Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Med Ultrason ; 26(1): 83-90, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38150694

RESUMO

AIM: A standard assessment tool for direct evaluation of procedural skills to ensure proficiency of trainees is necessary for cranial ultrasound (US) in clinical practice. This study created and validated an assessment tool for cranial US performance by radiologists. MATERIAL AND METHODS: An initial evaluation tool for cranial US using criteria was developed based on existing literature. The assessment form was modified using a three-round Delphi process by an expert panel, conducted between January 2021 and April 2021. Rubric scales for grading were added once consensus regarding generated items was reached. Experts confirmed the final assessment tool using a rubric scale. Two raters evaluated cranial US performance of 27 residents in video clips using the tool. Reliability and percent agreement were assessed. RESULTS: Seventeen pediatric radiologists working in different settings participated in the expert panel. The content validation of the proposed evaluation tool was enabled by expert pediatric radiologists. Following three rounds of the Delphi process, the initial 14-item assessment form became a final 15-item form. A three-part rubric scale was used in the final form (preparation, US machine operation, and cranial US performance). Interrater reliability was evaluated with Cohen's Kappa. The Kappa value and percent interrater agreement for most items was moderate to almost perfect (0.42-0.93 and 77.8-100%, respectively). The Cronbach's alpha values for both raters were 0.856 and 0.891. CONCLUSIONS: This study produced the first validated cranial US assessment tool using a modified Delphi method. The final assessment form is a simple and reliable tool.


Assuntos
Ecoencefalografia , Radiologistas , Criança , Humanos , Reprodutibilidade dos Testes , Ultrassonografia , Competência Clínica
2.
Pediatrics ; 140(2)2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28771407

RESUMO

OBJECTIVES: We compared cost-effectiveness of cranial computed tomography (CT), fast sequence magnetic resonance imaging (fsMRI), and ultrasonography measurement of optic nerve sheath diameter (ONSD) for suspected acute shunt failure from the perspective of a health care organization. METHODS: We modeled 4 diagnostic imaging strategies: (1) CT scan, (2) fsMRI, (3) screening ONSD by using point of care ultrasound (POCUS) first, combined with CT, and (4) screening ONSD by using POCUS first, combined with fsMRI. All patients received an initial plain radiographic shunt series (SS). Short- and long-term costs of radiation-induced cancer were assessed with a Markov model. Effectiveness was measured as quality-adjusted life-years. Utilities and inputs for clinical variables were obtained from published literature. Sensitivity analyses were performed to evaluate the effects of parameter uncertainty. RESULTS: At a previous probability of shunt failure of 30%, a screening POCUS in patients with a normal SS was the most cost-effective. For children with abnormal SS or ONSD measurement, fsMRI was the preferred option over CT. Performing fsMRI on all patients would cost $269 770 to gain 1 additional quality-adjusted life-year compared with POCUS. An imaging pathway that involves CT alone was dominated by ONSD and fsMRI because it was more expensive and less effective. CONCLUSIONS: In children with low pretest probability of cranial shunt failure, an ultrasonographic measurement of ONSD is the preferred initial screening test. fsMRI is the more cost-effective, definitive imaging test when compared with cranial CT.


Assuntos
Ecoencefalografia/economia , Falha de Equipamento , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/cirurgia , Imageamento por Ressonância Magnética/economia , Nervo Óptico/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/economia , Tomografia Computadorizada por Raios X/economia , Derivação Ventriculoperitoneal/economia , Análise Custo-Benefício , Feminino , Humanos , Hidrocefalia/economia , Lactente , Recém-Nascido , Masculino , Anos de Vida Ajustados por Qualidade de Vida , Sensibilidade e Especificidade
3.
Ultraschall Med ; 38(3): 294-300, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27273178

RESUMO

Purpose One of the anatomical hallmarks of Alzheimer's disease (AD) is the atrophy of the medial temporal lobe (MTL), yet cost-effective and broadly available methodological alternatives to the current imaging tools for screening of this brain area are not currently available. Materials and Methods Using structural transcranial ultrasound (TCS), we attempted to visualize and measure the MTL, and compared the results of 32 AD patients and 84 healthy controls (HC). The MTL and the surrounding space were defined in the coronal plane on TCS. A ratio of the height of the MTL/height of the choroidal fissure (M/F) was calculated in order to obtain a regional proportion. Results An insufficient temporal bone window was identified in 22 % of the AD patients and 12 % of the HCs. The results showed that the ratio of M/F was significantly smaller in the AD group on both sides (p = 0.004 right, p = 0.007 left side). Furthermore, the M/F ratio made it possible to discriminate AD patients from HCs with a sensitivity of 83 % (right)/73 % (left) and a specificity of 76 % (right)/72 % (left) which is basically comparable to results published for magnetic resonance imaging. The measurements showed substantial intra/interrater reliability (ICC:0.79/0.69). Conclusion These results suggest that utilization of structural TCS may possibly constitute a cheap and easy-to-use supplement to other techniques for the diagnosis of AD. It may be especially useful as a screening tool in the large population of individuals with cognitive decline. Further studies are needed to validate this novel method.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Ecoencefalografia/métodos , Lobo Temporal/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/economia , Atrofia , Ventrículos Cerebrais/diagnóstico por imagem , Estudos de Coortes , Análise Custo-Benefício , Ecoencefalografia/economia , Feminino , Hipocampo/diagnóstico por imagem , Humanos , Masculino , Programas de Rastreamento/economia , Pessoa de Meia-Idade , Tamanho do Órgão/fisiologia , Valores de Referência , Sensibilidade e Especificidade , Estatística como Assunto , Lobo Temporal/patologia
4.
J Perinatol ; 36(11): 985-989, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27467565

RESUMO

OBJECTIVE: To evaluate the clinical impact of routine term-equivalent magnetic resonance imaging (TE-MRI) for extremely low-birth-weight infants at a regional neonatal intensive care unit. STUDY DESIGN: This is a single-center retrospective study evaluating preterm survivors who underwent TE-MRI. MRI abnormalities were compared between infants with and without cranial ultrasonography (CUS) abnormalities. Cost analysis comparing imaging modalities was also performed. RESULTS: TE-MRI use increased from 17% in 2006 to 76% in 2010. MRI detected new findings in nearly half of infants, whether or not they had known ultrasound abnormalities. MRI detected more cerebellar (18% vs 6%, P=0.04) and moderate white matter injury (12% vs 7%, P<0.001), and altered simulated neurological prognosis across developmental domains. The cost of TE-MRI was $1600, which was comparable to serial CUSs. CONCLUSION: TE-MRI detects new abnormalities and impacts developmental prognosis in the extremely low birth weight, which supports its use despite the added financial cost.


Assuntos
Encéfalo/diagnóstico por imagem , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Encéfalo/anormalidades , Estudos de Casos e Controles , Ecoencefalografia , Feminino , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Doenças do Prematuro/diagnóstico por imagem , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Imageamento por Ressonância Magnética/economia , Masculino , Estudos Retrospectivos , Estatísticas não Paramétricas , Ultrassonografia/economia
5.
Genet Mol Res ; 14(2): 3345-54, 2015 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-25966101

RESUMO

This study aimed to investigate the characteristic features of craniocerebral gunshot wounds by conventional ultrasound (CUS) and evaluate the efficacy of contrast-enhanced ultrasound (CEUS) in differentiation of tissue condition in wounds. Twenty crossbreed dogs (treatment: N = 15; control: N = 5) were used in the study. Pipe-shaped hyperechoes of varying size were found by CUS in most of the treated animals. The echoic areas were distinct from the neighboring brain tissue and did not change with time. CEUS revealed that the pipe-shaped echo was unenhanced in majority of the injured brains and the surrounding tissue was either heterogeneously enhanced or unenhanced. Pathological analysis confirmed that the contrast-filling-defect area indicated necrotic tissue and the heterogeneous minimally enhanced areas indicated degenerative tissue. CUS imaging enabled detection of hematomas and CEUS indicated that the filling defect was in the center of the hematoma, with enhancement gradually increasing towards the periphery. CUS could effectively detect a wound tract, hematoma, and the craniocerebral area injured by a gunshot, while CEUS could accurately reveal necrotic tissue in the injured area and differentiate the degenerative from normal tissue.


Assuntos
Encéfalo/patologia , Traumatismos Cranianos Penetrantes/diagnóstico por imagem , Ferimentos por Arma de Fogo/diagnóstico por imagem , Animais , Encéfalo/cirurgia , Cães , Ecoencefalografia , Traumatismos Cranianos Penetrantes/cirurgia , Cirurgia Assistida por Computador , Ferimentos por Arma de Fogo/cirurgia
6.
Fetal Diagn Ther ; 37(2): 93-101, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25138047

RESUMO

OBJECTIVES: To assess the inter- and intraobserver reliability of different fetal MRI measurements in cases of fetal brain malformations and to examine the concordance between ultrasonography (US) and MRI findings. METHODS: Fetal brain MRIs and US findings of 56 pregnant women were retrieved from the institutional database. Standardized fetal brain MRI measurements were performed by 4 observers, and the inter- and intraobserver reliability was determined. Additionally, US and MRI findings were retrospectively compared. RESULTS: The interobserver intraclass correlation coefficient (ICC) was above 0.9 for the cerebellum and posterior horn of the lateral ventricle. The measurements regarding the third ventricle (0.50), the fourth ventricle (0.58), and the corpus callosum (0.63) showed poor reliability. Overall, the intraobserver reliability was greater than the interobserver reliability. US and MRI findings were discordant in 29% of the cases with MRI rendering an extended diagnosis in 18%, a change of diagnosis in 3.6%, and excluding pathological findings suspected on US in 7.1%. CONCLUSIONS: Fetal MRI is a valuable complement to US in the investigation of fetal brain malformations. The reliability of most parameters was high, except for the measurements of the third and fourth ventricles and the corpus callosum.


Assuntos
Encéfalo/anormalidades , Imagem de Difusão por Ressonância Magnética/normas , Feto/anormalidades , Ultrassonografia Pré-Natal/normas , Adolescente , Adulto , Encéfalo/metabolismo , Ecoencefalografia/normas , Feminino , Feto/metabolismo , Humanos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes , Adulto Jovem
7.
Crit Care ; 18(6): 676, 2014 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-25488604

RESUMO

INTRODUCTION: Brain midline shift (MLS) is a life-threatening condition that requires urgent diagnosis and treatment. We aimed to validate bedside assessment of MLS with Transcranial Sonography (TCS) in neurosurgical ICU patients by comparing it to CT. METHODS: In this prospective single centre study, patients who underwent a head CT were included and a concomitant TCS performed. TCS MLS was determined by measuring the difference between the distance from skull to the third ventricle on both sides, using a 2 to 4 MHz probe through the temporal window. CT MLS was measured as the difference between the ideal midline and the septum pellucidum. A significant MLS was defined on head CT as > 0.5 cm. RESULTS: A total of 52 neurosurgical ICU patients were included. The MLS (mean ± SD) was 0.32 ± 0.36 cm using TCS and 0.47 ± 0.67 cm using CT. The Pearson's correlation coefficient (r(2)) between TCS and CT scan was 0.65 (P < 0.001). The bias was 0.09 cm and the limits of agreements were 1.10 and -0.92 cm. The area under the ROC curve for detecting a significant MLS with TCS was 0.86 (95% CI = 0.74 to 0.94), and, using 0.35 cm as a cut-off, the sensitivity was 84.2%, the specificity 84.8% and the positive likelihood ratio was 5.56. CONCLUSIONS: This study suggests that TCS could detect MLS with reasonable accuracy in neurosurgical ICU patients and that it could serve as a bedside tool to facilitate early diagnosis and treatment for patients with a significant intracranial mass effect.


Assuntos
Encéfalo/cirurgia , Ecoencefalografia/normas , Unidades de Terapia Intensiva/normas , Procedimentos Neurocirúrgicos/normas , Sistemas Automatizados de Assistência Junto ao Leito/normas , Ultrassonografia Doppler Transcraniana/normas , Adulto , Idoso , Encéfalo/patologia , Ecoencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/métodos , Estudos Prospectivos , Ultrassonografia Doppler Transcraniana/métodos
8.
Curr Pediatr Rev ; 10(1): 48-55, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25055863

RESUMO

Despite improvements in neonatal care, survivors of preterm birth are still at a significantly increased risk of developing life-long neurological difficulties including cerebral palsy and cognitive difficulties. Cranial ultrasound is routinely used in neonatal practice, but has a low sensitivity for identifying later neurodevelopmental difficulties. Magnetic Resonance Imaging (MRI) can be used to identify intracranial abnormalities with greater diagnostic accuracy in preterm infants, and theoretically might improve the planning and targeting of long-term neurodevelopmental care; reducing parental stress and unplanned healthcare utilisation; and ultimately may improve healthcare cost effectiveness. Furthermore, MR imaging offers the advantage of allowing the quantitative assessment of the integrity, growth and function of intracranial structures, thereby providing the means to develop sensitive biomarkers which may be predictive of later neurological impairment. However further work is needed to define the accuracy and value of diagnosis by MR and the techniques's precise role in care pathways for preterm infants.


Assuntos
Encéfalo/patologia , Paralisia Cerebral/patologia , Transtornos Cognitivos/patologia , Deficiências do Desenvolvimento/patologia , Ecoencefalografia , Imageamento por Ressonância Magnética , Encéfalo/crescimento & desenvolvimento , Encéfalo/fisiopatologia , Análise Custo-Benefício , Ecoencefalografia/economia , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro/crescimento & desenvolvimento , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Ultrasound Med Biol ; 39(5): 745-52, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23453375

RESUMO

We investigated whether real-time ultrasound perfusion imaging (rt-UPI) is able to detect perfusion changes related to arterial recanalization in the acute phase of middle cerebral artery (MCA) stroke. Twenty-four patients with acute territorial MCA stroke were examined with rt-UPI and transcranial color-coded duplex ultrasound (TCCD). Ultrasound studies were consecutively performed within 24 h and 72-96 h after stroke onset. Real-time UPI parameters of bolus kinetics (time to peak, rt-TTP) and of refill kinetics (plateau A and slope ß of the exponential replenishment curve) were calculated from regions of interest of ischemic versus normal brain tissue; these parameters were compared between early and follow-up examinations in patients who recanalized. At the early examination, there was a delay of rt-TTP in patients with MCA occlusion (rt-TTP [s]: 13.09 ± 3.21 vs. 10.16 ± 2.6; p = 0.01) and a lower value of the refill parameter ß (ß [1/s]: 0.62 ± 0.34 vs. 1.09 ± 0.58; p = 0.01) in ischemic compared with normal brain tissue, whereas there were no differences of the parameters A and Axß. At follow-up, the delay of rt-TTP was reversible once recanalization of an underlying MCA obstruction was demonstrated: rt-TTP [s], 13.09 ± 3.21 at 24 h versus 10.95 ± 1.5 at 72-96 h (p = 0.03). Correspondingly, ß showed a higher slope than at the first examination: ß [1/s]: 0.55 ± 0.29 at 24 h versus 0.71 ± 0.27 at 72-96 h (p = 0.04). We conclude that real-time UPI can detect hemodynamic impairment in acute MCA occlusion and subsequent improvement following arterial recanalization. This offers the chance for bedside monitoring of the hemodynamic compromise (e.g. during therapeutic interventions such as systemic thrombolysis).


Assuntos
Algoritmos , Ecoencefalografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/tratamento farmacológico , Imagem de Perfusão/métodos , Ativador de Plasminogênio Tecidual/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
10.
J Neuroimaging ; 23(2): 237-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21883624

RESUMO

OBJECTIVE: To investigate the potential of the ultrasound-based evaluation of the optic nerve sheath in a patient with spontaneous intracranial hypotension due to cervical cerebrospinal fluid (CSF) leakage. METHODS: Repeated measurements of the optic nerve sheath diameter (ONSD) using B-mode sonography were performed before treatment initiation, during medical treatment, and during a course of repeated placement of epidural blood patches. RESULTS: On admission, transorbital sonography revealed a decreased ONSD of 4.1 mm on the right and 4.3 mm on the left side. After 8 months of treatment with caffeine and computed tomography-guided epidural blood patches a gradual distension of the ONSD into the normal range was bilaterally observed (right: 5.2 mm; left: 5.3 mm). CONCLUSIONS: The ultrasound-based evaluation of the optic nerve sheath may be helpful in detecting CSF hypovolemia and for determination of treatment effects. This report should be seen as a basis for future investigations on the sonographic assessment of the optic nerve sheath in diagnosis and treatment of intracranial hypotension.


Assuntos
Placa de Sangue Epidural , Ecoencefalografia/métodos , Hipotensão Intracraniana/diagnóstico por imagem , Hipotensão Intracraniana/etiologia , Nervo Óptico/diagnóstico por imagem , Derrame Subdural/complicações , Derrame Subdural/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Órbita/diagnóstico por imagem , Resultado do Tratamento
11.
J Biomed Opt ; 17(10): 106007, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23224006

RESUMO

We report the development of functional photoacoustic microscopy capable of video-rate high-resolution in vivo imaging in deep tissue. A lightweight photoacoustic probe is made of a single-element broadband ultrasound transducer, a compact photoacoustic beam combiner, and a bright-field light delivery system. Focused broadband ultrasound detection provides a 44-µm lateral resolution and a 28-µm axial resolution based on the envelope (a 15-µm axial resolution based on the raw RF signal). Due to the efficient bright-field light delivery, the system can image as deep as 4.8 mm in vivo using low excitation pulse energy (28 µJ per pulse, 0.35 mJ/cm² on the skin surface). The photoacoustic probe is mounted on a fast-scanning voice-coil scanner to acquire 40 two-dimensional (2-D) B-scan images per second over a 9-mm range. High-resolution anatomical imaging is demonstrated in the mouse ear and brain. Via fast dual-wavelength switching, oxygen dynamics of mouse cardio-vasculature is imaged in realtime as well.


Assuntos
Microscopia Acústica/métodos , Microscopia de Vídeo/métodos , Técnicas Fotoacústicas/instrumentação , Animais , Encéfalo/irrigação sanguínea , Simulação por Computador , Orelha/irrigação sanguínea , Orelha/diagnóstico por imagem , Ecoencefalografia , Hiperóxia/sangue , Hipóxia/sangue , Camundongos , Camundongos Nus , Microscopia Acústica/instrumentação , Microvasos , Método de Monte Carlo
12.
Prenat Diagn ; 32(12): 1143-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23034742

RESUMO

OBJECTIVE: To evaluate the routine midsagittal view of the posterior brain at the 11-13 weeks' ultrasound examination, for predicting open neural tube defects. METHODS: Posterior brain was examined midsagittally for normality of the four-line view (upper and lower border of the brain stem, the choroid plexus of the fourth ventricle and the occipital bone). Intracranial translucency and cisterna magna (CM) were measured. RESULTS: The posterior brain was assessed in 1330 cases. The four-line view was normal in all but one case. In the two cases of open spina bifida contained in the study population, intracranial translucency was within normal range. The CM and the four-line view were normal in the first case, whereas in the second case, the four-line view was abnormal, and CM was obliterated and impossible to measure. No other cases of abnormal four-line view were observed in the study population. CONCLUSION: Obliteration of the CM appears to be the most consistent early sign of open neural tube defects. Attention should focus on either measuring the cisterna magna or simply observing the presence of four lines in the midsagittal view of the posterior brain. However, these early signs of brain herniation are not present in all abnormal cases.


Assuntos
Ecoencefalografia , Defeitos do Tubo Neural/diagnóstico por imagem , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal , Encéfalo/embriologia , Encéfalo/patologia , Cisterna Magna/diagnóstico por imagem , Estatura Cabeça-Cóccix , Ecoencefalografia/métodos , Feminino , Quarto Ventrículo/diagnóstico por imagem , Idade Gestacional , Humanos , Gravidez , Resultado da Gravidez , Primeiro Trimestre da Gravidez/fisiologia , Prognóstico , Estudos Retrospectivos , Espinha Bífida Cística/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos
13.
Ultrasound Med Biol ; 38(8): 1333-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22698503

RESUMO

Increased blood flow velocity (BFV) in basal cerebral arteries measured by transcranial color-coded sonography (TCCS) is a stroke risk factor in sickle cell disease (SCD). Raised BFV may be caused by vessel narrowing or by hyperperfusion. In 44 SCD patients and 14 controls, intracranial arterial BFVs and global cerebral blood flow (CBF) were analyzed by TCCS and extracranial duplex ultrasound, respectively. Magnetic resonance imaging and magnetic resonance angiography were performed in all patients with pathologic intracranial BFV rise. Intracranial BFVs and CBF in SCD were significantly higher than in controls. CBF in SCD correlated with BFV in all intracranial arteries and correlated inversely with age and hemoglobin values. Magnetic resonance angiography failed to demonstrate any stenosis in our SCD patients, thus raised intracranial BFVs must be interpreted as an anemia-dependent cerebral hyperperfusion. These findings suggest that the pathomechanism of stenosis-derived arterio-arterial embolism might be less relevant in SCD-related ischemic stroke, and other factors like small vessel disease or sickle cell-induced microvascular blood clotting have to be considered.


Assuntos
Anemia Falciforme/diagnóstico por imagem , Anemia Falciforme/fisiopatologia , Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo , Circulação Cerebrovascular , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Adolescente , Anemia Falciforme/complicações , Velocidade do Fluxo Sanguíneo , Transtornos Cerebrovasculares/etiologia , Criança , Pré-Escolar , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/fisiopatologia , Ecoencefalografia/métodos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
J Neuroimaging ; 22(1): 42-5, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21121998

RESUMO

BACKGROUND: The use of an ultrasound-based evaluation of the optic nerve sheath diameter (ONSD) has previously been demonstrated for detecting raised intracranial pressure. In order to be feasible in clinical workup, the test qualities of transorbital ultrasonography need to be determined. The aim of this study was therefore to establish normal values and to assess the intra- and interobserver reliability of this method. METHODS: Using a 9-3 MHz linear array transducer, the ONSD of 40 healthy subjects was independently measured by 2 investigators. RESULTS: Depicting the optic nerve and its sheath was possible in all individuals. The mean ONSD was 5.4 ± .6 mm with a range of 4.3-7.6 mm. The intraobserver reliability analyzed with Cronbach's Alpha was found to be high with values between .92 and .97. Pearson's correlation coefficient between the 2 investigators was .81 on the right side and .84 on the left. There was no correlation between ONSD and age, body mass index, or gender. CONCLUSIONS: Transorbital B-mode sonography is a feasible method to assess the ONSD with a high intra- and interobsever reliability. Normal values on ONSD are presented in this study that will be useful in future studies on pathological conditions.


Assuntos
Ecoencefalografia/métodos , Nervo Óptico/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
16.
Neurosurg Clin N Am ; 23(1): 165-77, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22107867

RESUMO

The vein of Galen aneurysmal malformation is a congenital vascular malformation that comprises 30% of the pediatric vascular and 1% of all pediatric congenital anomalies. Treatment is dependent on the timing of presentation and clinical manifestations. With the development of endovascular techniques, treatment paradigms have changed and clinical outcomes have significantly improved. In this article, the developmental embryology, clinical features and pathophysiology, diagnostic workup, and management strategies are reviewed.


Assuntos
Veias Cerebrais , Malformações da Veia de Galeno , Veias Cerebrais/anormalidades , Veias Cerebrais/anatomia & histologia , Veias Cerebrais/embriologia , Ecoencefalografia , Embolização Terapêutica , Procedimentos Endovasculares , História do Século XIX , História do Século XX , Humanos , Lactente , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Procedimentos Neurocirúrgicos , Tomografia Computadorizada por Raios X , Malformações da Veia de Galeno/diagnóstico , Malformações da Veia de Galeno/epidemiologia , Malformações da Veia de Galeno/história , Malformações da Veia de Galeno/terapia
17.
J Matern Fetal Neonatal Med ; 25(8): 1267-72, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22122157

RESUMO

OBJECTIVE: To assess differences in fetal behavior in both normal fetuses and fetuses with cerebral ventriculomegaly (VM). METHODS: In a period of eighteen months, in a longitudinal prospective cohort study, Kurjak Antenatal NeuorogicalTest (KANET) was applied to assess fetal behavior in both normal pregnancies and pregnancies with cerebral VM using four-dimensional ultrasound (4D US). According to the degree of enlargement of the ventricles, VM was divided into three groups: mild, moderate and severe. Moreover fetuses with isolated VM were separated from those with additional abnormalities. According to the KANET, fetuses with scores ≥ 14 were considered normal, those with scores 6-13 borderline and abnormal if the score was ≤ 5. Differences between two groups were examined by Fisher's exact test. Differences within the subgroups were examined by Kruskal-Wallis test and contingency table test. RESULTS: KANET scores in normal pregnancies and pregnancies with VM showed statistically significant differences. Most of the abnormal KANET scores as well as most of the borderline-scores were found among the fetuses with severe VM associated with additional abnormalities. There were no statistically significant differences between the control group and the groups with isolated and mild and /or moderate VM. CONCLUSION: Evaluation of the fetal behavior in fetuses with cerebral VM using KANET test has the potential to detect fetuses with abnormal behavior, and to add the dimension of CNS function to the morphological criteria of VM. Long-term postnatal neurodevelopmental follow-up should confirm the data from prenatal investigation of fetal behavior.


Assuntos
Encéfalo/fisiopatologia , Técnicas de Diagnóstico Neurológico , Feto/fisiopatologia , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Estudos de Casos e Controles , Estudos de Coortes , Ecoencefalografia/métodos , Feminino , Movimento Fetal/fisiologia , Humanos , Hidrocefalia/congênito , Estudos Longitudinais , Gravidez , Resultado da Gravidez , Projetos de Pesquisa
18.
J Neuroradiol ; 38(5): 291-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21396715

RESUMO

BACKGROUND: Cranial ultrasound (cUS) findings help doctors in the clinical management of preterm infants and in their discussion with parents regarding prediction of outcome. cUS is often used as outcome measure in clinical research studies. Accurate cUS performance and interpretation is therefore required. AIMS: The aims of this study were (i) to assess the interobserver variability in cUS interpretation, and (ii) to evaluate whether level of cUS expertise influences the interobserver variability. METHODS: Fifty-eight cUS image series of preterm infants born below 32 weeks of gestation collected within the Swiss Neonatal Network were sent to 27 observers for reviewing. Observers were grouped into radiologists, experienced neonatologists and less experienced neonatologists. Agreement between observers was calculated using Kappa statistics. RESULTS: When cystic periventricular leukomalacia, intraventricular haemorrhage and periventricular haemorrhagic infarction were combined to one outcome, agreement among all observers was moderate. When divided into subgroups, kappa for the combined outcome was 0.7 for experienced neonatologists, 0.67 for radiologists and 0.53 for inexperienced neonatologists. Marked difference in interobserver agreement between experienced neonatologists and radiologists could be found for haemorrhagic periventricular ifraction (HPI). CONCLUSIONS: Our results suggest that interobserver agreement for interpretation of cUS varies from poor to good varying with the type of abnormality and level of expertise, suggesting that widespread structured training should be made available to improve the performance and interpretation of cUS.


Assuntos
Encefalopatias/diagnóstico por imagem , Ecoencefalografia/métodos , Recém-Nascido Prematuro , Feminino , Humanos , Recém-Nascido , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suíça
19.
Artigo em Inglês | MEDLINE | ID: mdl-22254376

RESUMO

The Chronic Cerebro-Spinal Venous Insufficiency, recently described as a possible role in Multiple Sclerosis pathogenesis, is diagnosed and classified with Echo Color Doppler (ECD) examination of the extra- and intra-cranial veins. As to the intracranial examination, the presence of reflux in the deep cerebral veins (DCVs) or in the dural sinuses is inspected, with a new insonation approach, i.e. the transcondylar window. This work describes a procedure for the co-registration of anatomical Proton Density-weighted Magnetic Resonance Images (MRI) with the intracranial ECD obtained through the transcondylar window. The procedure, preliminarily tested on 10 volunteers, allowed to assess what are the DCVs visible from this new insonation approach and their position relative to the surrounding brain tissues.


Assuntos
Angiografia Cerebral/métodos , Veias Cerebrais/anatomia & histologia , Veias Cerebrais/diagnóstico por imagem , Ecoencefalografia/métodos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Técnica de Subtração , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Rev. bras. ginecol. obstet ; 32(12): 573-578, dez. 2010. graf, tab
Artigo em Português | LILACS | ID: lil-581579

RESUMO

OBJETIVO: determinar os valores de referência para o comprimento e a área do corpo caloso fetal entre a 20ª e 33ª semanas de gestação por meio da ultrassonografia tridimensional (US3D). MÉTODOS: foi realizado um estudo do tipo corte transversal com 70 gestantes normais entre a 20ª e 33ª semanas de gestação. Utilizou-se um aparelho da marca Accuvix XQ, equipado com transdutor convexo volumétrico (3 a 5 MHz). Para a obtenção do corpo caloso fetal, foi utilizado um plano transfrontal, com a sutura metópica como janela acústica. Para o cálculo do comprimento, utilizou-se a distância entre os pontos médios dos polos proximal e distal do corpo caloso. Para o cálculo da área, a delimitação manual da superfície externa do corpo caloso foi realizada. Para o comprimento e a área do corpo caloso, foram calculadas: as médias, as medianas, os desvios padrão e os valores máximo e mínimo. Para a correlação da área e do comprimento do corpo caloso com a idade gestacional e o diâmetro biparietal foram criados diagramas de dispersão, sendo a qualidade dos ajustes verificada pelo coeficiente de determinação (R²). Para a variabilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI). RESULTADOS: a média do comprimento do corpo caloso variou de 21,7 mm (18,6 - 25,2 mm) a 38,7 mm (32,6 - 43,3 mm) entre a 20ªe 33ª semanas, respectivamente. A média da área do corpo caloso variou de 55,2 mm² (41,0 - 80,0 mm²) a 142,2 mm² (114,0 - 160,0 mm²) entre a 20ªe 33ª semanas, respectivamente. O comprimento e a área do corpo caloso foram fortemente correlacionados com a idade gestacional (R² = 0,7 e 0,7, respectivamente) e com o diâmetro biparietal (R² = 0,7 e 0,6, respectivamente). A variabilidade intraobservador foi adequada com CCI = 0,9 e 0,9 para o comprimento e área, respectivamente. CONCLUSÕES: valores de referência para o comprimento e área do corpo caloso fetal entre a 20ªe 33ª semanas foram determinados. A variabilidade intraobservador foi adequada.


PURPOSE: to establish reference values for the length and area of the fetal corpus callosum between the 20th and 33rd weeks of gestation using three-dimensional ultrasound (3DUS). METHODS: this cross-sectional study involved 70 normal pregnancies with gestational age between 20 and 33 weeks. An Accuvix XQ instrument with a convex volumetric transducer (3 to 5 MHz) was used. To assess the corpus callosum, a transfrontal plane was obtained using the metopic suture as an acoustic window. Length was obtained by measuring the distance between the proximal and distal extremities of the corpus callosum. Area was obtained by manual tracing of the external corpus callosum surface. The means, medians, standard deviations, and maximum and minimum values were calculated for the corpus callosum length and area. Scatter graphs were created to analyze the correlation between corpus callosum length and area and gestational age and biparietal diameter, the quality adjustments was verified according to the determination coefficient (R²). The intraclass correlation coefficient (ICC) was used to assess the intraobserver variability. RESULTS: mean corpus callosum length increased from 21.7 (18.6 - 25.2 mm) to 38.7 mm (32.6 - 43.3 mm) between 20 and 33 weeks of pregnancy, respectively. Mean corpus callosum area increased from 55.2 (41.0 - 80.0 mm²) to 142.2 mm² (114.0 - 160.0 mm²), between 20 to 33 weeks of pregnancy, respectively. There was a strong correlation between corpus callosum length and area and gestational age (R² = 0.7 and 0.7, respectively) and biparietal diameter (R² = 0.7 and 0.6, respectively). Intraobserver variability was appropriate, with an ICC of 0.9 and 0.9 for length and area, respectively. CONCLUSIONS: reference values for corpus callosum length and area were established for fetuses between 20 and 33 weeks gestation. Intraobserver variability was appropriate.


Assuntos
Feminino , Humanos , Gravidez , Corpo Caloso/embriologia , Corpo Caloso , Ecoencefalografia , Imageamento Tridimensional , Ultrassonografia Pré-Natal , Estudos Transversais , Idade Gestacional , Tamanho do Órgão , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA