Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 691
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Membr Biol ; 256(3): 271-285, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37140614

RESUMO

The main objective of the present study was to find detergents that can maintain the functionality and stability of the Torpedo californica nicotinic acetylcholine receptor (Tc-nAChR). We examined the functionality, stability, and purity analysis of affinity-purified Tc-nAChR solubilized in detergents from the Cyclofos (CF) family [cyclofoscholine 4 (CF-4), cyclofoscholine 6 (CF-6), and cyclofloscholine 7 (CF-7)]. The functionality of the CF-Tc-nAChR-detergent complex (DC) was evaluated using the Two Electrode Voltage Clamp (TEVC) method. To assess stability, we used the florescence recovery after photobleaching (FRAP) in Lipidic Cubic Phase (LCP) methodology. We also performed a lipidomic analysis using Ultra-Performance Liquid Chromatography (UPLC) coupled to electrospray ionization mass spectrometry (ESI-MS/MS) to evaluate the lipid composition of the CF-Tc-nAChR-DCs. The CF-4-Tc-nAChR-DC displayed a robust macroscopic current (- 200 ± 60 nA); however, the CF-6-Tc-nAChR-DC and CF-7-Tc-nAChR-DC displayed significant reductions in the macroscopic currents. The CF-6-Tc-nAChR and CF-4-Tc-nAChR displayed higher fractional florescence recovery. Addition of cholesterol produced a mild enhancement of the mobile fraction on the CF-6-Tc-nAChR. The lipidomic analysis revealed that the CF-7-Tc-nAChR-DC displayed substantial delipidation, consistent with the lack of stability and functional response of this complex. Although the CF-6-nAChR-DC complex retained the largest amount of lipids, it showed a loss of six lipid species [SM(d16:1/18:0); PC(18:2/14:1); PC(14:0/18:1); PC(16:0/18:1); PC(20:5/20:4), and PC(20:4/20:5)] that are present in the CF-4-nAChR-DC. Overall, the CF-4-nAChR displayed robust functionality, significant stability, and the best purity among the three CF detergents; therefore, CF-4 is a suitable candidate to prepare Tc-nAChR crystals for structural studies.


Assuntos
Detergentes , Receptores Nicotínicos , Animais , Espectrometria de Massas em Tandem , Torpedo , Receptores Nicotínicos/química , Lipídeos/química , Eletrofisiologia
2.
Doc Ophthalmol ; 146(2): 151-163, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36617339

RESUMO

INTRODUCTION: Visual electrophysiology tests require the use of precise and calibrated visual display units (VDUs). Existing VDUs for presenting structured stimuli are now mostly obsolete, with modern solutions limited or unsuitable for clinical testing. Digital light processing (DLP) laser projectors have recently become commercially available and this study aimed to assess their suitability as VDUs for visual electrophysiology testing. METHODS: This study consisted of two sections. The first was a photometric study of two DLP laser projectors (Viewsonic LS831WU and HiSense 100L5FTUK) to assess luminance, contrast, spectral and temporal characteristics of the stimulus. The second was a physiological study comparing pattern electroretinograms (PERG) and visual evoked potentials (PVEPs) amplitudes and peak-times recorded using a DLP laser projector, photometrically and spatially matched to existing plasma VDUs at our institution (Pioneer Electronics Corporation, PDP422MXE). RESULTS: The Viewsonic DLP laser projector was capable of high luminance levels (0-587.5 cd/m2) whilst maintaining contrast above 93%. The temporal properties showed fast rise and fall times of 0.5-1 ms and 0.5-1 ms, respectively, without any transient luminance change with reversals. The device required a warm-up time of at least 2 min until reaching near maximal luminance. The second (Hisense) device was observed to have a detrimental input lag jitter so was not used for any further analysis. PERGs and PVEPs showed high agreement and correlation (r = 0.766-0.905) between the Viewsonic DLP device and existing plasma VDUs. No significant differences were observed for P50 and P100 peak-time (p = > 0.05), however P50, N95 and P100 amplitudes were all significantly larger for the DLP device (p = < 0.05). DISCUSSION: The DLP laser projector tested in this study is a viable and practical replacement VDU for clinical electrophysiology tests of vision. The device is easily capable of meeting ISCEV standards, and showed PERG and PVEP amplitudes larger than existing systems despite photometric and spatial matching. The DLP laser projectors are capable of very large field sizes so are beneficial for paediatric testing or those wishing to examine large field responses. Importantly, it was observed that some devices may suffer input lag jitter, therefore, individual calibration and assessment of DLP projection systems is an important consideration before clinical implementation.


Assuntos
Eletrorretinografia , Potenciais Evocados Visuais , Humanos , Criança , Visão Ocular , Luz , Eletrofisiologia
3.
Radiat Environ Biophys ; 61(2): 293-300, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35218403

RESUMO

A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator's exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p < 0.05) and at least 15 times (p < 0.05) higher for the eye lenses and thoracic region, respectively, compared to CSS (with dosimeters on the apron/collar). However, when only ZG was used slightly higher normalised doses were observed for the left finger compared to CSS (5.88e - 2 Sv/Gym2 vs. 4.31 e - 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.


Assuntos
Exposição Ocupacional , Intervenção Coronária Percutânea , Médicos , Eletrofisiologia , Hemodinâmica , Humanos , Exposição Ocupacional/análise , Doses de Radiação
4.
Nat Med ; 27(12): 2154-2164, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34887577

RESUMO

Detection of neural signatures related to pathological behavioral states could enable adaptive deep brain stimulation (DBS), a potential strategy for improving efficacy of DBS for neurological and psychiatric disorders. This approach requires identifying neural biomarkers of relevant behavioral states, a task best performed in ecologically valid environments. Here, in human participants with obsessive-compulsive disorder (OCD) implanted with recording-capable DBS devices, we synchronized chronic ventral striatum local field potentials with relevant, disease-specific behaviors. We captured over 1,000 h of local field potentials in the clinic and at home during unstructured activity, as well as during DBS and exposure therapy. The wide range of symptom severity over which the data were captured allowed us to identify candidate neural biomarkers of OCD symptom intensity. This work demonstrates the feasibility and utility of capturing chronic intracranial electrophysiology during daily symptom fluctuations to enable neural biomarker identification, a prerequisite for future development of adaptive DBS for OCD and other psychiatric disorders.


Assuntos
Eletrofisiologia/métodos , Transtorno Obsessivo-Compulsivo/fisiopatologia , Adulto , Biomarcadores/metabolismo , Eletrodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estriado Ventral/fisiologia
5.
Int J Pediatr Otorhinolaryngol ; 151: 110962, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34736007

RESUMO

OBJECTIVE: Children with auditory processing disorder (APD) are reported to have abnormal auditory brainstem responses (ABR) but little is understood about their cochlear integrity. Poor cochlear integrity can affect neural responses. In this study, cochlear and auditory brainstem integrity was investigated in children with APD. METHOD: Twenty children with APD, sixteen typically developing children and twenty adults participated in this study. Click evoked electrocochleography (ECochG) and ABRs were recorded from all the participants. Cochlear responses were analyzed using a) latency and amplitude of summating potential; action potential, b) transmission time between summating potential and action potential, c) summating potential/action potential amplitude ratio and d) action potential latency difference to condensation and rarefaction polarity. Amplitude in the ABR components was examined. RESULTS: Children with APD showed similar cochlear function to the typically developing children. There were no significant differences in wave I amplitude between children with APD and typically developing children. However, wave V amplitude was significantly reduced in children with APD compared to typically developing children. CONCLUSION: In the absence of any functional differences in the cochlea, children with APD can show poor amplitude in the later components of the ABR. The ABR anomalies observed in children with APD arise due to poor neural processing, possibly after the first auditory synapse.


Assuntos
Transtornos da Percepção Auditiva , Estimulação Acústica , Adulto , Audiometria de Resposta Evocada , Limiar Auditivo , Criança , Cóclea , Eletrofisiologia , Potenciais Evocados Auditivos do Tronco Encefálico , Humanos
6.
Eye (Lond) ; 35(9): 2344-2353, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34290445

RESUMO

Visual disturbance or visual failure due to toxicity of an ingested substance or a severe nutritional deficiency can present significant challenges for diagnosis and management, for instance, where an adverse reaction to a prescribed medicine is suspected. Objective assessment of visual function is important, particularly where structural changes in the retina or optic nerve have not yet occurred, as there may be a window of opportunity to mitigate or reverse visual loss. This paper reviews a number of clinical presentations where visual electrophysiological assessment has an important role in early diagnosis or management alongside clinical assessment and ocular imaging modalities. We highlight the importance of vitamin A deficiency as an easily detected marker for severe combined micronutrient deficiency.


Assuntos
Eletrorretinografia , Doenças do Nervo Óptico , Eletrofisiologia , Humanos , Doenças do Nervo Óptico/diagnóstico , Retina/diagnóstico por imagem , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia
7.
Cortex ; 142: 296-316, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34332197

RESUMO

There is an apparent disparity between the fields of cognitive audiology and cognitive electrophysiology as to how linguistic context is used when listening to perceptually challenging speech. To gain a clearer picture of how listening effort impacts context use, we conducted a pre-registered study to simultaneously examine electrophysiological, pupillometric, and behavioral responses when listening to sentences varying in contextual constraint and acoustic challenge in the same sample. Participants (N = 44) listened to sentences that were highly constraining and completed with expected or unexpected sentence-final words ("The prisoners were planning their escape/party") or were low-constraint sentences with unexpected sentence-final words ("All day she thought about the party"). Sentences were presented either in quiet or with +3 dB SNR background noise. Pupillometry and EEG were simultaneously recorded and subsequent sentence recognition and word recall were measured. While the N400 expectancy effect was diminished by noise, suggesting impaired real-time context use, we simultaneously observed a beneficial effect of constraint on subsequent recognition memory for degraded speech. Importantly, analyses of trial-to-trial coupling between pupil dilation and N400 amplitude showed that when participants' showed increased listening effort (i.e., greater pupil dilation), there was a subsequent recovery of the N400 effect, but at the same time, higher effort was related to poorer subsequent sentence recognition and word recall. Collectively, these findings suggest divergent effects of acoustic challenge and listening effort on context use: while noise impairs the rapid use of context to facilitate lexical semantic processing in general, this negative effect is attenuated when listeners show increased effort in response to noise. However, this effort-induced reliance on context for online word processing comes at the cost of poorer subsequent memory.


Assuntos
Eletroencefalografia , Percepção da Fala , Eletrofisiologia , Potenciais Evocados , Feminino , Humanos , Masculino , Ruído
8.
Laryngoscope ; 131(9): 2098-2105, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34013983

RESUMO

OBJECTIVES: Assesses whether preoperative functional testing can distinguish vestibular schwannomas from facial nerve schwannomas medial to the labyrinthine segment. STUDY DESIGN: Retrospective cohort. METHODS: Retrospectively review surgically managed intracranial facial and vestibular schwannomas between January 2015 and December 2019 at two tertiary care centers. Patients with neurofibromatosis 2 and surgery for recurrence were excluded. Preoperative functional testing to include House-Brackmann scores, electroneuronography (ENoG), cervical vestibular evoked myogenic potentials (cVEMP), caloric testing, acoustic brainstem responses (ABRs), acoustic reflexes, and audiograms was compared between the two groups of schwannomas. RESULTS: Twelve facial and 128 vestibular schwannomas met inclusion criteria. In only one case was a facial schwannoma diagnosed preoperatively from imaging. No statistically significant difference was found in preoperative House-Brackmann scores, ENoG, cVEMP, caloric testing, ABRs, or acoustic reflexes. Pure tone average was worse in the vestibular schwannoma group (63 dB [95% CI: 58-68 dB] vs. 46 dB [95% CI: 34-58 dB], P = .01), and the difference was more apparent in the lower frequencies. Word recognition score was better in the facial schwannoma group (66% [95% CI: 45-86%] vs. 41% [95% CI: 34-47%], P = .02). CONCLUSION: Specialized preoperative functional evaluation of the nerves of the internal auditory canal cannot reliably predict the presence of an intracranial facial schwannoma. Hearing is better in facial schwannomas, particularly in the lower frequencies. This should raise the index of suspicion for an intracranial facial schwannoma, especially in candidates for hearing preservation vestibular schwannoma surgery. LEVEL OF EVIDENCE: 3 Laryngoscope, 131:2098-2105, 2021.


Assuntos
Neoplasias dos Nervos Cranianos/patologia , Orelha Interna/inervação , Nervo Facial/patologia , Neurilemoma/diagnóstico , Neuroma Acústico/diagnóstico , Adulto , Idoso , Audiometria de Tons Puros/métodos , Testes Calóricos/métodos , Estudos de Casos e Controles , Diagnóstico Diferencial , Orelha Interna/fisiologia , Eletrofisiologia/métodos , Nervo Facial/fisiopatologia , Feminino , Audição/fisiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neurilemoma/cirurgia , Neuroma Acústico/cirurgia , Cuidados Pré-Operatórios/estatística & dados numéricos , Estudos Retrospectivos , Potenciais Evocados Miogênicos Vestibulares/fisiologia
9.
Nat Commun ; 12(1): 2605, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33972521

RESUMO

Brain-body interactions are thought to be essential in emotions but their physiological basis remains poorly understood. In mice, regular 4 Hz breathing appears during freezing after cue-fear conditioning. Here we show that the olfactory bulb (OB) transmits this rhythm to the dorsomedial prefrontal cortex (dmPFC) where it organizes neural activity. Reduction of the respiratory-related 4 Hz oscillation, via bulbectomy or optogenetic perturbation of the OB, reduces freezing. Behavioural modelling shows that this is due to a specific reduction in freezing maintenance without impacting its initiation, thus dissociating these two phenomena. dmPFC LFP and firing patterns support the region's specific function in freezing maintenance. In particular, population analysis reveals that network activity tracks 4 Hz power dynamics during freezing and reaches a stable state at 4 Hz peak that lasts until freezing termination. These results provide a potential mechanism and a functional role for bodily feedback in emotions and therefore shed light on the historical James-Cannon debate.


Assuntos
Medo/fisiologia , Bulbo Olfatório/fisiologia , Córtex Pré-Frontal/fisiologia , Respiração , Potenciais de Ação/fisiologia , Animais , Antitireóideos/administração & dosagem , Antitireóideos/farmacologia , Eletrofisiologia , Interneurônios/citologia , Interneurônios/fisiologia , Masculino , Cadeias de Markov , Metimazol/administração & dosagem , Metimazol/farmacologia , Camundongos , Camundongos Endogâmicos C57BL , Modelos Psicológicos , Optogenética , Periodicidade , Células Piramidais/citologia , Células Piramidais/fisiologia , Respiração/efeitos dos fármacos
10.
J Econ Entomol ; 114(2): 652-675, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33704447

RESUMO

Monitoring is critical to control efforts for Drosophila suzukii Matsumura, an invasive polyphagous fly that has the potential to cause significant losses in commercial soft fruit and berry production worldwide. We used an iterative process to identify trap colors, trap designs, and volatile mixtures to improve monitoring efforts in commercial blueberry, raspberry, and blackberry crops. Our results suggest that the selection of trap color and design and attractant lures should be customized to the crop in which they are deployed. In raspberries grown in high tunnel systems, DrosaLure paired with Drosal traps painted green and purple were highly specific to D. suzukii although actual capture counts were low. However, in field grown raspberries, BioLure and Multilure traps were most effective, but with significant nontarget bycatch. In blueberries, we had greatest success with a 5 µg:50 ng mixture of ethyl acetate-acetoin in a green/purple-colored jar-style trap with large (5 cm) mesh covered openings.


Assuntos
Mirtilos Azuis (Planta) , Drosophila , Animais , Eletrofisiologia , Frutas , Controle de Insetos , Laboratórios
11.
Ir J Med Sci ; 190(1): 79-87, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32514660

RESUMO

BACKGROUND: Electroanatomical mapping systems (EMS) reduce fluoroscopy dose for the ablation. Higher costs and longer procedure times are the drawbacks associated with EMS. Our objective was to validate the efficiency of the EMS. OBJECTIVE: To demonstrate that using EMS is more efficient and as secure as the traditional system of ablation. METHODS: From April 2013 to June 2018, all patients were included into two groups, according to the intention of ablation with or without fluoroscopy. Right, left, supraventricular and ventricular ablation were included. We compared procedure variables (fluoroscopy, radiofrequency and procedure times, ablation results, complication rates and costs of the procedure) that included material and detrimental effect of fluoroscopy. RESULTS: A total of 105 were included in the fluoroscopy group and 287 in the without fluoroscopy group. We found an important reduction in time and radiation dose in all the ablation procedures studied, without increasing the procedure time. No differences in ablation results nor complications rate were found. We found lower costs in the flutter ablation without fluoroscopy, similar costs in the right focal tachycardia ablation group and higher costs in the without fluoroscopy group for the AVNRT and left accessory pathway. When detrimental effect of fluoroscopy was added, all procedures without fluoroscopy were significantly more efficient than the ones performed with it. CONCLUSIONS: Ablation without fluoroscopy is a technique as safe and effective as the conventional technique. Our study suggests that the radiation dose delivered to the patient and staff might be reduced, without increasing the total procedure time, being even more efficient.


Assuntos
Ablação por Cateter/métodos , Eletrofisiologia/métodos , Fluoroscopia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
Sci Rep ; 10(1): 21770, 2020 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-33303857

RESUMO

Despite the availability of various clinical trials that used different diagnostic methods to identify diabetic sensorimotor polyneuropathy (DSPN), no reliable studies that prove the associations among diagnostic parameters from two different methods are available. Statistically significant diagnostic parameters from various methods can help determine if two different methods can be incorporated together for diagnosing DSPN. In this study, a systematic review, meta-analysis, and trial sequential analysis (TSA) were performed to determine the associations among the different parameters from the most commonly used electrophysiological screening methods in clinical research for DSPN, namely, nerve conduction study (NCS), corneal confocal microscopy (CCM), and electromyography (EMG), for different experimental groups. Electronic databases (e.g., Web of Science, PubMed, and Google Scholar) were searched systematically for articles reporting different screening tools for diabetic peripheral neuropathy. A total of 22 studies involving 2394 participants (801 patients with DSPN, 702 controls, and 891 non-DSPN patients) were reviewed systematically. Meta-analysis was performed to determine statistical significance of difference among four NCS parameters, i.e., peroneal motor nerve conduction velocity, peroneal motor nerve amplitude, sural sensory nerve conduction velocity, and sural sensory nerve amplitude (all p < 0.001); among three CCM parameters, including nerve fiber density, nerve branch density, and nerve fiber length (all p < 0.001); and among four EMG parameters, namely, time to peak occurrence (from 0 to 100% of the stance phase) of four lower limb muscles, including the vastus lateralis (p < 0.001), tibialis anterior (p = 0.63), lateral gastrocnemius (p = 0.01), and gastrocnemius medialis (p = 0.004), and the vibration perception threshold (p < 0.001). Moreover, TSA was conducted to estimate the robustness of the meta-analysis. Most of the parameters showed statistical significance between each other, whereas some were statistically nonsignificant. This meta-analysis and TSA concluded that studies including NCS and CCM parameters were conclusive and robust. However, the included studies on EMG were inconclusive, and additional clinical trials are required.


Assuntos
Neuropatias Diabéticas/diagnóstico , Eletrofisiologia/métodos , Condução Nervosa , Adulto , Idoso , Neuropatias Diabéticas/fisiopatologia , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nervo Fibular/fisiopatologia , Nervo Sural/fisiopatologia
13.
J R Soc Interface ; 17(171): 20200532, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33109017

RESUMO

Modelling the cardiac electrophysiology entails dealing with the uncertainties related to the input parameters such as the heart geometry and the electrical conductivities of the tissues, thus calling for an uncertainty quantification (UQ) of the results. Since the chambers of the heart have different shapes and tissues, in order to make the problem affordable, here we focus on the left ventricle with the aim of identifying which of the uncertain inputs mostly affect its electrophysiology. In a first phase, the uncertainty of the input parameters is evaluated using data available from the literature and the output quantities of interest (QoIs) of the problem are defined. According to the polynomial chaos expansion, a training dataset is then created by sampling the parameter space using a quasi-Monte Carlo method whereas a smaller independent dataset is used for the validation of the resulting metamodel. The latter is exploited to run a global sensitivity analysis with nonlinear variance-based indices and thus reduce the input parameter space accordingly. Thereafter, the uncertainty probability distribution of the QoIs are evaluated using a direct UQ strategy on a larger dataset and the results discussed in the light of the medical knowledge.


Assuntos
Algoritmos , Ventrículos do Coração , Eletrofisiologia , Método de Monte Carlo , Incerteza
14.
Eur Biophys J ; 49(7): 591-607, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32940715

RESUMO

GABA and glycine act as inhibitory neurotransmitters in the CNS. Inhibitory neurotransmission is mediated via activation of ionotropic GABAA and glycine receptors. We used a modeling approach to explain the opposite effects of the general anesthetic etomidate (ETM) and fenamate mefenamic acid (MFA) on GABA- and glycine-activated currents recorded in isolated cerebellar Purkinje cells and hippocampal pyramidal neurons, respectively. These drugs potentiated GABAARs but blocked GlyRs. We built a homology model of α1ß GlyR based on the cryo-EM structure of open α1 GlyR, used the α1ß3γ2 GABAAR structure from the PDB, and applied Monte-Carlo energy minimization to optimize models of receptors and ligand-receptor complexes. In silico docking suggests that ETM/MFA bind at the transmembrane ß( +)/α( -) intersubunit interface in GABAAR. Our models predict that the bulky side chain of the highly conserved Arg19' residue at the plus interface side wedges the interface and maintains the conducting receptor state. We hypothesized that MFA/ETM binding at the ß( +)/α( -) interface leads to prolongation of receptor life-time in the open state. Having analyzed different GABAAR and GlyR structures available in the PDB, we found that mutual arrangement of the Arg19' and Gln-26' side chains at the plus and minus interface sides, respectively, plays an important role when the receptor switches from the open to closed state. We show that this process is accompanied by narrowing of the intersubunit interfaces, leading to extrusion of the Arg19' side chain from the interface. Our models allow us to explain the lack of GlyR potentiation in our electrophysiological experiments.


Assuntos
Etomidato/química , Ácido Mefenâmico/química , Neurônios/metabolismo , Proteínas Nucleares/química , Oxirredutases/química , Receptores de GABA-A/química , Anestésicos Gerais/farmacologia , Animais , Sítios de Ligação , Simulação por Computador , Bases de Dados de Proteínas , Eletrofisiologia , Fenamatos/química , Glicina/química , Ligantes , Conformação Molecular , Simulação de Acoplamento Molecular , Método de Monte Carlo , Ligação Proteica , Ratos , Ratos Wistar , Receptores de Glicina/química , Transmissão Sináptica
15.
J Healthc Eng ; 2020: 8828006, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32908658

RESUMO

Aim: The aim of this study was to evaluate the electrical activity of the masticatory muscles in children with a bilateral complete cleft lip and palate (BCCLP) and posterior crossbite as well as in noncleft subjects with no malocclusion. Another purpose of the study was to examine the possible factors associated with this muscle activity. Methods: The study included 52 children with mixed dentition and Class I occlusions (20 patients with nonsyndromic BCCLP and 32 subjects with no clefts). All the cleft patients had posterior crossbite. The surface electromyography (sEMG) was used to identify the electrical potentials of the temporalis and masseter muscles. The electromyographical (EMG) recordings were taken with a DAB-Bluetooth Instrument (zebris Medical GmbH, Germany) at rest and during maximum voluntary clenching (MVC). The relationships between muscle EMG activity and independent variables were identified through multivariate logistic regression analysis. Results: The EMG activity of the temporalis muscles at rest was significantly higher in BCCLP patients with malocclusion in comparison with the noncleft subjects with normal occlusion. During MVC, significantly lower electrical potentials of the temporalis and masseter muscles were observed in cleft patients compared to the noncleft group. The presence of BCCLP, unilateral posterior crossbites, increased vertical overlap, and increased overjet are factors strongly associated with higher temporalis muscle EMG activity at rest. Conclusion: The use of surface electromyography in imaging muscle function showed that children with BCCLP and posterior crossbite exhibited altered masticatory muscle potentials at rest and during clenching. The presence of unilateral posterior crossbites, increased vertical overlap, and increased overjet had a significant impact on temporalis muscle activity in cleft patients. This knowledge is important in the aspect of early and proper diagnosis and orthodontic treatment of malocclusions, thereby achieving correct occlusion and improvement in muscle function.


Assuntos
Fenda Labial/fisiopatologia , Fissura Palatina/fisiopatologia , Eletromiografia/métodos , Má Oclusão/fisiopatologia , Criança , Eletrofisiologia , Feminino , Humanos , Masculino , Músculo Masseter/fisiopatologia , Análise Multivariada , Contração Muscular/fisiologia , Ortodontia , Palato/fisiopatologia , Músculo Temporal/fisiopatologia
16.
Nat Commun ; 11(1): 2128, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32358494

RESUMO

Attention enhances the neural representations of behaviorally relevant stimuli, typically by a push-pull increase of the neuronal response gain to attended vs. unattended stimuli. This selectively improves perception and consequently behavioral performance. However, to enhance the detectability of stimulus changes, attention might also distort neural representations, compromising accurate stimulus representation. We test this hypothesis by recording neural responses in the visual cortex of rhesus monkeys during a motion direction change detection task. We find that attention indeed amplifies the neural representation of direction changes, beyond a similar effect of adaptation. We further show that humans overestimate such direction changes, providing a perceptual correlate of our neurophysiological observations. Our results demonstrate that attention distorts the neural representations of abrupt sensory changes and consequently perceptual accuracy. This likely represents an evolutionary adaptive mechanism that allows sensory systems to flexibly forgo accurate representation of stimulus features to improve the encoding of stimulus change.


Assuntos
Atenção/fisiologia , Eletrofisiologia , Percepção Visual/fisiologia , Adulto , Animais , Feminino , Humanos , Macaca mulatta , Masculino , Neurônios/citologia , Neurônios/metabolismo , Córtex Visual/fisiologia , Adulto Jovem
17.
J Vis Exp ; (157)2020 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-32202521

RESUMO

Over the past two decades, optogenetic tools have been established as potent means to modulate cell-type specific activity in excitable tissues, including the heart. While Channelrhodopsin-2 (ChR2) is a common tool to depolarize the membrane potential in cardiomyocytes (CM), potentially eliciting action potentials (AP), an effective tool for reliable silencing of CM activity has been missing. It has been suggested to use anion channelrhodopsins (ACR) for optogenetic inhibition. Here, we describe a protocol to assess the effects of activating the natural ACR GtACR1 from Guillardia theta in cultured rabbit CM. Primary readouts are electrophysiological patch-clamp recordings and optical tracking of CM contractions, both performed while applying different patterns of light stimulation. The protocol includes CM isolation from rabbit heart, seeding and culturing of the cells for up to 4 days, transduction via adenovirus coding for the light-gated chloride channel, preparation of patch-clamp and carbon fiber setups, data collection and analysis. Using the patch-clamp technique in whole-cell configuration allows one to record light-activated currents (in voltage-clamp mode, V-clamp) and AP (current-clamp mode, I-clamp) in real time. In addition to patch-clamp experiments, we conduct contractility measurements for functional assessment of CM activity without disturbing the intracellular milieu. To do so, cells are mechanically preloaded using carbon fibers and contractions are recorded by tracking changes in sarcomere length and carbon fiber distance. Data analysis includes assessment of AP duration from I-clamp recordings, peak currents from V-clamp recordings and force calculation from carbon fiber measurements. The described protocol can be applied to the testing of biophysical effects of different optogenetic actuators on CM activity, a prerequisite for the development of a mechanistic understanding of optogenetic experiments in cardiac tissue and whole hearts.


Assuntos
Eletrofisiologia/métodos , Miócitos Cardíacos/citologia , Optogenética , Potenciais de Ação , Animais , Calibragem , Fibra de Carbono , Separação Celular , Células Cultivadas , Channelrhodopsins/metabolismo , Meios de Cultura , Análise de Dados , Luz , Contração Miocárdica , Técnicas de Patch-Clamp , Perfusão , Coelhos
18.
Nat Commun ; 11(1): 1172, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32127543

RESUMO

von Economo neurons (VENs) are bipolar, spindle-shaped neurons restricted to layer 5 of human frontoinsula and anterior cingulate cortex that appear to be selectively vulnerable to neuropsychiatric and neurodegenerative diseases, although little is known about other VEN cellular phenotypes. Single nucleus RNA-sequencing of frontoinsula layer 5 identifies a transcriptomically-defined cell cluster that contained VENs, but also fork cells and a subset of pyramidal neurons. Cross-species alignment of this cell cluster with a well-annotated mouse classification shows strong homology to extratelencephalic (ET) excitatory neurons that project to subcerebral targets. This cluster also shows strong homology to a putative ET cluster in human temporal cortex, but with a strikingly specific regional signature. Together these results suggest that VENs are a regionally distinctive type of ET neuron. Additionally, we describe the first patch clamp recordings of VENs from neurosurgically-resected tissue that show distinctive intrinsic membrane properties relative to neighboring pyramidal neurons.


Assuntos
Neurônios/fisiologia , Lobo Temporal/citologia , Transcriptoma , Animais , Encéfalo/citologia , Encéfalo/fisiologia , Eletrofisiologia/métodos , Perfilação da Expressão Gênica , Humanos , Hibridização in Situ Fluorescente , Camundongos , Neurônios/citologia , Células Piramidais/fisiologia , Telencéfalo/citologia , Lobo Temporal/fisiologia
19.
Int J Numer Method Biomed Eng ; 36(2): e3296, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31833669

RESUMO

Minimal mathematical models were developed to describe the electrophysiological properties of human δ-cells. Markov models of single channels were first developed based on the analysis of electrophysiological data. Monte Carlo simulations of voltage-clamp experiments were performed in an iteratively optimization procedure to estimate the number of channels required to reproduce the main characteristics of the macroscopic currents recorded experimentally. A membrane model of the firing of action potentials was then developed based on the kinetic schemes of single channels and the number of channels estimated. We showed that macroscopic currents of human δ-cells can be reproduced by minimal models of single channels when the appropriate number of channels is considered. In addition, our simulations suggest that human δ-cells are capable of generating action potentials through the interaction of the ionic currents involved. Finally, we determined the relative contribution of the currents underlying the firing of action potentials in human pancreatic δ-cells, which allowed us to propose a qualitative model of an action potential in terms of the underlying ionic currents.


Assuntos
Células Secretoras de Insulina/metabolismo , Modelos Teóricos , Potenciais de Ação/fisiologia , Eletrofisiologia , Humanos , Potenciais da Membrana/fisiologia , Método de Monte Carlo
20.
Brain Topogr ; 32(6): 1020-1034, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31754933

RESUMO

Electrophysiological recordings of neuronal activity show spontaneous and task-dependent changes in their frequency-domain power spectra. These changes are conventionally interpreted as modulations in the amplitude of underlying oscillations. However, this overlooks the possibility of underlying transient spectral 'bursts' or events whose dynamics can map to changes in trial-average spectral power in numerous ways. Under this emerging perspective, a key challenge is to perform burst detection, i.e. to characterise single-trial transient spectral events, in a principled manner. Here, we describe how transient spectral events can be operationalised and estimated using Hidden Markov Models (HMMs). The HMM overcomes a number of the limitations of the standard amplitude-thresholding approach to burst detection; in that it is able to concurrently detect different types of bursts, each with distinct spectral content, without the need to predefine frequency bands of interest, and does so with less dependence on a priori threshold specification. We describe how the HMM can be used for burst detection and illustrate its benefits on simulated data. Finally, we apply this method to empirical data to detect multiple burst types in a task-MEG dataset, and illustrate how we can compute burst metrics, such as the task-evoked timecourse of burst duration.


Assuntos
Eletrofisiologia/métodos , Neurônios/fisiologia , Fenômenos Eletrofisiológicos , Humanos , Cadeias de Markov , Modelos Neurológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA