Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Electrophoresis ; 40(9): 1322-1330, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30657598

RESUMO

The fabrication of PDMS microfluidic structures through soft lithography is widely reported. While this well-established method gives high precision microstructures and has been successfully used for many researchers, it often requires sophisticated instrumentation and expensive materials such as clean room facilities and photoresists. Thus, we present here a simple protocol that allows the rapid molding of simple linear microchannels in PDMS substrates aiming microfluidics-based applications. It might serve as an alternative to researchers that do not have access to sophisticated facilities such as clean rooms. The method developed here consists on the use of pencil graphite leads as template for the molding of PDMS channels. It yields structures that can be used for several applications, such as housing support for electrochemical sensors or channels for flow devices. Here, the microdevices produced through this protocol were employed for the accommodation of carbon black paste, which was utilized for the first time as amperometric sensor in microchip electrophoresis. This platform was successfully used for the separation and detection of model analytes. Ascorbic acid and iodide were separated within 45 s with peak resolution of 1.2 and sensitivities of 198 and 492 pA/µM, respectively. The background noise was ca. 84 pA. The analytical usefulness of the system developed was successfully tested through the quantification of iodide in commercial pharmaceutical formulations. It demonstrates good efficiency of the microfabrication protocol developed and enables its use for the easy and rapid prototyping of PDMS structures over a low fabrication cost.


Assuntos
Microfluídica/instrumentação , Dimetilpolisiloxanos , Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Desenho de Equipamento , Grafite , Microfluídica/economia
2.
Blood Cells Mol Dis ; 67: 104-113, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28844459

RESUMO

Sickle cell disease (SCD) is a common and life threatening inherited blood disorder, affecting over 300,000 newborns per year. Over 75% of SCD births occur in sub-Saharan Africa, where the lack of timely and accurate diagnosis results in premature death within the first few years of life for a majority of affected infants. Current methods to diagnosis SCD require expensive laboratory equipment and reagents, and adequately trained laboratory personnel. In addition, test results are often delayed due to transport and batching of samples in a central laboratory. Financial and technical limitations often preclude any form of SCD laboratory testing at the local level in regions where SCD is most prevalent. There has been a recent surge of interest in addressing the global burden of SCD, including improving and optimizing diagnostic capacities. Largely stimulated by a funding opportunity from the NIH, several point-of-care diagnostics have been developed for SCD with a focus on developing devices that are inexpensive, simple, and practical in limited resource settings. In this manuscript, we review the global burden of SCA, including the rationale for the development of POC assays, and carefully review the POC devices currently in development.


Assuntos
Anemia Falciforme/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Anemia Falciforme/sangue , Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Desenho de Equipamento , Saúde Global , Humanos , Imunoensaio/economia , Imunoensaio/instrumentação , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito/economia , Smartphone/economia , Smartphone/instrumentação
3.
ACS Nano ; 11(7): 6641-6651, 2017 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-28671449

RESUMO

Exosomes found in the circulation are a primary source of important cancer-related RNA and protein biomarkers that are expected to lead to early detection, liquid biopsy, and point-of-care diagnostic applications. Unfortunately, due to their small size (50-150 nm) and low density, exosomes are extremely difficult to isolate from plasma. Current isolation methods are time-consuming multistep procedures that are unlikely to translate into diagnostic applications. To address this issue, we demonstrate the ability of an alternating current electrokinetic (ACE) microarray chip device to rapidly isolate and recover glioblastoma exosomes from undiluted human plasma samples. The ACE device requires a small plasma sample (30-50 µL) and is able to concentrate the exosomes into high-field regions around the ACE microelectrodes within 15 min. A simple buffer wash removes bulk plasma materials, leaving the exosomes concentrated on the microelectrodes. The entire isolation process and on-chip fluorescence analysis is completed in less than 30 min which enables subsequent on-chip immunofluorescence detection of exosomal proteins, and provides viable mRNA for RT-PCR analysis. These results demonstrate the ability of the ACE device to streamline the process for isolation and recovery of exosomes, significantly reducing the number of processing steps and time required.


Assuntos
Eletroforese em Microchip/instrumentação , Exossomos/patologia , Análise em Microsséries/instrumentação , Neoplasias/diagnóstico , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/isolamento & purificação , Linhagem Celular , Eletroforese em Microchip/economia , Desenho de Equipamento , Exossomos/química , Glioblastoma/sangue , Glioblastoma/diagnóstico , Glioblastoma/patologia , Humanos , Análise em Microsséries/economia , Microeletrodos , Neoplasias/sangue , Neoplasias/patologia , Proteínas/análise , RNA/análise , Fatores de Tempo
4.
Electrophoresis ; 38(2): 250-257, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27377397

RESUMO

This study describes a simple, rapid, and cost-effective fabrication of PDMS electrophoresis microchips using poly(vinyl acetate) (PVAc) emulsion as photoresist master. High-relief microfluidic structures were defined on poly(vinyl acetate) previously deposited on printed circuit boards surfaces without cleanroom facilities and sophisticated instrumentation. After a UV exposure, channels with heights ranging from 30 to 140 µm were obtained by controlling the emulsion mass deposited on the master surface. The developing stage was performed using water rather than the organic solvents that are applied for conventional masks. The surface morphology was characterized by optical imaging, profilometry, and SEM. Based on the achieved results, the proposed method offers suitable reproducibility for the prototyping of electrophoresis microchips in PDMS. The feasibility of the resulting PDMS electrophoresis chips was successfully demonstrated with the separation of major inorganic cations within 100 s using a contactless conductivity detection system. The separation efficiencies ranged from ca. 67 900 to 125 600 plates/m. Due to the satisfactory performance and simplified instrumentation, we believe this fabrication protocol presents potential to be implemented in any chemical, biochemical, or biological laboratory.


Assuntos
Dimetilpolisiloxanos/química , Eletroforese em Microchip/instrumentação , Desenho de Equipamento/métodos , Nylons/química , Polivinil/química , Condutividade Elétrica
5.
Artigo em Inglês | MEDLINE | ID: mdl-27322633

RESUMO

An insertion (I)/deletion (D) polymorphism in angiotensin-converting enzyme (ACE) has been associated with susceptibility to various diseases in numerous studies. Traditionally, slab gel electrophoresis (SGE) after polymerase chain reaction (PCR) has been used to genotype this ACE I/D polymorphism. In this study, single- and multi-channel microchip electrophoresis (ME) methods based on variable programmed electric field strength (PEFS) (i.e., low constant, high constant, (+)/(-) staircase, and random electric field strengths) were developed for fast high-throughput screening of this specific polymorphism. The optimum PEFS conditions were set as 470V/cm for 0-9s, 129V/cm for 9-13s, 470V/cm for 13-13.9s, 294V/cm for 13.9-16s, and 470V/cm for 16-20s for single-channel ME, and 615V/cm for 0-22.5s, 231V/cm for 22.5-28.5s, and 615V/cm for 28.5-40s for multi-channel ME, respectively. In the multi-channel PEFS-ME, target ACE I/D polymorphism DNA fragments (D=190bp and I=490bp) were identified within 25s without loss of resolving power, which was ∼300 times faster than conventional SGE. In addition, PCR products of the ACE gene from human blood samples were detected after only 10 cycles by multi-channel PEFS-ME, but not by SGE. This parallel detection multichannel-based PEFS-ME method offers a powerful tool for fast high-throughput ACE I/D polymorphism screening with high sensitivity.


Assuntos
Eletroforese em Microchip/métodos , Peptidil Dipeptidase A/genética , Polimorfismo Genético , Sequência de Bases , Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Desenho de Equipamento , Ensaios de Triagem em Larga Escala/economia , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Mutação INDEL , Mutagênese Insercional , Deleção de Sequência
6.
Lab Chip ; 15(24): 4563-70, 2015 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-26496877

RESUMO

Heterogeneous immunoassays usually require long incubation times to promote specific target binding and several wash steps to eliminate non-specific binding. Hence, signal saturation is rarely achieved at detection limit levels of analyte, leading to significant errors in analyte quantification due to extreme sensitivity of the signals to incubation time and methodology. The poor binding kinetics of immunoassays at detection limit levels can be alleviated through creating an enriched analyte plug in the vicinity of immobilized capture probes to enable signal saturation at higher levels and at earlier times, due to higher analyte association and its faster replenishment at the binding surface. Herein, we achieve this by coupling frequency-selective dielectrophoretic molecular dam enrichment of the target biomarker in physiological media to capture probes immobilized on graphene-modified surfaces in a nanoslit to enable ultrafast immunoassays with near-instantaneous (<2 minutes) signal saturation at dilute biomarker levels (picomolar) within ultra-low sample volumes (picoliters). This methodology is applied to the detection of Prostate Specific Antigen (PSA) diluted in serum samples, followed by validation against a standard two-step immunoassay using three de-identified patient samples. Based on the ability of dielectrophoretic molecular dam analyte enrichment methods to enable the detection of PSA at 1-5 pg mL(-1) levels within a minute, and the relative insensitivity of the signals to incubation time after the first two minutes, we envision its application for improving the sensitivity of immunoassays and their accuracy at detection limit levels.


Assuntos
Técnicas Eletroquímicas/instrumentação , Grafite/química , Imunoensaio/instrumentação , Nanoestruturas/química , Antígeno Prostático Específico/sangue , Anticorpos Imobilizados/química , Técnicas Eletroquímicas/economia , Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Desenho de Equipamento , Feminino , Humanos , Imunoensaio/economia , Limite de Detecção
7.
Biomed Microdevices ; 17(1): 4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25653061

RESUMO

This work presents a fast, simple, and cost-effective technique for fabricating and integrating highly conductive 3D microelectrodes into microfluidic devices. The 3D electrodes are made of low cost, commercially available conductive adhesive and carbon powder. The device can be fabricated by a single-step soft lithography and controllable injections of a conductive composite into microchannels. Functioning of the microfluidic device with 3D electrodes was demonstrated through DEP particle switching as an example for a wide range of microfluidic applications.


Assuntos
Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Eletrodos
8.
Electrophoresis ; 35(11): 1728-34, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25025095

RESUMO

To determine the adulteration of soybean proteins in dairy product, a microchip-CE device was developed to isolate selected fraction of soybean and milk proteins in pI range from 5.5 ∼ 7.0 by 1D IEF, followed by ITP/CZE in the embedded capillary for preconcentration, separation and UV detection at 280 nm. Compared to IEF-CZE without ITP preconcentration, the enhancement factor (EF) in detection of soybean proteins was 20 times. Adulteration of 0.1% soybean protein in total dairy proteins can be detected in less than 10 min.


Assuntos
Laticínios/análise , Eletroforese em Microchip/instrumentação , Análise de Alimentos/instrumentação , Qualidade dos Alimentos , Proteínas do Leite/análise , Proteínas de Soja/análise , Desenho de Equipamento , Proteínas do Leite/isolamento & purificação , Proteínas de Soja/isolamento & purificação
9.
Electrophoresis ; 34(20-21): 2980-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23925858

RESUMO

A simple method for producing PMMA electrophoresis microchips with in-plane electrodes for capacitively coupled contactless conductivity detection is presented. One PMMA plate (channel plate) is embossed with the microfluidic and electrode channels and lamination bonded to a blank PMMA cover plate of equal dimensions. To incorporate the electrodes, the bonded chip is heated to 80 °C, above the melting point of the alloy (≈ 70 °C) and below the glass transition temperature of the PMMA (≈ 105 °C), and the molten alloy drawn into the electrode channels with a syringe before being allowed to cool and harden. A 0.5 mm diameter stainless steel pin is then inserted into the alloy filled reservoirs of the electrode channels to provide external connection to the capacitively coupled contactless conductivity detection detector electronics. This advance provides for a quick and simple manufacturing process and negates the need for integrating electrodes using costly and time-consuming thin film deposition methods. No additional detector cell mounting structures were required and connection to the external signal processing electronics was achieved by simply slipping commercially available shielded adaptors over the pins. With a non-optimised electrode arrangement consisting of a 1 mm detector gap and 100 µm insulating distance, rapid separations of ammonium, sodium and lithium (<22 s) yielded LODs of approximately 1.5-3.5 ppm.


Assuntos
Ligas/química , Eletroforese em Microchip/instrumentação , Polimetil Metacrilato/química , Compostos de Amônio/isolamento & purificação , Condutividade Elétrica , Eletrodos , Eletroforese em Microchip/economia , Desenho de Equipamento , Limite de Detecção , Lítio/isolamento & purificação , Sódio/isolamento & purificação
10.
J Chromatogr A ; 1304: 251-6, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-23870545

RESUMO

Here we report on a simple method to fabricate microfluidic chip incorporating multi-channel systems packed by conventional chromatographic particles without the use of frits. The retaining effectivities of different bottlenecks created in the channels were studied. For the parallel multi-channel chromatographic separations several channel patterns were designed. The obtained multipackings were applied for parallel separations of dyes. The implementation of several chromatographic separation units in microscopic size makes possible faster and high throughput separations.


Assuntos
Eletroforese em Microchip/instrumentação , Corantes/isolamento & purificação , Dimetilpolisiloxanos/química , Eletroforese em Microchip/economia , Desenho de Equipamento , Microtecnologia , Fatores de Tempo
11.
J Chromatogr A ; 1304: 220-6, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-23870546

RESUMO

To improve resolution of important minor proteins and eliminate time-consuming precipitation of major protein with associated analyte co-precipitation risk, a multi-dimension strategy is adopted in the 2D microchip-CE device to isolate major proteins on-chip, enrich minor proteins in capillary before their separation in CE for UV quantitation. A standard fluorescent protein mixture containing FITC-BSA, myoglobin and cytochrome as specific pI markers has prepared to demonstrate capability of the device to fractionate minor proteins by IEF. The results using a standard protein mixture with profile resembling infant milk formula show a complete isolation of high abundance proteins by a 2-min 1D IEF run. The subsequent t-ITP/CZE run by on-chip high voltage switching delivers a high stacking ratio, realizing 60 folds enrichment of isolated protein fractions. All five important functional proteins (LF, IgG, α-LA, ß-LgA and ß-LgB) known to fortify infant milk formula are isolated and determined using two consecutive t-ITP-CZE runs within a 18-min total assay time, a significant saving compared to several hours conventional pretreatment. For a 100g infant milk formula sample, working ranges of 20-8000mg, repeatability 3.8-5.3% and detection limits 2.3-10mg have been achieved to meet government regulations. Method reliability is established by 100% recoveries and agreeable results within expected ranges and labeled values. The capability of the device for field operation, rapid assay with quick results, label-free universal detection, simple operation by aqueous dissolution before injection, and the demanding matching in 2D separation based on isolated fractions at specified pI ranges, closely matched migration time and baseline-resolved peak shape makes the device a general tool to detect unknown proteins and determine known minor proteins in protein-rich samples with interfering constituents.


Assuntos
Eletroforese em Microchip/instrumentação , Fórmulas Infantis/química , Proteínas do Leite/isolamento & purificação , Eletroforese em Microchip/economia , Desenho de Equipamento , Fluoresceína-5-Isotiocianato/análogos & derivados , Fluoresceína-5-Isotiocianato/isolamento & purificação , Humanos , Lactente , Focalização Isoelétrica/instrumentação , Limite de Detecção , Reprodutibilidade dos Testes , Soroalbumina Bovina/isolamento & purificação
12.
Electrophoresis ; 34(11): 1539-47, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23529977

RESUMO

In this paper, a rapid thermal cycling procedure is combined with a direct amplification from a paper punch, permitting a high-speed amplification of a 7-locus multiplex that requires no extraction step. When coupled with a short 1.8 cm microfluidic electrophoresis system, the entire procedure from paper punch to genotype can be completed in under 25 min. The paper describes selection and optimization of enzyme, direct amplification conditions, the reproducibility of the procedure, and concordance with standard forensic genotyping methods. The procedure utilizes a small high-speed thermal cycler and microfluidic device along with a small laptop and is highly portable. Overall, this technique should provide a useful and reliable procedure for rapid determination of identity of individuals retained at checkpoints as well as a quick method for preliminary identification of individuals at remote locations following mass disasters.


Assuntos
DNA/análise , Eletroforese em Microchip/instrumentação , Técnicas de Genotipagem/instrumentação , Reação em Cadeia da Polimerase/instrumentação , DNA/genética , Eletroforese em Microchip/economia , Técnicas de Genotipagem/economia , Humanos , Reação em Cadeia da Polimerase/economia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
13.
Anal Chem ; 84(20): 8830-6, 2012 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-22978243

RESUMO

We report the fabrication of two different cell patterns based on negative dielectrophoresis (n-DEP) and apply it to simple and rapid distinction of cells with specific surface antigens from a cell population. The DEP device for cell manipulation comprised a microfluidic channel with an upper indium tin oxide (ITO) electrode and a lower ITO-interdigitated band array (ITO-IDA) electrode modified with an antibody. Cells immediately accumulated on the surface in the gap area between both bands of the ITO-IDA electrode by n-DEP upon AC voltage between the upper ITO and both lower bands. Switching of the applied band electrode voltage resulted in the removal of accumulated cells to form another pattern because of the formation of a different electric field pattern in the device. Modifying the ITO-IDA surface with the antibody inhibited the removal of the cells with a specific surface antigen for irreversible capture by immunoreactions during the first accumulation. In this study, we targeted the CD33 surface antigen expressed on human promyelocytic leukemia cells (HL-60). The time required for the assay was substantially short: 60 s for forcing and 60 s for separating the unbound cells. Furthermore, the present method does not require pretreatment such as target labeling or washing of unbound cells. Moreover, the use of the swing technique considerably improved cell binding to the antibody-modified surface for cells with a specific surface antigen. The distinct integration of cells with n-DEP in the high conductivity medium provided higher cell binding efficiency compared to that obtained in our previous study (Hatanaka, H.; Yasukawa, T.; Mizutani, F. Anal. Chem., 2011, 83, 7207-7212) without loss of rapidity and simplicity.


Assuntos
Eletroforese em Microchip/instrumentação , Lectina 3 Semelhante a Ig de Ligação ao Ácido Siálico/análise , Anticorpos Imobilizados/imunologia , Anticorpos Monoclonais/imunologia , Técnicas Biossensoriais/economia , Técnicas Biossensoriais/instrumentação , Eletrodos , Eletroforese em Microchip/economia , Desenho de Equipamento , Células HL-60 , Humanos , Lectina 3 Semelhante a Ig de Ligação ao Ácido Siálico/imunologia , Fatores de Tempo , Compostos de Estanho/química
14.
Anal Bioanal Chem ; 401(8): 2465-71, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21912834

RESUMO

Free-flow electrophoresis techniques have been applied for separations in various areas of chemistry and biochemistry. Here we focus on the generation of a free-flow electrophoresis chip and direct monitoring of the separation of different molecules in the separation bed of the miniaturized chip. We demonstrate a fast and efficient way to generate a low-cost micro-free-flow electrophoresis (µFFE) chip with a filling capacity of 9.5 µL based on a multi-lamination technique. Separating webs realized by two transfer-adhesive tapes avoid the problem of gas bubbles entering the separation area. The chip is characterized by isoelectric focusing markers (IEF markers). The functionality of the chip is demonstrated by free-flow isoelectric focusing (FFIEF) of the proteins BSA (bovine serum albumin) and avidin and a single-stranded DNA (ssDNA) fragment in the pH range 3 to 10. The separation voltage ranges between 167 V cm(-1) and 422 V cm(-1), depending on the application.


Assuntos
Avidina/isolamento & purificação , DNA de Cadeia Simples/isolamento & purificação , Eletroforese em Microchip/instrumentação , Focalização Isoelétrica/instrumentação , Soroalbumina Bovina/isolamento & purificação , Animais , Bovinos , Eletroforese em Microchip/economia , Desenho de Equipamento , Focalização Isoelétrica/economia , Fatores de Tempo
15.
Artigo em Inglês | MEDLINE | ID: mdl-22256292

RESUMO

The versatility of a simple method for producing microfluidic devices with embedded electrodes is demonstrated through the fabrication and operation of two dielectrophoretic devices; one employing interdigitated electrode structures on glass and the other employing contactless electrode reservoirs. Device manufacture is based on the precipitation of silver and subsequent photolithography of thin film resists conducted outside of a cleanroom environment. In current experiments, minimum channel widths of 50 microns and electrode widths of 25 microns are achieved when the distance between features is 40 microns or greater. These results illustrate this technique's potential to produce microfluidic devices with embedded electrodes for lab on chip applications while significantly reducing fabrication expense.


Assuntos
Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Dimetilpolisiloxanos/química , Fontes de Energia Elétrica , Eletrodos , Raios Ultravioleta
16.
Electrophoresis ; 31(15): 2526-33, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665913

RESUMO

In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-microm thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47,000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.


Assuntos
Eletroforese em Microchip/instrumentação , Vidro , Microtecnologia/métodos , Dimetilpolisiloxanos/química , Eletroforese em Microchip/economia , Desenho de Equipamento , Vidro/química , Fatores de Tempo
17.
Electrophoresis ; 31(15): 2548-57, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665915

RESUMO

An approach to performing in-line extraction employing functionalized magnetic particles for CE and microchip electrophoresis is presented. Silica-coated iron oxide particles were synthesized and used as the solid support. The particles were functionalized with octadecylsilane and used as reverse-phase sorbents for in-line SPE followed by electrophoresis. Magnets were used to locally immobilize these sorbents inside the capillary or microchip. Extraction, elution, and detection of the analytes were performed sequentially without interruption or need for sample handling. Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic sorbents. CE was able to extract and separate mixture of parabens within 10 min. In-line extraction was also carried out on a disposable PMMA microfluidic device with LIF detection. Electrophoretic separation of fluorescent dyes, Rhodamine 110 and SulfoRhodamine B, was completed in under a minute. The results demonstrated the feasibility of performing the in-line extraction/separation technique in a microchip platform enabling rapid analysis, low sorbent consumption, and increased analyte recovery (relative to the capillary format).


Assuntos
Eletroforese Capilar/métodos , Eletroforese em Microchip/métodos , Compostos Férricos/química , Magnetismo , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Eletroforese Capilar/economia , Eletroforese Capilar/instrumentação , Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Desenho de Equipamento , Corantes Fluorescentes/isolamento & purificação , Parabenos/isolamento & purificação , Silanos/química , Extração em Fase Sólida/economia , Fatores de Tempo
18.
Electrophoresis ; 31(15): 2584-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665917

RESUMO

By applying integrated-waveguide laser excitation to an optofluidic chip, fluorescently labeled DNA molecules of 12 or 17 different sizes are separated by CE with high operating speed and low sample consumption of approximately 600 pL. When detecting the fluorescence signals of migrating DNA molecules with a PMT, the LOD is as low as 2.1 pM. In the diagnostically relevant size range (approximately 150-1000 base-pairs) the molecules are separated with reproducibly high sizing accuracy (> 99%) and the plug broadening follows Poissonian statistics. Variation of the power dependence of migration time on base-pair size--probably with temperature and condition of the sieving gel matrix--indicates that the capillary migration cannot be described by a simple physical law. Integrated-waveguide excitation of a 12-microm narrow microfluidic segment provides a spatio-temporal resolution that would, in principle, allow for a 20-fold better accuracy than the currently supported by state-of-the-art electrophoretic separation in microchips, thereby demonstrating the potential of this integrated optical approach to fulfill the resolution demands of future electrophoretic microchips.


Assuntos
DNA/isolamento & purificação , Eletroforese em Microchip/instrumentação , Pareamento de Bases , Eletroforese Capilar/economia , Eletroforese Capilar/instrumentação , Eletroforese em Microchip/economia , Desenho de Equipamento , Corantes Fluorescentes , Sensibilidade e Especificidade
19.
Electrophoresis ; 31(15): 2602-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20665918

RESUMO

Haloacetic acids (HAAs) were determined by a fast and simple analysis method based on microchip electrophoresis and capacitively coupled contactless conductivity detection (C(4)D). Two chlorinated acetic acids, dichloroacetic acid (DCAA) and TCA were detected in swimming pool water. Different BGEs were tested, and sodium carbonate was selected as BGE for the separation and detection in the reported experiments. Additionally, pH values and concentrations of carbonate buffer were optimized. The response times for the two analytes were less than 3 min; the lowest detected concentrations for TCA and DCAA after extraction and cleanup were 38 and 62 microg/L and the RSDs for the migration times were 1.9 and 2.2%. TCA and DCAA were identified swimming pool water samples at concentrations ranging from 391 to 1058 microg/L. In combination with a SPE-based concentration and cleanup procedure, this miniaturized system shows the potential for development as an on-site monitoring method for chlorinated acetic acids found in swimming pool water or other suspected water systems.


Assuntos
Acetatos/isolamento & purificação , Eletroforese em Microchip/métodos , Halogenação , Extração em Fase Sólida/métodos , Água/análise , Acetatos/química , Carbonatos/química , Desinfecção , Eletroforese em Microchip/economia , Eletroforese em Microchip/instrumentação , Desenho de Equipamento , Sensibilidade e Especificidade , Extração em Fase Sólida/economia , Extração em Fase Sólida/instrumentação , Piscinas
20.
Electrophoresis ; 31(15): 2541-7, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20603828

RESUMO

A simple hydrodynamic injection method is proposed here for microchip CE coupled to electrochemical detection. It is based on the use of a precise syringe pump to push the sample into the microfluidic circuit, accompanied by the application of a secondary electric field to the injection channel, soon after the end of the injection step. In such a way, any counter pressure effect taking place when the sample plug enters the micrometric channel is prevented. Suitable optimization of this secondary electric field enables pushing of sample excess to be avoided and a narrow sample plug during the separation step to be maintained. Best conditions for hydrodynamic injection were achieved injecting catechol as model analyte by pressure with a syringe pump set at a flow rate of 8 microL/min for 6 s and applying to the injection channel a secondary high voltage of 700 V soon after the injection was completed. The reliability of this injection procedure has been proved by comparing electropherograms found for samples containing either catechol alone or catechol and dopamine together with those recorded under the same conditions by electrokinetic injection. Repeatability, expressed as RSD and estimated for seven replicate injections, turned out to be 2.1% for peak height of catechol used as single analyte and 0.9 and 1.1% for catechol and dopamine respectively, simultaneously injected.


Assuntos
Eletroforese em Microchip/instrumentação , Catecóis/isolamento & purificação , Dopamina/isolamento & purificação , Eletroquímica , Eletroforese em Microchip/economia , Eletroforese em Microchip/métodos , Desenho de Equipamento , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA