Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
Curr Vasc Pharmacol ; 19(1): 34-40, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32096744

RESUMO

Volume overload is the most common complication in end-stage renal disease (ESRD) patients, being directly related to numerous complications including resistant hypertension, cardiac hypertrophy, congestive heart failure or arterial stiffness, among others. Therefore, volume overload is now considered an important risk factor for hard outcomes, like all-cause or cardiovascular mortality. Relying solely on clinical examination for assessing volume overload in ESRD patients lacks sensitivity and specificity. Numerous efforts have been made to identify new methods that could objectively assess volume status; however, each of them has important limitations. This review aims to discuss the most frequently used methods (biomarkers, inferior vena cava assessment, lung ultrasonography, bioimpedance analysis and blood volume monitoring) and to compare the advantage of each method vs. the overall/ clinical strategy.


Assuntos
Composição Corporal , Doenças Cardiovasculares/diagnóstico , Sistema Cardiovascular/fisiopatologia , Falência Renal Crônica/terapia , Rim/fisiopatologia , Diálise Renal , Equilíbrio Hidroeletrolítico , Biomarcadores/metabolismo , Doenças Cardiovasculares/fisiopatologia , Impedância Elétrica , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/fisiopatologia , Valor Preditivo dos Testes , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/fisiopatologia , Diálise Renal/efeitos adversos , Reprodutibilidade dos Testes , Fatores de Risco , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem
3.
PLoS One ; 15(11): e0241590, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33180805

RESUMO

OBJECTIVES: The aim of this study was to establish quantitative CT (qCT) parameters for pathophysiological understanding and clinical use in patients with acute respiratory distress syndrome (ARDS). The most promising parameter is introduced. MATERIALS AND METHODS: 28 intubated patients with ARDS obtained a conventional CT scan in end-expiratory breathhold within the first 48 hours after admission to intensive care unit (ICU). Following manual segmentation, 137 volume- and lung weight-associated qCT parameters were correlated with 71 clinical parameters such as blood gases, applied ventilation pressures, pulse contour cardiac output measurements and established status and prognosis scores (SOFA, SAPS II). RESULTS: Of all examined qCT parameters, excess lung weight (ELW), i.e. the difference between a patient's current lung weight and the virtual lung weight of a healthy person at the same height, displayed the most significant results. ELW correlated significantly with the amount of inflated lung tissue [%] (p<0.0001; r = -0.66) and was closely associated with the amount of extravascular lung water (EVLW) (p<0.0001; r = 0.72). More substantially than the oxygenation index (PaO2/FiO2) or any other clinical parameter it correlated with the patients' mean SOFA- (p<0.0001, r = 0.69) and SAPS II-Score (p = 0.0005, r = 0.62). Patients who did not survive intensive care treatment displayed higher values of ELW in the initial CT scans. CONCLUSIONS: ELW could serve as a non-invasive method to quantify the amount of pulmonary oedema. It might serve as an early radiological marker of severity in patients with ARDS.


Assuntos
Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico , Síndrome do Desconforto Respiratório/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Pulmão/fisiopatologia , Medidas de Volume Pulmonar/métodos , Masculino , Pessoa de Meia-Idade , Edema Pulmonar/etiologia , Edema Pulmonar/mortalidade , Edema Pulmonar/fisiopatologia , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/mortalidade , Síndrome do Desconforto Respiratório/fisiopatologia , Testes de Função Respiratória , Índice de Gravidade de Doença
4.
Respir Physiol Neurobiol ; 263: 14-19, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30794965

RESUMO

Sonographic B-lines can indicate pulmonary interstitial edema. We sought to determine the incidence of subclinical pulmonary edema measured by sonographic B-lines among lowland trekkers ascending to high altitude in the Nepal Himalaya. Twenty healthy trekkers underwent portable sonographic examinations and arterial blood draws during ascent to 5160 m over ten days. B-lines were identified in twelve participants and more frequent at 4240 m and 5160 m compared to lower altitudes (P < 0.03). There was a strong negative correlation between arterial oxygen saturation and the number of B-lines at 5160 m (ρ = -0.75, P = 0.008). Our study contributes to the growing body of literature demonstrating the development of asymptomatic pulmonary edema during ascent to high altitude. Portable lung sonography may have utility in fieldwork contexts such as trekking at altitude, but further research is needed in order to clarify its potential clinical applicability.


Assuntos
Altitude , Pulmão/diagnóstico por imagem , Montanhismo/fisiologia , Edema Pulmonar/diagnóstico por imagem , Ultrassonografia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Nepal , Estudos Prospectivos , Edema Pulmonar/sangue , Edema Pulmonar/fisiopatologia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/normas , Adulto Jovem
5.
J Heart Lung Transplant ; 38(1): 83-91, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30391201

RESUMO

BACKGROUND: Single transpulmonary thermodilution (SD) with extravascular lung water index (EVLWI) could become a new tool to better assess lung graft edema during ex-vivo lung perfusion (EVLP). In this study we compare EVLWI with conventional methods to better select lungs during EVLP and to predict post-transplant primary graft dysfunction (PGD). METHODS: We measured EVLWI, arterial oxygen/fraction of inspired oxygen (P/F) ratio, and static lung compliance (SLC) during EVLP in an observational study. At the end of EVLP, grafts were accepted or rejected according to a standardized protocol blinded to EVLWI results. We compared the respective ability of EVLWI, P/F, and SLC to predict PGD. Mann-Whitney U-test, Fisher's exact test, and receiver-operating characteristic (ROC) curve data were used for analysis. p < 0.05 was considered statistically significant. RESULTS: Thirty-five lungs were evaluated by SD during EVLP. Three lungs were rejected for pulmonary edema. Thirty-two patients were transplanted, 8 patients developed Grade 2 or 3 PGD, and 24 patients developed Grade 0 or 1 PGD. In contrast to P/F ratio, SLC, and pulmonary artery pressure, EVLWI differed between these 2 populations (p < 0.001). The area under the ROC for EVLWI assessing Grade 2 or 3 PGD at the end of EVLP was 0.93. Donor lungs with EVLWI >7.5 ml/kg were more likely associated with a higher incidence of Grade 2 or 3 PGD at Day 3. CONCLUSIONS: Increased EVLWI during EVLP was associated with PGD in recipients.


Assuntos
Perfusão/efeitos adversos , Disfunção Primária do Enxerto/prevenção & controle , Edema Pulmonar/diagnóstico , Termodiluição/métodos , Doadores de Tecidos , Adulto , Água Extravascular Pulmonar , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Pressão Propulsora Pulmonar , Curva ROC , Estudos Retrospectivos
6.
Radiol Oncol ; 52(4): 377-382, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30511937

RESUMO

Background There are no data on usefulness of optic nerve sheath diameter (ONSD) as a marker of patient's fluid status in preeclampsia. The objective was to examine potential correlation between ONSD and lung ultrasound estimates of extravascular lung water in severe preeclampsia. Patients and methods Thirty patients with severe preeclampsia were included. Optic and lung ultrasound were performed within 24 hours from delivery. ONSD was measured 3 mm behind the globe. Lung ultrasound Echo Comet Score (ECS) was obtained summing B-lines ("comet tails") in parasternal intercostal spaces bilaterally. Pearson's correlation analysis was used to assess the relationship between ONSD and ECS (p < 0.05 significant). Results Median ONSD was 5.7 mm (range 3.8-7.5 mm). Median ECS value was 19 (range 0-24). Statistically significant correlation was found between ONSD and ECS (r2 = 0.464; p < 0.001). Conclusions Significant correlation between ONSD and ECS suggests optic ultrasound could be used for assessing fluid status and guiding peripartum fluid therapy in patients with severe preeclampsia.


Assuntos
Hipertensão Intracraniana/fisiopatologia , Pressão Intracraniana/fisiologia , Nervo Óptico/diagnóstico por imagem , Pré-Eclâmpsia/fisiopatologia , Ultrassonografia/métodos , Desequilíbrio Hidroeletrolítico/fisiopatologia , Adulto , Água Extravascular Pulmonar , Feminino , Humanos , Gravidez , Estudos Prospectivos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/fisiopatologia , Reprodutibilidade dos Testes
7.
J Cardiothorac Vasc Anesth ; 32(2): 901-914, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29174750

RESUMO

Pulmonary edema increasingly is recognized as a perioperative complication affecting outcome. Several risk factors have been identified, including those of cardiogenic origin, such as heart failure or excessive fluid administration, and those related to increased pulmonary capillary permeability secondary to inflammatory mediators. Effective treatment requires prompt diagnosis and early intervention. Consequently, over the past 2 centuries a concentrated effort to develop clinical tools to rapidly diagnose pulmonary edema and track response to treatment has occurred. The ideal properties of such a tool would include high sensitivity and specificity, easy availability, and the ability to diagnose early accumulation of lung water before the development of the full clinical presentation. In addition, clinicians highly value the ability to precisely quantify extravascular lung water accumulation and differentiate hydrostatic from high permeability etiologies of pulmonary edema. In this review, advances in understanding the physiology of extravascular lung water accumulation in health and in disease and the various mechanisms that protect against the development of pulmonary edema under physiologic conditions are discussed. In addition, the various bedside modalities available to diagnose early accumulation of extravascular lung water and pulmonary edema, including chest auscultation, chest roentgenography, lung ultrasonography, and transpulmonary thermodilution, are examined. Furthermore, advantages and limitations of these methods for the operating room and intensive care unit that are critical for proper modality selection in each individual case are explored.


Assuntos
Edema Pulmonar/diagnóstico , Água Extravascular Pulmonar/fisiologia , Humanos , Pulmão/diagnóstico por imagem , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Radiografia Torácica , Termodiluição
8.
Cardiovasc Res ; 113(10): 1113-1123, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28472392

RESUMO

AIMS: Heart failure (HF) has become an epidemic and constitutes a major medical, social, and economic problem worldwide. Despite advances in medical treatment, HF prognosis remains poor. The development of efficient therapies is hampered by the lack of appropriate animal models in which HF can be reliably determined, particularly in mice. The development of HF in mice is often assumed based on the presence of cardiac dysfunction, but HF itself is seldom proved. Lung ultrasound (LUS) has become a helpful tool for lung congestion assessment in patients at all stages of HF. We aimed to apply this non-invasive imaging tool to evaluate HF in mouse models of both systolic and diastolic dysfunction. METHODS AND RESULTS: We used LUS to study HF in a mouse model of systolic dysfunction, dilated cardiomyopathy, and in a mouse model of diastolic dysfunction, diabetic cardiomyopathy. LUS proved to be a reliable and reproducible tool to detect pulmonary congestion in mice. The combination of LUS and echocardiography allowed discriminating those mice that develop HF from those that do not, even in the presence of evident cardiac dysfunction. The study showed that LUS can be used to identify the onset of HF decompensation and to evaluate the efficacy of therapies for this syndrome. CONCLUSIONS: This novel approach in mouse models of cardiac disease enables for the first time to adequately diagnose HF non-invasively in mice with preserved or reduced ejection fraction, and will pave the way to a better understanding of HF and to the development of new therapeutic approaches.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatias Diabéticas/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Derrame Pleural/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Pesquisa Translacional Biomédica/métodos , Ultrassonografia/métodos , Função Ventricular Esquerda , Animais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatias Diabéticas/complicações , Cardiomiopatias Diabéticas/fisiopatologia , Diástole , Modelos Animais de Doenças , Ecocardiografia Doppler de Pulso , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Derrame Pleural/etiologia , Derrame Pleural/fisiopatologia , Valor Preditivo dos Testes , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Volume Sistólico , Sístole , Função Ventricular Direita
9.
J Cardiothorac Vasc Anesth ; 31(4): 1471-1480, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28465120

RESUMO

Tissue edema, in particular pulmonary edema, increasingly is recognized as a perioperative complication affecting outcome. Management strategies directed at avoiding excessive fluid administration, reducing inflammatory response, and decreasing capillary permeability commonly are advocated in perioperative care protocols. In this review, transpulmonary thermodilution (TPTD) as a bedside tool to quantitatively monitor lung water accumulation and optimize fluid therapy is examined. Furthermore, the roles of TPTD as an early detector of fluid accumulation before the development of overt pulmonary edema and in risk stratification are explored. In addition, the ability of TPTD to provide insight into the etiology of pulmonary edema, specifically differentiating hydrostatic versus increased pulmonary capillary permeability, is emerging as an aid in therapeutic decision-making. The combination of hemodynamic and lung water data afforded by TPTD offers unique benefits for the care of high-risk perioperative patients.


Assuntos
Água Extravascular Pulmonar/fisiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Hidratação/métodos , Humanos , Complicações Pós-Operatórias/etiologia , Edema Pulmonar/etiologia , Termodiluição/métodos
10.
BMC Infect Dis ; 17(1): 153, 2017 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-28212620

RESUMO

BACKGROUND: Enterovirus 71 (EV-A71) shows a potential of rapid death, but the natural history of the infection is poorly known. This study aimed to examine the natural history of EV-A71 infection. METHODS: This was a prospective longitudinal observational study performed between January 1st and October 31st, 2012, at three hospitals in Guangdong, China. Subjects with positive EV-A71 RNA laboratory test results were included. Disease progression was documented with MRI, autopsies, and follow-up. Symptoms/signs with potential association with risk of death were analyzed. RESULTS: Among the 288 patients, neurologic symptoms and signs were observed (emotional movement disorders, dyskinesia, involuntary movements, autonomic dysfunction, and disturbance of consciousness). Some of them occurred as initial symptoms. Myoclonic jerks/tremors were observed among >50% of the patients; nearly 40% of patients presented fatigue and 25% were with vomiting. Twenty-eight patients (9.7%) presented poor peripheral perfusion within 53.4 ± 26.1 h; 23 patients (8.0%) presented pulmonary edema and/or hemorrhage within 62.9 ± 28.6 h. Seventeen (5.9%) patients were in a coma. Seven (2.4%) patients died within 62.9 ± 28.6 h. Seventy-seven survivors underwent head and spinal cord MRI and 37.7% (29/77) showed abnormalities. Two fatal cases showed neuronal necrosis, softening, perivascular cuffing, colloid, and neuronophagia phenomenon in the brainstem. CONCLUSIONS: Patients with EV-A71 infection showed high complexity of symptoms and onset timing. Death risk may be indicated by autokinetic eyeball, eyeball ataxia, severe coma, respiratory rhythm abnormality, absent pharyngeal reflex, ultrahyperpyrexia, excessive tachycardia, pulmonary edema and/or hemorrhage, and refractory shock and ataxic respiration. Early assessment of these symptoms/signs is important for proper management.


Assuntos
Encefalite Viral/diagnóstico , Enterovirus Humano A/patogenicidade , Infecções por Enterovirus/diagnóstico , Infecções por Enterovirus/virologia , Hemorragia/diagnóstico , Edema Pulmonar/diagnóstico , Transtornos Respiratórios/diagnóstico , Autopsia , Criança , Pré-Escolar , China/epidemiologia , Coma , Surtos de Doenças , Progressão da Doença , Encefalite Viral/mortalidade , Encefalite Viral/fisiopatologia , Enterovirus Humano A/isolamento & purificação , Infecções por Enterovirus/mortalidade , Infecções por Enterovirus/fisiopatologia , Feminino , Hemorragia/mortalidade , Hemorragia/fisiopatologia , Humanos , Lactente , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Edema Pulmonar/mortalidade , Edema Pulmonar/fisiopatologia , Transtornos Respiratórios/mortalidade , Transtornos Respiratórios/fisiopatologia , Taxa Respiratória/fisiologia
12.
J Ultrasound Med ; 33(7): 1231-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24958410

RESUMO

OBJECTIVES: Bedside sonography has become a popular method of assessment of critically ill patients with shock and dyspnea. This study evaluated the usefulness of integrated cardiopulmonary sonography for assessment of acute pulmonary edema. METHODS: A total of 128 intensive care unit (ICU) patients with acute pulmonary edema were randomly divided into 2 groups: a sonography group, which received standard treatment as well as cardiopulmonary sonography, and a control group, which received standard treatment only. All patients were treated according to the same therapeutic strategies and underwent chest radiography and central venous catheter placement. Serum myocardial injury marker levels and central venous/arterial blood gas parameters were measured 0, 24, and 72 hours after enrollment. The cumulative fluid infusion volume at 6, 12, 24, and 72 hours, the time to diagnosis of the pulmonary edema etiology by the attending physician, the lengths of ICU and hospital stays, and ICU mortality were recorded. RESULTS: The sonography group had a shorter time to diagnosis and received a smaller fluid infusion volume than the control group. There were no significant differences in ICU mortality and lengths of ICU and hospital stays between the sonography and control groups. In patients with cardiogenic pulmonary edema, the sonography group had a significantly shorter ICU stay and a faster return to normal myocardial injury marker levels and perfusion parameters than the control group (P < .05). CONCLUSIONS: Integrated cardiopulmonary sonography resulted in faster and better-informed clinical decision making, shortened the time to diagnosis of the pulmonary edema etiology, and decreased fluid use. However, the impact of this examination on prognoses requires further study. We propose that integrated cardiopulmonary sonography may be a useful bedside tool for treatment of ICU patients with acute pulmonary edema.


Assuntos
Edema Pulmonar/diagnóstico por imagem , APACHE , Doença Aguda , Adulto , Cateterismo Venoso Central , Estado Terminal , Ecocardiografia , Humanos , Unidades de Terapia Intensiva , Ácido Láctico/sangue , Tempo de Internação , Pulmão/diagnóstico por imagem , Contração Miocárdica , Oxigênio/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Veia Cava Inferior/diagnóstico por imagem , Adulto Jovem
13.
J Appl Physiol (1985) ; 113(4): 666-76, 2012 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-22678969

RESUMO

Magnetic resonance elastography (MRE) is a MR imaging method capable of spatially resolving the intrinsic mechanical properties of normal lung parenchyma. We tested the hypothesis that the mechanical properties of edematous lung exhibit local properties similar to those of a fluid-filled lung at transpulmonary pressures (P(tp)) up to 25 cm H(2)O. Pulmonary edema was induced in anesthetized female adult Sprague-Dawley rats by mechanical ventilation to a pressure of 40 cm H(2)O for ≈ 30 min. Prior to imaging the wet weight of each ex vivo lung set was measured. MRE, high-resolution T(1)-weighted spin echo and T(2)* gradient echo data were acquired at each P(tp) for both normal and injured ex vivo lungs. At P(tp)s of 6 cm H(2)O and greater, the shear stiffness of normal lungs was greater than injured lungs (P ≤ 0.0003). For P(tp)s up to 12 cm H(2)O, shear stiffness was equal to 1.00, 1.07, 1.16, and 1.26 kPa for the injured and 1.31, 1.89, 2.41, and 2.93 kPa for normal lungs at 3, 6, 9, and 12 cm H(2)O, respectively. For injured lungs MRE magnitude signal and shear stiffness within regions of differing degrees of alveolar flooding were calculated as a function of P(tp). Differences in shear stiffness were statistically significant between groups (P < 0.001) with regions of lower magnitude signal being stiffer than those of higher signal. These data demonstrate that when the alveolar space filling material is fluid, MRE-derived parenchymal shear stiffness of the lung decreases, and the lung becomes inherently softer compared with normal lung.


Assuntos
Técnicas de Imagem por Elasticidade , Pulmão/patologia , Imageamento por Ressonância Magnética , Edema Pulmonar/patologia , Lesão Pulmonar Induzida por Ventilação Mecânica/patologia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Elasticidade , Feminino , Pulmão/fisiopatologia , Tamanho do Órgão , Valor Preditivo dos Testes , Pressão , Alvéolos Pulmonares/patologia , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Ratos , Ratos Sprague-Dawley , Respiração Artificial , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/fisiopatologia
14.
Am J Physiol Heart Circ Physiol ; 301(5): H2161-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21873499

RESUMO

Whether prolonged strenuous exercise performed by athletes at sea level can produce interstitial pulmonary edema is under debate. Chest sonography allows to estimate extravascular lung water, creating ultrasound lung comet-tail (ULC) artifacts. The aim of the study was to determine whether pulmonary water content increases in Ironmen (n = 31) during race at sea level and its correlation with cardiopulmonary function and systemic proinflammatory and cardiac biohumoral markers. A multiple factor analysis approach was used to determine the relations between systemic modifications and ULCs by assessing correlations among variables and groups of variables showing significant pre-post changes. All athletes were asymptomatic for cough and dyspnea at rest and after the race. Immediately after the race, a score of more than five comet tail artifacts, the threshold for a significant detection, was present in 23 athletes (74%; 16.3 ± 11.2; P < 0.01 ULC after the race vs. rest) but decreased 12 h after the end of the race (13 athletes; 42%; 6.3 ± 8.0; P < 0.01 vs. soon after the race). Multiple factor analysis showed significant correlations between ULCs and cardiac-related variables and NH(2)-terminal pro-brain natriuretic peptide. Healthy athletes developed subclinical increase in pulmonary water content immediately after an Ironman race at sea level, as shown by the increased number of ULCs related to cardiac changes occurring during exercise. Hemodynamic changes are one of several potential factors contributing to the mechanisms of ULCs.


Assuntos
Desempenho Atlético , Exercício Físico , Água Extravascular Pulmonar/metabolismo , Pulmão/diagnóstico por imagem , Edema Pulmonar/etiologia , Adulto , Artefatos , Doenças Assintomáticas , Ciclismo , Biomarcadores/sangue , Feminino , Hemodinâmica , Humanos , Mediadores da Inflamação/sangue , Pulmão/metabolismo , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Análise Multivariada , Valor Preditivo dos Testes , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/metabolismo , Edema Pulmonar/fisiopatologia , Respiração , Testes de Função Respiratória , Corrida , Natação , Fatores de Tempo , Ultrassonografia , Função Ventricular Esquerda
15.
Intensive Care Med ; 37(2): 249-56, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21136039

RESUMO

INTRODUCTION: Noninvasive pressure support ventilation (NIPSV) and continuous positive airway pressure (CPAP) are both advocated in the treatment of cardiogenic pulmonary edema (CPE); however, the superiority of one technique over the other has not been clearly demonstrated. With regard to its physiological effects, we hypothesized that NIPSV would be better than CPAP in terms of clinical benefit. METHODS: In a prospective, randomized, controlled study performed in four emergency departments, 200 patients were assigned to CPAP (n = 101) or NIPSV (n = 99). Primary outcome was combined events of hospital death and tracheal intubation. Secondary outcomes included resolution time, myocardial infarction rate, and length of hospital stay. Separate analysis was performed in patients with hypercapnia and those with high B-type natriuretic peptide (>500 pg/ml). RESULTS: Hospital death occurred in 5 (5.0%) patients receiving NIPSV and 3 (2.9%) patients receiving CPAP (p = 0.56). The need for intubation was observed in 6 (6%) patients in the NIPSV group and 4 (3.9%) patients in the CPAP group (p = 0.46). Combined events were similar in both groups. NIPSV was associated to a shorter resolution time compared to CPAP (159 ± 54 vs. 210 ± 73 min; p < 0.01), whereas the incidence of new myocardial infarction was not different between both groups. Similar results were found in hypercapnic patients and those with high B-type natriuretic peptide. CONCLUSIONS: During CPE, NIPSV accelerates the improvement of respiratory failure compared to CPAP but does not affect primary clinical outcome either in overall population or in subgroups of patients with hypercapnia or those with high B-type natriuretic peptide.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Serviço Hospitalar de Emergência , Respiração com Pressão Positiva , Edema Pulmonar/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hipertensão Pulmonar/complicações , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Oxigenoterapia/métodos , Estudos Prospectivos , Edema Pulmonar/economia , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Insuficiência Respiratória/terapia
16.
Artigo em Inglês | MEDLINE | ID: mdl-22254247

RESUMO

The aim of this work was to build up a new monitoring technique for the lung preservation. The medical aside problem is to measure the integrity and functionality of the lung tissue, specifically at cellular preservation level in order to improve the survival time until it is grafted. The Impedance monitoring technique for diagnosis edema development is the key in this new technique. The hypothesis was that lung edema formation is highly correlated with the reactance changes so that a rat lung perfusion model was considered as a good model to produce edema in vitro. To prove that pulmonary edema can be induced increasing the venous pressure and the perfusion time, the reactance and hemodynamic parameters were recorder in 16 pulmonary blocks of Wistar rats as methodology. Results showed statistical changes in each pulmonary block weight as a consequence to apply 7.5 ± 1.2 and 10.2 ± 1.7 mmHg venous pressure (multiple samples, Anova, p<0.05). These edema weights were correlated with the reactance changes giving 0.6 (p<0.05, Pearson). Also, data analysis showed significant differences in reactance with the time of perfusion at 16, 30, and 50 min when venous pressure level were intermittent switched from 7.5 to 10.2 mmHg. The conclusion was this preliminary evidence sustains that reactance measurement is a good technique for monitoring the lung edema level in rats. However, more research should be continuing in bigger animal models in order to prove the validity and application of this monitoring technique in human lungs.


Assuntos
Água Corporal/metabolismo , Pulmão/fisiopatologia , Técnicas de Cultura de Órgãos/instrumentação , Preservação de Órgãos/instrumentação , Pletismografia de Impedância/instrumentação , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Preservação de Órgãos/métodos , Perfusão/instrumentação , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água/análise
17.
Europace ; 12(5): 731-40, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20056595

RESUMO

AIMS: Heart failure patients are often equipped with implanted devices and are frequently hospitalized due to volume overload. Reliable prediction of imminent fluid congestion has the potential to provide early detection of cardiac decompensation and therefore might be capable of enhancing therapy management. We investigated whether implant-based impedance (Z) measurement is closely correlated with directly assessed extravascular lung water and might thus be useful for patient monitoring. METHODS AND RESULTS: In sheep, pulmonary fluid congestion was induced. Continuous haemodynamic monitoring was performed and extravascular lung water index (EVLWI) assessed. An implanted device with a right ventricular lead measured Z using different electrode configurations. All animals developed gradual pulmonary fluid accumulation leading to inclining lung oedema: EVLWI did increase from 9.5 +/- 1 to 21.1 +/- 5.1 mL/kg (+127%). A concomitant decrease of Z by up to 23%, depending on the electrode configuration, was observed and regression analysis between Z and EVLWI yielded a significant inverse correlation. CONCLUSION: Changes of Z show a strong inverse correlation with changes of directly measured EVLWI. This allows the application of Z as a measure of intrathoracic fluid status and has the potential to optimize patient care, especially in the context of evolving telemedicine concepts.


Assuntos
Cardiografia de Impedância/instrumentação , Água Extravascular Pulmonar/fisiologia , Insuficiência Cardíaca/fisiopatologia , Edema Pulmonar/diagnóstico , Edema Pulmonar/fisiopatologia , Animais , Débito Cardíaco/fisiologia , Dextranos/efeitos adversos , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Norepinefrina/efeitos adversos , Edema Pulmonar/induzido quimicamente , Pressão Propulsora Pulmonar/fisiologia , Análise de Regressão , Sensibilidade e Especificidade , Ovinos , Telemedicina/instrumentação
18.
Cardiovasc Ther ; 27(2): 89-95, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19426245

RESUMO

Optimizing responses to intravenous furosemide (ivF) in acute pulmonary edema is limited by current insensitive noninvasive means of volume assessment. We conducted a pilot study to assess the feasibility of performing repeated measures of echocardiographic and bioimpedance analysis (BIA) parameters and test their response as noninvasive markers of volume response to ivF. We also aimed to identify the most potentially sensitive markers of this response. Patients receiving ivF for a clinical diagnosis of acute cardiogenic pulmonary edema were studied. Echocardiographic and BIA parameters were measured at 0, 0.5, 1, 2, and 3 h after ivF. Intraobserver variability for each parameter was determined. Thirty-one patients were enrolled who were receiving 40-100 mg of ivF. Transmitral (MV) early peak velocity following Valsalva maneuver and transtricuspid (TV) early peak velocity reduced significantly (P= 0.012 and 0.010, respectively), whereas MV deceleration time increased significantly (P= 0.006) in response to ivF. Short-axis inferior vena cava diameter (SIVC) in expiration and inspiration and SIVC corrected for body surface area in expiration and inspiration reduced significantly following ivF (P= 0.039, 0.020, 0.032, and 0.016, respectively). BIA estimates of extracellular water decreased significantly (P= 0.001), whereas impedance (Z) at currents of 5, 50, 100, and 200 kHz increased following ivF; the changes were significant with all but the last parameter (P < 0.0001, 0.006, 0.010, and 0.051, respectively). Maximal change from baseline for each parameter was greater than its respective intraobserver variability. Performing repeated measures of echocardiographic and BIA parameters is feasible in this unstable group of patients. The above panel of parameters could potentially be used to track volume response to ivF and, thus, to optimize treatment in acute pulmonary edema.


Assuntos
Diurese/efeitos dos fármacos , Diuréticos/administração & dosagem , Monitoramento de Medicamentos/métodos , Ecocardiografia Doppler , Impedância Elétrica , Furosemida/administração & dosagem , Hemodinâmica/efeitos dos fármacos , Sistemas Automatizados de Assistência Junto ao Leito , Edema Pulmonar/tratamento farmacológico , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Composição Corporal , Estudos de Viabilidade , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
19.
Chest ; 135(6): 1433-1439, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19188552

RESUMO

BACKGROUND: Sonographic B-lines, also known as lung comets, have been shown to correlate with the presence of extravascular lung water (EVLW). Absent in normal lungs, these sonographic findings become prominent as interstitia and alveoli fill with fluid. Characterization of the dynamics of B-lines, specifically their rate of disappearance as volume is removed, has not been previously described. In this study, we describe the dynamics of B-line resolution in patients undergoing hemodialysis. METHODS: Patients undergoing hemodialysis underwent three chest ultrasound examinations: before, at the midpoint, and after dialysis. We followed a previously described chest ultrasound protocol that counts the number of B-lines visualized in 28 lung zones. Baseline demographics, assessment of ejection fraction, time elapsed, net volume of fluid removed, and subjective degree of shortness of breath were recorded for each patient. RESULTS: Forty of 45 patients completed full dialysis runs and had all three lung scans performed; 6 of 40 patients had zero or one B-line predialysis, and none of these 6 patients gained B-lines during dialysis. Thirty-four of 40 patients had statistically significant reductions in the number of B-lines from predialysis to the midpoint scan and from predialysis to postdialysis with a p value < 0.001. There was no association between subjective dyspnea scores and number of B-lines removed. CONCLUSIONS: B-line resolution appears to occur real-time as fluid is removed from the body, and this change was statistically significant. These data support thoracic ultrasound as a useful method for evaluating real-time changes in EVLW and in assessing a patient's physiologic response to the removal of fluid. TRIAL REGISTRATION: Massachusetts General Hospital trial registration protocol No. 2007P 002226.


Assuntos
Água Extravascular Pulmonar/diagnóstico por imagem , Falência Renal Crônica/terapia , Edema Pulmonar/diagnóstico por imagem , Diálise Renal/efeitos adversos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Humanos , Lactente , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Probabilidade , Estudos Prospectivos , Edema Pulmonar/etiologia , Edema Pulmonar/fisiopatologia , Diálise Renal/métodos , Reprodutibilidade dos Testes , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler , Adulto Jovem
20.
Am J Emerg Med ; 24(6): 658-63, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16984833

RESUMO

We sought to determine whether physicians' estimates of critically ill patients' hemodynamics are accurate as compared with esophageal Doppler probe (EDP) measurements and whether provision of measured hemodynamic profiles produces treatment changes and changes in physician confidence. At an urban county ED, we enrolled 55 critically ill adults with pulmonary edema of unclear etiology, sustained hypotension, or lactic acidosis. Physicians estimated cardiac output (CO) and systemic vascular resistance (SVR), categorized shock, stated treatment plans, and rated confidence in assessment and treatment plans. Physicians were informed of EDP hemodynamic measurements (CO, SVR, stroke volume, and contractility), and they repeated their assessments and plans. Weighted kappa values between physician estimates and EDP measurements of CO and SVR were 0.57 (95% confidence interval [CI] = 0.77-0.36) and 0.40 (95% CI = 0.64-0.16), respectively. Shock characterization changed in 52%, confidence increased significantly (pre-EDP mean = 3.3 +/- 0.9; post-EDP mean = 4.0 +/- 0.6; P = .0001), and stated treatment plans changed in 68% of the patients. Chart review demonstrated that similar proportions of control subjects had treatment changes, with a mean difference of 20% (95% CI = -2 to 42). Physician assessments of hemodynamic variables were moderately accurate. We conclude that EDP hemodynamic profiles change assessments and increase confidence in assessments but may not alter treatment.


Assuntos
Débito Cardíaco Elevado/diagnóstico por imagem , Baixo Débito Cardíaco/diagnóstico por imagem , Fenômenos Fisiológicos Cardiovasculares , Estado Terminal , Serviço Hospitalar de Emergência , Endossonografia , Acidose Láctica/fisiopatologia , Idoso , Esôfago , Feminino , Hospitais Urbanos , Humanos , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Edema Pulmonar/fisiopatologia , Choque/fisiopatologia , Estatísticas não Paramétricas , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA