and in the remaining 20%, coagulation was found to exhibit a great significance in the COD abatement mechanism during FO, pointing out the effectiveness of the oxidation promoted by the electrochemical technology. Mean oxidation state of carbon was found to be a relevant parameter to understand the behavior of the oxidation technologies. It varied inversely proportional to efficiency in FO and it showed practically no influence in the case of CDEO.


Assuntos
Diamante/química , Eliminação de Resíduos Líquidos , Indústria Farmacêutica , Peróxido de Hidrogênio/química , Ferro/química , Oxirredução , Poluentes Químicos da Água
12.
J Appl Clin Med Phys ; 17(2): 291-303, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074452

RESUMO

Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue-equivalent properties. We investigated a commercially available 'microdiamond' detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1mm, thickness 1 x10(-3) mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ± 0.17% (1 SD) (n = 11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stop-ping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long-term stability and reproducibility. Based on micro-dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance.


Assuntos
Diamante/química , Elétrons , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Fótons , Calibragem , Humanos , Método de Monte Carlo
13.
J Vis Exp ; (107)2016 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-26779959

RESUMO

Boron doped diamond (BDD) electrodes have shown considerable promise as an electrode material where many of their reported properties such as extended solvent window, low background currents, corrosion resistance, etc., arise from the catalytically inert nature of the surface. However, if during the growth process, non-diamond-carbon (NDC) becomes incorporated into the electrode matrix, the electrochemical properties will change as the surface becomes more catalytically active. As such it is important that the electrochemist is aware of the quality and resulting key electrochemical properties of the BDD electrode prior to use. This paper describes a series of characterization steps, including Raman microscopy, capacitance, solvent window and redox electrochemistry, to ascertain whether the BDD electrode contains negligible NDC i.e. negligible sp(2) carbon. One application is highlighted which takes advantage of the catalytically inert and corrosion resistant nature of an NDC-free surface i.e. stable and quantifiable local proton and hydroxide production due to water electrolysis at a BDD electrode. An approach to measuring the local pH change induced by water electrolysis using iridium oxide coated BDD electrodes is also described in detail.


Assuntos
Boro/química , Diamante/química , Eletrodos , Água/química , Carbono/química , Eletroquímica , Eletrólise , Oxirredução , Análise Espectral Raman
14.
Phys Med Biol ; 60(24): 9421-36, 2015 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-26583596

RESUMO

This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diameters of their sensitive volumes ranging from 1 to 2.2 mm. The particular aim of the experiment was to examine the existence of significant negative portions of some of these response functions predicted by a recent Monte-Carlo-simulation (Looe et al 2015 Phys. Med. Biol. 60 6585-607). In a 6 MV photon slit beam formed by the Siemens Artiste collimation system and a 0.5 mm wide slit between 10 cm thick lead blocks serving as the tertiary collimator, the true cross-beam dose profile D(x) at 3 cm depth in a large water phantom was measured with radiochromic film EBT3, and the detector-affected cross-beam signal profiles M(x) were recorded with a silicon diode, a synthetic diamond detector, a miniaturized scintillation detector, and a small ionization chamber. For each detector, the deconvolution of the convolution integral M(x) = K(x) ∗ D(x) served to obtain its specific 1D lateral dose response function K(x), and K(r) was calculated from it. Fourier transformations and back transformations were performed using function approximations by weighted sums of Gaussian functions and their analytical transformation. The 1D lateral dose response functions K(x) of the four types of detectors and their associated rotational symmetric counterparts K(r) were obtained. Significant negative curve portions of K(x) and K(r) were observed in the case of the silicon diode and the diamond detector, confirming the Monte-Carlo-based prediction (Looe et al 2015 Phys. Med. Biol. 60 6585-607). They are typical for the perturbation of the secondary electron field by a detector with enhanced electron density compared with the surrounding water. In the cases of the scintillation detector and the small ionization chamber, the negative curve portions of K(x) practically vanish. It is planned to use the measured functions K(x) and K(r) to deconvolve clinical narrow-beam signal profiles and to correct the output factor values obtained with various high-resolution detectors.


Assuntos
Método de Monte Carlo , Imagens de Fantasmas , Fótons , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Diamante/química , Elétrons , Humanos , Distribuição Normal , Radiometria/métodos , Dosagem Radioterapêutica , Silício/química , Água/química
15.
Phys Med Biol ; 60(18): 7069-83, 2015 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-26309235

RESUMO

Ion-beam therapy provides a high dose conformity and increased radiobiological effectiveness with respect to conventional radiation-therapy. Strict constraints on the maximum uncertainty on the biological weighted dose and consequently on the biological weighting factor require the determination of the radiation quality, defined as the types and energy spectra of the radiation at a specific point. However the experimental determination of radiation quality, in particular for an internal target, is not simple and the features of ion interactions and treatment delivery require dedicated and optimized detectors. Recently chemical vapor deposition (CVD) diamond detectors have been suggested as ion-beam therapy microdosimeters. Diamond detectors can be manufactured with small cross sections and thin shapes, ideal to cope with the high fluence rate. However the sensitive volume of solid state detectors significantly deviates from conventional microdosimeters, with a diameter that can be up to 1000 times the height. This difference requires a redefinition of the concept of sensitive thickness and a deep study of the secondary to primary radiation, of the wall effects and of the impact of the orientation of the detector with respect to the radiation field. The present work intends to study through Monte Carlo simulations the impact of the detector geometry on the determination of radiation quality quantities, in particular on the relative contribution of primary and secondary radiation. The dependence of microdosimetric quantities such as the unrestricted linear energy L and the lineal energy y are investigated for different detector cross sections, by varying the particle type (carbon ions and protons) and its energy.


Assuntos
Diamante/química , Método de Monte Carlo , Prótons , Radiometria/instrumentação , Fótons , Radiometria/métodos , Incerteza
16.
Radiat Prot Dosimetry ; 166(1-4): 271-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26180078

RESUMO

Ion-beam therapy faces a growing demand of tools able to map radiation quality within the irradiated volume. Although analytical computations and simulations provide useful estimations of dose and radiation quality, the direct measure of those parameters would improve ion-beam therapy in particular when deep-seated tumours are irradiated, tissue composition and density are variable or organs at risk are near the tumour. Several ion-beam therapy facilities are studying detectors and procedures for measuring the radiation quality on a microdosimetric as well as a nanodosimetric scale. Simplicity and miniaturisation of the devices are essential for measurements first in phantoms and thereafter during therapy, particularly for intra-cavity detectors. MedAustron is studying solid-state detectors based on a single crystal chemical vapour deposition diamond. In collaboration with Italian National Institute for Nuclear Physics (INFN), Tor Vergata and Legnaro; INFN-microdosimetry and track structure project; Austrian Institute of Technology, Vienna; and Italian National agency for new technologies, energy and sustainable economic development, Rome, prototypes have been developed to characterise radiation quality in sizes equivalent to one micrometre of biological tissue.


Assuntos
Diamante/química , Radioterapia com Íons Pesados/normas , Neoplasias/radioterapia , Controle de Qualidade , Radiometria/instrumentação , Radiometria/métodos , Humanos , Doses de Radiação , Eficiência Biológica Relativa
17.
Phys Med Biol ; 60(15): 5813-31, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26161448

RESUMO

Recently, Alfonso et al proposed a new formalism for the dosimetry of small and non-standard fields. The proposed new formalism is strongly based on the calculation of detector-specific beam correction factors by Monte Carlo simulation methods, which accounts for the difference in the response of the detector between the small and the machine specific reference field. The correct calculation of the detector-specific beam correction factors demands an accurate knowledge of the linear accelerator, detector geometry and composition materials. The present work shows that the field factors in water may be determined experimentally using the daisy chain correction method down to a field size of 1 cm × 1 cm for a specific set of detectors. The detectors studied were: three mini-ionization chambers (PTW-31014, PTW-31006, IBA-CC01), three silicon-based diodes (PTW-60018, IBA-SFD and IBA-PFD) and one synthetic diamond detector (PTW-60019). Monte Carlo simulations and experimental measurements were performed for a 6 MV photon beam at 10 cm depth in water with a source-to-axis distance of 100 cm. The results show that the differences between the experimental and Monte Carlo calculated field factors are less than 0.5%-with the exception of the IBA-PFD-for field sizes between 1.5 cm × 1.5 cm and 5 cm × 5 cm. For the 1 cm × 1 cm field size, the differences are within 2%. By using the daisy chain correction method, it is possible to determine measured field factors in water. The results suggest that the daisy chain correction method is not suitable for measurements performed with the IBA-PFD detector. The latter is due to the presence of tungsten powder in the detector encapsulation material. The use of Monte Carlo calculated [Formula: see text] is encouraged for field sizes less than or equal to 1 cm × 1 cm for the dosimeters used in this work.


Assuntos
Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Fótons/uso terapêutico , Radiometria/instrumentação , Radioterapia/instrumentação , Água/química , Algoritmos , Simulação por Computador , Diamante/química , Humanos , Modelos Teóricos , Método de Monte Carlo , Radiometria/métodos , Radioterapia/métodos , Silício/química
18.
J Prosthet Dent ; 113(6): 616-22, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25794914

RESUMO

STATEMENT OF PROBLEM: During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. PURPOSE: The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. MATERIAL AND METHODS: A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. RESULTS: The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). CONCLUSIONS: The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30).


Assuntos
Cerâmica/química , Materiais Dentários/química , Polimento Dentário/instrumentação , Silicatos de Alumínio/química , Análise Custo-Benefício , Polimento Dentário/economia , Porcelana Dentária/química , Diamante/química , Humanos , Teste de Materiais , Propriedades de Superfície
19.
Aust Dent J ; 60(1): 12-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25721274

RESUMO

BACKGROUND: Erosive tooth wear and dentinal hypersensitivity are common problems affecting professional wine tasters. By using nanoscratch testing, the aim of this in vitro study was to assess enamel softening under conditions simulating 10 one-minute episodes of wine erosion. METHODS: Ten enamel specimens were bathed in artificial saliva for 2 hours before being eroded for 10 episodes, with each episode comprising one minute of wine erosion followed by one minute of remineralization in artificial saliva. Nanoscratches were placed with a spherical tip (20 µm radius) in a nanoindenter under a load of 100 mN at baseline (stage 1), after a one-erosion episode (stage 2) and after 10-erosion episodes (stage 3). RESULTS: There were significant effects of erosion stages on both scratch depth (p<0.001) and surface roughness (p<0.001). Post hoc tests showed significant differences in both scratch depths and surface roughness between stages 1 and 3 (p<0.001), and between stages 2 and 3 (p<0.01). CONCLUSIONS: Enamel softening occurs at an early stage of wine tasting, emphasizing the need to implement early preventive strategies in professional wine tasters. Further research elucidating the fundamental mechanisms involved in early stages of erosion has the potential to lead to development of more effective preventive strategies.


Assuntos
Esmalte Dentário/patologia , Desmineralização do Dente/etiologia , Erosão Dentária/etiologia , Vinho/efeitos adversos , Adolescente , Adulto , Esmalte Dentário/ultraestrutura , Sensibilidade da Dentina/etiologia , Diamante/química , Dureza , Humanos , Nanotecnologia/instrumentação , Doenças Profissionais/etiologia , Saliva Artificial/química , Estresse Mecânico , Fatores de Tempo , Erosão Dentária/prevenção & controle , Adulto Jovem
20.
Phys Med Biol ; 60(2): 905-24, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25564826

RESUMO

A CVD based radiation detector has recently become commercially available from the manufacturer PTW-Freiburg (Germany). This detector has a sensitive volume of 0.004 mm(3), a nominal sensitivity of 1 nC Gy(-1) and operates at 0 V. Unlike natural diamond based detectors, the CVD diamond detector reports a low dose rate dependence. The dosimetric properties investigated in this work were dose rate, angular dependence and detector sensitivity and linearity. Also, percentage depth dose, off-axis dose profiles and total scatter ratios were measured and compared against equivalent measurements performed with a stereotactic diode. A Monte Carlo simulation was carried out to estimate the CVD small beam correction factors for a 6 MV photon beam. The small beam correction factors were compared with those obtained from stereotactic diode and ionization chambers in the same irradiation conditions The experimental measurements were performed in 6 and 15 MV photon beams with the following square field sizes: 10 × 10, 5 × 5, 4 × 4, 3 × 3, 2 × 2, 1.5 × 1.5, 1 × 1 and 0.5 × 0.5 cm. The CVD detector showed an excellent signal stability (<0.2%) and linearity, negligible dose rate dependence (<0.2%) and lower response angular dependence. The percentage depth dose and off-axis dose profiles measurements were comparable (within 1%) to the measurements performed with ionization chamber and diode in both conventional and small radiotherapy beams. For the 0.5 × 0.5 cm, the measurements performed with the CVD detector showed a partial volume effect for all the dosimetric quantities measured. The Monte Carlo simulation showed that the small beam correction factors were close to unity (within 1.0%) for field sizes ≥1 cm. The synthetic diamond detector had high linearity, low angular and negligible dose rate dependence, and its response was energy independent within 1% for field sizes from 1.0 to 5.0 cm. This work provides new data showing the performance of the CVD detector compared against a high spatial resolution diode. It also presents a comparison of the CVD small beam correction factors with those of diode and ionization chamber for a 6 MV photon beam.


Assuntos
Diamante/análise , Diamante/química , Fótons/uso terapêutico , Radiometria/instrumentação , Radiometria/métodos , Radioterapia/instrumentação , Radioterapia/métodos , Humanos , Método de Monte Carlo , Aceleradores de Partículas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA