Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 251: 24-31, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36948371

RESUMO

PURPOSE: To explore the biometric characteristics of the ciliary body in patients with Marfan syndrome (MFS) and ectopia lentis (EL). DESIGN: Cross-sectional study. METHODS: Seventy-two consecutive patients with MFS and EL and 72 nondiseased control subjects were recruited. Ciliary body biometric parameters such as ciliary muscle cross-sectional area at 2000 µm from the scleral spur (CMA2000), ciliary muscle thickness at 1000 µm from the scleral spur (CMT1000), and maximum ciliary body thickness (CBTmax) were measured from multiple directions with ultrasound biomicroscopy (UBM). The relationship between ciliary body parameters and other ocular characteristics was also evaluated. RESULTS: Average CMA2000, CMT1000, and CBTmax were 0.692 ± 0.015 mm2, 0.405 ± 0.010 mm, and 0.855 ± 0.023 mm in eyes of patients with MFS, respectively, and were significantly smaller than these values in control subjects (all P < .001). The prevalence of ciliary body thinning was 22.2% in the MFS group vs 0 in the control group (P < .001); eyes with more severe EL had smaller CMA2000 (P = .050), thinner CMT1000 (P = .022), and shorter CBTmax (P = .015). Patients with microspherophakia (MSP) had even smaller CMA2000 (P = .033) and CMT1000 (P = .044) than those without MSP. The most common subluxation direction was in the superonasal quadrant (n = 25; 39.7%), which probably correlates with the thinnest CMT1000 in the inferotemporal quadrant (P = .005). CONCLUSIONS: Patients with MFS and EL had thinner ciliary muscles, shorter ciliary processes, and a higher prevalence of ciliary body thinning, especially those with MSP. Both the extent and direction of subluxation were associated with ciliary body biometry..


Assuntos
Ectopia do Cristalino , Glaucoma de Ângulo Fechado , Síndrome de Marfan , Humanos , Corpo Ciliar/diagnóstico por imagem , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Microscopia Acústica , Ectopia do Cristalino/diagnóstico , Ectopia do Cristalino/etiologia , Estudos Transversais , Glaucoma de Ângulo Fechado/complicações
2.
Arch Ophthalmol ; 114(9): 1058-61, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8790089

RESUMO

OBJECTIVE: To determine the effectiveness of combined pars plana vitrectomy-lensectomy and open-loop anterior chamber lens implantation for the management of ectopia lentis associated with Marfan syndrome. METHODS: Retrospective review of the medical records of 4 consecutive patients with Marfan syndrome who underwent combined pars plana lensectomy-vitrectomy and anterior chamber lens implantation at our institution between August 1994 and July 1995. RESULTS: All patients demonstrated postoperative visual acuity of 20/25 or better during an average follow-up period of 6 months (range, 4-9 months). Two patients developed pseudophakic pupillary block and required YAG laser iridotomy postoperatively. CONCLUSIONS: Pars plana lensectomy-vitrectomy and anterior chamber intraocular lens implantation appears to be an excellent technique for the management of ectopia lentis associated with Marfan syndrome. A bimanual, closed-system endosurgical technique avoids many of the complications previously associated with surgery for ectopia lentis.


Assuntos
Ectopia do Cristalino/cirurgia , Síndrome de Marfan/complicações , Adulto , Câmara Anterior/cirurgia , Ectopia do Cristalino/etiologia , Saúde da Família , Humanos , Cristalino/cirurgia , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Acuidade Visual , Vitrectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA