Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Congenit Heart Dis ; 14(5): 691-699, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30989806

RESUMO

BACKGROUND: Little is known about the early time course of biventricular function and mechanics after tetralogy of Fallot (TOF) repair. We sought to evaluate and describe the evolution of the right ventricle (RV) after TOF repair in young infants and children using conventional echocardiographic parameters and global longitudinal strain (GLS). METHODS: A retrospective review was performed of all patients with TOF and pulmonary stenosis who underwent repair from January 2002 to September 2015 and had at least 3 serial postsurgical echocardiograms spanning from infancy to early childhood (<8 years). Student's t test was performed to compare patients who underwent valve sparing (VS) versus transannular patch (TAP) repair. ANOVA was used to track measures of ventricular systolic function over time. RESULTS: We analyzed 151 echocardiograms performed on 42 patients. Pulmonary regurgitation (PR, moderate or severe) and the RV to left ventricular (LV) basal dimension ratio were higher in TAP patients (P < .04 at all-time points). Along with a significant increase in RV basal diameter Z-score in the TAP group (P < .001), there was an improvement in RV and LV GLS over time in both groups (P < .001). The LV GLS at last follow-up was lower in patients who underwent reoperation than those who did not (P = .050). LV GLS at the last follow-up echocardiogram was lower in patients with significant PR than those without (P < .001). CONCLUSIONS: Ventricular function appeared improve over time from the initial postoperative period in TOF patients. TAP repair was associated with a progressively higher RV/LV ratio in young children. GLS and RV/LV basal diameter ratio may be useful when following young children after TOF repair. Further research is necessary to understand the trajectory of ventricular functional and volumetric changes in young children in order to provide the most effective lifetime management of patients with TOF.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ventrículos do Coração/fisiopatologia , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Criança , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Lactente , Masculino , Período Pós-Operatório , Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico , Tetralogia de Fallot/fisiopatologia
2.
Int J Cardiovasc Imaging ; 35(8): 1453-1463, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30937683

RESUMO

To compare contrast-enhanced magnetic resonance angiography (ceMRA) and 3D steady-state free precession (SSFP) during systole and diastole for assessment of the right ventricle outflow tract (RVOT) in patients considered for percutaneous pulmonary valve implantation (PPVI) after tetralogy of Fallot (TOF) repair. We retrospectively evaluated 89 patients (male: 45, mean age 19 ± 8 years), who underwent cardiac-MRI after surgical TOF-repair. Datasets covering the whole heart in systole and diastole were acquired using ECG-gated 3D SSFP and non-gated ceMRA. Measurements were performed in SSFP-sequences and in ceMRA in the narrowest region of the RVOT to obtain the minimum, maximum and effective diameter. Invasive balloon sizing as the gold standard was available in 12 patients. The minimum diameter in diastolic SSFP, systolic SSFP and ceMRA were 21.4 mm (± 6.1 mm), 22.6 mm (± 6.2 mm) and 22.6 mm (± 6.0 mm), respectively. Maximum diameter was 29.9 mm (± 9.5 mm), 30.0 mm (± 7.0 mm) and 28.8 mm (± 8.1 mm) respectively. The effective diameter was 23.2 mm (± 5.7 mm), 27.4 mm (± 6.7 mm) and 24.4 mm (± 6.2 mm), differing significantly between diastole and systole (p < 0.0001). Measurements in ECG-gated SSFP showed a better inter- and intraobserver variability compared to measurements in non-ECG-gated ceMRA. Comparing invasive balloon sizing with our analysis, we found the highest correlation coefficients for the maximum and effective diameter measured in systolic SSFP (R = 0.99 respectively). ECG-gated 3D SSFP enables the identification and characterization of a potential landing zone for PPVI. The maximum and effective systolic diameter allow precise sizing for PPVI. Patients with TOF-repair could benefit from cardiac MRI before PPVI.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Valvuloplastia com Balão , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Técnicas de Imagem de Sincronização Cardíaca , Criança , Meios de Contraste/administração & dosagem , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Função Ventricular Direita , Adulto Jovem
3.
Heart ; 100(17): 1354-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24780907

RESUMO

OBJECTIVE: In adult patients with mild-to-moderate pulmonary valve (PV) stenosis, exercise capacity and haemodynamics have not been extensively studied, although regular exercise is recommended. Therefore, we aimed to assess exercise capacity to study the increase in PV gradient during exercise and to evaluate the impact of this increased pressure load on the RV. METHODS: Nineteen patients (8 female; 29±6.4 years) with isolated mild-to-moderate PV stenosis and no prior cardiac interventions were consecutively enrolled from the outpatient clinic of adult congenital heart disease. All patients underwent cardiopulmonary exercise testing, transthoracic echocardiography and bicycle stress echocardiography. Results for exercise testing were compared with age-matched and gender-matched control patients. RESULTS: In the studied population, resting heart rate (89±11 vs 75±14 bpm; p=0.001), peak power (199±66 vs 263±68 W; p=0.006); peak VO2 (31.2±9.9 vs 39±7.4 mL/kg/min; p=0.011); oxygen uptake efficiency slope (2430±913 vs 3292±943(mL/min)/(L/min); p=0.007) and VE/VCO2 slope (26.8±5.2 vs 22.6±4.3; p=0.01) differed significantly from controls. A linear increase of peak PV gradient with increasing flow was observed in the pooled dataset (Pearson's R=0.947; p<0.0001) and slopes identical as for control patients were obtained for the oxygen pulse-workload relationship. Right heart morphology and function were preserved in the studied patients. CONCLUSIONS: Patients with mild-to-moderate PV stenosis have decreased exercise capacity. A linear increase in PV gradient with flow suggests a fixed valve area throughout the exercise. Although systolic RV pressure load increases during exercise, good ventricular performance was observed without signs of functional or morphological changes of the right heart. CLINICAL TRIAL NUMBER: NCT01444222.


Assuntos
Teste de Esforço , Tolerância ao Exercício , Hemodinâmica , Estenose da Valva Pulmonar/diagnóstico , Valva Pulmonar/fisiopatologia , Adulto , Distribuição de Qui-Quadrado , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Frequência Cardíaca , Humanos , Modelos Lineares , Masculino , Consumo de Oxigênio , Valor Preditivo dos Testes , Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Índice de Gravidade de Doença , Função Ventricular Direita , Pressão Ventricular , Adulto Jovem
4.
Eur J Radiol ; 83(2): 378-83, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24176531

RESUMO

BACKGROUND: Information about thoracic vascular sizes can crucially affect clinical decision-making in cardiovascular disease. A variety of imaging techniques such as catheter angiography, contrast enhanced computed tomography (CT) and cardiac magnetic resonance imaging (CMR) are routinely used to measure vascular diameters. Traditionally, CMR black blood sequences were the main anatomical tool for visualization of vascular anatomy and still are in many centers. More recently, the vessel diameters are measured on multiplanar reconstructions derived from static magnetic resonance angiography (MRA). This study was performed to investigate the variation of vessel diameter measurements on different CMR techniques with respect to their data acquisition scheme. METHODS: We recruited two groups of patients for this prospective study. One group included patients with repaired tetralogy of Fallot (TOF), with at least moderate pulmonary insufficiency and another group of patients who underwent CMR as part of a diagnostic work-up for arrhythmogenic right ventricular cardiomyopathy (ARVC). Additional images of the right pulmonary artery (RPA) were acquired in the double inversion recovery (DIR) black blood, cine steady state free precession (SSFP) and MRA. All images were reviewed by two CMR trained readers using the electronic caliper provided within the picture archiving and communication system package. The maximum diameter of each artery was recorded in millimeters with up to one decimal point. Paired t-tests and Bland-Altman plots were used for comparison of measurements between different sequences. RESULTS: A total of 52 patients were recruited for this study, 26 patients in the TOF group (15 males, age 12.55±2.9) and 26 patients in the ARVC group (15 males, age 15.6±2.3). In both groups, the RPA sizes were not significantly different between the DIR images and diastolic cine SSFP (p>0.05). Measurements on DIR were significantly smaller than those made on systolic cine SSFP or MRA in both groups (p<0.0001). Vessel diameters measured on systolic SSFP were significantly larger than measurements made on diastolic SSFP (p<0.0001). There was no significant difference between vessel measurements on MRA and measurements on systolic cine SSFP (p=0.44 for the TOF group and p=0.79 for ARVC group). Measurements on the MRA datasets were significantly larger than those on diastolic SSFP images (p<0.0001). CONCLUSION: Black blood, white blood and MRA sequences are all reproducible CMR methods for the assessment of arterial diameters in children and adolescents. Measurements from systolic phase SSFP images are comparable to those from contrast-enhanced MRA. Therefore, the administration of contrast medium is not necessary in every case. Cine SSFP images offer the additional advantage over the other methods in such that both the largest and the smallest diameter of the vessel during the cardiac cycle can be assessed using this technique. This is even more relevant in highly pulsatile circulations, such as patients with repaired TOF and significant pulmonary insufficiency.


Assuntos
Angiografia por Ressonância Magnética/métodos , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Estenose da Valva Pulmonar/patologia , Estenose da Valva Pulmonar/fisiopatologia , Fluxo Pulsátil , Adolescente , Velocidade do Fluxo Sanguíneo , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Acta Radiol ; 54(10): 1132-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23864059

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is one of the most common types of congenital heart disease and requires prompt surgical correction. Post-correction pulmonary insufficiency (PI) often ensues in adulthood. At times, the PI is accompanied by residual pulmonary stenosis (PS). Little is known regarding right ventricular (RV) function in the setting of combined PS and PI. PURPOSE: To compare cardiac magnetic resonance (CMR) parameters for the assessment of RV function between patients with combined pulmonary stenosis and pulmonary insufficiency (PSPI) and isolated PI following surgical repair of TOF. MATERIAL AND METHODS: Retrospective review of patients with comparable corrected TOF and similar PI was performed. Seventeen patients (median age, 24 years; range, 10-52 years) had combined PSPI and 30 patients (median age, 30 years; range, 6-70 years) had isolated PI. Cine magnetic resonance (MR) images (Philips Medical Systems, Best, The Netherlands) in the short-axis plane were used to calculate end-systolic, end-diastolic, and stroke volumes (RVESV, RVEDV, RVSV) and to measure RV wall thickness. Velocity-encoded cine MR images were used to measure pulmonary regurgitation fraction (PRF) by calculating the ratio of backward flow and total forward flow, obtained from the main pulmonary flow analysis. Peak pressure gradient across the pulmonary valve was obtained from spectral Doppler echocardiography. RESULTS: RVEF was 51 ± 8% in the PSPI patients and 39 ± 11%, in the patients with isolated PI (P = 0.001). Additionally, RV wall thickness was 5.2 ± 0.8 mm in the PSPI patients compared to 2.6 ± 0.9 mm in the isolated PI patients (P = 0.001). RVESVi and RVEDVi were significantly lower (P < 0.05) in patients with combined PSPI (60 ± 21 mL/m(2), 121 ± 35 mL/m(2), respectively) compared to the patients with isolated PI (95 ± 48 mL/m(2), 152 ± 61 mL/m(2), respectively). CONCLUSION: RV function is preserved in patients with PSPI when compared to patients with PI following surgical repair of TOF.


Assuntos
Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Idoso , Criança , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Insuficiência da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/complicações , Estudos Retrospectivos
7.
Eur J Radiol ; 80(2): e164-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20696542

RESUMO

BACKGROUND: There are concerns whether there is a difference in clinical utility of pulmonary regurgitation (PR) fraction (PRF) and PR volume (PRV) in subgroups of patients with isolated PR and individuals with combined PR and right ventricular outflow tract obstruction (RVOTO). The aim of the study was to compare PRF and PRV in patients with or without RVOTO. METHODS AND RESULTS: 82 consecutive patients after repair of tetralogy of Fallot (TOF) who underwent cardiovascular magnetic resonance and echocardiography were studied. There was no difference in PRF between patients with moderate and severe right ventricular (RV) dilatation (32±13% vs. 37±12%; p=0.18). Significant difference in PRV was observed between these groups (23±10 ml/m2 vs. 31±12 ml/m2, respectively; p=0.02). PRV had better ability than PRF in identification of severe RV dilatation, both in group with RVOTO [area under the curve (AUC) 0.82 vs. 0.72, p=0.005] and in patients without RVOTO (AUC 0.83 vs. 0.77, p=0.04). A strong correlation was seen between PRF and PRV both in patients with and without RVOTO [r=0.93, p<0.0001 and r=0.92, p<0.0001, respectively]. In both subgroups high variability of PRF was found in subjects with similar degree of PRV. CONCLUSIONS: PRV shows better ability than PRF in evaluating influence of PR on RV in patients after TOF repair, both in population with and without concomitant RVOTO.


Assuntos
Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Adulto , Análise de Variância , Área Sob a Curva , Procedimentos Cirúrgicos Cardíacos , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estatísticas não Paramétricas , Tetralogia de Fallot/cirurgia
8.
Echocardiography ; 21(1): 17-25, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14717716

RESUMO

UNLABELLED: The effects of chronic volume or pressure overload on the velocity of right ventricular ejection have not been previously well defined. We hypothesized that, as formerly shown for the left ventricle, there would be a direct relationship between the velocity of ejection and an estimate of systolic wall stress. METHODS: Echocardiograms of asymptomatic patients, not on cardiac medications, with either an isolated secundum atrial septal defect > or = 5 mm in diameter or isolated pulmonic stenosis with a peak instantaneous pressure gradient > or = 20 mmHg, were reviewed. Forty-one patients with an atrial septal defect and 34 with pulmonary stenosis met criteria, and were compared to age-matched normal controls. Total subjects were 127 with ages ranging from 1 day to 54 years. Right ventricular monoplane ejection fraction, ejection time corrected for heart rate (ETc), mean normalized systolic ejection rate (MNSERc) and meridianal peak-systolic wall stress (WSps) were measured. RESULTS: Compared to controls, ejection fractions were not significantly different, but WSps averaged 81% and 110% higher, ETc 8% and 9% longer, and MNSERc 5% and 9% slower in the atrial septal defect and pulmonary stenosis groups, respectively. Among all subjects WSps had a significant linear correlation with ETc (r = 0.61, P < 0.01), MNSERc (r =-0.46, P < 0.01), and ejection fraction (r =-0.19, P < 0.05). CONCLUSIONS: Increases in WSps cause an incremental slowing of MNSERc in the right ventricle, with a relationship that is linear over a wide range of normal and abnormal loading conditions.


Assuntos
Ecocardiografia/métodos , Comunicação Interatrial/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Superfície Corporal , Criança , Pré-Escolar , Feminino , Comunicação Interatrial/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estenose da Valva Pulmonar/fisiopatologia , Sístole
9.
Am Heart J ; 147(1): 165-72, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14691436

RESUMO

AIMS: The purpose of this study was to compare the noninvasive assessment of severity of pulmonary regurgitation with Doppler echocardiography versus cardiovascular magnetic resonance imaging (CMR) in adult patients with repaired tetralogy of Fallot (rTOF). METHODS: We studied 52 (22 females) consecutive patients (aged 32 +/- 2 years, 23 +/- 5 years after rTOF) using Doppler echocardiography and compared these findings with CMR. From the continuous-wave Doppler trace, the duration of pulmonary regurgitation and of total diastole was measured and the ratio between the 2 was defined as pulmonary regurgitation index (PRi). Pulmonary regurgitant fraction (PRF) was assessed with flow phase velocity mapping with CMR. RESULTS: Patients were divided into 2 groups according to the median value (24.5%) of PRF measured by CMR: Group I (26 patients) with PRF < or =24.5% and Group II with PRF >24.5%. There was no difference between patients' age, sex, or age at repair between the 2 groups. More patients from Group II had a right ventricular outflow or transannular patch repair compared to Group I (12/26 [46%] vs 6/26 [23%], P <.01). Mean pulmonary regurgitation time was shorter (340 +/- 60 vs 440 +/- 135 ms, P =.001) and PRi was lower (0.61 +/- 0.11 vs 0.91 +/- 0.11, P <.001) in Group II compared to Group I. Color Doppler regurgitant jet was also broader in Group II (1.4 +/- 0.4 vs 0.7 +/- 0.5 cm, P <.001), signifying more severe pulmonary regurgitation. Doppler-measured PRi correlated closely with CMR regurgitant fraction (r = -0.82, P <.001) and with color Doppler pulmonary regurgitant jet width (r = -0.66, P <.001); the latter correlated with PRF assessed with CMR (r = 0.72, P <.001). A PRi <0.77 had 100% sensitivity and 84.6% specificity for identifying patients with pulmonary regurgitant fraction >24.5%, with a predictive accuracy of 95%. Furthermore, echocardiographically-assessed right ventricular end-diastolic dimensions correlated with CMR end-diastolic volume index (r = 0.49, P <.001 ). CONCLUSIONS: Pulmonary regurgitation is common in asymptomatic adults with rTOF. Severity of pulmonary regurgitation and its effects on right ventricular dimensions in these patients can be assessed noninvasively by Doppler echocardiography and CMR, with reasonable agreement between the 2 techniques.


Assuntos
Ecocardiografia Doppler , Imageamento por Ressonância Magnética , Complicações Pós-Operatórias/diagnóstico , Insuficiência da Valva Pulmonar/diagnóstico , Tetralogia de Fallot/cirurgia , Adulto , Diástole , Ecocardiografia Doppler/métodos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Análise de Regressão , Estatísticas não Paramétricas , Tetralogia de Fallot/diagnóstico por imagem , Fatores de Tempo , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia
10.
J Am Soc Echocardiogr ; 9(6): 805-13, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9035699

RESUMO

This study was designed to determine (1) the value of Doppler echocardiography in depicting the presence of a fetal pulmonary stenosis, (2) its reliability in the assessment of the severity of the lesion, and (3) the usefulness of additional markers from the left side of the heart as criteria of severity. Fourteen pregnant ewes were included in this study (gestational age, 90 to 120 days). Banding of the fetal main pulmonary artery created mild (n = 3), moderate (n = 3), and severe (n = 5) stenosis. Three lambs were sham operated. Intrauterine fetal Doppler echocardiographic data obtained 15 days after surgery were compared with preoperative values. Peak velocities recorded through the band increased linearly from baseline in the groups with mild and moderate stenosis but did not show any further increase in the group with severe stenosis. Compared with the sham-operated group, right ventricular output in the group with stenosis was either similar or reduced significantly. The increase in right ventricular free wall thickness was significantly greater in the groups with stenosis compared with that of the sham-operated group; the correlation with the degree of severity was r = 0.65 and p < 0.05. A A stronger positive correlation was found between the severity of stenosis and aortic valve diameters: r = 0.82 and p < 0.01. The strongest correlation was found for right ventricular/left ventricular outputs (r = 0.92; p < 0.001). Thus Doppler peak velocities through the obstruction can help detect pulmonic stenosis but are not reliable for the assessment of its severity during fetal life. Other ultrasound measurements such as the size of the aortic anulus and especially the ratio of right ventricular/left ventricular output could be used as sensitive markers of the severity of stenosis.


Assuntos
Ecocardiografia Doppler , Doenças Fetais/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Animais , Velocidade do Fluxo Sanguíneo , Feminino , Hemodinâmica , Gravidez , Estenose da Valva Pulmonar/patologia , Estenose da Valva Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Ovinos , Ultrassonografia Pré-Natal
11.
J Nucl Med ; 32(12): 2215-20, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1744706

RESUMO

Thallium-201 planar and SPECT studies were performed in 38 children with congenital heart disease using high-resolution three-headed SPECT. The 201Tl total or average right ventricular-to-left ventricular (RV/LV) count ratios were measured by summed short-axis images. In the planar study, the RV/LV systolic pressure ratio correlated with 201Tl RV/LV average count ratio (r = 0.91) better than that in the SPECT study (r = 0.78). However, in the SPECT study, patients with atrial septal defect (n = 9), ventricular septal defect (n = 13), tetralogy of Fallot and double outlet right ventricle (n = 6) showed a characteristic distribution in the plot of RV/LV pressure ratio versus 201Tl RV/LV total count ratio. A prospective study showed that the RV/LV average count ratio was a good predictor of RV/LV pressure ratio (n = 19, r = 0.91). Three-headed SPECT is useful for pediatric cardiac studies, and the overload types found in congenital heart disease seemed to be differentiated by the SPECT study.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Direita/fisiologia , Adolescente , Criança , Pré-Escolar , Dupla Via de Saída do Ventrículo Direito/diagnóstico por imagem , Dupla Via de Saída do Ventrículo Direito/fisiopatologia , Feminino , Cardiopatias Congênitas/fisiopatologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/fisiopatologia , Humanos , Lactente , Masculino , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia
12.
Am J Cardiol ; 68(6): 648-52, 1991 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-1831588

RESUMO

Patients with severe pulmonic stenosis (PS) have right ventricular (RV) diastolic filling abnormalities detectable by tricuspid valve pulsed Doppler examination. To determine if these abnormalities persist long term after successful therapy of PS, 19 patients were examined 8 +/- 3 years after PS therapy. At the time of follow-up Doppler examination, the PS gradient was 15 +/- 8 mm Hg. From the tricuspid valve inflow Doppler study, the following measurements were obtained at peak inspiration: peak velocities at rapid filling (peak E) and during atrial contraction (peak A), ratio of peak E to peak A velocities, RV peak filling rate normalized for stroke volume, deceleration time, the fraction of filling in the first 0.33 of diastole as well as under the E and A waves, and the ratio of E to A area. Data from PS follow-up patients were compared with our previously reported data from 12 age-related control subjects and 14 untreated patients with PS. Patients with PS who were followed up had higher peak E velocity (0.75 +/- 0.14 vs 0.59 +/- 0.21 m/s), lower peak A velocity (0.47 +/- 0.09 vs 0.64 +/- 0.28 m/s), higher E/A velocity ratio (1.65 +/- 0.33 vs 1.11 +/- 0.52), higher 0.33 area fraction (0.52 +/- 0.08 vs 0.34 +/- 0.14), lower A area fraction (0.29 +/- 0.06 vs 0.45 +/- 0.21) and higher E/A area ratio (2.48 +/- 0.82 vs 1.73 +/- 1.05) than PS patients without treatment (p less than 0.03). All Doppler indexes of the patients with PS who were followed up were the same as those of the control subjects except for the peak E velocity that was slightly higher (0.75 +/- 0.14 vs 0.63 +/- 0.11 m/s), the peak A velocity that was slightly higher (0.47 +/- 0.09 vs 0.38 +/- 0.09 m/s) and the E/A area ratio that was slightly lower (2.48 +/- 0.82 vs 3.50 +/- 1.25) (p less than 0.03). Thus, at long-term follow-up, all RV diastolic filling indexes in successfully treated patients with PS improved compared with the untreated patients and approached values found in normal subjects.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Volume Cardíaco/fisiologia , Diástole/fisiologia , Estenose da Valva Pulmonar/cirurgia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Cardiomegalia/fisiopatologia , Cateterismo , Criança , Pré-Escolar , Ecocardiografia Doppler , Seguimentos , Humanos , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/terapia , Volume Sistólico/fisiologia , Fatores de Tempo
13.
Thorac Cardiovasc Surg ; 39(3): 143-9, 1991 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1882377

RESUMO

If not all of the right ventricular outflow tract obstruction (RVOTO) is removed in the operation for pulmonary stenosis, high right ventricular pressure can sometimes occur afterward. However, it is not easy to assess the amount of RVOTO that is to be removed, and there is no quantifiable method for selecting operative procedures. The aim of this report is to discuss the formulation of a numerical indicator, based on the parameters peak systolic right-ventricular pressure (RVP), systolic systemic arterial pressure (AP), pulmonary valvular orifice size (VS), and body surface area (BSA), from the results obtained in sixty-four open heart surgeries for pulmonary stenosis with intact ventricular septum. A group, in which an outflow tract patch was not used and which had a higher pre-operative RVP/AP ratio, had a tendency to have a correspondingly higher RVP/AP ratio one month after the operation. Most patients with a high RVP/AP ratio one month after the operation showed a significant decrease in this ratio a long time after the operation. But, there were exceptions to this rule where the ratio remained high. Reconstruction of the right ventricular outflow was considered for some patients whose RVP/AP ratios remained high. Reconstruction of the RVOT by using an outflow tract patch worked well for patients with an associated infundibular stenosis. A subannular patch was used for patients with infundibular stenosis, and a transannular patch was used for patients with annular stenosis. The optimal annulus size was such that VS/BSA was not less than 2 cm2/m2. A transannular monocusp patch was applied to an area which was more than 10 mm wide.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Estenose da Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Pressão Sanguínea , Superfície Corporal , Criança , Pré-Escolar , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Prognóstico , Valva Pulmonar/anatomia & histologia , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/fisiopatologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
14.
Vutr Boles ; 28(2): 47-53, 1989.
Artigo em Búlgaro | MEDLINE | ID: mdl-2763524

RESUMO

In 216 patients with right ventricular cardiac overload the changes of 76 electrophysiological indices were studied--indices of the corrected orthogonal electrocardiogram after Frank, corrected orthogonal vectorcardiogram, spatial electrocardiogram and high-speed spatial electrocardiogram. The patients with right ventricular cardiac overload are divided into two basic groups--patients with systolic and patients with diastolic overload. The indices are assessed on the basic criteria of sensitivity, specificity and realization. Variation analysis as well as statistical comparison with 119 healthy persons are performed. On the basis of the results of the study "sets" of 4 indices each with 97-98% sensitivity are determined, indices from all methods used are included in the "sets". The conclusion is reached of the good possibilities of the electrophysiological methods when a combination of indices with the help of a computer is made.


Assuntos
Comunicação Interatrial/fisiopatologia , Coração/fisiopatologia , Estenose da Valva Mitral/fisiopatologia , Adulto , Diástole , Eletrocardiografia , Eletrofisiologia , Comunicação Interatrial/diagnóstico , Ventrículos do Coração/fisiopatologia , Humanos , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/fisiopatologia , Sístole , Vetorcardiografia
15.
Am J Cardiol ; 61(13): 1092-7, 1988 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-3364363

RESUMO

It is not known whether Doppler echocardiography can accurately follow changes in right-sided cardiac hemodynamics after a therapeutic intervention in patients with pulmonary artery (PA) hypertension. Therefore, Doppler measurements of the maximal velocity of the tricuspid regurgitant jet and the acceleration time of the PA velocity profile were obtained in 28 patients before and after pulmonary thromboendarterectomy for chronic thromboembolic PA hypertension. Doppler values were compared with hemodynamic variables obtained at cardiac catheterization. Postoperatively, decreases in mean PA pressure (50 +/- 14 to 28 +/- 8 mm Hg), transtricuspid systolic pressure difference (69 +/- 21 to 36 +/- 14 mm Hg) and Doppler measurement of the maximal velocity of the tricuspid regurgitant jet (4.1 +/- 0.7 to 2.7 +/- 0.5 m/s) were noted, while acceleration time increased (57 +/- 16 to 94 +/- 18 ms, all p less than 0.001) compared with preoperative values. For the population as a whole, the calculated systolic transtricuspid pressure difference determined from the maximal velocity of tricuspid regurgitation correlated well with the catheterization systolic transtricuspid pressure difference (r = 0.93, p less than 0.001) and the acceleration time correlated with mean PA pressure (r = -0.81, p less than 0.001). More importantly, the change in the maximal velocity of tricuspid regurgitation for postoperative patients was found to correlate with the change in catheterization systolic transtricuspid pressure difference (r = 0.82, p less than 0.001), while the change in acceleration time correlated weakly with the change in mean PA pressure (r = -0.41, p = 0.053).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Ecocardiografia , Endarterectomia , Coração/fisiopatologia , Hemodinâmica , Hipertensão Pulmonar/cirurgia , Artéria Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Trombose/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Doença Crônica , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Sístole , Trombose/fisiopatologia , Fatores de Tempo , Insuficiência da Valva Tricúspide/fisiopatologia , Resistência Vascular
16.
Ann Thorac Surg ; 44(6): 633-6, 1987 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3689047

RESUMO

The response to intravenous administration of propranolol hydrochloride was studied in 24 children undergoing operation for isolated or complex right ventricular outflow tract obstruction. Ten had pulmonary valve stenosis, 4 had pulmonary valve stenosis plus ventricular septal defect, 8 had tetralogy of Fallot, and 2 had complex lesions. Propranolol (0.01 to 0.2 mg per kilogram of body weight) was given to patients with a residual right ventricular to left ventricular systolic pressure ratio greater than 0.75. Four children did not respond to propranolol and required further surgical intervention. Twenty patients responded, 2 of whom died. Fifteen were restudied by cardiac catheterization 3 weeks to 27 months postoperatively. The right ventricle-pulmonary artery gradient was 25 mm Hg or less in 13 patients. We conclude that a small dose of propranolol given intraoperatively can identify patients in whom a reduction in the right ventricle-pulmonary artery gradient to acceptable levels will occur in the months following operation. This may reduce the need for placement of a subannular or transannular patch in some patients.


Assuntos
Comunicação Interventricular/diagnóstico , Propranolol , Estenose da Valva Pulmonar/diagnóstico , Tetralogia de Fallot/diagnóstico , Pressão Sanguínea/efeitos dos fármacos , Cateterismo Cardíaco , Criança , Pré-Escolar , Relação Dose-Resposta a Droga , Comunicação Interventricular/fisiopatologia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Humanos , Período Pós-Operatório , Propranolol/administração & dosagem , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/cirurgia , Reoperação , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA