Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 58(3): 354-359, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33998101

RESUMO

OBJECTIVE: To examine the impact of first-trimester crown-rump length (CRL) measurement error on the interpretation of estimated fetal weight (EFW) and classification of fetuses as small-, large- or appropriate-for-gestational age on subsequent growth scans. METHODS: We examined the effects of errors of ± 2, ± 3 and ± 4 mm in the measurement of fetal CRL on percentiles of EFW at 20, 32 and 36 weeks' gestation and classification as small-, large- or appropriate-for-gestational age. Published data on CRL measurement error were used to determine variation present in practice. RESULTS: A measurement error of -2 mm in first-trimester CRL shifts an EFW on the 10th percentile at the 20-week scan to around the 20th percentile, and the effect of a CRL measurement error of + 2 mm would shift an EFW on the 10th percentile to around the 5th percentile. At 32 weeks, a first-trimester CRL measurement error would shift an EFW on the 10th percentile to the 7th (+ 2 mm) or 14th (-2 mm) percentile; at 36 weeks, the EFW would shift from the 10th percentile to the 8th (+ 2 mm) or 12th (-2 mm) percentile. Published data suggest that measurement errors of 2 mm or more are common in practice. CONCLUSION: Because of the widespread and potentially severe consequences of CRL measurement errors as small as 2 mm on clinical assessment, patient management and research results, there is a need to increase awareness of the impact of CRL measurement error and to reduce measurement error variation through standardization and quality control. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Estatura Cabeça-Cóccix , Erros de Diagnóstico/efeitos adversos , Retardo do Crescimento Fetal/diagnóstico , Feto/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Feminino , Desenvolvimento Fetal , Peso Fetal , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Trimestres da Gravidez , Valores de Referência
2.
J Obstet Gynaecol Can ; 41(10): 1497-1507, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31548039

RESUMO

OBJECTIVE: To assist clinicians in assigning gestational age based on ultrasound biometry. OUTCOMES: To determine whether ultrasound dating provides more accurate gestational age assessment than menstrual dating with or without the use of ultrasound. To provide maternity health care providers and researchers with evidence-based guidelines for the assignment of gestational age. To determine which ultrasound biometric parameters are superior when gestational age is uncertain. To determine whether ultrasound gestational age assessment is cost effective. EVIDENCE: Published literature was retrieved through searches of PubMed or MEDLINE and The Cochrane Library in 2013 using appropriate controlled vocabulary and key words (gestational age, ultrasound biometry, ultrasound dating). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies written in English. There were no date restrictions. Searches were updated on a regular basis and incorporated in the guideline to July 31, 2013. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. VALUES: The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). BENEFITS, HARMS, AND COSTS: Accurate assignment of gestational age may reduce post-dates labour induction and may improve obstetric care through allowing the optimal timing of necessary interventions and the avoidance of unnecessary ones. More accurate dating allows for optimal performance of prenatal screening tests for aneuploidy. A national algorithm for the assignment of gestational age may reduce practice variations across Canada for clinicians and researchers. Potential harms include the possible reassignment of dates when significant fetal pathology (such as fetal growth restriction or macrosomia) result in a discrepancy between ultrasound biometric and clinical gestational age. Such reassignment may lead to the omission of appropriate-or the performance of inappropriate-fetal interventions. SUMMARY STATEMENTS: RECOMMENDATIONS.


Assuntos
Estatura Cabeça-Cóccix , Idade Gestacional , Ultrassonografia Pré-Natal , Abdome/diagnóstico por imagem , Biometria , Feminino , Fêmur/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Segundo Trimestre da Gravidez
3.
Ultrasound Obstet Gynecol ; 53(6): 715-723, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31169958

RESUMO

INTRODUCTION These Guidelines aim to describe appropriate assessment of fetal biometry and diagnosis of fetal growth disorders. These disorders consist mainly of fetal growth restriction (FGR), also referred to as intrauterine growth restriction (IUGR) and often associated with small­for­gestational age (SGA), and large­for­gestational age (LGA), which may lead to fetal macrosomia; both have been associated with a variety of adverse maternal and perinatal outcomes. Screening for, and adequate management of, fetal growth abnormalities are essential components of antenatal care, and fetal ultrasound plays a key role in assessment of these conditions. The fetal biometric parameters measured most commonly are biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur diaphysis length (FL). These biometric measurements can be used to estimate fetal weight (EFW) using various different formulae1. It is important to differentiate between the concept of fetal size at a given timepoint and fetal growth, the latter being a dynamic process, the assessment of which requires at least two ultrasound scans separated in time. Maternal history and symptoms, amniotic fluid assessment and Doppler velocimetry can provide additional information that may be used to identify fetuses at risk of adverse pregnancy outcome. Accurate estimation of gestational age is a prerequisite for determining whether fetal size is appropriate­for­gestational age (AGA). Except for pregnancies arising from assisted reproductive technology, the date of conception cannot be determined precisely. Clinically, most pregnancies are dated by the last menstrual period, though this may sometimes be uncertain or unreliable. Therefore, dating pregnancies by early ultrasound examination at 8­14 weeks, based on measurement of the fetal crown­rump length (CRL), appears to be the most reliable method to establish gestational age. Once the CRL exceeds 84 mm, HC should be used for pregnancy dating2­4. HC, with or without FL, can be used for estimation of gestational age from the mid­trimester if a first­trimester scan is not available and the menstrual history is unreliable. When the expected delivery date has been established by an accurate early scan, subsequent scans should not be used to recalculate the gestational age1. Serial scans can be used to determine if interval growth has been normal. In these Guidelines, we assume that the gestational age is known and has been determined as described above, the pregnancy is singleton and the fetal anatomy is normal. Details of the grades of recommendation used in these Guidelines are given in Appendix 1. Reporting of levels of evidence is not applicable to these Guidelines.


Pautas de ISUOG para la práctica: evaluación ecográfica de la biometría y el crecimiento fetal INTRODUCCIÓN: El objetivo de estas Pautas es describir la evaluación adecuada de la biometría fetal y el diagnóstico de los trastornos del crecimiento fetal. Estos trastornos consisten principalmente en la restricción del crecimiento fetal (RCF), también conocida como restricción del crecimiento intrauterino (RCIU), que a menudo está asociada con un tamaño pequeño para la edad gestacional (PEG) o grande para la edad gestacional (GEG), que pueden dar lugar a la macrosomía fetal; ambos se han asociado con una variedad de resultados maternos y perinatales adversos. La detección y el tratamiento adecuado de las anomalías del crecimiento fetal son componentes esenciales de la atención prenatal, y la ecografía fetal desempeña un papel fundamental en la evaluación de estas afecciones. Los parámetros biométricos fetales medidos con mayor frecuencia son (todas las siglas procedentes del inglés) el diámetro biparietal (BPD), el perímetro cefálico (HC), el perímetro abdominal (AC) y la longitud de la diáfisis del fémur (FL). Estas mediciones biométricas se pueden utilizar para estimar el peso del feto (PEF) mediante fórmulas diferentes1 . Es importante diferenciar entre el concepto de tamaño fetal en un momento dado y el crecimiento fetal en sí, siendo este último un proceso dinámico cuya evaluación requiere al menos dos ecografías separadas en el tiempo. La historia y los síntomas de la madre, la evaluación del líquido amniótico y la velocimetría Doppler pueden proporcionar información adicional que se puede utilizar para identificar los fetos bajo riesgo de resultados adversos del embarazo. La estimación precisa de la edad gestacional es un prerrequisito para determinar si el tamaño del feto es apropiado para la edad gestacional (AEG). Excepto en el caso de los embarazos procedentes de tecnologías de reproducción asistida, la fecha de concepción no se puede determinar con precisión. Clínicamente, la fecha de la mayoría de los embarazos se establece en función del último período menstrual, aunque a veces esto puede ser incierto o poco fiable. Por lo tanto, el fechado de los embarazos mediante ecografía temprana a las 8-14 semanas, mediante la medición de la longitud céfalo-caudal (LCC) fetal, parece ser el método más fiable para establecer la edad gestacional. Una vez que la LCC excede los 84 mm, se debe usar el HC2-4 para establecer la fecha del embarazo. El HC, con o sin FL, se puede utilizar para estimar la edad gestacional a partir de la mitad del primer trimestre si no se dispone de una ecografía del primer trimestre y el historial menstrual no es fiable. Cuando se ha establecido la fecha prevista del parto mediante una exploración temprana precisa, no se deben utilizar exploraciones posteriores para recalcular la edad gestacional1 . Las exploraciones en serie se pueden utilizar para determinar si el intervalo del crecimiento ha sido normal. En estas Pautas se asume que la edad gestacional es conocida y ha sido determinada según lo anterior, que el embarazo es de feto único y que la anatomía fetal es normal. En el Apéndice 1 se detallan los grados de recomendación utilizados en estas Pautas. El informe sobre los niveles de evidencia no es aplicable a estas Pautas.


Assuntos
Guias de Prática Clínica como Assunto , Ultrassonografia Pré-Natal/normas , Biometria , Estatura Cabeça-Cóccix , Feminino , Retardo do Crescimento Fetal/diagnóstico , Humanos , Obstetrícia , Gravidez , Sociedades Médicas
4.
Eur J Obstet Gynecol Reprod Biol ; 234: 75-78, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30660942

RESUMO

OBJECTIVE: The aim of this work was to assess the cost-effectiveness of the fetal fibronectin (fFN) test at 48 h after admission for threatened preterm delivery to promote early discharge. STUDY DESIGN: Before-and-after study to calculate the incremental cost-effectiveness ratio (ICER). Patients were enrolled 48 h after admission in a tertiary care centre for threatened preterm delivery between 24+0 and 34+6 weeks. fFN testing was performed. During the first period, physician was blinded to fFN test and discharge occurred after apparent reduced symptomatology at physician's discretion. During the second period, fFN test was revealed to physician and discharge was immediately proposed to negative test patients. The costs considered in this analysis were the direct medical costs from the hospital perspective: costs of hospitalisation, treatment, and imaging procedures. The efficacy criterion selected was the number of deliveries at 7 and at 14 days after admission for threatened preterm delivery. RESULTS: The study included 178 pregnant patient, 99 during the first period (July 2008-October 2009) and 79 during the second (March 2010-February 2012). The lengths of hospital stays were shorter during the second period, with more than 50% of women discharged home between 48 and 72 h (p < 0.0001) resulting in a cost-saving of 76 051 euros. The number of deliveries at 7 and at 14 days was similar between the two periods. CONCLUSION: The fFN test at 48 h after admission supported early discharge and was safe and cost-effective.


Assuntos
Fibronectinas/sangue , Valor Preditivo dos Testes , Nascimento Prematuro/diagnóstico , Adulto , Medida do Comprimento Cervical , Análise Custo-Benefício , Estatura Cabeça-Cóccix , Feminino , Idade Gestacional , Humanos , Tempo de Internação/economia , Alta do Paciente/economia , Gravidez , Nascimento Prematuro/economia , Nascimento Prematuro/epidemiologia , Adulto Jovem
5.
PLoS One ; 13(11): e0207682, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30452469

RESUMO

Although transport and slaughter of cattle during the last 10% of the gestation period is prohibited in the European Union, such cattle are sometimes sent for slaughter. The late term pregnancy is usually not recognized by the authorities until the uterus is inspected after slaughter and a near term fetus is observed. Accurate post mortem determination of age of bovine fetuses is therefore of major importance as evidence for the subsequent prosecution of the owner. Fetometric measurements such as crown-rump length (CRL) have been used, but these existing estimators have often been established based on insufficiently described study populations or phenotypes that may have changed in the past decades. Morphological characteristics are also used, but few data are available on the correlation between fetal age and the development of these characteristics. The objectives of this study were to investigate the correlation between fetal age and morphological features of bovine Holstein fetuses and to evaluate the use of these features alone and in combination with fetometric measurements to predict fetal age. We collected fetuses from 274 pregnant Holstein cows with recorded insemination dates slaughtered at a Danish abattoir. Gender, teeth development, occurrence of pigmentation, coat, tactile hair and other morphological features were recorded along with CRL, head width, head length and body weight (BW). The gestational length was calculated based on recorded insemination and slaughter dates, and coefficients of variation (R2) were determined for all recorded variables. Notably, the highest R2 was recorded for head length (0.985) followed by CRL (0.979) and head width (0.974). The categorical (morphological) variables were less informative. When used in multivariable models, they did offer statistically significance, but for practical purposes, limited additional information. A multivariable model including the fetometric variables head length and width in combination with CRL resulted in R2 = 0.99 with predictions that were roughly within +/- 11-12 days in 95% of cases. We conclude that the model based on the fetometric variables only provided the most precise predictions, while combination with morphological features such as eruption of teeth, pigmentation and coat mostly increased the width of the prediction intervals.


Assuntos
Pesos e Medidas Corporais/veterinária , Bovinos/embriologia , Idade Gestacional , Animais , Autopsia , Tamanho Corporal , Estatura Cabeça-Cóccix , Feminino , Masculino , Gravidez , Fatores Sexuais
6.
Gynecol Obstet Fertil Senol ; 46(2): 86-92, 2018 Feb.
Artigo em Francês | MEDLINE | ID: mdl-29352716

RESUMO

OBJECTIVE: Ultrasound examination plays a central role in case of suspected non-viable pregnancy. A wrong diagnosis might have major consequence in terms of inadequate care, especially in cases of false positive non-viable pregnancy diagnosis. Ultrasound criterions are today well defined. Our objective was to evaluate the feasibility and reproducibility of a novel image-quoting method of first-trimester non-viable pregnancy. METHODS: Thirty images of non-viable pregnancy were twice evaluated with blinded proofreading. Two quotations were evaluated: the first for the images of gestational sacs without embryo (gestational sac score), the second for the images with embryo (embryo score). RESULTS: The ICC (interclass correlation coefficient) was>0.75 for inter- and intra-observer reproducibility both for the quotations of the gestational sac and for the embryo with a low variability. Reproducibility of quoting crown rump length measurements <5mm was low at first proofreading but after adjustment of the quoting modalities, ICC was also>0.75. CONCLUSION: The inter- and intra-observer reproducibility of our quoting methods is high with a low variability. They might be a useful tool in current practice in the future.


Assuntos
Aborto Espontâneo/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Aborto Espontâneo/terapia , Estatura Cabeça-Cóccix , Erros de Diagnóstico , Feminino , Idade Gestacional , Saco Gestacional/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes
7.
Ultrasound Obstet Gynecol ; 51(4): 437-444, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28925570

RESUMO

OBJECTIVE: This was a randomized controlled trial to compare risk assessment by first-trimester combined screening (FTCS) with an approach that combines a detailed ultrasound examination at 11-13 weeks' gestation and cell-free DNA (cfDNA) analysis. METHODS: Pregnant women with a normal first-trimester ultrasound examination at 11-13 weeks' gestation (fetal nuchal translucency (NT) ≤ 3.5 mm and no fetal defects) were randomized into one of two groups. In the first group, risk of aneuploidy was assessed using FTCS based on the most recent UK Fetal Medicine Foundation algorithm. In the second group, risk assessment was based on ultrasound findings and cfDNA analysis. An additional tube of blood was collected for FTCS in case the cfDNA analysis was uninformative. Primary outcome was false-positive rate in screening for trisomy 21. A case was considered false positive if the karyotype was not trisomy 21 and if the risk for trisomy 21 was >1:100, irrespective of the method of risk calculation. Results were compared using 95% CIs using the Clopper-Pearson method. RESULTS: Between October 2015 and December 2016, 1518 women with singleton pregnancy underwent first-trimester screening. Thirty-one (2.0%) pregnancies were not eligible for randomization due to increased NT (> 3.5 mm) and/or fetal defect. After exclusion of women who declined randomization (n = 87) and cases of fetal death and loss to follow-up (n = 24), 688 pregnancies were randomized into the FTCS arm and 688 into the ultrasound + cfDNA analysis arm. There were no differences in maternal and gestational age, maternal weight and BMI, ethnicity, use of assisted reproduction and cigarette smoking between the two arms. In the ultrasound + cfDNA analysis arm, median risk for trisomy 21 was 1 in 10 000. None of the cases had a risk above 1: 100 (95% CI, 0.0-0.5%). In the FTCS arm, the median risk for trisomy 21 was 1 in 3787 and in 17 cases, the risk was higher than 1:100, which corresponds to 2.5% (95% CI, 1.5-3.9%) of the FTCS study-arm population. CONCLUSION: Our study has shown that first-trimester risk assessment for trisomy 21 that includes a detailed ultrasound examination as well as NT measurement and is followed by cfDNA testing is associated with a significant reduction in the false-positive rate compared with FTCS. This approach obviates the need for maternal serum free ß-human chorionic gonadotropin and pregnancy-associated plasma protein-A in screening for fetal aneuploidy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ácidos Nucleicos Livres/sangue , Síndrome de Down/diagnóstico , Medição da Translucência Nucal , Adulto , Estatura Cabeça-Cóccix , Síndrome de Down/sangue , Feminino , Humanos , Testes para Triagem do Soro Materno/estatística & dados numéricos , Gravidez , Primeiro Trimestre da Gravidez/sangue , Medição de Risco
8.
Acta Obstet Gynecol Scand ; 95(2): 210-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26445297

RESUMO

INTRODUCTION: We investigated the reliability of fetal thymus measurement during first-trimester screening, and associated fetal thymus size with crown-rump length, maternal diseases and fetal outcome. MATERIAL AND METHODS: In a retrospective cohort of 971 normal singleton first-trimester fetuses, we measured the anterior-posterior diameter of the thymus in a midsagittal plane in 767 fetuses. The intra-observer and inter-observer reliabilities were tested by intra-class correlation coefficient. We correlated thymus size with fetal crown-rump length, and investigated its association with maternal diseases (diabetes mellitus, rheumatic disorders, hypertension and coagulation disorders) and fetal outcome (small for gestational age, preterm birth and umbilical artery pH) using regression analyses. RESULTS: The intra-observer and inter-observer reliabilities of fetal thymus measurement were excellent (intra-class correlation coefficient 0.926, 95% CI 0.745-0.981 and 0.945, 95% CI 0.886-0.993, respectively). A linear relationship was found between crown-rump length and thymus size (ß = 0.023, p = 0.001). Pregnancies affected by maternal diabetes had a decreased fetal thymus size (ß = -0.209, p = 0.001), whereas in pregnancies affected by maternal rheumatic disease the thymus size was increased (ß = 0.285, p < 0.001). Fetal thymus size was not associated with maternal hypertension or maternal coagulation disorders. There was a positive association between preterm birth and fetal thymus size (p < 0.001). CONCLUSION: Measurement of first-trimester thymus size is reliable. Fetal thymus size has a linear correlation with crown-rump length. Maternal diabetes, rheumatic disease and preterm birth appear to have an association with fetal thymus size.


Assuntos
Doenças Fetais/diagnóstico por imagem , Complicações na Gravidez , Timo/diagnóstico por imagem , Timo/embriologia , Ultrassonografia Pré-Natal , Estatura Cabeça-Cóccix , Diabetes Gestacional , Feminino , Humanos , Concentração de Íons de Hidrogênio , Recém-Nascido , Tamanho do Órgão , Gravidez , Primeiro Trimestre da Gravidez , Nascimento Prematuro , Reprodutibilidade dos Testes , Estudos Retrospectivos , Doenças Reumáticas , Fatores de Risco , Artérias Umbilicais
9.
Gynecol Obstet Fertil ; 43(12): 761-6, 2015 Dec.
Artigo em Francês | MEDLINE | ID: mdl-26476892

RESUMO

OBJECTIVES: The objective of this study was to establish a minimum subset of simple criteria for the self-assessment of the quality of first-trimester ultrasound images of nuchal translucency (NT) and crown-rump length (CRL). METHODS: We designed 162 simplified image-scoring methods (ISM) based on 1, 2, 3 or 4 binary criteria derived from the 8 criteria of the original image scoring method of the French College of Fetal Ultrasound (CFEF). These ISM were assessed on 68,250 consecutive scans of the French national audit conducted by the CFEF on NT and CRL images. The ISM associated with the best precision to identify excellent/reasonable quality scans were selected. RESULTS: Simplified ISM based on 1, 2, 3 and 4 criteria showed maximum positive predictive values of 95.3% (95.11-95.50) 98.0% (97.87-98.14), 99.3% (99.17-99.35) and 99.7% (99.68-99.79), respectively, to identify excellent/reasonable quality scans. The proportion of excellent/reasonable scans was 2.8 to 16.7% when three criteria among the 8 were insufficient, and 0.17 to 3.95% when four criteria were insufficient. CONCLUSIONS: The best performing ISM was based on the following four quality criteria: (i) sagittal plane of the NT, (ii) calipers placement for measuring the NT, (iii) image magnification of NT images and (iv) CRL measurement. This score might be the most relevant in clinical practice in the first-trimester screening.


Assuntos
Estatura Cabeça-Cóccix , Idade Gestacional , Medição da Translucência Nucal , Ultrassonografia Pré-Natal , Síndrome de Down/diagnóstico por imagem , Feminino , França , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade
10.
PLoS One ; 10(6): e0131025, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26114295

RESUMO

Estimating gestational age in resource-limited settings is prone to considerable inaccuracy because crown-rump length measured by ultrasound before 14 weeks gestation, the recommended method for estimating gestational age, is often unavailable. Judgements regarding provision of appropriate obstetric and neonatal care are dependent on accurate estimation of gestational age. We determined the accuracy of the Dubowitz Gestational Age Assessment, a population-specific symphysis-fundal height formula, and ultrasound biometry performed between 16 and 40 weeks gestation in estimating gestational age using pre-existing data from antenatal clinics of the Shoklo Malaria Research Unit on the Thai-Myanmar border, where malaria is endemic. Two cohorts of women who gave birth to live singletons were analysed: 1) 250 women who attended antenatal care between July 2001 and May 2006 and had both ultrasound crown-rump length (reference) and a Dubowitz Gestational Age Assessment; 2) 975 women attending antenatal care between April 2007 and October 2010 who had ultrasound crown-rump length, symphysis-fundal measurements, and an additional study ultrasound (biparietal diameter and head circumference) randomly scheduled between 16 and 40 weeks gestation. Mean difference in estimated newborn gestational age between methods and 95% limits of agreement (LOA) were determined from linear mixed-effects models. The Dubowitz method and the symphysis-fundal height formula performed well in term newborns, but overestimated gestational age of preterms by 2.57 weeks (95% LOA: 0.49, 4.65) and 3.94 weeks (95% LOA: 2.50, 5.38), respectively. Biparietal diameter overestimated gestational age by 0.83 weeks (95% LOA: -0.93, 2.58). Head circumference underestimated gestational age by 0.39 weeks (95% LOA: -2.60, 1.82), especially if measured after 24 weeks gestation. The results of this study can be used to quantify biases associated with alternative methods for estimating gestational age in the absence of ultrasound crown-rump length to inform critical clinical judgements in this population, and as a point of reference elsewhere.


Assuntos
Idade Gestacional , Áreas de Pobreza , Cuidado Pré-Natal/estatística & dados numéricos , Ultrassonografia Pré-Natal/métodos , Adolescente , Adulto , Cefalometria/economia , Cefalometria/estatística & dados numéricos , Estatura Cabeça-Cóccix , Feminino , Recursos em Saúde/provisão & distribuição , Humanos , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Mianmar , Cooperação do Paciente , Gravidez , Cuidado Pré-Natal/economia , Estudos Retrospectivos , Tailândia , Ultrassonografia Pré-Natal/economia , Adulto Jovem
11.
J Matern Fetal Neonatal Med ; 28(1): 68-70, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24635416

RESUMO

OBJECTIVE: The purpose of this study was to determine whether fetal heart rate (FHR) can be used to date pregnancies in the early first trimester using the gold standard of crown-rump length (CRL) dating as a reference. METHODS: This single center study evaluated women undergoing obstetrical ultrasounds between 4.5 and 8.5 weeks. FHR and gestational age (GA) based on CRL were obtained. Linear regression analysis and a Bland-Altman plot were used to demonstrate the relationship between the two measurements. A further simplified version of the relationship between CRL and FHR that may be clinically useful was calculated. RESULTS: 176 patients were included in the study. The Pearson correlation coefficient was 0.95, indicating a strong correlation between the two dating methods. The Bland-Altman plot demonstrated agreement across GA tested. A simple arithmetic formula of GA(weeks)=FHR (beats per minute)/20 was calculated. 169/176 patients had <4 days discrepancy between FHR- and CRL-based dating using this formula. CONCLUSION: We found that a simple formula based on FHR may accurately date early pregnancies. This method, if further validated, may represent an important tool for pregnancy dating.


Assuntos
Estatura Cabeça-Cóccix , Idade Gestacional , Frequência Cardíaca Fetal , Ultrassonografia Pré-Natal , Feminino , Humanos , Gravidez , Primeiro Trimestre da Gravidez
12.
Epidemiology ; 25(4): 513-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24807697

RESUMO

BACKGROUND: Estimation of fetal age by ultrasound assumes identical biometries for both sexes at identical gestational ages. However, late in the first trimester male fetuses become larger overall than female fetuses, which may introduce a sex bias with clinical consequences. A recent study showed that using due-date estimates based on biparietal diameter from the second trimester increased the post-term male-to-female ratio and the risk of stillbirth among female fetuses born at 43 gestational weeks. We aimed to evaluate whether this increased male-to-female ratio was also present when the due date was based on crown-rump length from the first trimester. METHODS: The study population included 3987 women with a certain last menstrual period (LMP), as well as a crown-rump length measured in the first trimester and a biparietal diameter measured in the second trimester. We defined birth after 42 completed weeks estimated by LMP as post-term. Labor was not routinely induced until after 42 weeks. Male-to-female ratios were estimated using logistic regression. RESULTS: When gestational age was estimated by biparietal diameter, the sex ratio steadily increased from 0.98 (95% confidence interval = 0.87-1.11) in week 40 to 1.54 (1.09-2.17) in week 42. A similar increase did not occur when using certain LMP or crown-rump length. CONCLUSIONS: The use of crown-rump length for the estimation of gestational age is not associated with an increased post-term male-to-female ratio. It can therefore be used for the estimation of due date without risk of the sex bias that occurs when using biparietal diameter in second trimester of pregnancy.


Assuntos
Idade Gestacional , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Viés , Estatura Cabeça-Cóccix , Feminino , Humanos , Masculino , Fatores Sexuais , Ultrassonografia Pré-Natal/normas
13.
J Obstet Gynaecol Can ; 36(2): 171-181, 2014 02.
Artigo em Inglês | MEDLINE | ID: mdl-24518917

RESUMO

This document has been archived because it contains outdated information. It should not be consulted for clinical use, but for historical research only. Please visit the journal website for the most recent guidelines.


Ce document a été archivé, car il contient des informations périmées. Il ne devrait pas être consulté pour un usage clinique, mais uniquement pour des recherches historiques. Veuillez consulter le site web du journal pour les directives les plus récentes.


Assuntos
Idade Gestacional , Ultrassonografia Pré-Natal , Antropometria/métodos , Análise Custo-Benefício , Estatura Cabeça-Cóccix , Medicina Baseada em Evidências , Feminino , Humanos , MEDLINE , Ciclo Menstrual , Gravidez , Ultrassonografia Pré-Natal/economia , Ultrassonografia Pré-Natal/métodos , Saco Vitelino
14.
Ultrasound Obstet Gynecol ; 43(3): 291-6, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23526790

RESUMO

OBJECTIVE: To evaluate the role of cervical length (CL) and uterine artery pulsatility index (UtA-PI) at 11+0 to 13+6 weeks as predictors of spontaneous preterm delivery (sPTD) in a Chilean population. METHODS: This was a prospective study of asymptomatic women with singleton pregnancies attending for a nuchal translucency scan at 11+0 to 13+6 weeks' gestation and who underwent a transvaginal scan for evaluation of CL and UtA-PI. Exclusion criteria were fetal and pregnancy complications (other than sPTD) and iatrogenic delivery at<34 weeks. Measurements of CL and UtA-PI were adjusted for fetal crown-rump length and maternal characteristics and expressed as multiples of the median (MoM) of the unaffected group. Prediction of sPTD using maternal and pregnancy characteristics was studied using logistic regression analysis. RESULTS: A total of 3480 women were recruited into the study and, after application of exclusion criteria, 3310 were included in the analysis. The rate of sPTD at<34 weeks was 0.9% (n=31). A previous PTD had occurred in 7.4% of parous women. Patients with sPTD in the index pregnancy were characterized by a significantly higher prevalence of previous PTD (12.9% vs 3.7%, P<0.05). No significant difference was found in either CL or UtA-PI between pregnancies with and without subsequent sPTD. Logistic regression analysis showed that smoking and previous PTD were significantly associated with sPTD at<34 weeks. The combination of these characteristics provided a detection rate of 26% with a false-positive rate of 8%. CONCLUSIONS: Neither UtA-PI nor CL during the first trimester was shown to be a useful predictor of early sPTD. However, a combined model that includes smoking and previous PTD predicts approximately one-quarter of those women destined to deliver at<34 weeks, with a false-positive rate of 8%.


Assuntos
Colo do Útero/diagnóstico por imagem , Trabalho de Parto Prematuro/diagnóstico por imagem , Insuficiência Placentária/diagnóstico por imagem , Complicações na Gravidez/diagnóstico por imagem , Nascimento Prematuro , Artéria Uterina/diagnóstico por imagem , Útero/diagnóstico por imagem , Adulto , Colo do Útero/patologia , Estatura Cabeça-Cóccix , Reações Falso-Positivas , Feminino , Humanos , Recém-Nascido , Medição da Translucência Nucal , Insuficiência Placentária/patologia , Valor Preditivo dos Testes , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Curva ROC , Sensibilidade e Especificidade
15.
Best Pract Res Clin Obstet Gynaecol ; 28(2): 201-14, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24355992

RESUMO

Early ultrasound assessment and accurate determination of chorionicity is crucial so that appropriate care of multiple pregnancy can be provided. It is best achieved in the first trimester of pregnancy using the Lambda 'λ' and 'T' signs. Accurate labelling of the twins is needed to ensure that the same individual fetus is measured through the pregnancy so that the longitudinal growth pattern can be correctly assessed. Discrepancy in crown-rump length indicates a possibility for future development of selective intrauterine growth restriction. Careful early ultrasound assessment is needed to identify structural and chromosomal anomalies, as twin pregnancies are at increased risk. Twin-to-twin transfusion syndrome, selective intrauterine growth restriction and congenital abnormalities represent the major determinants of perinatal loss in monochorionic pregnancies, and diagnosis and prognosis are discussed in detail. Treatment of twin reverse arterial perfusion sequence is more effective in early pregnancy, so early identification is needed. Outcome of conjoined twins is guarded, and is dependent on the extent of fusion, degree of sharing of organs, associated anomalies, and presence of cardiac failure in utero.


Assuntos
Gravidez Múltipla , Ultrassonografia Pré-Natal , Transtornos Cromossômicos/diagnóstico por imagem , Anormalidades Congênitas/diagnóstico por imagem , Estatura Cabeça-Cóccix , Diagnóstico Precoce , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Gravidez , Resultado da Gravidez , Primeiro Trimestre da Gravidez , Medição de Risco , Fatores de Risco , Gêmeos Monozigóticos
16.
Rev. bras. cir. cardiovasc ; 28(4): 477-481, out.-dez. 2013. tab
Artigo em Português | LILACS | ID: lil-703115

RESUMO

OBJETIVO: Avaliar a influência do comprimento cabeça-nádega e do índice de massa corporal na avaliação ultrassonográfica do coração fetal, pelas vias abdominal e vaginal, no primeiro trimestre de gestação. MÉTODOS: Realizou-se um estudo de corte transversal com 57 gestantes normais entre 12 a 14 semanas (CCN < 84 mm). Foram avaliados os seguintes planos cardíacos, pelas vias abdominal e vaginal: quatro câmaras, via de saída do ventrículo direito, via de saída do ventrículo esquerdo e arco aórtico. Utilizou-se o modo B, Doppler colorido e ultrassonografia de quarta dimensão (spatio-temporal image correlation). Para avaliar a influência do comprimento cabeça-nádega e índice de massa corporal na avaliação dos planos cardíacos fetal, utilizou-se o teste t não-pareado. RESULTADOS: Não se observou diferenças estaticamente significativas nas taxas de sucesso e insucesso entre as vias abdominal e vaginal em relação ao índice de massa corporal, contudo, observou-se maior taxa de insucesso na avaliação vaginal utilizando o modo B associado ao Doppler colorido (P<0,01). CONCLUSÃO: O índice de massa corporal e o comprimento cabeça-nádega não tiveram interferência na avaliação cardíaca fetal no primeiro trimestre de gestação.


OBJECTIVE: To evaluate the influence of the crown-rump length and body mass index on sonographic evaluation of the fetal heart using abdominal and vaginal routes in the first trimester of pregnancy. METHODS: We conducted a cross-sectional study with 57 pregnant women between 12-14 weeks (CRL< 84 mm). We evaluated the following fetal cardiac plans using the abdominal and vaginal routes: four-chamber view, right ventricle outflow tract, left ventricle outflow tract and aortic arch. We used the B-mode, color Doppler and four-dimensional ultrasonography (spatio-temporal image correlation). To evaluate the influence of crown-rump length and body mass index in the assessment of fetal cardiac planes, we used the t test unpaired. RESULTS: There were no statistically significant differences in the rates of success and failure between abdominal and vaginal routes in relation to body mass index, however, there was a higher failure rate in vaginal assessment using B mode associated with color Doppler (P<0.01). CONCLUSION: The crown-rump length and body mass index had no interference in fetal cardiac assessment in the first trimester of pregnancy.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem , Índice de Massa Corporal , Estatura Cabeça-Cóccix , Coração Fetal/anatomia & histologia , Primeiro Trimestre da Gravidez , Estudos Transversais , Coração Fetal , Idade Gestacional , Estudos Prospectivos , Ultrassonografia Doppler em Cores , Ultrassonografia Pré-Natal/métodos
17.
Theriogenology ; 80(6): 609-18, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23830233

RESUMO

The aims of this study were to determine the developmental patterns of some fetal parts to achieve a high accuracy level in the assessment of gestational age and to assess the feasibility and accuracy of ultrasonic prenatal fetal sex assessment in camels. Serial ultrasonographic examinations were carried out on seven pregnant dromedary camels. A total of 329 ultrasonographic examinations were conducted between the second and the 54th weeks of pregnancy. Intrauterine fluid accumulation was detected between the second and third weeks of pregnancy. The embryo proper was noticed between the third and fourth weeks. Organization of the embryo was first observed between the sixth and seventh weeks. Ossification was first detected between the seventh and ninth weeks. The accessibility during the total gestational period was 35/329 (10.6%) for crown-rump length, 35/329 (10.6%) for biparietal diameter, 42/329 (12.8%) for abdominal diameter, 42/329 (12.8%) for ruminal length, and 126/329 (38.3%) for eyeball diameter. A high correlation was found between gestational age and each of the studied parameters (P < 0.0001). The highest correlation was found with the crown-rump length and the biparietal diameter during the first trimester and with the eyeball diameter during the third trimester of pregnancy. The overall accuracy of the ultrasonic prenatal fetal sex assessment was 91.7%. The best window was found during the 11th week of pregnancy. It was concluded that sonographic fetometry can be useful for the evaluation of fetal development, the estimation of gestational age, and the prediction of prenatal fetal sex in camels.


Assuntos
Camelus , Análise para Determinação do Sexo/veterinária , Ultrassonografia Pré-Natal/veterinária , Animais , Camelus/embriologia , Estatura Cabeça-Cóccix , Estudos de Viabilidade , Feminino , Desenvolvimento Fetal , Feto/anatomia & histologia , Masculino , Gravidez , Análise para Determinação do Sexo/métodos
18.
Fetal Diagn Ther ; 34(2): 90-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23751732

RESUMO

INTRODUCTION: The primary aim of this study was to assess the interobserver and intraobserver reproducibility of the first-trimester frontomaxillary facial angle (FMFA) measurement using both 2D and 3D ultrasound. Assessment of the relationship between crown-to-rump length (CRL) and FMFA measurement was also reviewed. MATERIALS AND METHODS: Two experienced operators imaged the same 30 patients over a 1-month period collecting both 2D static images and 3D volumes during nuchal translucency assessment at 11-14 weeks' gestation. The operators were blinded to each other's images and results. RESULTS: The mean 2D FMFA measurement was 88.0° and 88.4° for observer 1 and 2, respectively; while the mean 3D FMFA measurement was 87.8° and 88.0°, respectively. Intraclass correlation suggests good intraobserver and interobserver agreement with no statistically significant difference between operators in either 2D (p = 0.14) or 3D (p = 0.11) measurements. The FMFA was unchanged with increasing CRL. DISCUSSION: Both 2D and 3D FMFA measurements have been demonstrated to be equivalent and reliable. Strict image acquisition criteria must be followed for accurate and reproducible FMFA measurements. There was no change demonstrated in FMFA measurement with increasing CRL.


Assuntos
Síndrome de Down/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Aneuploidia , Estudos de Coortes , Estatura Cabeça-Cóccix , Feminino , Humanos , Imageamento Tridimensional/métodos , Medição da Translucência Nucal , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
Prenat Diagn ; 33(8): 764-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23553794

RESUMO

OBJECTIVES: The aim of this study was to clarify the effects of umbilical cord coiling on the umbilical blood flow at 11-13 weeks of gestation. METHODS: A cross-sectional study was conducted among consecutive pregnant females at 11-13 weeks of gestation. Transabdominal ultrasound examinations were performed to obtain the umbilical coiling index (CI), the maximum umbilical arterial peak velocity at the free loop, the venous velocities at the free loop and the umbilical ring, and the umbilical arterial and venous flow volumes. After every measurement was standardized according to the crown-rump length (CRL), correlations between the CI and these measurements were analyzed. RESULTS: A total of 364 subjects were enrolled. The CI significantly decreased in association with advancing gestation. There were significant correlations between the CRLs and the umbilical arterial peak velocities, the venous velocities at the free loop and the umbilical ring, and the umbilical arterial and venous flow volumes. The z-scores of the umbilical arterial and venous velocimetries exhibited no significant correlations with the CI. The umbilical arterial and venous flow volumes were also not found to correlate with the CI. CONCLUSIONS: The CI does not affect either the umbilical arterial or venous blood flow at 11-13 weeks of gestation.


Assuntos
Indicadores Básicos de Saúde , Primeiro Trimestre da Gravidez , Cordão Umbilical/anatomia & histologia , Cordão Umbilical/irrigação sanguínea , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Volume Sanguíneo/fisiologia , Estudos Transversais , Estatura Cabeça-Cóccix , Feminino , Sangue Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Gravidez , Primeiro Trimestre da Gravidez/fisiologia , Ultrassonografia Pré-Natal , Artérias Umbilicais/anatomia & histologia , Artérias Umbilicais/diagnóstico por imagem , Cordão Umbilical/diagnóstico por imagem
20.
Diabet Med ; 30(7): 818-24, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23330615

RESUMO

AIM: Diabetic ketoacidosis is a life-threatening complication of Type 1 diabetes. Blood ß-hydroxybutyrate testing is now widely available as an alternative to urine acetoacetate testing for detecting ketosis. The aim of this study was to review the effectiveness of capillary or serum ß-hydroxybutyrate compared with urine acetoacetate testing in prevention and management of diabetic ketoacidosis. METHODS: MEDLINE, EMBASE, EBM Reviews, The Cochrane Library and CINAHL (until April 2012, no language restrictions, studies in humans) were searched for experimental and observational studies comparing the effectiveness of blood ß-hydroxybutyrate and urine acetoacetate testing. Outcomes examined were prevention of diabetic ketoacidosis, time to recovery from diabetic ketoacidosis, healthcare costs and patient or caregiver satisfaction. Additional sources included reference lists, conference proceedings and contact with experts in the field. RESULTS: Four studies (two randomized controlled trials and two cohort studies) met eligibility criteria, including 299 participants across 11 centres. Risk of bias was low to moderate. Blood ketone testing compared with urine testing was associated with reduced frequency of hospitalization (one study), reduced time to recovery from diabetic ketoacidosis (three studies), cost benefits (one study) and greater satisfaction (one study, intervention group only). No study assessed prevention of diabetic ketoacidosis. Meta-analysis could not be performed because of heterogeneity in study design and published data. CONCLUSIONS: There is evidence suggesting that blood ß-hydroxybutyrate testing is more effective than urine acetoacetate testing in reducing emergency department assessment, hospitalization and time to recovery from diabetic ketoacidosis, as well as potentially lowering healthcare expenditure. Further research in both young people and adults is needed.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Acetoacetatos/urina , Diabetes Mellitus Tipo 1/complicações , Cetoacidose Diabética/prevenção & controle , Cetoacidose Diabética/terapia , Cuidados Críticos/economia , Estatura Cabeça-Cóccix , Cetoacidose Diabética/economia , Gastos em Saúde , Hospitalização/economia , Humanos , MEDLINE , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA