Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 470
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 17(4): e013702, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38525609

RESUMO

BACKGROUND: Intravascular imaging and intracoronary physiology may both be used to guide and optimize percutaneous coronary intervention; however, they are rarely used together. The virtual flow reserve (VFR) is an optical coherence tomography (OCT)-based model of fractional flow reserve (FFR) facilitating the assessment of the physiological significance of coronary lesions. We aimed to validate the VFR assessment of intermediate coronary artery stenoses. METHODS: FUSION (Validation of OCT-Based Functional Diagnosis of Coronary Stenosis) was a multicenter, prospective, observational study comparing OCT-derived VFR to invasive FFR. VFR was mathematically derived from a lumped parameter flow model based on 3-dimensional lumen morphology. Patients undergoing coronary angiography with intermediate angiographic stenosis (40%-90%) requiring physiological assessment were enrolled. Investigational sites were blinded to the VFR analysis, and all OCT and FFR data were reviewed by an independent core laboratory. The coprimary end points were the sensitivity and specificity of VFR against FFR as the reference standard, each of which was tested against prespecified performance goals. RESULTS: After core laboratory review, 266 vessels in 224 patients from 25 US centers were included in the analysis. The mean angiographic diameter stenosis was 65.5%±14.9%, and the mean FFR was 0.83±0.11. Overall accuracy, sensitivity, and specificity of VFR versus FFR using a binary cutoff point of 0.80 were 82.0%, 80.4%, and 82.9%, respectively. The 97.5% lower confidence bound met the prespecified performance goal for sensitivity (71.6% versus 70%; P=0.01) and specificity (76.6% versus 75%; P=0.01). The area under the curve was 0.88 (95% CI, 0.84-0.92; P<0.0001). CONCLUSIONS: OCT-derived VFR demonstrates high sensitivity and specificity for predicting invasive FFR. Integrating high-resolution intravascular imaging with imaging-derived physiology may provide synergistic benefits as an adjunct to percutaneous coronary intervention. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04356027.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Constrição Patológica , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Resultado do Tratamento , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Vasos Coronários , Valor Preditivo dos Testes , Índice de Gravidade de Doença
2.
Radiology ; 310(2): e231956, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38376407

RESUMO

Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária
3.
Int J Cardiol ; 400: 131765, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211669

RESUMO

BACKGROUND: Ultrasonic flow ratio (UFR) is a novel intravascular ultrasound (IVUS)-derived modality for fast computation of fractional flow reserve (FFR) without pressure wires and adenosine. AIMS: This study was sought to compare the diagnostic performance of UFR and quantitative flow ratio (QFR), using FFR as the reference standard. METHODS: This is a retrospective study enrolling consecutive patients with intermediate coronary artery lesions (diameter stenosis of 30%-90% by visual estimation) for IVUS and FFR measurement. UFR and QFR were performed offline in a core-lab by independent analysts blinded to FFR. RESULTS: From December 2022 to May 2023, a total of 78 eligible patients were enrolled. IVUS and FFR measurements were successfully conducted in 104 vessels, finally 98 vessels with both FFR, UFR and QFR evaluation were analyzed. Mean FFR was 0.79 ± 0.12. UFR showed a strong correlation with FFR similar to QFR (r = 0.83 vs. 0.82, p = 0.795). Diagnostic accuracy of UFR was non-inferior to QFR (94% [89%-97%] versus 90% [84%-94%], p = 0.113). Sensitivity and specificity in identifying hemodynamically significant stenosis were comparable between UFR and QFR (sensitivity: 89% [79%-96%] versus 85% [74%-92%], p = 0.453; specificity: 97% [91%-99%] versus 95% [88%-99%], p = 0.625). The area under curve for UFR was 0.95 [0.90-0.98], non-inferior to QFR (difference = 0.021, p = 0.293), and significantly higher than minimum lumen area (MLA; difference = 0.13, p < 0.001). Diagnostic accuracy of UFR and QFR was not statically different in bifurcation nor non-bifurcation lesions. CONCLUSIONS: UFR showed excellent concordance with FFR, non-inferior to QFR, superior to MLA. UFR provides a potentiality for the integration of physiological assessment and intravascular imaging in clinical practice.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estudos Retrospectivos , Constrição Patológica , Ultrassom , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes , Índice de Gravidade de Doença
4.
Eur J Vasc Endovasc Surg ; 67(2): 332-340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37500005

RESUMO

OBJECTIVE: Peripheral arterial stenoses (PAS) are commonly investigated with duplex ultrasound (DUS) and angiography, but these are not functional tests. Fractional flow reserve (FFR), a pressure based index, functionally assesses the ischaemic potential of coronary stenoses, but its utility in PAS is unknown. FFR in the peripheral vasculature in patients with limb ischaemia was investigated. METHODS: Patients scheduled for angioplasty and or stenting of isolated iliac and superficial femoral artery stenoses were recruited. Resting trans-lesional pressure gradient (Pd/Pa) and FFR were measured after adenosine provoked hyperaemia using an intra-arterial 0.014 inch flow and pressure sensing wire (ComboWire XT, Philips). Prior to revascularisation, exercise ABPI (eABPI) and DUS derived peak systolic velocity ratio (PSVR) of the index lesion were determined. Calf muscle oxygenation was measured using blood oxygenation level dependent cardiovascular magnetic resonance prior to and after revascularisation. RESULTS: Forty-one patients (32, 78%, male, mean age 65 ± 11 years) with 61 stenoses (iliac 32; femoral 29) were studied. For lesions < 80% stenosis, resting Pd/Pa was not influenced by the degree of stenosis (p = .074); however, FFR was discriminatory, decreasing as the severity of stenosis increased (p = .019). An FFR of < 0.60 was associated with critical limb threatening ischaemia (area under the curve [AUC] 0.87; 95% CI 0.75 - 0.95), in this study performing better than angiographic % stenosis (0.79; 0.63 - 0.89), eABPI (0.72; 0.57 - 0.83), and PSVR (0.65; 0.51 - 0.78). FFR correlated strongly with calf oxygenation (rho, 0.76; p < .001). A greater increase in FFR signalled resolution of symptoms and signs (ΔFFR 0.25 ± 0.15 vs. 0.13 ± 0.09; p = .009) and a post-angioplasty and stenting FFR of > 0.74 predicted successful revascularisation (combined sensitivity and specificity of 95%; AUC 0.98; 0.91 - 1.00). CONCLUSION: This pilot study demonstrates that FFR can objectively measure the functional significance of PAS that compares favourably with visual and DUS based assessments. Its role as a quality control adjunct that confirms optimal vessel patency after angioplasty and or stenting also merits further investigation.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Constrição Patológica , Angiografia Coronária , Projetos Piloto , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Índice de Gravidade de Doença , Valor Preditivo dos Testes
6.
Forensic Sci Int ; 353: 111878, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37980856

RESUMO

BACKGROUND: A 3D sequence was introduced to unenhanced post-mortem cardiac magnetic resonance imaging (PMCMR) to enable multiplanar coronary artery image analysis and to investigate its diagnostic accuracy for the diagnosis of coronary artery stenosis and thrombosis. MATERIALS AND METHODS: N = 200 forensic cases with suspected coronary artery pathology underwent 3 Tesla PMCMR (sequence used: T2 weighted transversal 3D turbo spin echo) before autopsy. Main coronary artery stenosis and thrombosis were assessed in PMCMR by multiplanar image analysis by two observers. Coronary artery histology was determined as the gold standard and compared to PMCMR. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) with 95% confidence intervals were calculated. RESULTS: For all coronary arteries combined, sensitivity was 75% (PPV 73%) for the diagnosis of stenosis and 72% (PPV 71%) for the diagnosis of thrombosis. Specificity was 92% (NPV 90%) for correct diagnosis of non-existing stenosis and 97% (NPV 97%) for non-existing thrombosis. Sensitivity for correct diagnosis of different degrees of stenosis ranged between 67% and 80% (PPVs 67-82%); specificity ranged between 96% and 99% (NPVs 96-99%). CONCLUSION: Multiplanar PMCMR coronary artery stenosis and thrombosis assessment based on an unenhanced T2 weighted 3D sequence provide moderate sensitivity and high specificity for the diagnosis of coronary artery stenosis and/or thrombosis. Hence, 3D T2w PMCMR cannot reliably detect existing coronary artery stenosis and thrombosis but may be particularly useful for the exclusion of stenosis or thrombosis of the main coronary arteries.


Assuntos
Estenose Coronária , Trombose , Humanos , Constrição Patológica , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Trombose/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem
7.
Circ Cardiovasc Interv ; 16(10): e013185, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37712285

RESUMO

BACKGROUND: Angiography-derived computational physiology is an appealing alternative to pressure-wire coronary physiology assessment. However, little is known about its reliability in the setting of severe aortic stenosis. This study sought to provide an integrated assessment of epicardial and microvascular coronary circulation by means of single-view angiography-derived physiology in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). METHODS: Pre-TAVI angiographic projections of 198 stenotic coronary arteries (123 patients) were analyzed by means of Murray's law-based quantitative flow ratio and angiography microvascular resistance. Wire-based reference measurements were available for comparison: fractional flow reserve (FFR) in all cases, instantaneous wave-free ratio in 148, and index of microvascular resistance in 42 arteries. RESULTS: No difference in terms of the number of ischemia-causing stenoses was detected between FFR ≤0.80 and Murray's law-based quantitative flow ratio ≤0.80 (19.7% versus 19.2%; P=0.899), while this was significantly higher when instantaneous wave-free ratio ≤0.89 (44.6%; P=0.001) was used. The accuracy of Murray's law-based quantitative flow ratio ≤0.80 in predicting pre-TAVI FFR ≤0.80 was significantly higher than the accuracy of instantaneous wave-free ratio ≤0.89 (93.4% versus 77.0%; P=0.001), driven by a higher positive predictive value (86.9% versus 50%). Similar findings were observed when considering post-TAVI FFR ≤0.80 as reference. In 82 cases with post-TAVI angiographic projections, Murray's law-based quantitative flow ratio values remained stable, with a low rate of reclassification of stenosis significance (9.9%), similar to FFR and instantaneous wave-free ratio. Angiography microvascular resistance demonstrated a significant correlation (Rho=0.458; P=0.002) with index of microvascular resistance, showing an area under the curve of 0.887 (95% CI, 0.752-0.964) in predicting index of microvascular resistance ≥25. CONCLUSIONS: Angiography-derived physiology provides a valid, reliable, and systematic assessment of the coronary circulation in a complex scenario, such as severe aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Reprodutibilidade dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Índice de Gravidade de Doença
8.
Int J Cardiovasc Imaging ; 39(12): 2465-2474, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37728801

RESUMO

Speckle tracking echocardiography (STE) derived longitudinal strain (LS) and noninvasive pressure-strain loop (PSL) derived myocardial work (MW) are more sensitive than conventional echocardiographic parameters in quantitative assessment of early myocardial dysfunction. The aim of this study was to assess left ventricular (LV) global and regional myocardial function in symptomatic chronic coronary syndrome (CCS) patients using the two promising methods. Transthoracic echocardiography was performed on patients with angina or equivalent symptoms before coronary angiography. STE-based LS and PSL-based MW analysis were carried out on each patient for global and regional myocardial function assessment. A total of 102 patients were classified into significant and nonsignificant coronary artery stenosis (CAS) groups. Among global myocardial function parameters, LS had the biggest area under the curve (AUC) of 0.735, with cutoff value of 18.4% (sensitivity, 79.6%; specificity, 72.9%), but remained statistically alike with all MW indices in predicting significant CAS (P>0.05 for all). Among regional myocardial function parameters, both LS and MW indices had predictive value for significant left anterior descending artery (LAD) or left circumflex artery (LCX) stenosis, while only myocardial work efficiency (MWE) for right coronary artery (RCA) stenosis. Both global and regional LS and MW have predictive value for significant CAS, but their value of regionalized assessment varies with specific coronary artery involvement.


Assuntos
Estenose Coronária , Ecocardiografia , Humanos , Constrição Patológica , Valor Preditivo dos Testes , Ecocardiografia/métodos , Estenose Coronária/diagnóstico por imagem , Angiografia Coronária , Síndrome , Função Ventricular Esquerda
11.
EuroIntervention ; 19(3): 203-221, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37326378

RESUMO

Over the last decade, steady progress has been made in the ability to assess coronary stenosis relevance by merging computerised analyses of angiograms with fluid dynamic modelling. The new field of functional coronary angiography (FCA) has attracted the attention of both clinical and interventional cardiologists as it anticipates a new era of facilitated physiological assessment of coronary artery disease, without the need for intracoronary instrumentation or vasodilator drug administration, and an increased adoption of ischaemia-driven revascularisation. This state-of-the-art review performs a deep dive into the foundations and rationale behind FCA indices derived from either invasive or computed angiograms. We discuss the currently available FCA systems, the evidence supporting their use, and the specific clinical scenarios in which FCA might facilitate patient management. Finally, the rapidly growing application of FCA to the diagnosis of coronary microvascular dysfunction is discussed. Overall, we aim to provide a state-of-the-art review not only to digest the achievements made so far in FCA, but also to enable the reader to follow the many publications and developments in this field that will likely take place in years to come.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Isquemia Miocárdica , Humanos , Angiografia Coronária , Microcirculação , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Circulação Coronária
12.
JACC Cardiovasc Interv ; 16(14): 1778-1790, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37191608

RESUMO

BACKGROUND: Software to compute angiography-derived fractional flow reserve (angio-FFR) have been validated against pressure wire-derived fractional flow reserve (PW-FFR) with an area under the receiver-operating characteristic curve (AUC) of 0.93 to 0.97. OBJECTIVES: The aim of this study was to investigate diagnostic accuracies of 5 angio-FFR software/methods by an independent core lab in a prospective cohort of 390 vessels with carefully documented sites of PW-FFR and pressure wire-derived instantaneous wave-free ratio. METHODS: One "matcher investigator" colocalized on angiography the sites of pressure wire measurement with angio-FFR measurements and provided the same 2 optimal angiographic views and frame selection to independent analysts who were blinded to invasive physiological results and results from other software. The results were anonymized and randomly presented. The AUC of each angio-FFR was compared with 2-dimensional quantitative coronary angiography (QCA) percent diameter stenosis (%DS) using a 2-tailed paired comparison of AUC. RESULTS: All 5 software/methods yielded a high proportion of analyzable vessels (A: 100%, B: 100%, C: 92.1%, D: 99.5%, and E: 92.1%). The AUCs for predicting fractional flow reserve ≤0.8 for software A, B, C, D, E, and 2-dimensional QCA %DS were 0.75, 0.74, 0.74, 0.73, 0.73, and 0.65, respectively. The AUC for each angio-FFR was significantly greater than that for 2-dimensional QCA %DS. CONCLUSIONS: This head-to-head comparison by an independent core lab demonstrated that the diagnostic accuracy of various angio-FFR software for predicting PW-FFR ≤0.80 was useful, with a higher discrimination compared with 2-dimensional QCA %DS; however, it did not reach the diagnostic accuracy previously reported in validation studies of various vendors. Therefore, the intrinsic clinical value of "angiography-derived fractional flow reserve" requires confirmation in large clinical trials.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estudos Prospectivos , Resultado do Tratamento , Angiografia Coronária/métodos , Software , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Vasos Coronários/diagnóstico por imagem
15.
JACC Cardiovasc Imaging ; 16(8): 1056-1065, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37052559

RESUMO

BACKGROUND: Fractional flow reserve-computed tomography (FFR-CT) is endorsed by UK and U.S. chest pain guidelines, but its clinical effectiveness and cost benefit in real-world practice are unknown. OBJECTIVES: The purpose of this study was to audit the use of FFR-CT in clinical practice against England's National Institute for Health and Care Excellence guidance and assess its diagnostic accuracy and cost. METHODS: A multicenter audit was undertaken covering the 3 years when FFR-CT was centrally funded in England. For coronary computed tomographic angiograms (CCTAs) submitted for FFR-CT analysis, centers provided data on symptoms, CCTA and FFR-CT findings, and subsequent management. Audit standards included using FFR-CT only in patients with stable chest pain and equivocal stenosis (50%-69%). Diagnostic accuracy was evaluated against invasive FFR, when performed. Follow-up for nonfatal myocardial infarction and all-cause mortality was undertaken. The cost of an FFR-CT strategy was compared to alternative stress imaging pathways using cost analysis modeling. RESULTS: A total of 2,298 CCTAs from 12 centers underwent FFR-CT analysis. Stable chest pain was the main symptom in 77%, and 40% had equivocal stenosis. Positive and negative predictive values of FFR-CT were 49% and 76%, respectively. A total of 46 events (2%) occurred over a mean follow-up period of 17 months; FFR-CT (cutoff: 0.80) was not predictive. The FFR-CT strategy costs £2,102 per patient compared with an average of £1,411 for stress imaging. CONCLUSIONS: In clinical practice, the National Institute for Health and Care Excellence criteria for using FFR-CT were met in three-fourths of patients for symptoms and 40% for stenosis. FFR-CT had a low positive predictive value, making its use potentially more expensive than conventional stress imaging strategies.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Constrição Patológica , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Dor no Peito , Custos e Análise de Custo , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia
16.
J Cardiovasc Transl Res ; 16(4): 905-915, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36913125

RESUMO

This study was designed to compare the diagnostic performance of angio-FFR and CT-FFR for detecting hemodynamically significant coronary stenosis. Angio-FFR and CT-FFR were measured in 110 patients (139 vessels) with stable coronary disease using invasive FFR as the reference standard. On per-patient basis, angio-FFR was highly correlated with FFR (r =0.78, p <0.001), while the correlation was moderate between CT-FFR and FFR (r =0.68, p <0.001). Diagnostic accuracy, sensitivity, and specificity for angio-FFR were 94.6%, 91.4%, and 96.0%, respectively; and those of CT-FFR were 91.8%, 91.4%, and 92%, respectively. Bland-Altman analysis showed that angio-FFR had a larger average difference and a smaller root mean squared deviation than CT-FFR compared with FFR (-0.014±0.056 vs. 0.0003±0.072). Angio-FFR had a slightly higher AUC than that of CT-FFR (0.946 vs. 0.935, p =0.750). Angio-FFR and CT-FFR computed from coronary images could be accurate and efficient computational tools for detecting lesion-specific ischemia of coronary artery stenosis. Angio-FFR and CT-FFR calculated based on the two types of images can both accurately diagnose functional ischemia of coronary stenosis. CT-FFR can act as a gatekeeper to the catheter room, assisting doctors in determining whether patients need to be screened by coronary angiography. Angio-FFR can be used in the catheter room to determine the functional significant stenosis for helping decision-making in revascularization.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Angiografia Coronária/métodos , Sensibilidade e Especificidade , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
17.
Coron Artery Dis ; 34(3): 167-176, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36762665

RESUMO

BACKGROUND: Cardiac computed tomography angiography (CCTA) is precise in noninvasive coronary atherosclerosis characterization but its value in the diagnosis of intracoronary thrombus remains unknown. Therefore, our aim was to evaluate CCTA for intracoronary thrombus and stenosis detection in patients with acute coronary syndromes with high thrombus burden selected for a deferred stenting strategy. METHODS: We systematically performed a CCTA in consecutive patients following a deferred stenting strategy, 24 h before the scheduled repeated coronary angiography including optical coherence tomography (OCT) imaging. Intracoronary thrombus and residual stenosis were blindly and independently evaluated by both techniques. Agreement was determined per lesion using the weighted Kappa ( K ) coefficient and absolute intraclass correlation coefficient (ICC). A stratified analysis according to OCT-detected thrombus burden was also performed. RESULTS: Thirty lesions in 28 consecutive patients were analyzed. Concordance between CCTA and repeated coronary angiography in thrombus detection was good ( K = 0.554; P < 0.001), but both showed poor agreement with OCT. CCTA needed >11.5% thrombus burden on OCT to obtain adequate diagnostic accuracy. The lesions detected by angiography were more frequently classified as red thrombus (76.5 vs. 33.3%; P = 0.087) on OCT. CCTA showed an excellent concordance with coronary angiography in diameter measurement (ICC = 0.85; P < 0.001) and was able to identify all the patients with severe residual stenosis. CONCLUSIONS: Although CCTA showed just a good concordance with angiography in intracoronary thrombus detection, the agreement in residual stenosis was excellent. Thus, in patients with a high-thrombus burden selected for a deferred stenting strategy CCTA may substitute repeat angiography.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Trombose Coronária , Humanos , Angiografia por Tomografia Computadorizada , Estudos Prospectivos , Constrição Patológica , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Angiografia Coronária/métodos , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Valor Preditivo dos Testes
18.
EuroIntervention ; 18(16): e1348-e1356, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36534493

RESUMO

BACKGROUND: Myocardial ischaemia with non-obstructive coronary arteries (INOCA) represents a challenging and frequent, but largely underdiagnosed, condition. AIMS: We aimed to investigate the feasibility and diagnostic value of angiography-derived coronary microcirculatory resistance in patients with INOCA syndrome. METHODS: This is an investigator-driven, prospective and blinded study. The diagnostic yield of angiography-derived index of coronary microcirculatory resistance (angio-IMR) was investigated against thermodilution-derived IMR (thermo-IMR) in patients with clinically indicated coronary angiography due to suspected myocardial ischaemia and angiographically normal or non-obstructive coronary arteries. The angio-IMR was derived from resting angiograms (contrast-flow angio-IMR [cAngio-IMR]) by an expert analyst blinded to the thermo-IMR. An independent, blinded, physiology core laboratory analysed the raw intracoronary physiology data and provided the final thermo-IMR values. RESULTS: A total of 104 patients (108 coronary vessels) were analysed after fulfilling predefined inclusion criteria. Most patients were female (67%). Obstructive epicardial disease was angiographically (percent diameter stenosis <50%) and physiologically (fractional flow reserve>0.80) ruled out in all cases. Median thermo-IMR and cAngio-IMR were 16.6 (12.7, 23.0) and 16.8 (12.8, 23.1) units, respectively (median difference -0.31, 95% confidence interval: -1.53 to 1.00; p=0.654). cAngio-IMR showed good correlation (Pearson coefficient 0.76; p<0.001), agreement (mean bias 0.4), discriminatory power (area under the curve from the receiver operator characteristics 0.865; p<0.001) and accuracy (85%), compared to thermo-IMR (≥25 U). CONCLUSIONS: Evaluating coronary microcirculatory resistance in patients with INOCA syndrome using cAngio-IMR is feasible and accurate. By circumventing the need of coronary instrumentation and hyperaemic drugs, this method may facilitate the assessment of coronary microcirculatory resistance in patients with suspected INOCA. CLINICALTRIALS: gov: NCT04827498.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Feminino , Humanos , Masculino , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Microcirculação/fisiologia , Isquemia Miocárdica/diagnóstico por imagem , Estudos Prospectivos , Resistência Vascular
19.
Perfusion ; 38(7): 1453-1460, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35817556

RESUMO

INTRODUCTION: To evaluate the effect of the cardiac cycle for the coronary artery opening and coronary stenosis at the plaque to determine the phase of measuring maximum diameters required for coronary artery disease (CAD). METHODS: This retrospective study assessed data for 208 consecutive patients who underwent coronary computed tomography angiography (CTA). The cross-sectional area and diameters of the opening of the left main coronary artery (LM), left anterior descending branch (LAD), left circumflex branch (LCX) and right coronary artery (RCA), the stenosis rate of involved vessels were measured in 10 cardiac cycles. And all their dynamic changes were estimated by the linear mixed model. The relationship between stenosis rate and opening orifice were analyzed by monofactorial variance. RESULTS: The opening parameters and stenosis rate of the four main coronary arteries varied within the cardiac cycle (p < .05). The maximum opening area occurred at the 45%-55% phase; The range of stenosis rate varied approximately 11%-14% and the maximum stenosis rate was at the 65% phase. The degree of vascular stenosis for LM, LAD and LCX were not associated with their corresponding opening diameters, but were positively intercorrelation with each other. CONCLUSION: For patients with CAD, the maximum coronary artery stenosis rate were at 65% phase and the maximum value of coronary artery opening were at 45%-55% phase, which were chosen for the appropriate measurement and evaluation by CTA.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Vasos Coronários/diagnóstico por imagem , Estudos Retrospectivos , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem
20.
Circ Cardiovasc Interv ; 15(11): 861-871, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36111801

RESUMO

BACKGROUND: There is little information available on agreement between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) in left main coronary artery (LMCA) intermediate stenosis. Besides, several meta-analyses support the use of FFR to guide LMCA revascularization, but limited information is available on iFR in this setting. Our aims were to establish the concordance between FFR and iFR in intermediate LMCA lesions, to evaluate with intravascular ultrasound (IVUS) in cases of FFR/iFR discordance, and to prospectively validate the safety of deferring revascularization based on a hybrid decision-making strategy combining iFR and IVUS. METHODS: Prospective, observational, multicenter registry with 300 consecutive patients with intermediate LMCA stenosis who underwent FFR and iFR and, in case of discordance, IVUS and minimal lumen area measurements. Primary clinical end point was a composite of cardiovascular death, LMCA lesion-related nonfatal myocardial infarction, or unplanned LMCA revascularization. RESULTS: FFR and iFR had an agreement of 80% (both positive in 67 and both negative in 167 patients); in case of disagreement (31 FFR+/iFR- and 29 FFR-/iFR+) minimal lumen area was ≥6 mm2 in 8.7% of patients with FFR+ and 14.6% with iFR+. Among the 300 patients, 105 (35%) underwent revascularization and 181 (60%) were deferred according to iFR and IVUS. At a median follow-up of 20 months, major adverse cardiac events incidence was 8.3% in the defer group and 13.3% in the revascularization group (hazard ratio, 0.71 [95% CI 0.30-1.72]; P=0.45). CONCLUSIONS: In patients with intermediate LMCA stenosis, a physiology-guided treatment decision is feasible either with FFR or iFR with moderate concordance between both indices. In case of disagreement, the use of IVUS may be useful to indicate revascularization. Deferral of revascularization based on iFR appears to be safe in terms of major adverse cardiac events. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03767621.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Prognóstico , Angiografia Coronária , Estudos Prospectivos , Constrição Patológica , Resultado do Tratamento , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Índice de Gravidade de Doença , Ultrassonografia de Intervenção , Valor Preditivo dos Testes , Cateterismo Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA