1.
J Korean Med Sci ; 39(17): e152, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711317

RESUMO

BACKGROUND: The rapid economic development of South Korea provides a unique model to study changes in the clinical characteristics, treatment approaches, and clinical outcomes of patients with rheumatic mitral stenosis (MS) relative to socioeconomic growth. METHODS: From the Multicenter mitrAl STEnosis with Rheumatic etiology (MASTER) registry, 2,337 patients diagnosed with moderate or severe rheumatic MS between January 2001 and December 2020 were analyzed. Patients were grouped into consecutive 5-year intervals based on their year of diagnosis. Clinical characteristics, echocardiographic data, and clinical outcomes were assessed. RESULTS: Over 20 years, the severity of mitral stenosis increased from 79.1% to 90.2%; similarly, the average age at diagnosis increased from 54.3 to 63.0 years (all P < 0.001). Comorbidities such as hypertension and atrial fibrillation increased (6.3% to 29.5% and 41.4% to 46.9%, respectively; all P for trend < 0.05). The rate of mitral intervention within five years after diagnosis increased from 31.2% to 47.4% (P for trend < 0.001). However, clinical outcomes of rheumatic mitral stenosis deteriorated over time in the composite outcomes (log-rank test, P < 0.001). Conversely, the incidence of stroke remained stable (60.6-73.7%; P < 0.001), which might be attributed to the increased use of anticoagulation therapy. CONCLUSION: This study observed an increase in patient age, comorbidities, and valve disease severity as the country transitioned from a developing to developed status. Despite a rise in mitral valve interventions, clinical outcomes deteriorated over 20 years, highlighting the need for modified treatment approaches to improve patient outcomes.


Assuntos
Ecocardiografia , Estenose da Valva Mitral , Sistema de Registros , Cardiopatia Reumática , Humanos , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/patologia , Masculino , República da Coreia/epidemiologia , Feminino , Pessoa de Meia-Idade , Cardiopatia Reumática/epidemiologia , Cardiopatia Reumática/diagnóstico , Resultado do Tratamento , Adulto , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Idoso , Índice de Gravidade de Doença , Comorbidade , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia
2.
J Am Heart Assoc ; 13(3): e030540, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38240203

RESUMO

BACKGROUND: Aortic valve calcium score is associated with hemodynamic severity of aortic stenosis. Whether this association is present in calcific mitral stenosis remains unknown. METHODS AND RESULTS: This study was a retrospective analysis of consecutive patients with mitral stenosis secondary to mitral annular calcification (MAC) undergoing transseptal catheterization. All patients underwent invasive mitral valve assessment via direct left atrial and left ventricular pressure measurement. Computed tomography within 1 year of cardiac catheterization and with adequate visualization of the mitral annulus was included. MAC calcium score quantification by Agatston method was obtained offline using dedicated software (Aquarius, TeraRecon, V.4). Median patient age was 66.9±11.2 years, 47% of patients were women, 50% had coronary artery disease, 40% had atrial fibrillation, 47% had prior cardiac surgery, and 33% had prior chest radiation. Median diastolic mitral valve gradient was 9.4±3.4 mm Hg on echocardiography and 8.5±4 mm Hg invasively. Invasive median mitral valve area using the Gorlin formula was 1.87±0.9 cm2. Median MAC calcium score for the cohort was 7280±7937 Hounsfield units. MAC calcium score correlated with the presence of atrial fibrillation (P=0.02) but was not associated with other comorbidities. There was no correlation between MAC calcium score and mitral valve area (r=0.07; P=0.6) or mitral valve gradient (r=-0.03; P=0.8). CONCLUSIONS: MAC calcium score did not correlate with invasively measured mitral valve gradient and mitral valve area in patients with MAC-related mitral stenosis, suggesting that calcium score should not be used as a surrogate for invasive hemodynamic parameters.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Calcinose , Doenças das Valvas Cardíacas , Estenose da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estenose da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Cálcio , Estudos Retrospectivos , Fibrilação Atrial/complicações , Doenças das Valvas Cardíacas/complicações , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Constrição Patológica , Hemodinâmica , Cateterismo Cardíaco
3.
Int J Cardiovasc Imaging ; 39(12): 2419-2426, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37658988

RESUMO

PURPOSE: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS). METHODS: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM). RESULTS: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm² or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm² for RT3D and 0.5 cm² for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm² for RT3D and 0.6 cm² for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm². Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm² vs. 0.26 cm², p = 0.009) but significantly underestimated MVA (1.3 ± 0.4 cm² vs. 1.4 ± 0.4 cm², p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm² vs. 0.18 cm², p = 0.02) or EG3D (0.27 cm² vs. 0.16 cm², p < 0.001). CONCLUSION: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.


Assuntos
Ecocardiografia Tridimensional , Estenose da Valva Mitral , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Ecocardiografia Tridimensional/métodos , Eletrocardiografia
4.
Curr Probl Cardiol ; 48(12): 102021, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37544629

RESUMO

Echocardiography is an important diagnostic imaging modality in recognizing rheumatic heart disease, a chronic sequelae of acute rheumatic fever. Left-sided heart valves, especially the mitral valve is typically affected, with stenosis or regurgitation as a consequence. Although assessment of valve area by 2D planimetry is the reference method for mitral stenosis severity, 3D planimetry provides more accurate measurement and diagnostic value. Careful selection of patients in terms of echocardiographic criteria is essential to ensure safety and success of the intervention and better long-term outcomes. Several echocardiographic scores based upon mitral valve mobility, thickening, calcification, and subvalvular thickening are developed to assess mitral valve anatomy and the feasibility of percutaneous mitral commissurotomy. 3D transesophageal echocardiography (TEE) provides detailed information of the mitral anatomy (commissural fusions, and subvalvular apparatus) before intervention. In addition, 3D TEE planimetry provides a more accurate measurement of the valve area compared with 2D echocardiography. Generally, huge annular calcification and lack of commissural fusion are unfavorable echocardiographic markers that increase the risk of complications and preclude the feasibility of percutaneous balloon mitral valvuloplasty. More contemporary prospective echocardiography research studies on patients with RHD from low- and middle-income countries are needed.


Assuntos
Valvuloplastia com Balão , Calcinose , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/terapia , Estudos Prospectivos , Ecocardiografia/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Valvuloplastia com Balão/efeitos adversos
5.
Curr Cardiol Rep ; 25(5): 391-399, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36995540

RESUMO

PURPOSE OF REVIEW: To address the following question: Are vitamin K antagonists (VKA) obsolete as stroke prevention therapy for patients with atrial fibrillation (AF) and thromboembolic risk factors? RECENT FINDINGS: A patient-level meta-analysis of the pivotal phase III randomized trials confirmed the favorable treatment effect of direct oral anticoagulants (DOAC) over VKA in multiple key patient subgroups. Among patients with AF and rheumatic heart disease (85% of whom had mitral stenosis), a randomized trial showed that rivaroxaban was not superior to VKA for stroke prevention. Caution should be exercised when prescribing DOAC for AF-related stroke prevention for patients with elevated body mass indices or history of bariatric surgery, patients with bioprosthetic heart valves, and those who require treatment with drugs that interact with cytochrome P450 and P-glycoprotein. Drug costs associated with DOAC remain considerably higher than VKA, by up to 30-fold. Direct oral anticoagulants are preferable over VKA in the large majority of eligible patients with AF and thromboembolic risk factors. The use of DOAC should be avoided for patients with mechanical heart valves or moderate/severe rheumatic mitral stenosis. Vitamin K antagonist is a reasonable option for patients who are under-represented in randomized trials, when there are significant drug-drug interactions or when patients cannot afford DOAC agents due to their higher costs.


Assuntos
Fibrilação Atrial , Estenose da Valva Mitral , Acidente Vascular Cerebral , Tromboembolia , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Anticoagulantes/efeitos adversos , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Vitamina K/uso terapêutico , Administração Oral
6.
Anatol J Cardiol ; 27(2): 71-77, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36747454

RESUMO

BACKGROUND: In rheumatic severe mitral stenosis, right ventricular mechanics deteriorate with the increasing severity of mitral stenosis. Therefore, we aimed to investigate right ventricular mechanics in patients with mild mitral stenosis using 3-dimensional speckle tracking echocardiography. METHODS: In total, 40 patients with mild mitral stenosis and 36 age- and gender-matched healthy controls were included. Conventional echocardiographic examination was performed and 3-dimensional data sets were acquired for strain analysis. Besides conventional echocardiographic parameters, right ventricular volume and function and 3-dimensional speckle tracking echocardiography-derived right ventricular free wall longitudinal strain were compared between patients with mild mitral stenosis and healthy controls. RESULTS: Although 3-dimensional right ventricular volumes and ejection fraction were similar between the groups, 3-dimensional speckle tracking echocardiography-derived right ventricular free wall longitudinal strain was significantly lower in patients with mild mitral stenosis than in controls (25.57 ± 4.39% vs. 27.90 ± 4.71%, P =.028). Significant correlations were observed between right ventricular free wall longitudinal strain and mitral valve area and estimated systolic pulmonary artery pressure (r = 0.597, P <.001; r = -0.508, P =.003, respectively). Another significant positive correlation was observed between planimetric mitral valve area and 3-dimensional speckle tracking echocardiography-derived right ventricular free wall longitudinal strain (r = 0.597, P <.001). CONCLUSION: The degree of severity of mild mitral stenosis in terms of mitral valve area can help in the early detection of subclinical right ventricular systolic function impairment which can be easily detected by 3-dimensional speckle tracking echocardiography. Right ventricular contractile performance could decrease even in mild mitral stenosis.


Assuntos
Insuficiência Cardíaca , Estenose da Valva Mitral , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Ecocardiografia , Sístole , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita
8.
Mymensingh Med J ; 31(1): 149-153, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34999695

RESUMO

Rheumatic heart disease (RHD) is a disease of poverty, is almost entirely preventable, and is the most common cardiovascular disease worldwide in those under 25 years especially in the developing county like Bangladesh. RHD is caused by acute rheumatic fever (ARF) which typically results in cumulative valvular lesions that may present clinically after a number of years of sub-clinical disease. It has a progressive course and patients usually may require valve repair/replacement in future. Echocardiography is an easily available, non-invasive, widely used, standard tool for diagnosis and evaluation of RHD. But there is scarcity of echocardiographic study of Valvular Involvement in Chronic Rheumatic Heart Disease (CHRD) in Bangladesh. This study was aimed to utilize echocardiography as a tool to evaluate patients of CRHD in Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh. This observational study was conducted in the Department of Cardiology, BSMMU from September 2018 to August 2019. Echocardiography was done in each patient only once with VividE9®machine. Among 1350 echocardiography, 101 patients (7.5%) were diagnosed as RHD including post valve replacement patients. The mean age of the patients was 40±14 years and 64.34% were female. Mitral stenosis (MS) was the commonest lesion in 84.15% followed by mitral regurgitation (MR) in 66.33%, tricuspid regurgitation (TR) in 57.43%, aortic regurgitation (AR) in 49.51%, aortic stenosis (AS) in 26.74% and pulmonary regurgitation in 10.89%. The frequency of complications like pulmonary hypertension, heart failure, atrial fibrillation (AF), LA thrombus, stroke and infective endocarditis was 67.33%, 61.05%, 18.81%, 6.93%, 3.96% and 0.99% respectively. History of Rheumatic fever was present only in 10.89% patient. Mitral stenosis was the commonest lesion seen mostly in female and most common complication was pulmonary hypertension. Mean age of patients in this study was higher than other contemporary studies and frequency as well as severity of complications was also more in female.


Assuntos
Estenose da Valva Mitral , Cardiopatia Reumática , Adulto , Bangladesh/epidemiologia , Ecocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/epidemiologia , Universidades
9.
Cardiol J ; 29(2): 245-251, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34708864

RESUMO

BACKGROUND: The treatment of choice for severe rheumatic mitral stenosis (MS) is balloon mitral valvuloplasty (BMV). Assessment of MS severity is usually performed by echocardiography. Before performing BMV, invasive hemodynamic assessment is also performed. The effect of anesthesia on the invasive assessment of MS severity has not been studied. The purpose of the present study was to assess changes in invasive hemodynamic measurement of MS severity before and after induction of general anesthesia. METHODS: The medical files of 22 patients who underwent BMV between 2014 and 2020 were reviewed. Medical history, laboratory, echocardiographic and invasive measurements were collected. Anesthesia induction was performed with etomidate or propofol. Pre-procedural echocardiographic measurements of valve area using pressure half time, and continuity correlated well with invasive measurements using the Gorlin formula. RESULTS: After induction of anesthesia the mean mitral valve gradient dropped by 2.4 mmHg (p = 0.153) and calculated mitral valve area (MVA) increased by 0.2 cm2 (p = 0.011). A wide variability in individual response was observed. While a drop in gradient was noted in 14 patients, it increased in 7. Gorlin derived MVA rose in most patients but dropped in 4. Assuming a calculated MVA of 1.5 cm2 and below to define clinically significant MS, 4 patients with pre-induction MVA of 1.5 cm2 or below had calculated MVA above 1.5 cm2 after induction. CONCLUSIONS: The impact of general anesthesia on the hemodynamic assessment of MS is heterogeneous and may lead to misclassification of MS severity.


Assuntos
Anestesia , Valvuloplastia com Balão , Estenose da Valva Mitral , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico
11.
J Am Soc Echocardiogr ; 34(9): 923-931, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33857624

RESUMO

As the life expectancy of the population continues to increase, mitral annular calcification has emerged as an important cause of mitral stenosis (MS), commonly referred to as calcific or degenerative MS. Mitral annular calcification results in valvular stenosis when calcification extends into the base of the mitral leaflet(s) and displaces the mitral valve hinge point(s) into the left ventricular inlet. Echocardiographic determination of mitral vale area is fraught with difficulties and often precludes using planimetry or the Hatle formula. Given the numerous confounders that affect transmitral flow in calcific MS, evaluation of lesion severity should incorporate flow-independent methods such as the continuity equation and the mitral valve dimensionless index. In light of the significant risks entailed, there is little enthusiasm for mitral valve replacement in patients with calcific MS. Transcatheter mitral valve replacement is generally offered on a compassionate use basis to patients deemed to be at high surgical risk.


Assuntos
Estenose da Valva Mitral , Constrição Patológica , Ecocardiografia , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem
12.
JACC Cardiovasc Imaging ; 14(3): 559-570, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33582068

RESUMO

OBJECTIVES: The aims of this study were to: 1) develop a formula for projected transmitral gradient (TMG), expected gradient under normal heart rate (HR), and stroke volume (SV); and 2) assess the prognostic value of projected TMG. BACKGROUND: In mitral stenosis (MS), TMG is highly dependent on hemodynamics, often leading to discordance between TMG and mitral valve area. METHODS: All patients with suspected MS based on echocardiography from 2001 to 2017 were analyzed. Data were randomly split (2:1); projected TMG was modeled in the derivation cohort, then tested in the validation cohort. The composite endpoint was death or mitral valve intervention. RESULTS: Of 4,973 patients with suspected MS, severe and moderate MS, defined as mitral valve area ≤1.5 and >1.5 to 2.0 cm2, were present in 437 (9%) and 936 (19%), respectively. In the derivation cohort (n = 3,315; age 73 ± 12 years; 34% male), corresponding gradients were TMG ≥6 and 4 to <6 mm Hg, respectively, under normal hemodynamics. Based on the impact of hemodynamics on TMG, the formula was projected TMG = TMG - 0.07 (HR - 70) - 0.03 (SV - 97) in men and projected TMG = TMG - 0.08 (HR - 72) - 0.04 (SV - 84) in women. In the validation cohort (n = 1,658), projected TMG had better agreement with MS severity than TMG (kappa 0.61 vs. 0.28). Among 281 patients with TMG ≥6 mm Hg, projected TMG ≥6 mm Hg, present in 171 patients (61%), was associated with higher probability of the endpoint versus projected TMG <6 mm Hg (adjusted hazard ratio: 1.8; 95% confidence interval: 1.2 to 2.6; p < 0.01). CONCLUSIONS: The novel concept of projected TMG, constructed using the observed impact of HR and SV on TMG, significantly improved the concordance of gradient and valve area in MS and provided better risk stratification than TMG.


Assuntos
Estenose da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes
13.
J Cardiovasc Comput Tomogr ; 15(2): 161-166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32798185

RESUMO

PURPOSE: To determine the reliability of subjective and objective quantification of mitral annular calcification (MAC) in elderly patients with severe aortic stenosis, to define quantitative sex- and age-related reference values of MAC, and to correlate quantitative MAC with mitral valve disease. METHODS: In this retrospective, IRB-approved study, we included 559 patients (268 females, median age 81 years, inter-quartile range 77-85 years) with severe aortic stenosis undergoing CT. Four independent readers performed subjective MAC categorization as follows: no, mild, moderate, and severe MAC. Two independent readers performed quantitative evaluation of MAC using the Agatston score method (AgatstonMAC). Mitral valve disease was determined by echocardiography. RESULTS: Subjective MAC categorization showed high inter-reader agreement for no (k â€‹= â€‹0.88) and severe MAC (k â€‹= â€‹0.75), whereas agreement for moderate (k â€‹= â€‹0.59) and mild (k â€‹= â€‹0.45) MAC was moderate. Intra-reader agreement for subjective MAC categorization was substantial (k â€‹= â€‹0.69 and 0.62). Inter- and intra-reader agreement for AgatstonMAC were excellent (ICC â€‹= â€‹0.998 and 0.999, respectively), with minor inconsistencies in MAC involving the left ventricular outflow tract/aortic valve. There were significantly more women than men with MAC (n â€‹= â€‹227, 85% versus n â€‹= â€‹209, 72%; p â€‹< â€‹0.001), with a significantly higher AgatstonMAC (median 597, range 81-2055 versus median 244; range 0-1565; p â€‹< â€‹0.001), particularly in patients ≥85 years of age. AgatstonMAC showed an area-under-the-curve of 0.84 to diagnose mitral stenosis, whereas there was no association of AgatstonMAC with mitral regurgitation (p â€‹> â€‹0.05). CONCLUSIONS: Our study in elderly patients with severe aortic stenosis shows that quantitative MAC scoring is more reliable than subjective MAC assessment. Women show higher AgatstonMAC scores than men, particularly in the elderly population. AgatstonMAC shows high accuracy to diagnose mitral stenosis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Sexuais
14.
Acta Cardiol ; 76(1): 80-86, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32452754

RESUMO

INTRODUCTION: Rheumatic heart disease predisposes to structural changes in the mitral valve including commissural fusion and calcification with subsequent narrowing of the mitral valve orifice resulting in rheumatic mitral stenosis (RMS). To define the best therapeutic strategy, an accurate measurement of mitral valve area (MVA) for RMS is of paramount importance. The propose of the present study was to assess the agreement between the mitral navigation method (MVN) and three-dimensional (3D) planimetry in the assessment of MVA in patients with RMS. METHODS: Patients who were diagnosed with a different degree of mitral stenosis with the standard transthoracic echocardiography methods such as the pressure half time and planimetry underwent 3D transesophageal echocardiography (TEE) examination. 3D TEE zoom mitral valve planimetry was measured in the diastolic frame during the mitral valve's largest opening. By using MVN software of the Philips Q-Lab, MVA was measured at its maximum diastolic opening. Both 3D planimetry (3DPL) and MVN were measured at the mid diastole during the mitral valve's largest opening. RESULTS: In this retrospective analysis, we examined consecutive 37 RMS patients (mean age 51.1 ± 11.6 years, 31 patients were female). MVA measured by the MVN method was found to be highly correlated with the 3D MVA measured by 3DPL (r = 0.937, p<.001). CONCLUSIONS: Based on our results, we showed that the MVN method may be additionally used in detecting the severity of RMS.


Assuntos
Ecocardiografia Tridimensional , Estenose da Valva Mitral , Cardiopatia Reumática/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
15.
BMJ Case Rep ; 13(12)2020 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-33372025

RESUMO

Cardiac disease after mediastinal radiotherapy can result in progressive valvular thickening and dystrophic calcification with ensuing leaflet restriction and dysfunction. This can ultimately manifest as valvular stenosis and/or regurgitation. We report a case of a 61-year-old woman with symptomatic severe aortic stenosis and severe mitral stenosis due to severe dystrophic calcification postmediastinal radiotherapy for lymphoma. She was deemed surgically inoperable due to dense, continuous calcification throughout the leaflets and annuli of both valves, aortomitral continuity, proximal coronary arteries and proximal porcelain aorta. She underwent simultaneous transcatheter aortic valve replacement and transcatheter mitral valve replacement with an excellent technical and clinical result at 7-month follow-up. We also describe the central role of multimodality three-dimensional transoesophageal echocardiography and multidetector cardiac CT imaging in assessing the severity of valve disease, characterising the nature of cardiac calcification and guiding decisions on surgical operability and transcatheter intervention.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Calcinose/complicações , Doenças das Valvas Cardíacas/complicações , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Radioterapia/efeitos adversos , Estenose da Valva Aórtica/etiologia , Calcinose/etiologia , Ecocardiografia Transesofagiana , Feminino , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca , Doença de Hodgkin/radioterapia , Humanos , Neoplasias do Mediastino/radioterapia , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estenose da Valva Mitral/etiologia , Tomografia Computadorizada Multidetectores , Imagem Multimodal , Substituição da Valva Aórtica Transcateter
16.
Mymensingh Med J ; 29(3): 579-588, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32844797

RESUMO

Rheumatic heart disease is in the declining phase, with the increase of urbanization and increment of availability of healthcare facility. However still it causes a substantial number of morbidity and mortality in South Asia. The prevalence of Rheumatic Fever and Rheumatic heart disease in Bangladesh is still high, 0.6 and 0.3 per thousand populations respectively. In the rheumatic process mitral is the frequently involved valve, mostly in the form of mitral stenosis. Choice of a treatment modality and its success largely depend on the accurate assessment of severity of disease especially the extent and distribution of calcification. Echocardiography has a key role in the determination of the severity of mitral stenosis as well as assessment of details calcification. Conventionally 2 dimensional and Doppler echocardiography is used. Now a days, 3D echocardiography offers better cardiac imaging for detail evaluation. The heart being a complex structure, the 3D evaluation would certainly offer better imaging for the accurate assessment of the mitral stenosis, especially details of presence & distribution calcification. This cross-sectional observational study was done from May 2012 to October 2012 in University Cardiac Centre, Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh. Data were collected with informed written consent, from 50 subjects who underwent transthoracic 2D and 3D Echocardiography for the assessment of rheumatic mitral valve with special emphasis on accurate assessment of severity, extent and distribution of calcification. Precise measurement of MV area is essential in the assessment of severity, which is found comparable by both 2DE (0.98±0.24cm²) and 3DE (0.92±0.23cm²). But in identifying calcification and accurate assessment of severity, more importantly commissural involvement is better detected by 3DE (p=0.002). This has extreme importance in therapeutic decision making in the treatment of chronic rheumatic MS. So, to formulate an efficient management plan, three-dimensional echocardiography has promising prospects in detecting severity & extent of rheumatic calcification.


Assuntos
Ecocardiografia Tridimensional , Estenose da Valva Mitral , Cardiopatia Reumática , Bangladesh , Estudos Transversais , Humanos
17.
Eur J Clin Invest ; 50(12): e13374, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32789848

RESUMO

BACKGROUND: The epidemiology and management of diseases can be influenced by social demographic factors. Gender and migration are among these factors. METHODS: We aimed at reviewing the impacts of gender and migration on rheumatic heart disease (RHD) epidemiology and management by a nonsystematic literature review of published studies on RHD worldwide. Our PubMed search terms included RHD pathophysiology, diagnosis, complications, management or prevention, combined with words 'rheumatic mitral stenosis (MS)', 'outcomes after percutaneous balloon mitral valvuloplasty (PBMV)', 'gender or sex difference' and 'migration'. The reporting of this study conforms to SANRA (the Scale for Assessment of Narrative Review Articles) guidelines. RESULTS: We retrieved eight studies about the impact of sex on outcomes after PBMV. All of these studies showed a female predominance for RHD. Two studies showed that there is no impact, three studies showed female sex as a predictor of poor outcomes, and the other three showed male sex a predictor of poor outcomes. Although RHD is reported to be eradicated in the developed countries, 2.1% of refugees recently screened for RHD in Italy were found to have subclinical RHD. This prevalence is similar to those found in India (2.0%), Cambodia (2.2%) and Mozambique (3%). CONCLUSIONS: There are contradicting results for outcomes after PBMV between males and females. It is not clear whether sex difference plays a role in pathophysiology, diagnosis, management and prognosis of MS. Migration has impacts on epidemiology and management of RHD. Further studies are required in these two fields to explore their relationship to RHD.


Assuntos
Valvuloplastia com Balão , Emigração e Imigração/estatística & dados numéricos , Estenose da Valva Mitral/terapia , Cardiopatia Reumática/terapia , Humanos , Estenose da Valva Mitral/epidemiologia , Cardiopatia Reumática/epidemiologia , Fatores Sexuais
18.
J Cardiovasc Magn Reson ; 22(1): 55, 2020 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-32727590

RESUMO

BACKGROUND: A comprehensive non-invasive evaluation of bioprosthetic mitral valve (BMV) function can be challenging. We describe a novel method to assess BMV effective orifice area (EOA) based on phase contrast (PC) cardiovascular magnetic resonance (CMR) data. We compare the performance of this new method to Doppler and in vitro reference standards. METHODS: Four sizes of normal BMVs (27, 29, 31, 33 mm) and 4 stenotic BMVs (27 mm and 29 mm, with mild or severe leaflet obstruction) were evaluated using a CMR- compatible flow loop. BMVs were evaluated with PC-CMR and Doppler methods under flow conditions of; 70 mL, 90 mL and 110 mL/beat (n = 24). PC-EOA was calculated as PC-CMR flow volume divided by the PC- time velocity integral (TVI). RESULTS: PC-CMR measurements of the diastolic peak velocity and TVI correlated strongly with Doppler values (r = 0.99, P < 0.001 and r = 0.99, P < 0.001, respectively). Across all conditions tested, the Doppler and PC-CMR measurement of EOA (1.4 ± 0.5 vs 1.5 ± 0.7 cm2, respectively) correlated highly (r = 0.99, P < 0.001), with a minimum bias of 0.13 cm2, and narrow limits of agreement (- 0.2 to 0.5 cm2). CONCLUSION: We describe a novel method to assess BMV function based on PC measures of transvalvular flow volume and velocity integration. PC-CMR methods can be used to accurately measure EOA for both normal and stenotic BMV's and may provide an important new parameter of BMV function when Doppler methods are unobtainable or unreliable.


Assuntos
Bioprótese , Ecocardiografia Doppler em Cores , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Imageamento por Ressonância Magnética , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes
19.
Echocardiography ; 37(8): 1159-1163, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32686863

RESUMO

OBJECTIVE: The objective of the study was to evaluate the accuracy of the mitral leaflet separation index (MLSI) in selected patients with mitral stenosis, before and after percutaneous balloon mitral valvuloplasty (PBMV), compared to conventional methods with transthoracic echocardiography [TTE]. METHODS: A prospective study was conducted in 30 patients, ages 20-60 years, with severe symptomatic mitral stenosis (MS) who had PBMV in the Cardiology Department, Zagazig University and National Heart Institute. A mean of three to five measurements of MLSI was taken in diastole in the parasternal long-axis and apical four-chamber views. The MLSI was re-measured 24-48 hours after PBMV. We calculated the correlation of the MLSI, pre and post BMV, with two-dimensional (2D) MV planimetry and pressure half-time (PHT) methods to assess MVA. RESULTS: There was a positive, highly significant correlation between pre PBMV 2D planimetry and MLSI (r = .665, P-value < .001) as well as post PBMV 2D planimetry and MLSI (r = .410, P-value = .025). A positive highly significant correlation was also noted between pre PBMV PHT and MLSI (r = .678, P-value <.001) and between post PBMV PHT and MLSI (r = .706, P-value <.001). CONCLUSION: Mitral leaflet separation index is an easy and reliable measurement for the assessment of mitral stenosis before and after PBMV.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Adulto , Ecocardiografia , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Adulto Jovem
20.
BMC Cardiovasc Disord ; 20(1): 157, 2020 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-32248819

RESUMO

BACKGROUND: We studied the course of plasma concentrations of 4 cardiovascular biomarkers: natriuretic peptides (BNP, NT-proBNP; mid-regional (MR) pro-atrial NP); and soluble endothelial CD146 (sCD146), in patients with severe mitral valve stenosis undergoing percutaneous mitral commissurotomy (PMC) to identify potential markers of procedural success. METHODS: Biomarkers were tested in 40 patients the day before and the day after PMC. Success was defined as mitral valve area ≥ 1.5 cm2; or an increase of ≥0.5 cm2 in mitral valve area associated with echocardiographic mitral regurgitation

Assuntos
Fator Natriurético Atrial/sangue , Procedimentos Cirúrgicos Cardíacos , Estenose da Valva Mitral/cirurgia , Idoso , Biomarcadores/sangue , Antígeno CD146/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/sangue , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Peptídeo Natriurético Encefálico/sangue , Paris , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA